Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Hand Surg Eur Vol ; 48(8): 792-797, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36927212

RESUMO

Assessment of carpal alignment traditionally uses carpal bone axes measured on lateral radiographs. In this study, three-dimensional axes were defined for carpal bones using segmentation and numerical modelling of CT data of 121 neutrally positioned, asymptomatic wrists. The geometric axis was used for radius, scaphoid and capitate, whereas the axis based on a line perpendicular to the articular surface was used for the other carpal bones. Normal values of radiocarpal angles in the radial coordinate and the reliability of the computer-aided analysis are reported. The mean sagittal radiocarpal angles (positive in palmar direction) were as follows: scaphoid 58° (SD 10°), lunate 0° (SD 11°), triquetrum 12° (SD 8°), trapezium 17° (SD 8°), trapezoid -10° (SD 7°), capitate -17° (SD 9°) and hamate 2° (SD 7°). The mean coronal radiocarpal angles (positive in ulnar direction) were -42° (SD 9°), -20° (SD 4°), -49° (SD 4°), -32° (SD 6°), -16° (SD 5°), 2° (SD 7°) and 8° (SD 6°), respectively. The intra-observer reliability of the measurements was excellent (mean intraclass correlations coefficient 0.98). This study provides guidelines on how to measure and quantify carpal alignment three-dimensionally, and a database for the normal values. Together, these may be useful when analysing various wrist pathologies and kinematics of the wrist.


Assuntos
Ossos do Carpo , Osso Escafoide , Humanos , Valores de Referência , Reprodutibilidade dos Testes , Ossos do Carpo/diagnóstico por imagem , Articulação do Punho/diagnóstico por imagem , Fenômenos Biomecânicos , Tomografia Computadorizada por Raios X , Computadores
2.
J Hand Surg Eur Vol ; 46(10): 1064-1071, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34407693

RESUMO

The three-dimensional carpal alignment was measured in the neutral wrist position in 121 asymptomatic volunteers using computer-based cone-beam CT analysis. Normal values and the reliability of the automated analysis are reported. An analysis software based on segmentation of CT images and mathematical modelling was used to determine several axis variants based on different landmarks and to calculate the intercarpal angles automatically. Twenty wrists were imaged twice to determine intra-observer reliability. Mean values using the preferred axis variants were: scapholunate angle 57° (SD 9°), radiolunate angle 2° (SD 10°), lunocapitate angle -14° (SD 9°). Using alternate axis variants notably changed the angles produced. The intra-observer reliability of the analysis was excellent (mean intraclass correlation coefficient 0.97, SD 0.03). Computer-based CT analysis enables highly reproducible and automated assessment of carpal alignment. This study provides a reference database for measurement techniques and normal carpal angle values in three-dimensional imaging.


Assuntos
Ossos do Carpo , Ossos do Carpo/diagnóstico por imagem , Computadores , Humanos , Imageamento Tridimensional , Valores de Referência , Reprodutibilidade dos Testes , Articulação do Punho/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA