Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Nephrol ; 31(1): 137-145, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28012100

RESUMO

BACKGROUND AND AIMS: Encapsulating peritoneal sclerosis (EPS) is an uncommon but severe complication of peritoneal dialysis (PD). A reliable screening tool to identify patients at risk of developing or not EPS is currently not available. We aimed to evaluate whether the reduction in dialysate sodium concentration (sodium sieving) at 60 min (ΔDNa60), during a peritoneal equilibration test with 3.86% glucose concentration (3.86%-PET) was able to early rule out patients who will not develop EPS. METHODS: Prospective controlled longitudinal (20-year) cohort study. All eligible incident PD patients attending the hospital underwent a 3.86%-PET during the first 3 months following start of PD and then once a year. The dip in ΔDNa60 and other factors were correlated with eventual EPS onset. RESULTS: Of 161 incident PD patients, with a median PD duration of 37.8 (24.7-58.3) months and 64.1 (34.5-108.3) months of follow-up, 13 patients (8%) developed EPS at a median PD duration of 72.7 (56.6-109.4) months and 105.0 (76.4-143.2) months of follow-up. ΔDNa60 demonstrated the best sensitivity and specificity values, estimated by conventional receiver operating characteristic (ROC) curve analysis with an area under the curve (AUC) of 0.90, 0.83 and 0.85 at 1, 2 and 3 years before the onset of EPS, respectively. Multifactorial analysis showed that the most useful factors for predicting EPS were age at start of PD, duration of PD, small solutes transport (D/PCreat) and ΔDNa60; the AUC at 1, 2 and 3 years before the onset of EPS was, respectively, 0.97, 0.96 and 0.94, the positive predictive value being 0.48, 0.57 and 0.42, and the negative predictive value 1.0, 1.0 and 1.0. CONCLUSIONS: It is possible to predict the occurrence and, better, the non-occurrence of EPS using simple parameters such as age at PD start, duration of PD, and parameters obtained by 3.86%-PET such as D/PCreat and ΔDNa60.


Assuntos
Soluções para Diálise/metabolismo , Diálise Peritoneal/efeitos adversos , Fibrose Peritoneal/epidemiologia , Peritônio/metabolismo , Sódio/metabolismo , Adulto , Fatores Etários , Idoso , Área Sob a Curva , Transporte Biológico , Biomarcadores/metabolismo , Soluções para Diálise/administração & dosagem , Soluções para Diálise/efeitos adversos , Feminino , Humanos , Incidência , Itália/epidemiologia , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Fibrose Peritoneal/diagnóstico , Fibrose Peritoneal/metabolismo , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
2.
G Ital Nefrol ; 34(Nov-Dec)2017 Dec 05.
Artigo em Italiano | MEDLINE | ID: mdl-29207228

RESUMO

Among dialysis patients, 40% of deaths are due to cardiovascular causes, and 60% of cardiac deaths are due to an arrhythmia. The purpose of this survey, carried out with the organizational support of the Lombard Section of the Italian Society of Nephrology, is to evaluate the frequency and mode of use of non-invasive instruments for the diagnosis of cardiac arrhythmias in the dialysis centers of Lombardy. Information on the prevalence and type of cardiac devices at December 1, 2016 in this population was also required. Data from 18 centers were collected for a total of 3395 patients in replacement renal therapy, including 2907 (85.6%) in hemodialysis and 488 (14.4%) in peritoneal dialysis. All centers use the 12-lead ECG in case of evocative symptoms of an arrhythmic event and 2/3 perform the exam with programmed cadence (usually once a year). Twenty four-hour ECG Holter is not used as a routine diagnostic tool. The proportion of cardiac devices is relatively high, compared to literature data: n=259, equal to 7.6% of the population. Pace-Maker patients are 166 (4.9%), those with intracardiac defibrillator 52 (1.5%), those with resynchronization therapy 18 (0.5%) and those with resynchronization therapy and intracardiac defibrillator 23 (0.7%). The survey provides interesting information and can be an important starting point for trying to optimize clinical practice and collaboration between nephrologists and cardiologists in front of a major problem like that of arrhythmic disease in patients on renal replacement therapy.


Assuntos
Arritmias Cardíacas/diagnóstico , Eletrocardiografia , Falência Renal Crônica/complicações , Terapia de Substituição Renal , Arritmias Cardíacas/complicações , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/terapia , Terapia de Ressincronização Cardíaca , Cardiologia , Desfibriladores Implantáveis , Gerenciamento Clínico , Cardioversão Elétrica , Eletrocardiografia/métodos , Eletrocardiografia/estatística & dados numéricos , Eletrocardiografia Ambulatorial/estatística & dados numéricos , Pesquisas sobre Atenção à Saúde , Parada Cardíaca/etiologia , Parada Cardíaca/prevenção & controle , Humanos , Itália/epidemiologia , Falência Renal Crônica/terapia , Nefrologia , Marca-Passo Artificial , Equipe de Assistência ao Paciente , Terapia de Substituição Renal/efeitos adversos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle
3.
Biol Blood Marrow Transplant ; 13(9): 1031-40, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17697965

RESUMO

The majority of unrelated donor (UD) hematopoietic stem cell (HSC) transplants are performed across HLA-DP mismatches, which, if involving disparity in a host-versus-graft (HVG) direction for an alloreactive T cell epitope (TCE), have been shown by our group to be associated with poor clinical outcome in 2 cohorts of patients transplanted for hematopoietic malignancies and beta-thalassemia, respectively. Using site-directed mutagenesis of DPB1*0901, we show here that the TCE is abrogated by the presence of amino acids LFQG in positions 8-11 of the DP beta-chain. Based on this and on alloreactive T cell responsiveness, we have determined the presence or absence of the TCE for 72 DPB1 alleles reported in the ethnic groups representative of the worldwide UD registries, and predict that 67%-87% (mean 77%) of UD recipient pairs will not present a DPB1 TCE disparity in the HVG direction. We developed and validated in 112 healthy Italian blood donors an innovative approach of DPB1 epitope-specific typing (EST), based on 2 PCR reactions. Our data show that DPB1 TCE disparities may hamper the clinical success of a considerable number of transplants when DPB1 matching is not included into the donor selection criteria, and that a donor without DPB1 TCE disparities in the HVG direction can be found for the majority of patients. Moreover, the study describes the first protocol of targeted epitope-specific DPB1 donor-recipient matching for unrelated HSC transplantation. This protocol will facilitate large-scale retrospective clinical studies warranted to more precisely determine the clinical relevance of DPB1 TCE disparities in different transplant conditions.


Assuntos
Epitopos de Linfócito T/imunologia , Antígenos HLA-DP/análise , Transplante de Células-Tronco Hematopoéticas/métodos , Teste de Histocompatibilidade/métodos , Sequência de Aminoácidos , Etnicidade , Frequência do Gene , Antígenos HLA-DP/genética , Antígenos HLA-DP/imunologia , Cadeias beta de HLA-DP , Neoplasias Hematológicas/terapia , Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Transplante de Células-Tronco Hematopoéticas/etnologia , Teste de Histocompatibilidade/normas , Reação Hospedeiro-Enxerto/genética , Humanos , Itália , Mutagênese Sítio-Dirigida , Doadores de Tecidos , Transplante Homólogo , Talassemia beta/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA