Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Pacing Clin Electrophysiol ; 46(7): 615-622, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37120712

RESUMO

BACKGROUND: The safety and efficacy of leadless pacemakers (LP) in transcatheter aortic valve implant (TAVI) patients is not well known due to paucity of data. Herein, we compared outcomes between leadless pacemakers to traditional dual chamber pacemakers (DCP) following TAVI. METHODS: A single-center retrospective study was conducted, including a total of 27 patients with LP and 33 patients with DCP after TAVI between November 2013 and May 2021. We compared baseline demographics, pacemaker indications, complication rates, percent pacing, and ejection fractions. RESULTS: Leading indications for pacemaker implant were complete heart block (74% LP, 73% DCP) and high degree atrioventricular block (26% LP, 21% DCP). Twenty-two (82%) LP patients had devices implanted in the right ventricular septal-apex. Three (9%) DCP patients required rehospitalization for pocket related complications. Zero pacemaker-related mortality was observed in both groups. Frequency of ventricular pacing and ejection fraction was similar between LP and DCP groups. CONCLUSION: From this single-center retrospective study, LP implant was feasible following TAVI and was found to have comparable performance to DCPs. LPs may be a reasonable alternative in TAVI patients where single ventricular pacing is indicated. Larger studies are required to validate these findings.


Assuntos
Estenose da Valva Aórtica , Bloqueio Atrioventricular , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Retrospectivos , Estimulação Cardíaca Artificial/efeitos adversos , Resultado do Tratamento , Marca-Passo Artificial/efeitos adversos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia
2.
J Artif Organs ; 21(3): 285-292, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29766321

RESUMO

Continuous-flow left ventricular assist devices (CF-LVADs) are increasingly being used to treat advanced, refractory chronic heart failure. Herein, we sought to determine the incidence of postoperative acute kidney injury (AKI) in axial-flow (HeartMate II; HM-II) and centrifugal-flow (HVAD) CF-LVAD recipients, as well as the effect of AKI on mortality. The study cohort comprised 520 patients who received a HM-II (n = 398) or HVAD (n = 122) at our center between November 2003 and March 2016. Their records were reviewed to determine the incidence of RIFLE-defined AKI after LVAD implantation. We compared the perioperative characteristics, postoperative complications, and survival rates of the patients with and without AKI and differentiated the outcomes based on device type (HM-II or HVAD). Seventy-five patients (14.4%) developed AKI postoperatively. Patients with AKI after LVAD implantation had significantly reduced survival compared to patients without AKI (p = 0.01). Cox proportional hazards models showed that AKI was a significant independent predictor of mortality (HR = 1.54, p = 0.03). Preoperative mechanical circulatory support and prolonged cardiopulmonary bypass time were independent predictors of AKI. The incidence of AKI was similar for HM-II and HVAD recipients (p = 0.25). There was no significant difference in AKI rates for the HM-II and HVAD recipients. Developing AKI adversely affected survival.


Assuntos
Injúria Renal Aguda/etiologia , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Complicações Pós-Operatórias , Injúria Renal Aguda/epidemiologia , Desenho de Equipamento , Falha de Equipamento , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Estados Unidos/epidemiologia
3.
J Cardiovasc Electrophysiol ; 27(1): 95-101, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26377813

RESUMO

INTRODUCTION: Patients undergoing catheter ablation for ventricular tachycardia (VT) may require epicardial mapping. In patients with end-stage heart failure, hybrid surgical epicardial mapping and ablation during the period of left ventricular assist device (LVAD) implantation may be considered in select patients to reduce post-LVAD ventricular tachycardia. METHODS AND RESULTS: From March 2009 to October 2012, 5 patients (4 men and 1 woman, age range 52-73 years) underwent open chest electrophysiology study and epicardial mapping for recurrent ventricular tachycardia while the heart was exposed during the period of LVAD implantation. Epicardial mapping was considered if patients had recurrent VT despite failed prior endocardial ablation and/or electrocardiogram (EKG) features of an epicardial exit. Activation and/or a substrate mapping approach were employed during all procedures. Three of 5 patients (60%) had acute procedural success. In all patients, VT was either eliminated or significantly reduced with epicardial ablation. One patient had mediastinal bleeding delaying sternal closure. During a follow-up period of 363 ± 368 days, 4 patients died due to nonarrhythmic causes. CONCLUSIONS: Open-chest hybrid epicardial mapping and ablation for recurrent VT is feasible and can be considered in select patients during the period of LVAD implantation.


Assuntos
Ablação por Cateter , Mapeamento Epicárdico , Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Implantação de Prótese/instrumentação , Taquicardia Ventricular/cirurgia , Função Ventricular Esquerda , Idoso , Ablação por Cateter/efeitos adversos , Eletrocardiografia , Mapeamento Epicárdico/efeitos adversos , Estudos de Viabilidade , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Valor Preditivo dos Testes , Desenho de Prótese , Implantação de Prótese/efeitos adversos , Recidiva , Medição de Risco , Fatores de Risco , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Resultado do Tratamento
4.
JACC Adv ; 3(5): 100916, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38939630

RESUMO

Background: Vasoplegia after cardiac surgery is associated with adverse outcomes. However, the clinical effects of vasoplegia and the significance of its duration after continuous-flow left ventricular assist device (CF-LVAD) implantation are less known. Objectives: This study aimed to identify predictors of and outcomes from transient vs prolonged vasoplegia after CF-LVAD implantation. Methods: The study was a retrospective review of consecutive patients who underwent CF-LVAD implantation between January 1, 2005, and December 31, 2017. Vasoplegia was defined as the presence of all of the following: mean arterial pressure ≤65 mm Hg, vasopressor (epinephrine, norepinephrine, vasopressin, or dopamine) use for >6 hours within the first 24 hours postoperatively, cardiac index ≥2.2 L/min/m2 and systemic vascular resistance <800 dyne/s/cm5, and vasodilatory shock not attributable to other causes. Prolonged vasoplegia was defined as that lasting 12 to 24 hours; transient vasoplegia was that lasting 6 to <12 hours. Patient characteristics, outcomes, and risk factors were analyzed. Results: Of the 600 patients who underwent CF-LVAD implantation during the study period, 182 (30.3%) developed vasoplegia. Mean patient age was similar between the vasoplegia and no-vasoplegia groups. Prolonged vasoplegia (n = 78; 13.0%), compared with transient vasoplegia (n = 104; 17.3%), was associated with greater 30-day mortality (16.7% vs 5.8%; P = 0.02). Risk factors for prolonged vasoplegia included preoperative dialysis and elevated body mass index. Conclusions: Compared with vasoplegia overall, prolonged vasoplegia was associated with worse survival after CF-LVAD implantation. Treatment to avoid or minimize progression to prolonged vasoplegia may be warranted.

5.
Tex Heart Inst J ; 50(5)2023 10 20.
Artigo em Inglês | MEDLINE | ID: mdl-37876039

RESUMO

This report highlights survival and the patient's perspective after prolonged venovenous extracorporeal membrane oxygenation (ECMO) for COVID-19-related respiratory failure. A 36-year-old man with COVID-19 presented with fever, anosmia, and hypoxia. After respiratory deterioration necessitating intubation and lung-protective ventilation, he was referred for ECMO. After 3 days of conventional venovenous ECMO, he required multiple creative cannulation configurations. Adequate sedation and recurrent bradycardia were persistent challenges. After 149 consecutive days of ECMO, he recovered native lung function and was weaned from mechanical ventilation. This represents the longest-duration ECMO support in a survivor of COVID-19 yet reported. Necessary strategies included unconventional cannulation and flexible anticoagulation.


Assuntos
COVID-19 , Oxigenação por Membrana Extracorpórea , Insuficiência Respiratória , Masculino , Humanos , Adulto , Respiração Artificial , Insuficiência Respiratória/etiologia , Insuficiência Respiratória/terapia , Pulmão/diagnóstico por imagem
6.
JTCVS Tech ; 13: 92-100, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36466372

RESUMO

Objective: Robot-assisted coronary artery bypass (RCAB) is typically not offered to higher risk patients with reduced cardiopulmonary function, critical coronary artery disease, and challenging chest wall anatomy. In this study, we report the novel use of nonemergency intraoperative peripheral extracorporeal membrane oxygenation as partial cardiopulmonary support during RCAB for patients who were considered high-risk candidates for conventional CAB and at the same time not eligible for RCAB without cardiopulmonary support. Methods: Forty-five high risk patients (mean age, 68 years; Society of Thoracic Surgeons score, 6.27%; ejection fraction, 45%) underwent RCAB with nonemergency peripheral extracorporeal membrane oxygenation support for the following indications: inability to tolerate single-lung ventilation (n = 17; 38%), low ejection fraction <35% (n = 17; 38%), inadequate exposure of internal thoracic artery (n = 24; 53%), critical coronary artery disease (n = 16; 36%), and hemodynamic instability after anesthesia induction (n = 3; 7%). Following robotic internal thoracic artery takedown, all patients had beating heart minimally invasive direct CAB through a 2-inch minithoracotomy. Results: Up to 30 days, there were no strokes (0%), myocardial infarctions (0%), or access vessel complications (0%). One noncardiac related mortality (2.2%) was related to hemodialysis access issues in a patient with preexisting end-stage renal disease. One redo-CAB (2.2%) patient required sternotomy to locate the target vessel. Thirty-four (75.6%) patients were extubated within 6 hours of surgery. Conclusions: Our results examine the feasibility of using peripheral extracorporeal membrane oxygenation during RCAB for high-risk patients who otherwise had limited options. The use of peripheral extracorporeal membrane oxygenation in RCAB can potentially expand the surgical treatment options in high-risk coronary artery disease patients.

7.
Interact Cardiovasc Thorac Surg ; 34(3): 470-477, 2022 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-34966937

RESUMO

OBJECTIVES: Dialysis is considered a contraindication to continuous-flow left ventricular assist device (CF-LVAD) implantation. We evaluated clinical outcomes and survival in carefully selected, low-risk patients with renal failure who required dialysis before CF-LVAD implantation. METHODS: We extracted medical record data of patients who underwent CF-LVAD placement at our centre between 1 January 2006 and 31 August 2017, with 2 clinical scenarios: those who required long-term (>14 days) dialysis and those who required short-term (≤14 days) dialysis immediately before implantation. Demographic, clinical and intraoperative characteristics and survival outcomes were assessed. RESULTS: Of 621 patients who underwent CF-LVAD implantation during the study period, 31 underwent dialysis beforehand. Of these, 17 required long-term dialysis (13 haemodialysis, 4 peritoneal dialysis), and 14 underwent short-term haemodialysis. Compared with the long-term dialysis patients, the short-term dialysis patients were more likely to be Interagency Registry for Mechanically Assisted Circulatory Support profile 1-2 (92.9% vs 70.6%; P < 0.001), to have needed preoperative mechanical circulatory support (78.6% vs 70.6%; P < 0.01) and to have higher in-hospital mortality (85.7% vs 29.4%; P = 0.01). Patients stable on long-term dialysis had acceptable overall survival and markedly better 6-month and 1-year survival than those with short-term dialysis before implantation (64.7% vs 14.3% and 58.8% vs 7.1%, respectively; P < 0.001). CONCLUSIONS: Carefully selected patients who are stable on long-term dialysis have acceptable survival rates after CF-LVAD implantation. Patients with acute renal failure had much poorer outcomes than those with chronic end-stage renal disease.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Humanos , Diálise Renal/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
8.
ASAIO J ; 68(12): 1443-1449, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36150083

RESUMO

Patients with severe refractory hypoxemic respiratory failure may benefit from extracorporeal membrane oxygenation (ECMO) for salvage therapy. The Coronavirus disease 2019 (COVID-19) pandemic offered three high-volume independent ECMO programs at a large medical center the chance to collaborate to optimize ECMO care at the beginning of the pandemic in Spring 2020. Between March 15, 2020, and May 30, 2020, 3,615 inpatients with COVID-19 were treated at the Texas Medical Center. During this time, 35 COVID-19 patients were cannulated for ECMO, all but one in a veno-venous configuration. At hospital discharge, 23 (66%) of the 35 patients were alive. Twelve patients died of vasodilatory shock (n = 9), intracranial hemorrhage (n = 2), and cannulation-related bleeding and multiorgan dysfunction (n = 1). The average duration of ECMO was 13.6 days in survivors and 25.0 days in nonsurvivors ( p < 0.04). At 1 year follow-up, all 23 discharged patients were still alive, making the 1 year survival rate 66% (23/35). At 2 years follow-up, the overall rate of survival was 63% (22/35). Of those patients who survived 2 years, all were at home and alive and well at follow-up.


Assuntos
COVID-19 , Oxigenação por Membrana Extracorpórea , Humanos , COVID-19/terapia , Seguimentos , Texas/epidemiologia , Hospitais
9.
Sci Rep ; 11(1): 14505, 2021 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-34267244

RESUMO

Modern high-throughput sequencing technologies provide low-cost microbiome survey data across all habitats of life at unprecedented scale. At the most granular level, the primary data consist of sparse counts of amplicon sequence variants or operational taxonomic units that are associated with taxonomic and phylogenetic group information. In this contribution, we leverage the hierarchical structure of amplicon data and propose a data-driven and scalable tree-guided aggregation framework to associate microbial subcompositions with response variables of interest. The excess number of zero or low count measurements at the read level forces traditional microbiome data analysis workflows to remove rare sequencing variants or group them by a fixed taxonomic rank, such as genus or phylum, or by phylogenetic similarity. By contrast, our framework, which we call trac (tree-aggregation of compositional data), learns data-adaptive taxon aggregation levels for predictive modeling, greatly reducing the need for user-defined aggregation in preprocessing while simultaneously integrating seamlessly into the compositional data analysis framework. We illustrate the versatility of our framework in the context of large-scale regression problems in human gut, soil, and marine microbial ecosystems. We posit that the inferred aggregation levels provide highly interpretable taxon groupings that can help microbiome researchers gain insights into the structure and functioning of the underlying ecosystem of interest.


Assuntos
Infecções por HIV/microbiologia , Microbiota , Modelos Teóricos , Microbiologia do Solo , Microbiologia da Água , Archaea/genética , Bactérias/genética , Bases de Dados Factuais , Fezes/microbiologia , Microbioma Gastrointestinal , Infecções por HIV/imunologia , Humanos , Concentração de Íons de Hidrogênio , Receptores de Lipopolissacarídeos/imunologia , Microbiota/genética , Microbiota/fisiologia , RNA Ribossômico 16S , Salinidade , Solo/química
10.
J Interv Card Electrophysiol ; 62(1): 49-56, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32949304

RESUMO

PURPOSE: Assess if timing of removal of a percutaneous left ventricular assist device (pLVAD) after ventricular tachycardia (VT) ablation alters patient outcomes. METHODS: Sixty-nine patients underwent pLVAD support. Patients were divided into early (< 24 h, n = 43) and delayed (≥ 24 h, n = 26) removal groups after ablation. Factors for delayed pLVAD removal and predictors of 90-day mortality were analyzed. RESULTS: The delayed removal group had lower LVEF (27.1 ± 9.3% vs. 20.6 ± 5.4%, p = 0.002), greater percentage LVEF < 25% (58.1% vs. 84.6%, p = 0.02), and more VT storm (41.9% vs. 96.2%, p < 0.001). Ventricular fibrillation (VF) was induced in 9/69 (13%), with incidence higher in delayed removal group (27% vs. 5%, p = 0.002). VT storm (OR = 34.72, 95% CI, 4.30-280.33; p = 0.001), LVEF < 25% (OR = 3.95, 95% CI, 1.16-13.48; p = 0.03), and VF induced during ablation (OR = 9.25, 95% CI, 1.71-50.0; p = 0.01) were associated with delayed pLVAD removal in univariate analysis. Delayed pLVAD removal had a significantly higher 90-day mortality rate (2.3% vs 30.2%; p < 0.001). Univariate Cox proportional hazard regression analysis revealed delayed pLVAD removal was a significant predictor of 90-day mortality. CONCLUSIONS: Prolonged pLVAD insertion (≥ 24 h) after VT ablation was associated with VT storm, LVEF < 25%, and VF induced during ablation. Delayed pLVAD removal was a significant predictor of 90-day mortality in patients undergoing VT ablation.


Assuntos
Ablação por Cateter , Coração Auxiliar , Taquicardia Ventricular , Arritmias Cardíacas , Humanos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
11.
Int J Cardiol ; 329: 50-55, 2021 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-33359282

RESUMO

BACKGROUND: Chest radiation therapy (CRT) for malignant thoracic neoplasms is associated with development of valvular heart disease years later. As previous radiation exposure can complicate surgical treatment, transcatheter aortic valve replacement (TAVR) has emerged as an alternative. However, outcomes data are lacking for TAVR patients with a history of CRT. METHODS: We conducted a retrospective study of all patients who underwent a TAVR procedure at a single institution between September 2012 and November 2018. Among 1341 total patients, 50 had previous CRT. These were propensity-matched in a 1:2 ratio to 100 patients without history of CRT. Thirty-day adverse events were analyzed with generalized estimating equation models. Overall mortality was analyzed with stratified Cox regression modelling. RESULTS: Median clinical follow-up was 24 months (interquartile range [IQR], 12-44 months). There was no difference between CRT and non-CRT patients in overall mortality (hazard ratio [HR] 0.84 [0.37-1.90], P = 0.67), 30-day mortality (HR 3.1 [0.49-20.03], P = 0.23), or 30-day readmission rate (HR 1.0 [0.43-2.31], P = 1). There were no differences in the rates of most adverse events, but patients with CRT history had higher rates of postprocedural respiratory failure (HR 3.63 [1.32-10.02], P = 0.01) and permanent pacemaker implantation (HR 2.84 [1.15-7.01], P = 0.02). CONCLUSIONS: For patients with aortic valve stenosis and previous CRT, TAVR is safe and effective, with outcomes similar to those in the general aortic stenosis population. Patients with history of CRT are more likely to have postprocedural respiratory failure and to require permanent pacemaker implantation.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Readmissão do Paciente , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
12.
JACC Basic Transl Sci ; 6(4): 331-345, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33681537

RESUMO

There is ongoing debate as to whether cardiac complications of coronavirus disease-2019 (COVID-19) result from myocardial viral infection or are secondary to systemic inflammation and/or thrombosis. We provide evidence that cardiomyocytes are infected in patients with COVID-19 myocarditis and are susceptible to severe acute respiratory syndrome coronavirus 2. We establish an engineered heart tissue model of COVID-19 myocardial pathology, define mechanisms of viral pathogenesis, and demonstrate that cardiomyocyte severe acute respiratory syndrome coronavirus 2 infection results in contractile deficits, cytokine production, sarcomere disassembly, and cell death. These findings implicate direct infection of cardiomyocytes in the pathogenesis of COVID-19 myocardial pathology and provides a model system to study this emerging disease.

14.
Ann Thorac Surg ; 109(6): e439-e440, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31715152

RESUMO

Anticoagulation with unfractionated heparin is vital to reduce the risk of thromboembolic events during cardiopulmonary bypass and left ventricular assist device placement. However patients with heparin-induced thrombocytopenia are at risk of developing immune-mediated thrombotic events. We describe 2 patients with heparin-induced thrombocytopenia confirmed via serotonin release assay who were successfully treated with plasmapheresis exchange before left ventricular assist device placement.


Assuntos
Coração Auxiliar , Heparina/efeitos adversos , Plasmaferese/métodos , Trombocitopenia/induzido quimicamente , Trombose/terapia , Anticoagulantes/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Trombocitopenia/complicações , Trombose/etiologia
15.
ASAIO J ; 66(1): 64-68, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-30507849

RESUMO

Implantable continuous-flow left ventricular assist devices (CF-LVADs) are used for long-term LV support in bridging patients to heart transplantation or as destination therapy. With prolonged support times, some patients will have repeat complications necessitating multiple device exchanges. To elucidate the safety and efficacy of repeat device exchange, we retrospectively reviewed data from 25 patients who underwent two or more CF-LVAD implantations between July 2005 and August 2017. Indications for exchange were thrombus/hemolysis (n = 8, 32%), electromechanical device malfunction (n = 14, 56%), and infection (n = 3, 12%). The implanted devices were the HeartMate II (n = 13, 52%), the HeartWare HVAD (n = 11, 44%), and the Jarvik 2000 (n = 1, 4%). Average hospital length of stay was 44 days (range 4-221 days), and 17 patients (68%) survived to discharge. Average duration of support after the most recent LVAD implantation was 802 days (range 1-3,229 days). Overall survival was 72% at 1 year and 60% at 2 years. Postoperative complications included respiratory failure in five patients (20%), device infection in five (20%), bleeding requiring reoperation in four (16%), neurologic dysfunction in four (16%), and acute renal failure in two (8%). Overall, our data suggest that repeat LVAD exchange is a feasible option for patients with recurrent device-related complications.


Assuntos
Coração Auxiliar , Reoperação/mortalidade , Adolescente , Adulto , Idoso , Feminino , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Reoperação/efeitos adversos , Reoperação/métodos , Estudos Retrospectivos , Adulto Jovem
16.
bioRxiv ; 2020 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-33173875

RESUMO

Epidemiological studies of the COVID-19 pandemic have revealed evidence of cardiac involvement and documented that myocardial injury and myocarditis are predictors of poor outcomes. Nonetheless, little is understood regarding SARS-CoV-2 tropism within the heart and whether cardiac complications result directly from myocardial infection. Here, we develop a human engineered heart tissue model and demonstrate that SARS-CoV-2 selectively infects cardiomyocytes. Viral infection is dependent on expression of angiotensin-I converting enzyme 2 (ACE2) and endosomal cysteine proteases, suggesting an endosomal mechanism of cell entry. After infection with SARS-CoV-2, engineered tissues display typical features of myocarditis, including cardiomyocyte cell death, impaired cardiac contractility, and innate immune cell activation. Consistent with these findings, autopsy tissue obtained from individuals with COVID-19 myocarditis demonstrated cardiomyocyte infection, cell death, and macrophage-predominate immune cell infiltrate. These findings establish human cardiomyocyte tropism for SARS-CoV-2 and provide an experimental platform for interrogating and mitigating cardiac complications of COVID-19.

17.
Tex Heart Inst J ; 35(1): 38-41, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18427650

RESUMO

Contrast echocardiography is recognized to be a safe, effective technique for evaluating the endocardial border and left ventricular function in patients who have suboptimal non-contrast echocardiograms. However, its use in diagnosing right-heart conditions is less well established. Herein, we report our experience with the use of contrast echocardiography for diagnosing 3 distinct right-sided heart conditions (hypokinesis of the right ventricular free wall, severe tricuspid regurgitation, and cardiac tamponade) in patients who had suboptimal echocardiograms. Further studies should be done to validate the use of contrast echocardiography for diagnosing right-heart conditions.


Assuntos
Tamponamento Cardíaco/diagnóstico por imagem , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Disfunção Ventricular Direita/diagnóstico por imagem , Ecocardiografia Doppler em Cores , Feminino , Fluorocarbonos , Humanos , Masculino , Microesferas , Pessoa de Meia-Idade , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico , Trombose Venosa/diagnóstico por imagem , Disfunção Ventricular Direita/etiologia
18.
Tex Heart Inst J ; 35(3): 256-61, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18941642

RESUMO

Patients with Eisenmenger syndrome experience substantial morbidity and decreased survival rates. In advanced cases, lung transplantation with cardiac repair or heart-lung transplantation is often the only option. The efficacy of endothelin receptor antagonists in Eisenmenger syndrome, which has similar pathophysiology to idiopathic pulmonary hypertension, remains unknown.We retrospectively studied adults with congenital heart disease and Eisenmenger syndrome who were treated with endothelin receptor antagonists. Analysis included chart reviews of clinical evaluations, oxygen saturation levels, functional class, 6-minute walk distances, and pulmonary artery pressures. In the 24 patients studied, Eisenmenger syndrome was caused by ventricular septal defect (6 patients), atrial septal defect (5), atrioventricular canal defect (3), complex congenital heart disease (9), and patent ductus arteriosus (1).Eisenmenger syndrome was treated with bosentan (21 patients) and sitaxsentan (3 patients). On average, therapy lasted 19 +/- 12 months. Subsequently, mean 6-minute walk distances improved from 226 +/- 159 m to 351 +/- 113 m (P = 0.004), and World Health Organization functional class improved > or =1 grade (P < 0.0001). Oxygen saturations increased on therapy from 80.5% to 87% (P < 0.0001). Pulmonary arterial systolic pressures decreased from 97 +/- 21 mmHg to 78 +/- 27 mmHg, and mean pressures from 59 +/- 16 mmHg to 47 +/- 17 mmHg (both P < 0.0001). Neither major complications from therapy nor changes in pulmonary capillary wedge pressure occurred.Endothelin receptor antagonists may play an important role in improving 6-minute walk distance, oxygen saturation, pulmonary artery pressures, and symptoms in adults who have congenital heart defects and Eisenmenger syndrome.


Assuntos
Anti-Hipertensivos/uso terapêutico , Complexo de Eisenmenger/tratamento farmacológico , Antagonistas do Receptor de Endotelina A , Antagonistas do Receptor de Endotelina B , Teste de Esforço/efeitos dos fármacos , Cardiopatias Congênitas/tratamento farmacológico , Isoxazóis/uso terapêutico , Oxigênio/sangue , Sulfonamidas/uso terapêutico , Tiofenos/uso terapêutico , Administração Oral , Adulto , Anti-Hipertensivos/efeitos adversos , Bosentana , Relação Dose-Resposta a Droga , Esquema de Medicação , Feminino , Humanos , Isoxazóis/efeitos adversos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tiofenos/efeitos adversos
19.
JACC Clin Electrophysiol ; 4(2): 257-264, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29749947

RESUMO

OBJECTIVES: The aim of this study was to evaluate the incidence, predictors, and associated mortality of pre-implantation, early, and late ventricular arrhythmias (VAs) in patients receiving continuous-flow left ventricular assist devices (CFLVADs). BACKGROUND: VAs are common both pre- and post-implantation of left ventricular assist devices. Limited data exist on their prognostic impact in contemporary CFLVADs. METHODS: A retrospective review was performed to identify patients who underwent CFLVAD implantation between 2000 and 2015 with 2 years of follow-up. All VAs, defined as ventricular fibrillation, ventricular tachycardia lasting >30 s, or a ventricular rhythm requiring defibrillation, were analyzed. VAs occurring within 30 days of implantation were defined as early. Recorded outcomes included death and receipt of cardiac transplant. RESULTS: A total of 517 patients were included for analysis. Early VAs were associated with a significant reduction in survival (hazard ratio: 1.83; 95% confidence interval: 1.28 to 2.61; p = 0.001) compared with patients with late or no VAs. Pre-implantation variables independently predictive of early VAs included prior cardiac surgery (odds ratio: 1.90; 95% confidence interval: 1.09 to 3.32; p = 0.023) and pre-CFLVAD ventricular tachycardia storm (odds ratio: 3.15; 95% confidence interval: 1.49 to 6.69; p = 0.003). The incidence of early VAs from 2000 to 2007 was as high as 47%, whereas the highest incidence from 2008 to 2015 was <22%. CONCLUSIONS: VAs within 30 days after CFLVAD implantation are associated with an increased risk for death. Predictors of early VAs include prior cardiac surgery and pre-CFLVAD ventricular tachycardia storm. Temporal trends have shown a decrease in VA from 2000 to 2015. Strategies to reduce arrhythmia burden shortly after CFLVAD implantation warrant further investigation.


Assuntos
Arritmias Cardíacas , Coração Auxiliar , Idoso , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/mortalidade , Feminino , Ventrículos do Coração/fisiopatologia , Coração Auxiliar/efeitos adversos , Coração Auxiliar/estatística & dados numéricos , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco
20.
Am J Cardiol ; 99(12): 1755-6, 2007 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-17560889

RESUMO

The TandemHeart percutaneous left ventricular assist device is a left atrial-to-femoral artery bypass system that can be implanted percutaneously within 30 minutes and provides active circulatory support. The TandemHeart has been used mainly for temporary hemodynamic assistance during high-risk coronary interventions and postcardiotomy heart failure. This report describes initial experience with this device as a successful bridge to cardiac recovery in 3 patients with acute myocarditis. All patients presented with severe cardiogenic shock (mean cardiac index 1.1 L/min/m2), and end-organ perfusion could not be maintained despite intra-aortic balloon counterpulsation and the maximal use of vasopressive agents. The patients were successfully bridged to myocardial recovery with the TandemHeart (mean duration of support 5 days, range 2 to 8). The only complication was a short episode of ventricular fibrillation during device placement in 1 patient, which did not result in any morbidity or mortality. All patients were discharged home (mean duration of stay 15 days). In conclusion, the TandemHeart proved to be a safe and effective bridge to myocardial recovery in these patients with acute myocarditis.


Assuntos
Coração Auxiliar , Miocardite/terapia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA