Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Pflugers Arch ; 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38937370

RESUMO

Autonomic control of heart rate is well known in adult subjects, but limited data are available on the development of the heart rate control during childhood and adolescence. Continuous 12-lead electrocardiograms were recorded in 1045 healthy children and adolescents (550 females) aged 4 to 19 years during postural manoeuvres involving repeated 10-min supine, unsupported sitting, and unsupported standing positions. In each position, heart rate was measured, and heart rate variability indices were evaluated (SDNN, RMSSD, and high (HF) and low (LF) frequency components were obtained). Quasi-normalized HF frequency components were defined as qnHF = HF/(HF + LF). These measurements were, among others, related to age using linear regressions. In supine position, heart rate decreases per year of age were significant in both sexes but lower in females than in males. In standing position, these decreases per year of age were substantially lowered. RMSSD and qnHF indices were independent of age in supine position but significantly decreased with age in sitting and standing positions. Correspondingly, LF/HF proportions showed steep increases with age in sitting and standing positions but not in the supine position. The study suggests that baseline supine parasympathetic influence shows little developmental changes during childhood and adolescence but that in young children, sympathetic branch is less responsive to vagal influence. While vagal influences modulate cardiac periods in young and older children equally, they are less able to suppress the sympathetic influence in younger children.

2.
BMC Pediatr ; 20(1): 558, 2020 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-33317470

RESUMO

BACKGROUND: Bazett formula is frequently used in paediatric screening for the long QT syndrome (LQTS) and proposals exist that using standing rather than supine electrocardiograms (ECG) improves the sensitivity of LQTS diagnosis. Nevertheless, compared to adults, children have higher heart rates (especially during postural provocations) and Bazett correction is also known to lead to artificially prolonged QTc values at increased heart rates. This study assessed the incidence of erroneously increased QTc values in normal children without QT abnormalities. METHODS: Continuous 12-lead ECGs were recorded in 332 healthy children (166 girls) aged 10.7 ± 2.6 years while they performed postural manoeuvring consisting of episodes (in the following order) of supine, sitting, standing, supine, standing, sitting, and supine positions, each lasting 10 min. Detailed analyses of QT/RR profiles confirmed the absence of prolonged individually corrected QTc interval in each child. Heart rate and QT intervals were measured in 10-s ECG segments and in each segment, QTc intervals were obtained using Bazett, Fridericia, and Framingham formulas. In each child, the heart rates and QTc values obtained during supine, sitting and standing positions were averaged. QTc durations by the three formulas were classified to < 440 ms, 440-460 ms, 460-480 ms, and > 480 ms. RESULTS: At supine position, averaged heart rate was 77.5 ± 10.5 beat per minute (bpm) and Bazett, Fridericia and Framingham QTc intervals were 425.3 ± 15.8, 407.8 ± 13.9, and 408.2 ± 13.1 ms, respectively. At sitting and standing, averaged heart rate increased to 90.9 ± 10.1 and 100.9 ± 10.5 bpm, respectively. While Fridericia and Framingham formulas showed only minimal QTc changes, Bazett correction led to QTc increases to 435 ± 15.1 and 444.9 ± 15.9 ms at sitting and standing, respectively. At sitting, Bazett correction identified 51, 4, and 0 children as having the QTc intervals 440-460, 460-480, and > 480 ms, respectively. At sitting, these numbers increased to 118, 11, and 1, while on standing these numbers were 151, 45, and 5, respectively. Irrespective of the postural position, Fridericia and Framingham formulas identified only a small number (< 7) of children with QT interval between 440 and 460 ms and no children with longer QTc. CONCLUSION: During screening for LQTS in children, the use of Bazett formula leads to a high number of false positive cases especially if the heart rates are increased (e.g. by postural manoeuvring). The use of Fridericia formula can be recommended to replace the Bazett correction not only for adult but also for paediatric ECGs.


Assuntos
Síndrome do QT Longo , Adolescente , Adulto , Criança , Eletrocardiografia , Família , Feminino , Frequência Cardíaca , Humanos , Síndrome do QT Longo/diagnóstico
3.
J Electrocardiol ; 51(6S): S6-S11, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30122457

RESUMO

INTRODUCTION: Interpretation of the 12­lead Electrocardiogram (ECG) is normally assisted with an automated diagnosis (AD), which can facilitate an 'automation bias' where interpreters can be anchored. In this paper, we studied, 1) the effect of an incorrect AD on interpretation accuracy and interpreter confidence (a proxy for uncertainty), and 2) whether confidence and other interpreter features can predict interpretation accuracy using machine learning. METHODS: This study analysed 9000 ECG interpretations from cardiology and non-cardiology fellows (CFs and non-CFs). One third of the ECGs involved no ADs, one third with ADs (half as incorrect) and one third had multiple ADs. Interpretations were scored and interpreter confidence was recorded for each interpretation and subsequently standardised using sigma scaling. Spearman coefficients were used for correlation analysis and C5.0 decision trees were used for predicting interpretation accuracy using basic interpreter features such as confidence, age, experience and designation. RESULTS: Interpretation accuracies achieved by CFs and non-CFs dropped by 43.20% and 58.95% respectively when an incorrect AD was presented (p < 0.001). Overall correlation between scaled confidence and interpretation accuracy was higher amongst CFs. However, correlation between confidence and interpretation accuracy decreased for both groups when an incorrect AD was presented. We found that an incorrect AD disturbs the reliability of interpreter confidence in predicting accuracy. An incorrect AD has a greater effect on the confidence of non-CFs (although this is not statistically significant it is close to the threshold, p = 0.065). The best C5.0 decision tree achieved an accuracy rate of 64.67% (p < 0.001), however this is only 6.56% greater than the no-information-rate. CONCLUSION: Incorrect ADs reduce the interpreter's diagnostic accuracy indicating an automation bias. Non-CFs tend to agree more with the ADs in comparison to CFs, hence less expert physicians are more effected by automation bias. Incorrect ADs reduce the interpreter's confidence and also reduces the predictive power of confidence for predicting accuracy (even more so for non-CFs). Whilst a statistically significant model was developed, it is difficult to predict interpretation accuracy using machine learning on basic features such as interpreter confidence, age, reader experience and designation.


Assuntos
Arritmias Cardíacas/diagnóstico , Automação , Competência Clínica , Erros de Diagnóstico/estatística & dados numéricos , Eletrocardiografia , Viés , Árvores de Decisões , Humanos , Variações Dependentes do Observador , Incerteza
4.
J Electrocardiol ; 48(6): 988-94, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26381796

RESUMO

BACKGROUND: The electrocardiogram (ECG) is the most commonly used diagnostic procedure for assessing the cardiovascular system. The aim of this study was to compare ECG diagnostic skill among fellows of cardiology and of other internal medicine specialties (non-cardiology fellows). METHODS: A total of 2900 ECG interpretations were collected. A set of 100 clinical 12-lead ECG tracings were selected and classified into 12 diagnostic categories. The ECGs were evaluated by 15 cardiology fellows and of 14 non-cardiology fellows. Diagnostic interpretations were classified as (1) correct, (2) almost correct, (3) incorrect, and (4) dangerously incorrect. Multivariate logistic regression was used to assess confounding factors and to determine the odds ratios for the months of experience, age, sex, and the distinction between cardiology and non-cardiology fellows. RESULTS: The mean rate of correct diagnoses by cardiology vs. non-cardiology fellows was 48.9±8.9% vs. 35.9±8.0% (p=0.001; 70.1% vs. 55.0% for the aggregate of 'correct' and 'almost correct' diagnoses). There were 10.2±5.6% of interpretations classified as 'dangerously incorrect' by cardiology fellows vs. 16.3±5.0% by non-cardiology fellows (p=0.008). The cardiology fellows achieved statistically significantly greater diagnostic accuracy in 7 out of the 12 diagnostic classes. In multivariable logistic regression, the distinction between cardiology and non-cardiology fellows was the only independent statistically significant (p<0.001) predictor of whether the reader is likely correct or incorrect. Being a non-cardiology fellow reduced the probability of correct classification by 42% (odds ratio [95% confidence interval]: 0.58 [0.50; 0.68]). CONCLUSIONS: Although cardiology fellows out-performed the others, skills in ECG interpretation were found not adequately proficient. A comprehensive approach to ECG education is necessary. Further studies are needed to evaluate proper methods of training, testing, and continuous medical education in ECG interpretation.


Assuntos
Arritmias Cardíacas/diagnóstico , Competência Clínica/estatística & dados numéricos , Erros de Diagnóstico/estatística & dados numéricos , Eletrocardiografia/estatística & dados numéricos , Médicos/estatística & dados numéricos , Adulto , Europa (Continente) , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
J Electrocardiol ; 47(6): 863-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25175174

RESUMO

BACKGROUND: Repolarization processes in female and male are different. This study provided pilot data on automatic measurements of QT intervals in heart transplant (HT) recipients stratified according to the sex of the recipient and the donor. METHODS AND RESULTS: The following groups were analyzed: Group A-20 males with male heart, group B-14 females with male heart, group C-13 females with female heart, group D-11 males with female heart, group E-20 healthy males, and group F-20 healthy females. Twelve-lead electrocardiograms were digitally captured during autonomic provocative test of five postural 8-minute stages-supine, unsupported sitting, supine, unsupported standing, and supine. Fridericia formula was used for heart rate correction together with a generic correction for QT/RR hysteresis. Neither female nor male HT recipients exhibit any differences in QTc interval duration related to the sex of the donor. There was, however, a trend towards longer QTc intervals in female HT recipients compared to male HT recipients irrespective of the sex of the donor. The QTc differences between healthy control females and males were highly statistically significant proving the assay sensitivity of the study. CONCLUSION: The available pilot data suggest that in HT patients, the sex of the donor has little influence on the QTc interval of the transplanted heart.


Assuntos
Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/cirurgia , Frequência Cardíaca , Transplante de Coração/estatística & dados numéricos , Doadores de Tecidos/estatística & dados numéricos , Transplantados/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , República Tcheca/epidemiologia , Eletrocardiografia Ambulatorial/estatística & dados numéricos , Feminino , Insuficiência Cardíaca/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Caracteres Sexuais , Distribuição por Sexo
6.
J Clin Med ; 13(10)2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38792438

RESUMO

Background/Objective: The relationship between heart rate and heart rate variability (HRV) indices has been repeatedly studied in adults but limited data are available on the relationship in paediatric populations. Methods: Continuous 12-lead electrocardiograms were recorded in 1016 healthy children and adolescents (534 females) aged 4 to 19 years during postural manoeuvres with rapid changes between 10-min positions of supine → sitting → standing → supine → standing → sitting → supine. In each position, the averaged RR interval was measured together with four HRV indices, namely the SDNN, RMSSD, quasi-normalised high-frequency components (qnHF), and the proportions of low- and high-frequency components (LF/HF). In each subject, the slope of the linear regression between the repeated HRV measurements and the corresponding RR interval averages was calculated. Results: The intra-subject regression slopes, including their confidence intervals, were related to the age and sex of the subjects. The SDNN/RR, RMSSD/RR, and qnHF/RR slopes were significantly steeper (p < 0.001) and the (LF/HF)/RR slopes were significantly shallower (p < 0.001) in younger children compared to older children and adolescents. Conclusions: The study suggests that sympathetic and vagal influences on heart rate are present in both younger and older children. With advancing age, the sympatho-vagal balance gradually develops and allows the vagal control to suppress the sympathetic drive towards higher heart rates seen in younger age children.

7.
Sci Rep ; 14(1): 11938, 2024 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-38789480

RESUMO

Heart rate is under constant autonomic influence but the development of the influence in children is not fully understood. Continuous electrocardiograms were obtained in 1045 healthy school-age children (550 females) during postural provocations with body position changes between supine, sitting, standing, supine, standing, sitting and supine (in this order), 10 min in each position with position changes within 20 s. Heart rate was measured in each position and speed of heart rate changes between positions were assessed by regressions of rates versus timing of individual cardiac cycles. Supine heart rate was gradually decreasing with age: 82.32 ± 9.92, 74.33 ± 9.79, 67.43 ± 9.45 beats per minute (bpm) in tertile age groups < 11, 11-15, > 15 years, respectively (p < 0.0001), with no significant sex difference. Averaged speed of heart rate changes differed little between sexes and age groups but was significantly faster during rate deceleration than acceleration (e.g., supine ↔ standing: 2.99 ± 1.02 vs. 2.57 ± 0.68 bpm/s, p < 0.0001). The study suggests that in children, vagal heart rate control does not noticeably change between ages of approximately 6-19 years. The gradual resting heart rate decrease during childhood and adolescence is likely caused by lowering of cardiac sympathetic influence from sympathetic overdrive in small children to adult-like sympatho-vagal balance in older adolescents.


Assuntos
Eletrocardiografia , Frequência Cardíaca , Postura , Humanos , Frequência Cardíaca/fisiologia , Feminino , Criança , Masculino , Adolescente , Postura/fisiologia , Sistema Nervoso Autônomo/fisiologia , Decúbito Dorsal/fisiologia , Nervo Vago/fisiologia
8.
J Electrocardiol ; 45(6): 752-7, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22889675

RESUMO

BACKGROUND: Antiarrhythmic properties of statins were suggested as a part of their pleiotropic effects. The aim of the present study was to evaluate the effects of atorvastatin on myocardial repolarization as manifested on surface electrocardiograms (ECGs) in healthy subjects. METHODS AND RESULTS: Forty young healthy volunteers (20 men, 20 women) underwent a single-dose double-blind 3-way crossover study of 20 and 80 mg of atorvastatin and placebo. Long-term 13-hour 12-lead ECGs were obtained in each subject and each study period starting 15 minutes before drug administration. Each study period contained 18 time-points of 5-minute durations when the subjects were in resting supine positions. Digital ECG recordings were analyzed automatically, and the results were completed blindly before statistical analyses. Dynamic parameters of myocardial repolarization and T-wave morphology descriptors were evaluated. Although some trends were observed, no significant drug-related changes in any of investigated ECG repolarization descriptors were found. CONCLUSION: In comparison with placebo, single doses of atorvastatin had no effect on repolarization heterogeneity in healthy subjects. The observation confirms safe profile of the drug with limited proarrhythmic potential.


Assuntos
Eletrocardiografia/efeitos dos fármacos , Frequência Cardíaca/efeitos dos fármacos , Ácidos Heptanoicos/administração & dosagem , Pirróis/administração & dosagem , Adulto , Atorvastatina , Relação Dose-Resposta a Droga , Método Duplo-Cego , Feminino , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/administração & dosagem , Masculino , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Método Simples-Cego
9.
J Electrocardiol ; 45(6): 746-51, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22727609

RESUMO

BACKGROUND: Classic symptoms of long QT syndrome (LQTS) include prolongation of QT interval on electrocardiograph, syncope, and cardiac arrest due to a distinctive form of polymorphic ventricular tachycardia, known as Torsade de Pointes. We assessed occurrence of LQTS signs in individuals from 30 Czech families with mutations in KCNQ1 and KCNH2 genes. METHODS AND RESULTS: One hundred five individuals from 30 Czech families with LQTS were genotyped for KCNQ1 and KCNH2. The occurrence of typical LQTS signs (pathologic prolongation of QT interval; syncope; cardiac arrest; Torsade de Pointes) was clinically assessed by exercise test with QT interval analysis. Family history of sudden cardiac death was taken. Statistical analysis was performed to determine correlation of clinical results and mutation status. KCNQ1 gene mutations were found in 23 families, and KCNH2 gene mutations in eight families. Only 46 (70%) of the 66 mutation carriers had at least two of the typical LQTS signs. The others were minimally or asymptomatic. From 39 noncarrier individuals, only 1 fulfilled the clinical criteria of LQTS diagnosis, another 4 had an intermediate probability of diagnosis. The exercise test had 92% sensitivity and 93% specificity for LQTS diagnosis. CONCLUSIONS: Incidence of classical signs of LQTS was not high in Czech carriers of KCNQ1 and KCNH2 mutations. Therefore, proper diagnosis relies on detection of symptoms at presentation. The exercise test may be beneficial owing to its high sensitivity and specificity for LQTS diagnosis.


Assuntos
Eletrocardiografia/estatística & dados numéricos , Canais de Potássio Éter-A-Go-Go/genética , Teste de Esforço/estatística & dados numéricos , Síndrome do QT Longo/diagnóstico , Síndrome do QT Longo/genética , RNA Longo não Codificante/genética , Adulto , República Tcheca/epidemiologia , Canal de Potássio ERG1 , Feminino , Predisposição Genética para Doença/epidemiologia , Predisposição Genética para Doença/genética , Humanos , Síndrome do QT Longo/epidemiologia , Masculino , Mutação/genética , Polimorfismo de Nucleotídeo Único/genética , Prevalência , Reprodutibilidade dos Testes , Medição de Risco , Sensibilidade e Especificidade
10.
Front Physiol ; 13: 863873, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35431991

RESUMO

Increases in beat-to-beat variability of electrocardiographic QT interval duration have repeatedly been associated with increased risk of cardiovascular events and complications. The measurements of QT variability are frequently normalized for the underlying RR interval variability. Such normalization supports the concept of the so-called immediate RR effect which relates each QT interval to the preceding RR interval. The validity of this concept was investigated in the present study together with the analysis of the influence of electrocardiographic morphological stability on QT variability measurements. The analyses involved QT and RR measurements in 6,114,562 individual beats of 642,708 separate 10-s ECG samples recorded in 523 healthy volunteers (259 females). Only beats with high morphology correlation (r > 0.99) with representative waveforms of the 10-s ECG samples were analyzed, assuring that only good quality recordings were included. In addition to these high correlations, SDs of the ECG signal difference between representative waveforms and individual beats expressed morphological instability and ECG noise. In the intra-subject analyses of both individual beats and of 10-s averages, QT interval variability was substantially more strongly related to the ECG noise than to the underlying RR variability. In approximately one-third of the analyzed ECG beats, the prolongation or shortening of the preceding RR interval was followed by the opposite change of the QT interval. In linear regression analyses, underlying RR variability within each 10-s ECG sample explained only 5.7 and 11.1% of QT interval variability in females and males, respectively. On the contrary, the underlying ECG noise contents of the 10-s samples explained 56.5 and 60.1% of the QT interval variability in females and males, respectively. The study concludes that the concept of stable and uniform immediate RR interval effect on the duration of subsequent QT interval duration is highly questionable. Even if only stable beat-to-beat measurements of QT interval are used, the QT interval variability is still substantially influenced by morphological variability and noise pollution of the source ECG recordings. Even when good quality recordings are used, noise contents of the electrocardiograms should be objectively examined in future studies of QT interval variability.

11.
Front Physiol ; 13: 939633, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36457310

RESUMO

Three-dimensional angle between the QRS complex and T wave vectors is a known powerful cardiovascular risk predictor. Nevertheless, several physiological properties of the angle are unknown or poorly understood. These include, among others, intra-subject profiles and stability of the angle relationship to heart rate, characteristics of angle/heart-rate hysteresis, and the changes of these characteristics with different modes of QRS-T angle calculation. These characteristics were investigated in long-term 12-lead Holter recordings of 523 healthy volunteers (259 females). Three different algorithmic methods for the angle computation were based on maximal vector magnitude of QRS and T wave loops, areas under the QRS complex and T wave curvatures in orthogonal leads, and weighted integration of all QRS and T wave vectors moving around the respective 3-dimensional loops. These methods were applied to orthogonal leads derived either by a uniform conversion matrix or by singular value decomposition (SVD) of the original 12-lead ECG, giving 6 possible ways of expressing the angle. Heart rate hysteresis was assessed using the exponential decay models. All these methods were used to measure the angle in 659,313 representative waveforms of individual 10-s ECG samples and in 7,350,733 individual beats contained in the same 10-s samples. With all measurement methods, the measured angles fitted second-degree polynomial regressions to the underlying heart rate. Independent of the measurement method, the angles were found significantly narrower in females (p < 0.00001) with the differences to males between 10o and 20o, suggesting that in future risk-assessment studies, different angle dichotomies are needed for both sexes. The integrative method combined with SVD leads showed the highest intra-subject reproducibility (p < 0.00001). No reproducible delay between heart rate changes and QRS-T angle changes was found. This was interpreted as a suggestion that the measurement of QRS-T angle might offer direct assessment of cardiac autonomic responsiveness at the ventricular level.

12.
Sci Rep ; 11(1): 14269, 2021 07 12.
Artigo em Inglês | MEDLINE | ID: mdl-34253795

RESUMO

Monitoring of QTc interval is mandated in different clinical conditions. Nevertheless, intra-subject variability of QTc intervals reduces the clinical utility of QTc monitoring strategies. Since this variability is partly related to QT heart rate correction, 10 different heart rate corrections (Bazett, Fridericia, Dmitrienko, Framingham, Schlamowitz, Hodges, Ashman, Rautaharju, Sarma, and Rabkin) were applied to 452,440 ECG measurements made in 539 healthy volunteers (259 females, mean age 33.3 ± 8.4 years). For each correction formula, the short term (5-min time-points) and long-term (day-time hours) variability of rate corrected QT values (QTc) was investigated together with the comparisons of the QTc values with individually corrected QTcI values obtained by subject-specific modelling of the QT/RR relationship and hysteresis. The results showed that (a) both in terms of short-term and long-term QTc variability, Bazett correction led to QTc values that were more variable than the results of other corrections (p < 0.00001 for all), (b) the QTc variability by Fridericia and Framingham corrections were not systematically different from each other but were lower than the results of other corrections (p-value between 0.033 and < 0.00001), and (c) on average, Bazett QTc values departed from QTcI intervals more than the QTc values of other corrections. The study concludes that (a) previous suggestions that Bazett correction should no longer be used in clinical practice are fully justified, (b) replacing Bazett correction with Fridericia and/or Framingham corrections would improve clinical QTc monitoring, (c) heart rate stability is needed for valid QTc assessment, and (d) development of further QTc corrections for day-to-day use is not warranted.


Assuntos
Cardiologia/normas , Eletrocardiografia/métodos , Frequência Cardíaca/fisiologia , Síndrome do QT Longo/diagnóstico , Adulto , Algoritmos , Cardiologia/métodos , Feminino , Humanos , Síndrome do QT Longo/fisiopatologia , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador
13.
Front Physiol ; 12: 814542, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35197861

RESUMO

While it is now well-understood that the extent of QT interval changes due to underlying heart rate differences (i.e., the QT/RR adaptation) needs to be distinguished from the speed with which the QT interval reacts to heart rate changes (i.e., the so-called QT/RR hysteresis), gaps still exist in the physiologic understanding of QT/RR hysteresis processes. This study was designed to address the questions of whether the speed of QT adaptation to heart rate changes is driven by time or by number of cardiac cycles; whether QT interval adaptation speed is the same when heart rate accelerates and decelerates; and whether the characteristics of QT/RR hysteresis are related to age and sex. The study evaluated 897,570 measurements of QT intervals together with their 5-min histories of preceding RR intervals, all recorded in 751 healthy volunteers (336 females) aged 34.3 ± 9.5 years. Three different QT/RR adaptation models were combined with exponential decay models that distinguished time-based and interval-based QT/RR hysteresis. In each subject and for each modelling combination, a best-fit combination of modelling parameters was obtained by seeking minimal regression residuals. The results showed that the response of QT/RR hysteresis appears to be driven by absolute time rather than by the number of cardiac cycles. The speed of QT/RR hysteresis was found decreasing with increasing age whilst the duration of individually rate corrected QTc interval was found increasing with increasing age. Contrary to the longer QTc intervals, QT/RR hysteresis speed was faster in females. QT/RR hysteresis differences between heart rate acceleration and deceleration were not found to be physiologically systematic (i.e., they differed among different healthy subjects), but on average, QT/RR hysteresis speed was found slower after heart rate acceleration than after rate deceleration.

14.
Sci Rep ; 11(1): 4289, 2021 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-33619292

RESUMO

The normal physiologic range of QRS complex duration spans between 80 and 125 ms with known differences between females and males which cannot be explained by the anatomical variations of heart sizes. To investigate the reasons for the sex differences as well as for the wide range of normal values, a technology is proposed based on the singular value decomposition and on the separation of different orthogonal components of the QRS complex. This allows classification of the proportions of different components representing the 3-dimensional representation of the electrocardiographic signal as well as classification of components that go beyond the 3-dimensional representation and that correspond to the degree of intricate convolutions of the depolarisation sequence. The technology was applied to 382,019 individual 10-s ECG samples recorded in 639 healthy subjects (311 females and 328 males) aged 33.8 ± 9.4 years. The analyses showed that QRS duration was mainly influenced by the proportions of the first two orthogonal components of the QRS complex. The first component demonstrated statistically significantly larger proportion of the total QRS power (expressed by the absolute area of the complex in all independent ECG leads) in females than in males (64.2 ± 11.6% vs 59.7 ± 11.9%, p < 0.00001-measured at resting heart rate of 60 beats per minute) while the second component demonstrated larger proportion of the QRS power in males compared to females (33.1 ± 11.9% vs 29.6 ± 11.4%, p < 0.001). The analysis also showed that the components attributable to localised depolarisation sequence abnormalities were significantly larger in males compared to females (2.85 ± 1.08% vs 2.42 ± 0.87%, p < 0.00001). In addition to the demonstration of the technology, the study concludes that the detailed convolution of the depolarisation waveform is individual, and that smoother and less intricate depolarisation propagation is the mechanism likely responsible for shorter QRS duration in females.


Assuntos
Eletrocardiografia , Fenômenos Eletrofisiológicos , Coração/fisiologia , Adulto , Algoritmos , Variação Biológica da População , Biologia Computacional/métodos , Análise de Dados , Eletrocardiografia/métodos , Fenômenos Eletrofisiológicos/efeitos dos fármacos , Feminino , Voluntários Saudáveis , Coração/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , Fatores Sexuais
15.
J Electrocardiol ; 43(6): 588-94, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20667545

RESUMO

A number of morphological indices have been proposed to characterize electrocardiographic patterns of ventricular repolarization mostly studying spatial and temporal patterns of T waves. Comparisons between different clinical populations exist but data on the suitability of the T-wave descriptors to characterize and quantify physiologic regulations of ventricular repolarization are lacking. To initiate such investigations, a study was conducted comparing the influence of provoked heart rate changes on the duration of QT interval, the roundness of T wave loop expressed by the relative T wave area, and on the 3-dimensional QRS-T angle. A population of 40 healthy subjects (18 women, mean age 30.4 ± 8.1 years) was studied. In each subject, provocative tests involving changes from strict supine to unsupported sitting and to unsupported standing positions were repeated twice during each of 3 separate monitoring days. Continuous 12-lead electrocardiograms were obtained during the provocative tests. The speed of the adaptation of the repolarization descriptors to heart rate changes was characterized by λ parameters of previously published exponential decay model of R-R interval related hysteresis. The comparisons showed that the adaptation of QT interval to heart rate changes was much slower than that of the investigated T-wave morphological descriptors: the mean (SD) values of λ parameters were 5.01 ± 1.13, 12.72 ± 8.66, and 12.90 ± 11.37 for QT interval, QRS-T angle, and relative T-wave area, respectively (P < .001 for the difference between QT interval and both morphological descriptors). The study suggests that the different numerical quantifiers of vertricular repolarization that may be derived from standard electrocardiographic tracings likely represent separate and distinct physiologic entities.


Assuntos
Eletrocardiografia/métodos , Sistema de Condução Cardíaco/fisiologia , Postura/fisiologia , Adulto , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
Diagnostics (Basel) ; 10(12)2020 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-33339231

RESUMO

QT interval variability, mostly expressed by QT variability index (QTVi), has repeatedly been used in risk diagnostics. Physiologic correlates of QT variability expressions have been little researched especially when measured in short 10-second electrocardiograms (ECGs). This study investigated different QT variability indices, including QTVi and the standard deviation of QT interval durations (SDQT) in 657,287 10-second ECGs recorded in 523 healthy subjects (259 females). The indices were related to the underlying heart rate and to the 10-second standard deviation of RR intervals (SDRR). The analyses showed that both QTVi and SDQT (as well as other QT variability indices) were highly statistically significantly (p < 0.00001) influenced by heart rate and that QTVi showed poor intra-subject reproducibility (coefficient of variance approaching 200%). Furthermore, sequential analysis of regression variance showed that SDQT was more strongly related to the underlying heart rate than to SDRR, and that QTVi was influenced by the underlying heart rate and SDRR more strongly than by SDQT (p < 0.00001 for these comparisons of regression dependency). The study concludes that instead of QTVi, simpler expressions of QT interval variability, such as SDQT, appear preferable for future applications especially if multivariable combination with the underlying heart rate is used.

17.
Front Physiol ; 11: 595815, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33384609

RESUMO

The electrocardiographic (ECG) assessment of the T peak-T end (Tpe) intervals has been used in many clinical studies, but several related physiological aspects have not been reported. Specifically, the sources of the Tpe differences between different ECG leads have not been systematically researched, the relationship of Tpe duration to underlying heart rate has not been firmly established, and little is known about the mutual correspondence of Tpe intervals measured in different ECG leads. This study evaluated 796,620 10-s 12-lead ECGs obtained from long-term Holters recorded in 639 healthy subjects (311 female) aged 33.8 ± 9.4 years. For each ECG, transformation to orthogonal XYZ lead was used to measure Tpe in the orthogonal vector magnitude (used as a reference for lead-to-lead comparisons) and to construct a three-dimensional T wave loop. The loop roundness was expressed by a ratio between its circumference and length. These ratios were significantly related to the standard deviation of Tpe durations in different ECG leads. At the underlying heart rate of 60 beats per minute, Tpe intervals were shorter in female than in male individuals (82.5 ± 5.6 vs 90.0 ± 6.5 ms, p < 0.0001). When studying linear slopes between Tpe intervals measured in different leads and the underlying heart rate, we found only minimal heart rate dependency, which was not systematic across the ECG leads and/or across the population. For any ECG lead, positive Tpe/RR slope was found in some subjects (e.g., 79 and 25% of subjects for V2 and V4 measurements, respectively) and a negative Tpe/RR slope in other subjects (e.g., 40 and 65% for V6 and V5, respectively). The steepest positive and negative Tpe/RR slopes were found for measurements in lead V2 and V4, respectively. In all leads, the Tpe/RR slope values were close to zero, indicating, on average, Tpe changes well below 2 ms for RR interval changes of 100 ms. On average, longest Tpe intervals were measured in lead V2, the shortest in lead III. The study concludes that the Tpe intervals measured in different leads cannot be combined. Irrespective of the measured ECG lead, the Tpe interval is not systematically heart rate dependent, and no heart rate correction should be used in clinical Tpe investigations.

18.
Sci Rep ; 10(1): 2551, 2020 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-32054960

RESUMO

On standard electrocardiogram (ECG) PQ interval is known to be moderately heart rate dependent, but no physiologic details of this dependency have been established. At the same time, PQ dynamics is a clear candidate for non-invasive assessment of atrial abnormalities including the risk of atrial fibrillation. We studied PQ heart rate dependency in 599 healthy subjects (aged 33.5 ± 9.3 years, 288 females) in whom drug-free day-time 12-lead ECG Holters were available. Of these, 752,517 ECG samples were selected (1256 ± 244 per subject) to measure PQ and QT intervals and P wave durations. For each measured ECG sample, 5-minute history of preceding cardiac cycles was also obtained. Although less rate dependent than the QT intervals (36 ± 19% of linear slopes), PQ intervals were found to be dependent on underlying cycle length in a highly curvilinear fashion with the dependency significantly more curved in females compared to males. The PQ interval also responded to the heart rate changes with a delay which was highly sex dependent (95% adaptation in females and males after 114.9 ± 81.1 vs 65.4 ± 64.3 seconds, respectively, p < 0.00001). P wave duration was even less rate dependent than the PQ interval (9 ± 10% of linear QT/RR slopes). Rate corrected P wave duration was marginally but significantly shorter in females than in males (106.8 ± 8.4 vs 110.2 ± 7.9 ms, p < 0.00001). In addition to establishing physiologic standards, the study suggests that the curvatures and adaptation delay of the PQ/cycle-length dependency should be included in future non-invasive studies of atrial depolarizations.


Assuntos
Eletrocardiografia Ambulatorial , Sistema de Condução Cardíaco/fisiologia , Frequência Cardíaca/fisiologia , Coração/diagnóstico por imagem , Potenciais de Ação/fisiologia , Adulto , Função Atrial , Eletrocardiografia , Feminino , Coração/fisiologia , Determinação da Frequência Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Caracteres Sexuais , Adulto Jovem
19.
Front Physiol ; 10: 994, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31427990

RESUMO

Accurate evaluation of the appearance of QTc sex differences during childhood and adolescence is intricate. Inter-subject differences of individual QT/RR patterns make generic heart rate corrections inaccurate because of fast resting heart rates in children. The study investigated 527 healthy children and adolescents aged 4-19 years (268 females, 50.9%). All underwent continuous ECG 12-lead monitoring while performing postural changes during a 70-min investigative protocol to obtain QT interval measurements at different heart rates. On average, more than 1200 ECG measurements (QT interval and its 5-min history of preceding RR intervals) were made in each subject. Curvilinear QT/RR regression involving intra-individual correction for QT/RR hysteresis were calculated in each subject. The projection of the QT/RR regressions to the heart rate of 60 beats per minute defined individually corrected QTc intervals. In males, gradual QTc shortening by about 15 ms appeared during the ages of 13-19 years synchronously with the incidence of secondary sex signs (p = 0.016). On the contrary, whilst gradual QTc prolongation by about 10 ms appeared in females, it occurred only during ages 16-19 years and was not related to the incidence of secondary sex signs (p = 0.18). The study also showed that in children and adolescents, linear QT/RR models fit the intra-subject data significantly more closely than the log-linear models (p < 0.001). The study speculates that hormonal shifts during puberty might be directly responsible for the QTc shortening in males but that QTc prolongation in females is likely more complex since it was noted to follow the appearance of secondary sex signs only after a considerable delay.

20.
Sci Rep ; 9(1): 19880, 2019 12 27.
Artigo em Inglês | MEDLINE | ID: mdl-31882660

RESUMO

To facilitate the precision of clinical electrocardiographic studies of J-to-Tpeak (JTp) and Tpeak-to-Tend (Tpe) intervals, the study investigated their differences between healthy females and males, and between subjects of African and Caucasian origin. In 523 healthy subjects (254 females; 236 subjects of African origin), repeated Holter recordings were used to measure QT, JT, JTp, and Tpe intervals preceded by both stable and variable heart rates. Subject-specific curvilinear regression models were used to obtain individual QTc, JTc, JTpc and Tpec intervals. Rate hysteresis, i.e., the speed with which the intervals adapted after heart rate changes, was also investigated. In all sex-race groups, Tpe intervals were not systematically heart rate dependent. Similar to QTc intervals, women had JTc, and JTpc intervals longer than males (difference 20-30 ms, p < 0.001). However, women had Tpec intervals (and rate uncorrected Tpe intervals) shorter by approximately 10 ms compared to males (p < 0.001). Subjects of African origin had significantly shorter QTc intervals than Caucasians (p < 0.001). Gradually diminishing race-difference was found for JTc, JTpc and Tpec intervals. JTc and JTpc were moderately increasing with age but Tpe/Tpec were not. Rate hysteresis of JTp was approximately 10% longer compared to that of JT (p < 0.001). In future clinical studies, Tpe interval should not be systematically corrected for heart rate and similar to the QT interval, the differences in JT, JTp and Tpe intervals should be corrected for sex. The differences in QT and JT, and JTp intervals should also be corrected for race.


Assuntos
Eletrocardiografia , Sistema de Condução Cardíaco/fisiologia , Frequência Cardíaca/fisiologia , Grupos Raciais , Caracteres Sexuais , Adulto , Feminino , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA