Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
Nature ; 450(7170): 657-60, 2007 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-18046400

RESUMO

The atmosphere and ionosphere of Venus have been studied in the past by spacecraft with remote sensing or in situ techniques. These early missions, however, have left us with questions about, for example, the atmospheric structure in the transition region from the upper troposphere to the lower mesosphere (50-90 km) and the remarkably variable structure of the ionosphere. Observations become increasingly difficult within and below the global cloud deck (<50 km altitude), where strong absorption greatly limits the available investigative spectrum to a few infrared windows and the radio range. Here we report radio-sounding results from the first Venus Express Radio Science (VeRa) occultation season. We determine the fine structure in temperatures at upper cloud-deck altitudes, detect a distinct day-night temperature difference in the southern middle atmosphere, and track day-to-day changes in Venus' ionosphere.

2.
Rev Sci Instrum ; 94(12)2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38117203

RESUMO

We present the development of a flexible tape-drive target system to generate and control secondary high-intensity laser-plasma sources. Its adjustable design permits the generation of relativistic MeV particles and x rays at high-intensity (i.e., ≥1 × 1018 W cm-2) laser facilities, at high repetition rates (>1 Hz). The compact and robust structure shows good mechanical stability and a high target placement accuracy (<4 µm RMS). Its compact and flexible design allows for mounting in both the horizontal and vertical planes, which makes it practical for use in cluttered laser-plasma experimental setups. The design permits ∼170° of access on the laser-driver side and 120° of diagnostic access at the rear. A range of adapted apertures have been designed and tested to be easily implemented to the targetry system. The design and performance testing of the tape-drive system in the context of two experiments performed at the COMET laser facility at the Lawrence Livermore National Laboratory and at the Advanced Lasers and Extreme Photonics (ALEPH) facility at Colorado State University are discussed. Experimental data showing that the designed prototype is also able to both generate and focus high-intensity laser-driven protons at high repetition rates are also presented.

3.
Rev Sci Instrum ; 94(2): 023507, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36859040

RESUMO

The PROBIES diagnostic is a new, highly flexible, imaging and energy spectrometer designed for laser-accelerated protons. The diagnostic can detect low-mode spatial variations in the proton beam profile while resolving multiple energies on a single detector or more. When a radiochromic film stack is employed for "single-shot mode," the energy resolution of the stack can be greatly increased while reducing the need for large numbers of films; for example, a recently deployed version allowed for 180 unique energy measurements spanning ∼3 to 75 MeV with <0.4 MeV resolution using just 20 films vs 180 for a comparable traditional film and filter stack. When utilized with a scintillator, the diagnostic can be run in high-rep-rate (>Hz rate) mode to recover nine proton energy bins. We also demonstrate a deep learning-based method to analyze data from synthetic PROBIES images with greater than 95% accuracy on sub-millisecond timescales and retrained with experimental data to analyze real-world images on sub-millisecond time-scales with comparable accuracy.

4.
Rev Sci Instrum ; 93(9): 093514, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36182503

RESUMO

A novel dual-energy fast neutron imaging technique is presented using short-pulse laser-driven neutron sources to leverage their inherent adaptive spectral control to enable 3D volume segmentation and reconstruction. Laser-accelerated ion beams incident onto secondary targets create directional, broadband, MeV-class neutrons. Synthetic radiographs are produced of multi-material objects using ion and neutron spectra derived from analytic and numerical models. It is demonstrated that neutron images generated from small changes to the neutron spectra, controlled by altering the initial laser conditions, are sufficient to isolate materials with differing attenuation coefficients. This is first demonstrated using a simplistic combinatorial isolation method and then by employing more advanced reconstruction algorithms to reduce artifacts and generate a segmentation volume of the constituent materials.

5.
Rev Sci Instrum ; 93(4): 043006, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35489905

RESUMO

A plasma mirror platform was developed for the OMEGA-EP facility to redirect beams, thus enabling more flexible experimental configurations as well as a platform that can be used in the future to improve laser contrast. The plasma mirror reflected a short pulse focusing beam at 22.5° angle of incidence onto a 12.5 µm thick Cu foil, generating Bremsstrahlung and kα x rays, and accelerating ions and relativistic electrons. By measuring these secondary sources, the plasma mirror key performance metrics of integrated reflectivity and optical quality are inferred. It is shown that for a 5 ± 2 ps, 310 J laser pulse, the plasma mirror integrated reflectivity was 62 ± 13% at an operating fluence of 1670 J cm-2, and that the resultant short pulse driven particle acceleration and x-ray generation indicate that the on target intensity was 3.1 × 1018 W cm-2, which is indicative of a good post-plasma mirror interaction beam optical quality. By deriving the plasma mirror performance metrics from the secondary source scalings, it was simultaneously demonstrated that the plasma mirror is ready for adoption in short pulse particle acceleration and high energy photon generation experiments using the OMEGA-EP system.

6.
Rev Sci Instrum ; 93(12): 123508, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36586893

RESUMO

We report recent single-shot spatiotemporal measurements of laser pulses, including pulse-front tilt (PFT) and spatial chirp, taken at the Compact Multipulse Terawatt laser at the Jupiter Laser Facility in Livermore, CA. STRIPED FISH, a device that measures the complete 3D electric field of fs to ps laser pulses on a single shot, was adapted to near infrared for these measurements. We present the design of the instrument used for these experiments, the on-shot measurements of systematic high-order PFT, and shot-to-shot variations in the measurements of spatiotemporal couplings. Finally, we simulate the effect of PFT in target normal sheath acceleration experiments. These simulations showed that pulse front tilt can steer hot electrons, shape the distribution of the accelerating sheath field, and increase the variability of cutoff energy in the resulting proton spectra. While these effects may be detrimental to experimental accuracy if the pulse front tilt is left unmeasured, hot electron steering shows promise for precision manipulation of the particle source for a range of applications, including irradiation of secondary targets for opacity measurements, radiography, or neutron generation.

7.
Rev Sci Instrum ; 92(7): 075101, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34340437

RESUMO

We present a deep learning based framework for real-time analysis of a differential filter based x-ray spectrometer that is common on short-pulse laser experiments. The analysis framework was trained with a large repository of synthetic data to retrieve key experimental metrics, such as slope temperature. With traditional analysis methods, these quantities would have to be extracted from data using a time-intensive and manual analysis. This framework was developed for a specific diagnostic, but may be applicable to a wide variety of diagnostics common to laser experiments and thus will be especially crucial to the development of high-repetition rate (HRR) diagnostics for HRR laser systems that are coming online.

8.
Science ; 203(4375): 45-6, 1979 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-17840509

RESUMO

Preliminary reduction of Viking bistatic radar data gives root-mean-square surface slopes in the Hellas basin on Mars of about 4 degrees on horizontal scales averaged over 10 centimeters to 100 meters. This roughness decreases slightly with position along the ground track, south to north. The dielectric constant in this area appears to be approximately 3.1, greater than the martian average. These values are characteristic of lunar maria and are similar to those found near the Viking lander site in Chryse with the use of Earth-based radar.

9.
Science ; 252(5003): 265-70, 1991 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-17769273

RESUMO

Magellan probes Venus' surface by 12.6-cm-wavelength vertical and oblique radar scattering and measures microwave thermal emission. Emissivity and root-meansquare slope maps between 330 degrees and 30 degrees E and 90 degrees N and 80 degrees S are dissimilar, although some local features are exceptions. Inferred surface emissivities typically are approximately 0.85, but vary from approximately 0.35 at Maxwell to approximately 0.95 northeast of Gula Mons and other locations. Lowest emissivities appear in topographically high areas; this relation suggests that a phase change or differences in chemical weathering occur at about 6055-kilometer radius. Initial results indicate that there are significant variations in the surface scattering function.

10.
Science ; 233(4759): 79-84, 1986 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-17812893

RESUMO

Voyager 2 radio occultation measurements of the Uranian atmosphere were obtained between 2 and 7 degrees south latitude. Initial atmospheric temperature profiles extend from pressures of 10 to 900 millibars over a height range of about 100 kilometers. Comparison of radio and infrared results yields mole fractions near the tropopause of 0.85 and 0.15 +/- 0.05 for molecular hydrogen and helium, respectively, if no other components are present; for this composition the tropopause is at about 52 kelvins and 110 millibars. Distinctive features in the signal intensity measurements for pressures above 900 millibars strongly favor model atmospheres that include a cloud deck of methane ice. Modeling of the intensity measurements for the cloud region and below indicates that the cloud base is near 1,300 millibars and 81 kelvins and yields an initial methane mole fraction of about 0.02 for the deep atmosphere. Scintillations in signal intensity indicate small-scale stucture throughout the stratosphere and upper troposphere. As judged from data obtained during occultation ingress, the ionosphere consists of a multilayer structure that includes two distinct layers at 2,000 and 3,500 kilometers above the 100-millibar level and an extended topside that may reach altitudes of 10,000 kilometers or more. Occultation measurements of the nine previously known rings at wavelengths of 3.6 and 13 centimeters show characteristic values of optical depth between about 0.8 and 8; the maxim value occurs in the outer region of the in ring, near its periapsis. Forward-scattered signals from this ring have properties that differ from those of any of Saturn's rings, and they are inconsistent with a discrete scattering object or local (three-dimensional) assemblies of orbiting objects. These signals suggest a new kdnd of planetary ring feature characterized by highly ordered cylindrical substructures of radial scale on the order of meters and azimuthal scale of kilometers or more. From radio data alone the mass of the Uranian system is GM(sys) = 5,794,547- 60 cubic kilometers per square second; from a combination of radio and optical navigation data the mass of Uranus alone is GM(u) = 5,793,939+/- 60 cubic kilometers per square second. From all available Voyager data, induding imaging radii, the mean uncompressed density of the five major satellites is 1.40+/- 0.07 grams per cubic centimeter; this value is consistent with a solar mix of material and apparently rules out a cometary origin of the satellites.

11.
Science ; 246(4936): 1466-73, 1989 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-17756001

RESUMO

The Voyager 2 encounter with the Neptune system included radio science investigations of the masses and densities of Neptune and Triton, the low-order gravitational harmonics of Neptune, the vertical structures of the atmospheres and ionospheres of Neptune and Triton, the composition of the atmosphere of Neptune, and characteristics of ring material. Demanding experimental requirements were met successfully, and study of the large store of collected data has begun. The initial search of the data revealed no detectable effects of ring material with optical depth tau [unknown] 0.01. Preliminary representative results include the following: 1.0243 x 10(26) and 2.141 x 10(22) kilograms for the masses of Neptune and Triton; 1640 and 2054 kilograms per cubic meter for their respective densities; 1355 +/- 7 kilometers, provisionally, for the radius of Triton; and J(2) = 3411 +/- 10(x 10(-6)) and J(4) = -26(+12)(-20)(x10(-6)) for Neptune's gravity field (J>(2) and J(4) are harmonic coefficients of the gravity field). The equatorial and polar radii of Neptune are 24,764 +/- 20 and 24,340 +/- 30 kllometers, respectively, at the 10(5)-pascal (1 bar) pressure level. Neptune's atmosphere was probed to a pressure level of about 5 x 10(5) pascals, and effects of a methane cloud region and probable ammonia absorption below the cloud are evident in the data. Results for the mixing ratios of helium and ammonia are still being investigated; the methane abundance below the clouds is at least 1 percent by volume. Derived temperature-pressure profiles to 1.2 x 10(5) pascals and 78 kelvins (K) show a lapse rate corresponding to "frozen" equilibrium of the para- and ortho-hydrogen states. Neptune's ionosphere exhibits an extended topside at a temperature of 950 +/- 160 K if H(+) is the dominant ion, and narrow ionization layers of the type previously seen at the other three giant planets. Triton has a dense ionosphere with a peak electron concentration of 46 x 10(9) per cubic meter at an altitude of 340 kilometers measured during occultation egress. Its topside plasma temperature is about 80 +/- 16 K if N(2)(+) is the principal ion. The tenuous neutral atmosphere of Triton produced distinct signatures in the occultation data; however, the accuracy of the measurements is limited by uncertainties in the frequency of the spacecraft reference oscillator. Preliminary values for the surface pressure of 1.6 +/- 0.3 pascals and an equivalent isothermal temperature of 48 +/- 5 K are suggested, on the assumption that molecular nitrogen dominates the atmosphere. The radio data may be showing the effects of a thermal inversion near the surface; this and other evidence imply that the Triton atmosphere is controlled by vapor-pressure equilibrium with surface ices, at a temperature of 38 K and a methane mixing ratio of about 10(-4).

12.
Science ; 266(5192): 1835-9, 1994 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-17737076

RESUMO

In the course of 71 days in lunar orbit, from 19 February to 3 May 1994, the Clementine spacecraft acquired just under two million digital images of the moon at visible and infrared wavelengths. These data are enabling the global mapping of the rock types of the lunar crust and the first detailed investigation of the geology of the lunar polar regions and the lunar far side. In addition, laser-ranging measurements provided the first view of the global topographic figure of the moon. The topography of many ancient impact basins has been measured, and a global map of the thickness of the lunar crust has been derived from the topography and gravity.

13.
Rev Sci Instrum ; 87(11): 11D703, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910487

RESUMO

X-ray and neutrons are commonly used to image inertial confinement fusion implosions, providing key diagnostic information on the fuel assembly of burning deuterium-tritium (DT) fuel. The x-ray and neutron data provided are complementary as the production of neutrons and x-rays occurs from different physical processes, but typically these two images are collected from different views with no opportunity for co-registration of the two images. Neutrons are produced where the DT fusion fuel is burning; X-rays are produced in regions corresponding to high temperatures. Processes such as mix of ablator material into the hotspot can result in increased x-ray production and decreased neutron production but can only be confidently observed if the two images are collected along the same line of sight and co-registered. To allow direct comparison of x-ray and neutron data, a combined neutron x-ray imaging system has been tested at Omega and installed at the National Ignition Facility to collect an x-ray image along the currently installed neutron imaging line of sight. This system is described, and initial results are presented along with prospects for definitive coregistration of the images.

14.
Rev Sci Instrum ; 86(4): 043503, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25933858

RESUMO

Neutron and x-ray imaging provide critical information about the geometry and hydrodynamics of inertial confinement fusion implosions. However, existing diagnostics at Omega and the National Ignition Facility (NIF) cannot produce images in both neutrons and x-rays along the same line of sight. This leads to difficulty comparing these images, which capture different parts of the plasma geometry, for the asymmetric implosions seen in present experiments. Further, even when opposing port neutron and x-ray images are available, they use different detectors and cannot provide positive information about the relative positions of the neutron and x-ray sources. A technique has been demonstrated on implosions at Omega that can capture x-ray images along the same line of sight as the neutron images. The technique is described, and data from a set of experiments are presented, along with a discussion of techniques for coregistration of the various images. It is concluded that the technique is viable and could provide valuable information if implemented on NIF in the near future.

15.
J Med Chem ; 25(7): 795-801, 1982 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-7050383

RESUMO

The effect of increased hydrophobicity at position 6 of luteinizing hormone-releasing hormone (LH-RH) has been investigated by the incorporation of a series of 15 very hydrophobic, unnatural D-amino acids at this position. The unnatural amino acids studied can be considered analogues of phenylalanine with carbocyclic aromatic side chains consisting of substituted phenyl (e.g., 2,4,6-trimethylphenyl, p-biphenyl) or polycyclic aromatic (e.g., naphthalene, anthracene) units. When enzymatic resolution (subtilisin Carlsberg) of the most hydrophobic amino acids failed, the racemic amino acids were incorporated, and the diastereomeric LH-RH analogues were resolved by preparative high-performance liquid chromatography. The analogues were synthesized by the solid-phase technique. All of the synthetic compounds were very potent LH-RH superagonists, but [6-(3-(2-naphthyl)-D-alanine)]LH-RH, [6-(3-(2-naphthyl)-D-alanine), 7-(N alpha-methylleucine)]LH-RH and [6-(3-(2,4,6-trimethylphenyl)-D-alanine)]LH-RH appear to be among the most potent LH-RH agonist analogues yet reported when tested in a rat estrus cyclicity suppression assay designed to show the paradoxical antifertility effects of these compounds [ED50 approximately 7 x 10(-8) g; twice daily in saline]. These analogues are twice as potent as [D-Trp6,ProNHEt9]LH-RH in this assay system (i.e., approximately 200 times the potency of LH-RH).


Assuntos
Hormônio Liberador de Gonadotropina/análogos & derivados , Aminoácidos/análise , Animais , Fenômenos Químicos , Química , Cromatografia Líquida de Alta Pressão , Anticoncepcionais Orais Hormonais , Estro/efeitos dos fármacos , Feminino , Hormônio Liberador de Gonadotropina/síntese química , Hormônio Liberador de Gonadotropina/farmacologia , Peptídeos/síntese química , Gravidez , Ratos , Ratos Endogâmicos , Solubilidade
16.
J Med Chem ; 29(8): 1504-11, 1986 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-3016268

RESUMO

On the basis of previous observations that both 2,3-dihydro-2,2,3,3-tetrahydroxy-1,4-naphthoquinone (oxoline, 1) and 6-chloroisonaphthazarin (2) had demonstrated antipsoriatic activity in vivo, a series of structural derivatives of 2 were prepared and examined in the Scholtz-Dumas topical psoriasis bioassay. Of these six (5, 6, 9a, 10, 11a, 11b), the most effective compound was found to be 6-chloro-1,4-diacetoxy-2,3-dimethoxynaphthalene (RS-43179, lonapalene, 11a). An extensive series of 1,2,3,4-tetraoxygenated naphthalenes (16-74) incorporating variations of the ester, ether, and aryl substituents were prepared as analogues of 11a to examine the structural requirements for activity and were screened in vivo as inhibitors of arachidonic acid induced mouse ear edema, a topical bioassay capable of detecting 5-lipoxygenase inhibitors. Net lipophilicity, hydrolytic stability, and ring substitution play significant roles in determining the observed in vivo activity. Lonapalene (11a) is currently in clinical development as a topically applied nonsteroidal antipsoriatic agent.


Assuntos
Naftalenos/uso terapêutico , Psoríase/tratamento farmacológico , 3',5'-AMP Cíclico Fosfodiesterases/antagonistas & inibidores , Administração Tópica , Animais , Araquidonato Lipoxigenases , Ácido Araquidônico , Ácidos Araquidônicos , Bioensaio , Edema/induzido quimicamente , Edema/tratamento farmacológico , Feminino , Humanos , Inibidores de Lipoxigenase , Camundongos , Naftalenos/síntese química , Neutrófilos/enzimologia , Inibidores da Ornitina Descarboxilase , Oxigênio , Relação Estrutura-Atividade , Tetra-Hidronaftalenos/síntese química , Tetra-Hidronaftalenos/uso terapêutico
17.
Placenta ; 15(8): 837-44, 1994 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-7886024

RESUMO

A common assertion in the literature is that Langhans cells in placental villi decline in number during gestation but this is a misinterpretation which may be caused by the greater growth of villous surface area compared with trophoblast volume. To test this possibility, human placentae were collected at 12-41 weeks of gestation for a cross-sectional study on the packing density of nuclei within villous trophoblast. Numbers of nuclei in the cyto- and syncytiotrophoblast were estimated using a design-based stereological device, the physical disector (parallel pairs of sections). Surface areas were estimated in order to assess the overall growth of villous arborizations. Packing densities of nuclei were calculated and expressed as numbers/1000 microns 2 of villous surface. Densities decreased during gestation and this can be explained by expansion of villous surface area and thinning of trophoblast. The biggest drop in packing density of cytotrophoblast nuclei (30 per cent) occurred between 17-21 and 22-26 weeks and this period coincided with the largest changes in villous surface area (62 per cent increase) and trophoblast thickness (30 per cent decrease). Results are consistent with the notion of an epithelial proliferative unit of constant volume and comprising about nine syncytiotrophoblast nuclei per Langhans cell.


Assuntos
Núcleo Celular/ultraestrutura , Placenta/ultraestrutura , Trofoblastos/ultraestrutura , Vilosidades Coriônicas/ultraestrutura , Epitélio/ultraestrutura , Feminino , Humanos , Gravidez
18.
Placenta ; 13(5): 501-12, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-1470609

RESUMO

A method is presented for obtaining assumption-free estimates of the number of nuclei in the trophoblast of the human placenta and for defining the size of the trophoblast proliferative unit (TPU). The method relies on the disector, a stereological device for counting arbitrary particles in 3-dimensional space using pairs of parallel sections separated by a known distance. It is applied to investigate factors which contribute to trophoblast growth from 13 weeks of gestation to term. Physical disectors were sampled systematically using adjacent 4-4.6 microns thick paraffin sections. Nuclei in the trophoblast (syncytial and cellular) were counted if they appeared in an unbiased counting frame on one section but were absent from the adjacent section. Nuclear packing densities were converted to absolute numbers of nuclei by using placental volume as the reference space. At 37-39 weeks, the average placenta contained 6.4 x 10(10) trophoblast nuclei of which 90 per cent were located within the syncytium and the remainder in the cytotrophoblast. From a knowledge of total trophoblast volume, it was found that each nucleus is associated with 970 microns3 of trophoblast and each cytotrophoblast cell with 11,000 microns3. The latter may be regarded as the volume of a TPU. From 13 weeks of gestation to term, there was a ninefold increase in nuclear number but the trophoblast volumes associated with nuclei, including the size of the TPU, remained constant. Growth of trophoblast is purely hyperplastic and occurs by recruitment of new TPUs.


Assuntos
Núcleo Celular , Trofoblastos/citologia , Divisão Celular/fisiologia , Dissecação , Feminino , Idade Gestacional , Humanos , Gravidez
19.
Infect Control Hosp Epidemiol ; 19(10): 778-81, 1998 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9801287

RESUMO

OBJECTIVES: To establish the concentration of isopropanol that exerts the same immediate and sustained effects as n-propanol 60% v/v in surgical scrubbing, and to assess the performance of the test method proposed as the European standard in parallel experiments. DESIGN: Isopropanol at concentrations of 70%, 80%, and 90% v/v was tested in comparison with n-propanol 60%, the proposed reference preparation, in the draft method proposed by the European standard. A Latin square design was used with four balanced blocks of five volunteers each in four experimental runs that were spaced by intervals of 1 week each. Volunteers were allotted randomly to one of the four blocks. Independently, the volunteers' right and left hands also were randomized into two groups for the assessment of either immediate or sustained effects. SETTING: Two laboratories supervised by two investigators, one from Vienna, Austria, and one from London, The United Kingdom. METHOD: The release of skin flora from the fingertips of clean hands was assessed before and after treatment by immediate sampling from one hand and by sampling of the other, gloved hand after 3 hours. The mean log10 reductions (RF) of bacterial release achieved by rubbing the alcoholic preparations for 3 minutes onto the hands were established. RESULTS: For both experiments, the immediate effects of isopropanol 70% (RF, 2.0 and 2.1, respectively) were significantly smaller than those of the reference n-propanol 60% (RF, 2.4 and 2.6, respectively). This also was found with the sustained effects (RF, 0.7 and 1.1 vs 1.0 and 1.6, respectively). At 90%, isopropanol equalled the immediate effect of n-propanol 60%, whereas at 80% it proved slightly (although not significantly) less active. There were no significant differences in the results of both investigators. The sustained effects of isopropanol 80% and 90% were both larger than the reference in Vienna but were found smaller by the London investigator; none of the differences were significant. Mean RFs were significantly different between Vienna and London with n-propanol 60% and isopropanol 70%, but not with isopropanol at 80% or 90%. CONCLUSIONS: At 90%, isopropanol is as effective as n-propanol 60%, which was proposed by the European Committee for Standardization as a reference in testing products for surgical hand disinfection. It could, therefore, serve as an alternative if the proposed agent is undesirable for any reason. In parallel experiments by two investigators, the proposed test method proved well workable; the results were very similar and the conclusions identical.


Assuntos
1-Propanol/administração & dosagem , 2-Propanol/administração & dosagem , Anti-Infecciosos Locais/administração & dosagem , Desinfetantes/administração & dosagem , Desinfecção das Mãos/normas , Adulto , Áustria , Europa (Continente) , Feminino , Humanos , Laboratórios/normas , Londres , Masculino , Padrões de Referência , Valores de Referência
20.
J Med Microbiol ; 26(1): 61-5, 1988 May.
Artigo em Inglês | MEDLINE | ID: mdl-3373515

RESUMO

Men with indwelling catheters and men and women with suprapubic catheters were studied in their homes. Urine and blood were cultured and body temperature recorded after every catheter change. Nearly all patients had infected urine after 4 weeks of catheterisation, and all had bacteriuria after longer periods, usually with a mixture of organisms. Culture on selective media revealed a wider range of organisms than was detected on routine C.L.E.D. and blood agar with antibiotic sensitivity disks, but routine culture gave adequate information for clinical purposes. Bacteraemia was demonstrated after 20 of 197 changes of urethral catheter and after one of 19 changes of suprapubic catheter; but no patient had pyrexia or other symptoms. However, two had rigors on other occasions. When assessing "risk factors" for blood-stream infection in catheterised patients, it is important to record the total incidence of bacteraemia, asymptomatic as well as symptomatic.


Assuntos
Bacteriúria/etiologia , Cateteres de Demora/efeitos adversos , Sepse/etiologia , Cateterismo Urinário/efeitos adversos , Bactérias/isolamento & purificação , Bacteriúria/epidemiologia , Bacteriúria/microbiologia , Meios de Cultura , Feminino , Serviços de Assistência Domiciliar , Humanos , Masculino , Testes de Sensibilidade Microbiana , Fatores de Risco , Sepse/epidemiologia , Sepse/microbiologia , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA