Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 114
Filtrar
1.
Thorax ; 77(3): 259-267, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34737194

RESUMO

BACKGROUND: Continuous positive airways pressure (CPAP) and high-flow nasal oxygen (HFNO) are considered 'aerosol-generating procedures' in the treatment of COVID-19. OBJECTIVE: To measure air and surface environmental contamination with SARS-CoV-2 virus when CPAP and HFNO are used, compared with supplemental oxygen, to investigate the potential risks of viral transmission to healthcare workers and patients. METHODS: 30 hospitalised patients with COVID-19 requiring supplemental oxygen, with a fraction of inspired oxygen ≥0.4 to maintain oxygen saturation ≥94%, were prospectively enrolled into an observational environmental sampling study. Participants received either supplemental oxygen, CPAP or HFNO (n=10 in each group). A nasopharyngeal swab, three air and three surface samples were collected from each participant and the clinical environment. Real-time quantitative polymerase chain reaction analyses were performed for viral and human RNA, and positive/suspected-positive samples were cultured for the presence of biologically viable virus. RESULTS: Overall 21/30 (70%) participants tested positive for SARS-CoV-2 RNA in the nasopharynx. In contrast, only 4/90 (4%) and 6/90 (7%) of all air and surface samples tested positive (positive for E and ORF1a) for viral RNA respectively, although there were an additional 10 suspected-positive samples in both air and surfaces samples (positive for E or ORF1a). CPAP/HFNO use or coughing was not associated with significantly more environmental contamination than supplemental oxygen use. Only one nasopharyngeal sample was culture positive. CONCLUSIONS: The use of CPAP and HFNO to treat moderate/severe COVID-19 did not appear to be associated with substantially higher levels of air or surface viral contamination in the immediate care environment, compared with the use of supplemental oxygen.


Assuntos
COVID-19 , SARS-CoV-2 , Aerossóis , Pressão Positiva Contínua nas Vias Aéreas/métodos , Humanos , RNA Viral
2.
J Sleep Res ; 31(6): e13694, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35840352

RESUMO

This SERVE-HF (Treatment of Predominant Central Sleep Apnea by Adaptive Servo Ventilation in Patients With Heart Failure) sub study analysis evaluated polysomnography (PSG) data in patients with heart failure with reduced ejection fraction (HFrEF) and predominant central sleep apnea (CSA) randomised to guideline-based medical therapy, with or without adaptive servo ventilation (ASV). Patients underwent full overnight PSG at baseline and at 12 months. All PSG recordings were analysed by a core laboratory. Only data for patients with baseline and 3- or 12-month values were included. The sub study included 312 patients; the number with available PSG data differed for each variable (94-103 in the control group, 77-99 in the ASV group). After 12 months, baseline-adjusted respiratory measures were significantly better in the ASV group versus control. Although some between-group differences in sleep measures were seen at 12 months (e.g., better sleep efficiency in the ASV group), these were unlikely to be clinically significant. The number of periodic leg movements during sleep (PLMS) increased in the ASV group (p = 0.039). At 12 months, the respiratory arousal index was significantly lower in the ASV versus control group (p < 0.001), whilst the PLMS-related arousal index was significantly higher in the ASV group (p = 0.04 versus control). ASV attenuated the respiratory variables characterising sleep apnea in patients with HFrEF and predominant CSA in SERVE-HF. Sleep quality improvements during ASV therapy were small and unlikely to be clinically significant. The increase in PLMS and PLMS-related arousals during ASV warrants further investigation, particularly relating to their potential association with increased cardiovascular risk.


Assuntos
Insuficiência Cardíaca Sistólica , Insuficiência Cardíaca , Apneia do Sono Tipo Central , Disfunção Ventricular Esquerda , Humanos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca Sistólica/complicações , Insuficiência Cardíaca Sistólica/terapia , Polissonografia , Sono , Apneia do Sono Tipo Central/complicações , Apneia do Sono Tipo Central/terapia , Volume Sistólico , Resultado do Tratamento
3.
JAMA ; 327(6): 546-558, 2022 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-35072713

RESUMO

Importance: Continuous positive airway pressure (CPAP) and high-flow nasal oxygen (HFNO) have been recommended for acute hypoxemic respiratory failure in patients with COVID-19. Uncertainty exists regarding the effectiveness and safety of these noninvasive respiratory strategies. Objective: To determine whether either CPAP or HFNO, compared with conventional oxygen therapy, improves clinical outcomes in hospitalized patients with COVID-19-related acute hypoxemic respiratory failure. Design, Setting, and Participants: A parallel group, adaptive, randomized clinical trial of 1273 hospitalized adults with COVID-19-related acute hypoxemic respiratory failure. The trial was conducted between April 6, 2020, and May 3, 2021, across 48 acute care hospitals in the UK and Jersey. Final follow-up occurred on June 20, 2021. Interventions: Adult patients were randomized to receive CPAP (n = 380), HFNO (n = 418), or conventional oxygen therapy (n = 475). Main Outcomes and Measures: The primary outcome was a composite of tracheal intubation or mortality within 30 days. Results: The trial was stopped prematurely due to declining COVID-19 case numbers in the UK and the end of the funded recruitment period. Of the 1273 randomized patients (mean age, 57.4 [95% CI, 56.7 to 58.1] years; 66% male; 65% White race), primary outcome data were available for 1260. Crossover between interventions occurred in 17.1% of participants (15.3% in the CPAP group, 11.5% in the HFNO group, and 23.6% in the conventional oxygen therapy group). The requirement for tracheal intubation or mortality within 30 days was significantly lower with CPAP (36.3%; 137 of 377 participants) vs conventional oxygen therapy (44.4%; 158 of 356 participants) (absolute difference, -8% [95% CI, -15% to -1%], P = .03), but was not significantly different with HFNO (44.3%; 184 of 415 participants) vs conventional oxygen therapy (45.1%; 166 of 368 participants) (absolute difference, -1% [95% CI, -8% to 6%], P = .83). Adverse events occurred in 34.2% (130/380) of participants in the CPAP group, 20.6% (86/418) in the HFNO group, and 13.9% (66/475) in the conventional oxygen therapy group. Conclusions and Relevance: Among patients with acute hypoxemic respiratory failure due to COVID-19, an initial strategy of CPAP significantly reduced the risk of tracheal intubation or mortality compared with conventional oxygen therapy, but there was no significant difference between an initial strategy of HFNO compared with conventional oxygen therapy. The study may have been underpowered for the comparison of HFNO vs conventional oxygen therapy, and early study termination and crossover among the groups should be considered when interpreting the findings. Trial Registration: isrctn.org Identifier: ISRCTN16912075.


Assuntos
COVID-19/complicações , Pressão Positiva Contínua nas Vias Aéreas , Intubação Intratraqueal , Ventilação não Invasiva/métodos , Oxigenoterapia/métodos , Insuficiência Respiratória/terapia , Adulto , COVID-19/mortalidade , Cânula , Feminino , Mortalidade Hospitalar , Humanos , Intubação Intratraqueal/estatística & dados numéricos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Insuficiência Respiratória/etiologia
4.
Thorax ; 76(11): 1108-1116, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33859049

RESUMO

BACKGROUND: The optimal interface for the delivery of home non-invasive ventilation (NIV) to treat chronic respiratory failure has not yet been determined. The aim of this individual participant data (IPD) meta-analysis was to compare the effect of nasal and oronasal masks on treatment efficacy and adherence in patients with COPD and obesity hypoventilation syndrome (OHS). METHODS: We searched Medline and Cochrane Central Register of Controlled Trials for prospective randomised controlled trials (RCTs) of at least 1 month's duration, published between January 1994 and April 2019, that assessed NIV efficacy in patients with OHS and COPD. The main outcomes were diurnal PaCO2, PaO2 and NIV adherence (PROSPERO CRD42019132398). FINDINGS: Of 1576 articles identified, 34 RCTs met the inclusion criteria and IPD were obtained for 18. Ten RCTs were excluded because only one type of mask was used, or mask data were missing. Data from 8 RCTs, including 290 IPD, underwent meta-analysis. Oronasal masks were used in 86% of cases. There were no differences between oronasal and nasal masks for PaCO2 (0.61 mm Hg (95% CI -2.15 to 3.38); p=0.68), PaO2 (-0.00 mm Hg (95% CI -4.59 to 4.58); p=1) or NIV adherence (0·29 hour/day (95% CI -0.74 to 1.32); p=0.58). There was no interaction between the underlying pathology and the effect of mask type on any outcome. INTERPRETATION: Oronasal masks are the most used interface for the delivery of home NIV in patients with OHS and COPD; however, there is no difference in the efficacy or tolerance of oronasal or nasal masks.


Assuntos
Ventilação não Invasiva , Insuficiência Respiratória , Humanos , Hipercapnia , Máscaras , Respiração Artificial , Insuficiência Respiratória/terapia
5.
Eur Respir J ; 57(3)2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33214202

RESUMO

Clinical activities regarding sleep disordered breathing (SDB) have been sharply interrupted during the initial phase of the coronavirus disease 2019 (COVID-19) epidemic throughout Europe. In the past months, activities have gradually restarted, according to epidemiological phase of COVID-19 and national recommendations. The recent increase in cases throughout Europe demands a reconsideration of management strategies of SDB accordingly. Diagnosis of SDB and initiation of treatment pose some specific problems to be addressed to preserve the safety of patients and health personnel. This perspective document by a group of European sleep experts aims to summarise some different approaches followed in Europe and United States, which reflect national recommendations according to the epidemiological phase of the COVID-19 infection. Respiratory sleep medicine is likely to change in the near future, and use of telemedicine will grow to avoid unnecessary risks and continue to provide optimal care to patients. In addition, the document covers paediatric sleep studies and indications for titration of noninvasive ventilation, as well as precautions to be followed by patients who are already on positive airway pressure treatment. A single consensus document developed by the European Respiratory Society and national societies would be desirable to harmonise SDB management throughout Europe.


Assuntos
COVID-19 , Laboratórios/organização & administração , Pneumologia/organização & administração , Síndromes da Apneia do Sono/diagnóstico , COVID-19/epidemiologia , Europa (Continente)/epidemiologia , Humanos
6.
Eur Respir J ; 57(4)2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33692120

RESUMO

INTRODUCTION: Hospitalised patients with coronavirus disease 2019 (COVID-19) as a result of SARS-CoV-2 infection have a high mortality rate and frequently require noninvasive respiratory support or invasive ventilation. Optimising and standardising management through evidence-based guidelines may improve quality of care and therefore patient outcomes. METHODS: A task force from the European Respiratory Society and endorsed by the Chinese Thoracic Society identified priority interventions (pharmacological and non-pharmacological) for the initial version of this "living guideline" using the PICO (population, intervention, comparator, outcome) format. The GRADE approach was used for assessing the quality of evidence and strength of recommendations. Systematic literature reviews were performed, and data pooled by meta-analysis where possible. Evidence tables were presented and evidence to decision frameworks were used to formulate recommendations. RESULTS: Based on the available evidence at the time of guideline development (20 February, 2021), the panel makes a strong recommendation in favour of the use of systemic corticosteroids in patients requiring supplementary oxygen or ventilatory support, and for the use of anticoagulation in hospitalised patients. The panel makes a conditional recommendation for interleukin (IL)-6 receptor antagonist monoclonal antibody treatment and high-flow nasal oxygen or continuous positive airway pressure in patients with hypoxaemic respiratory failure. The panel make strong recommendations against the use of hydroxychloroquine and lopinavir-ritonavir. Conditional recommendations are made against the use of azithromycin, hydroxychloroquine combined with azithromycin, colchicine, and remdesivir, in the latter case specifically in patients requiring invasive mechanical ventilation. No recommendation was made for remdesivir in patients requiring supplemental oxygen. Further recommendations for research are made. CONCLUSION: The evidence base for management of COVID-19 now supports strong recommendations in favour and against specific interventions. These guidelines will be regularly updated as further evidence becomes available.


Assuntos
COVID-19/terapia , Hospitalização , Corticosteroides/uso terapêutico , Adulto , Humanos , Metanálise como Assunto , Respiração Artificial , Revisões Sistemáticas como Assunto
7.
Eur Respir J ; 56(3)2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32675211

RESUMO

BACKGROUND: Many people are dying from coronavirus disease 2019 (COVID-19), but consensus guidance on palliative care in COVID-19 is lacking. This new life-threatening disease has put healthcare systems under pressure, with the increased need of palliative care provided to many patients by clinicians who have limited prior experience in this field. Therefore, we aimed to make consensus recommendations for palliative care for patients with COVID-19 using the Convergence of Opinion on Recommendations and Evidence (CORE) process. METHODS: We invited 90 international experts to complete an online survey including stating their agreement, or not, with 14 potential recommendations. At least 70% agreement on directionality was needed to provide consensus recommendations. If consensus was not achieved on the first round, a second round was conducted. RESULTS: 68 (75.6%) experts responded in the first round. Most participants were experts in palliative care, respiratory medicine or critical care medicine. In the first round, consensus was achieved on 13 recommendations based upon indirect evidence and clinical experience. In the second round, 58 (85.3%) out of 68 of the first-round experts responded, resulting in consensus for the 14th recommendation. CONCLUSION: This multi-national task force provides consensus recommendations for palliative care for patients with COVID-19 concerning: advance care planning; (pharmacological) palliative treatment of breathlessness; clinician-patient communication; remote clinician-family communication; palliative care involvement in patients with serious COVID-19; spiritual care; psychosocial care; and bereavement care. Future studies are needed to generate empirical evidence for these recommendations.


Assuntos
Planejamento Antecipado de Cuidados/organização & administração , Infecções por Coronavirus , Cuidados Paliativos , Pandemias , Pneumonia Viral , Sistemas de Apoio Psicossocial , Terapia Respiratória/métodos , Comitês Consultivos , Betacoronavirus/isolamento & purificação , COVID-19 , Consenso , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/psicologia , Infecções por Coronavirus/terapia , Europa (Continente) , Humanos , Cuidados Paliativos/métodos , Cuidados Paliativos/organização & administração , Pneumonia Viral/diagnóstico , Pneumonia Viral/epidemiologia , Pneumonia Viral/psicologia , Pneumonia Viral/terapia , SARS-CoV-2 , Índice de Gravidade de Doença
8.
Respirology ; 25(3): 305-311, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31218793

RESUMO

BACKGROUND AND OBJECTIVE: Increases in Cheyne-Stokes respiration (CSR) cycle length (CL), lung-to-periphery circulation time (LPCT) and time to peak flow (TTPF) may reflect impaired cardiac function. This retrospective analysis used an automatic algorithm to evaluate baseline CSR-related features and then determined whether these could be used to identify patients with systolic heart failure (HF) who experienced serious adverse events in the Treatment of Sleep-Disordered Breathing with Predominant Central Sleep Apnea by Adaptive Servo Ventilation in Patients with Heart Failure (SERVE-HF) substudy. METHODS: A total of 280 patients had overnight diagnostic polysomnography data available; an automated algorithm was applied to quantify CSR-related features. RESULTS: Median baseline CL, LPCT and TTPF were similar in the control (n = 152) and adaptive servo-ventilation (ASV, n = 156) groups. In both groups, CSR-related features were significantly longer in patients who did (n = 129) versus did not (n = 140) experience a primary endpoint event (all-cause death, life-saving cardiovascular intervention or unplanned hospitalization for worsening HF): CL, 61.1 versus 55.1 s (P = 0.002); LPCT, 36.5 versus 31.5 s (P < 0.001); TTPF, 15.20 versus 13.35 s (P < 0.001), respectively. This finding was independent of treatment allocation. CONCLUSION: Patients with systolic HF and central sleep apnoea who experienced serious adverse events had longer CSR CL, LPCT and TTPF. Future studies should examine an independent role for CSR-related features to enable risk stratification in systolic HF.


Assuntos
Respiração de Cheyne-Stokes/etiologia , Insuficiência Cardíaca Sistólica/complicações , Apneia do Sono Tipo Central/complicações , Idoso , Algoritmos , Respiração de Cheyne-Stokes/fisiopatologia , Feminino , Insuficiência Cardíaca Sistólica/fisiopatologia , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia , Respiração com Pressão Positiva/efeitos adversos , Respiração com Pressão Positiva/métodos , Estudos Retrospectivos , Apneia do Sono Tipo Central/fisiopatologia , Apneia do Sono Tipo Central/terapia , Taxa de Sobrevida
9.
N Engl J Med ; 373(12): 1095-105, 2015 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-26323938

RESUMO

BACKGROUND: Central sleep apnea is associated with poor prognosis and death in patients with heart failure. Adaptive servo-ventilation is a therapy that uses a noninvasive ventilator to treat central sleep apnea by delivering servo-controlled inspiratory pressure support on top of expiratory positive airway pressure. We investigated the effects of adaptive servo-ventilation in patients who had heart failure with reduced ejection fraction and predominantly central sleep apnea. METHODS: We randomly assigned 1325 patients with a left ventricular ejection fraction of 45% or less, an apnea-hypopnea index (AHI) of 15 or more events (occurrences of apnea or hypopnea) per hour, and a predominance of central events to receive guideline-based medical treatment with adaptive servo-ventilation or guideline-based medical treatment alone (control). The primary end point in the time-to-event analysis was the first event of death from any cause, lifesaving cardiovascular intervention (cardiac transplantation, implantation of a ventricular assist device, resuscitation after sudden cardiac arrest, or appropriate lifesaving shock), or unplanned hospitalization for worsening heart failure. RESULTS: In the adaptive servo-ventilation group, the mean AHI at 12 months was 6.6 events per hour. The incidence of the primary end point did not differ significantly between the adaptive servo-ventilation group and the control group (54.1% and 50.8%, respectively; hazard ratio, 1.13; 95% confidence interval [CI], 0.97 to 1.31; P=0.10). All-cause mortality and cardiovascular mortality were significantly higher in the adaptive servo-ventilation group than in the control group (hazard ratio for death from any cause, 1.28; 95% CI, 1.06 to 1.55; P=0.01; and hazard ratio for cardiovascular death, 1.34; 95% CI, 1.09 to 1.65; P=0.006). CONCLUSIONS: Adaptive servo-ventilation had no significant effect on the primary end point in patients who had heart failure with reduced ejection fraction and predominantly central sleep apnea, but all-cause and cardiovascular mortality were both increased with this therapy. (Funded by ResMed and others; SERVE-HF ClinicalTrials.gov number, NCT00733343.).


Assuntos
Doenças Cardiovasculares/mortalidade , Insuficiência Cardíaca Sistólica/complicações , Respiração com Pressão Positiva/métodos , Apneia do Sono Tipo Central/terapia , Idoso , Doenças Cardiovasculares/etiologia , Feminino , Insuficiência Cardíaca Sistólica/fisiopatologia , Insuficiência Cardíaca Sistólica/terapia , Hospitalização , Humanos , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Respiração com Pressão Positiva/efeitos adversos , Apneia do Sono Tipo Central/complicações , Volume Sistólico , Falha de Tratamento
11.
Am J Respir Crit Care Med ; 195(9): 1140-1149, 2017 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-28459325

RESUMO

The evolution of home mechanical ventilation is an intertwined chronicle of negative and positive pressure modes and their role in managing ventilatory failure in neuromuscular diseases and other chronic disorders. The uptake of noninvasive positive pressure ventilation has resulted in widespread growth in home ventilation internationally and fewer patients being ventilated invasively. As with many applications of domiciliary medical technology, home ventilatory support has either led or run in parallel with acute hospital applications and has been influenced by medical and societal shifts in the approach to chronic care, the creation of community support teams, a preference of recipients to be treated at home, and economic imperatives. This review summarizes the trends and growing evidence base for ventilatory support outside the hospital.


Assuntos
Serviços de Assistência Domiciliar , Respiração Artificial/métodos , Esclerose Lateral Amiotrófica/terapia , Bronquiectasia/terapia , Fibrose Cística/terapia , História do Século XX , História do Século XXI , Serviços de Assistência Domiciliar/história , Humanos , Atrofia Muscular Espinal/terapia , Doenças Musculares/terapia , Distrofias Musculares/terapia , Ventilação não Invasiva/história , Ventilação não Invasiva/métodos , Respiração com Pressão Positiva/história , Doença Pulmonar Obstrutiva Crônica/terapia , Respiração Artificial/história
15.
Eur Respir J ; 50(2)2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28860264

RESUMO

This on-treatment analysis was conducted to facilitate understanding of mechanisms underlying the increased risk of all-cause and cardiovascular mortality in heart failure patients with reduced ejection fraction and predominant central sleep apnoea randomised to adaptive servo ventilation versus the control group in the SERVE-HF trial.Time-dependent on-treatment analyses were conducted (unadjusted and adjusted for predictive covariates). A comprehensive, time-dependent model was developed to correct for asymmetric selection effects (to minimise bias).The comprehensive model showed increased cardiovascular death hazard ratios during adaptive servo ventilation usage periods, slightly lower than those in the SERVE-HF intention-to-treat analysis. Self-selection bias was evident. Patients randomised to adaptive servo ventilation who crossed over to the control group were at higher risk of cardiovascular death than controls, while control patients with crossover to adaptive servo ventilation showed a trend towards lower risk of cardiovascular death than patients randomised to adaptive servo ventilation. Cardiovascular risk did not increase as nightly adaptive servo ventilation usage increased.On-treatment analysis showed similar results to the SERVE-HF intention-to-treat analysis, with an increased risk of cardiovascular death in heart failure with reduced ejection fraction patients with predominant central sleep apnoea treated with adaptive servo ventilation. Bias is inevitable and needs to be taken into account in any kind of on-treatment analysis in positive airway pressure studies.


Assuntos
Doenças Cardiovasculares/mortalidade , Insuficiência Cardíaca , Apneia do Sono Tipo Central , Causas de Morte , Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Pressão Positiva Contínua nas Vias Aéreas/métodos , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Apneia do Sono Tipo Central/complicações , Apneia do Sono Tipo Central/diagnóstico , Apneia do Sono Tipo Central/fisiopatologia , Apneia do Sono Tipo Central/terapia , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/fisiopatologia
17.
Respirology ; 22(7): 1343-1349, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28508568

RESUMO

BACKGROUND AND OBJECTIVE: A good mask fit, avoiding air leaks and pressure effects on the skin are key elements for a successful noninvasive ventilation (NIV). However, delivering practical training for NIV is challenging, and it takes time to build experience and competency. This study investigated whether a pressure sensing system with real-time visual feedback improved mask fitting. METHODS: During an NIV training session, 30 healthcare professionals (14 trained in mask fitting and 16 untrained) performed two mask fittings on the same healthy volunteer in a randomized order: one using standard mask-fitting procedures and one with additional visual feedback on mask pressure on the nasal bridge. Participants were required to achieve a mask fit with low mask pressure and minimal air leak (<10 L/min). Pressure exerted on the nasal bridge, perceived comfort of mask fit and staff- confidence were measured. RESULTS: Compared with standard mask fitting, a lower pressure was exerted on the nasal bridge using the feedback system (71.1 ± 17.6 mm Hg vs 63.2 ± 14.6 mm Hg, P < 0.001). Both untrained and trained healthcare professionals were able to reduce the pressure on the nasal bridge (74.5 ± 21.2 mm Hg vs 66.1 ± 17.4 mm Hg, P = 0.023 and 67 ± 12.1 mm Hg vs 60 ± 10.6 mm Hg, P = 0.002, respectively) using the feedback system and self-rated confidence increased in the untrained group. CONCLUSION: Real-time visual feedback using pressure sensing technology supported healthcare professionals during mask-fitting training, resulted in a lower pressure on the skin and better mask fit for the volunteer, with increased staff confidence.


Assuntos
Retroalimentação Sensorial , Máscaras , Ventilação não Invasiva/instrumentação , Insuficiência Respiratória/terapia , Adulto , Estudos Cross-Over , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Nariz , Pressão , Estudos Prospectivos