Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Environ Res ; 262(Pt 2): 119864, 2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39216734

RESUMO

Biofouling in membrane distillation (MD) has several repercussions, including reduced efficiency of the MD process and limiting membrane life. Additionally, the evaluation of MD biofouling using treated effluents from wastewater treatment plants remains an unexplored area. Thus, biofouling formation and development in a long term MD process (15 days) using treated effluent from a wastewater treatment plant was explored in this study. The results revealed that flux decline occurred in four phases: i) initial decline (0-1 d), ii) gradual decline (1-5 d), iii) progressive decline (5-10 d), and iv) rapid decline (10-15 d). Liquid Chromatography-Organic Carbon Detection (LC-OCD) analysis demonstrated that the treated effluent contained humic-like substances, which deposited on the membrane surface in phase 1. Whereas biopolymers development on the membrane surface in phase 2 and 3 was linked to biofouling. Microbial community analysis revealed that the initial colonisers were predominantly thermophilic bacteria, which were different from the microbial community of the treated effluent. The biofilm-forming bacteria included Schlegelella, Meiothermus, and Vulcaniibacterium. These microorganisms proliferate and release excessive extracellular polymeric substances (EPS), leading to the development of mature biofilm on membrane surface. This helped in the deposition of organics and inorganics from the bulk feed, which led to microbial community succession in phase 4 with the emergence of the Kallotenue genus. The results suggested that organic substances and microbial communities on membrane surface at different stages in a long-term MD process had a significant influence on MD performance for high-quality wastewater reuse.

2.
Water Sci Technol ; 89(5): 1325-1339, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38483501

RESUMO

Fouling behaviour in membrane distillation (MD) processes plays a crucial role in determining their widespread acceptability. Most studies have primarily focused on model organic foulants, such as humic acid (HA) and sodium alginate (SA). This study investigates the fouling of a polytetrafluoroethylene membrane in a direct contact MD (DCMD) using model organics (i.e., HA and SA) and real wastewater. The results indicated that the flux decline (5-60%) was only observed during the initial phase of the operation with model organic foulants. In contrast, real wastewater caused a gradual decline in flux throughout the experiment in both the concentrate (40%) and continuous (90%) modes. The study also found significant differences in the fouling layer morphology, composition, and hydrophobicity between the model organic foulants and real wastewater. Fourier transform infrared spectroscopy findings demonstrated that the fouling layer formed by real wastewater varied significantly from model organics, which primarily comprised of protein-like and polysaccharide-like functional groups. Finally, liquid chromatography-organic carbon detection revealed that the fouling layer of the MD membrane with real wastewater was composed of 40.7% hydrophobic and 59.3% hydrophilic organics. This study suggests that model organics may not accurately reflect real wastewater fouling.


Assuntos
Alginatos , Águas Residuárias , Carbono , Cromatografia Líquida , Destilação
3.
J Environ Manage ; 291: 112723, 2021 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-33940362

RESUMO

The past decade has seen the rapid development of constructed wetland-microbial fuel cell (CW-MFC) technology in many aspects. The first publication on the combination of constructed wetland (CW) and microbial fuel cell (MFC) appeared in 2012, subsequently, research on the subject has grown exponentially to improve the performance of CW-MFCs in their dual roles of wastewater treatment and power generation. Although significant research has been conducted on this technology worldwide, a comprehensive and critical review of effective controlling parameters is lacking. More broadly, research is needed to draw up-to-date conclusions on recent developments and to identify knowledge gaps for further studies. This review paper systematically enumerates and reviews research studies published in this area to determine the key design factors and their role in CW-MFC performance. Moreover, a taxonomy of all CW-MFC design parameters has been synthesised from the literature. Importantly, this original work provides a comprehensive conceptual framework for future researchers, designers, builders, and users to understand CW-MFC technology. Within the taxonomy, parameters are placed in three main categories (physical/environmental, chemical, and biological/electrochemical) and comprehensive details are given for each parameter. Finally, a comprehensive summary of the parameters has been tabulated showing their impact on CW-MFC operation, design recommendations from literature, and the significant research gaps that this review has identified within the existing literature. It is hoped that this paper will provide a clear and rich picture of this technology at its current stage of development and furthermore, will facilitate a deeper understanding of CW-MFC performance for long-term and large-scale development.


Assuntos
Fontes de Energia Bioelétrica , Eletricidade , Eletrodos , Águas Residuárias , Áreas Alagadas
4.
J Environ Manage ; 180: 133-46, 2016 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-27213866

RESUMO

Dairy farm milking operations produce considerable amounts of carbon- and nutrient-rich effluent that can be a vital source of nutrients for pasture and crops. The study aim was to characterise dairy shed effluent from a commercial farm and examine the changes produced by treatment, storage and recycling of the effluent through a two-stage stabilisation pond system. The data and insights from the study are broadly applicable to passive pond systems servicing intensive dairy and other livestock operations. Raw effluent contained mostly poorly biodegradable particulate organic material and organically bound nutrients, as well as a large fraction of fixed solids due to effluent recycling. The anaerobic pond provided effective sedimentation and biological treatment, but hydrolysis of organic material occurred predominantly in the sludge and continually added to effluent soluble COD, nutrients and cations. Sludge digestion also suppressed pH in the pond and increased salt levels through formation of alkalinity. High sludge levels significantly impaired pond treatment performance. In the facultative pond, BOD5 concentrations were halved; however smaller reductions in COD showed the refractory nature of incoming organic material. Reductions in soluble N and P were proportional to reductions in respective particulate forms, suggesting that respective removal mechanisms were not independent. Conditions in the ponds were unlikely to support biological nutrient removal. Recycling caused conservative inert constituents to accumulate within the pond system. Material leaving the system was mostly soluble (86% TS) and inert (65% TS), but salt concentrations remained below thresholds for safe land application.


Assuntos
Criação de Animais Domésticos , Indústria de Laticínios , Esgotos , Eliminação de Resíduos Líquidos , Animais , Bovinos , Feminino , New South Wales , Lagoas , Reciclagem , Purificação da Água/métodos
5.
Water Res ; 233: 119796, 2023 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-36863281

RESUMO

Carbapenems are last-resort antibiotics used to treat bacterial infections unsuccessfully treated by most common categories of antibiotics in humans. Most of their dosage is secreted unchanged as waste, thereby making its way into the urban water system. There are two major knowledge gaps addressed in this study to gain a better understanding of the effects of their residual concentrations on the environment and environmental microbiome: development of a UHPLC-MS/MS method of detection and quantification from raw domestic wastewater via direct injection and study of their stability in sewer environment during the transportation from domestic sewers to wastewater treatment plants. The UHPLC-MS/MS method was developed for four carbapenems: meropenem, doripenem, biapenem and ertapenem, and validation was performed in the range of 0.5-10 µg/L for all analytes, with limit of detection (LOD) and limit of quantification (LOQ) values ranging from 0.2-0.5 µg/L and 0.8-1.6 µg/L respectively. Laboratory scale rising main (RM) and gravity sewer (GS) bioreactors were employed to culture mature biofilms with real wastewater as the feed. Batch tests were conducted in RM and GS sewer bioreactors fed with carbapenem-spiked wastewater to evaluate the stability of carbapenems and compared against those in a control reactor (CTL) without sewer biofilms, over a duration of 12 h. Significantly higher degradation was observed for all carbapenems in RM and GS reactors (60 - 80%) as opposed to CTL reactor (5 - 15%), which indicates that sewer biofilms play a significant role in the degradation. First order kinetics model was applied to the concentration data along with Friedman's test and Dunn's multiple comparisons analysis to establish degradation patterns and differences in the degradation observed in sewer reactors. As per Friedman's test, there was a statistically significant difference in the degradation of carbapenems observed depending on the reactor type (p = 0.0017 - 0.0289). The results from Dunn's test indicate that the degradation in the CTL reactor was statistically different from that observed in either RM (p = 0.0033 - 0.1088) or GS (p = 0.0162 - 0.1088), with the latter two showing insignificant difference in the degradation rates observed (p = 0.2850 - 0.5930). The findings contribute to the understanding about the fate of carbapenems in urban wastewater and the potential application of wastewater-based epidemiology.


Assuntos
Esgotos , Águas Residuárias , Humanos , Carbapenêmicos , Espectrometria de Massas em Tandem , Reatores Biológicos , Biofilmes , Antibacterianos
6.
Sci Total Environ ; 892: 164574, 2023 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-37268129

RESUMO

Campylobacter spp. is one of the most frequent pathogens of bacterial gastroenteritis recorded worldwide. Campylobacter jejuni (C. jejuni) and Campylobacter coli (C. coli) are the two major disease-associated species, accounting for >95 % of infections, and thus have been selected for disease surveillance. Monitoring temporal variations in pathogen concentration and diversity excreted from community wastewater allows the early detection of outbreaks. Multiplex real-time/quantitative PCR (qPCR) enables multi-target quantification of pathogens in various types of samples including wastewater. Also, an internal amplification control (IAC) is required for each sample when adopting PCR-based methods for pathogen detection and quantification in wastewater to exclude the inhibition of the wastewater matrix. To achieve reliable quantification of C. jejuni and C. coli towards wastewater samples, this study developed and optimized a triplex qPCR assay by combining three qPCR primer-probe sets targeting Campylobacter jejuni subsp. jejuni, Campylobacter coli, and Campylobacter sputorum biovar sputorum (C. sputorum), respectively. This triplex qPCR assay not only can directly and simultaneously detect the concentration of C. jejuni and C. coli in wastewater but also can achieve the PCR inhibition control using C. sputorum primer-probe set. This is the first developed triplex qPCR assay with IAC for C. jejuni and C. coli, to be used in the wastewater-based epidemiology (WBE) applications. The optimized triplex qPCR assay enables the detection limit of the assay (ALOD100%) and wastewater (PLOD80%) as 10 gene copy/µL and 2 log10 cells/mL (2 gene copies/µL of extracted DNA), respectively. The application of this triplex qPCR to 52 real raw wastewater samples from 13 wastewater treatment plants demonstrated its potential as a high-throughput and economically viable tool for the long-term monitoring of C. jejuni and C. coli prevalence in communities and the surrounding environments. This study provided an accessible methodology and a solid foundation for WBE-based monitoring of Campylobacter spp. relevant diseases and paved the road for future WBE back-estimation of C. jejuni and C. coli prevalence.


Assuntos
Campylobacter coli , Campylobacter jejuni , Campylobacter , Campylobacter jejuni/genética , Campylobacter coli/genética , Águas Residuárias , Sensibilidade e Especificidade , DNA Bacteriano/análise
7.
Water Res ; 233: 119737, 2023 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-36801582

RESUMO

Campylobacter jejuni and coli are two main pathogenic species inducing diarrhoeal diseases in humans, which are responsible for the loss of 33 million lives each year. Current Campylobacter infections are mainly monitored by clinical surveillance which is often limited to individuals seeking treatment, resulting in under-reporting of disease prevalence and untimely indicators of community outbreaks. Wastewater-based epidemiology (WBE) has been developed and employed for the wastewater surveillance of pathogenic viruses and bacteria. Monitoring the temporal changes of pathogen concentration in wastewater allows the early detection of disease outbreaks in a community. However, studies investigating the WBE back-estimation of Campylobacter spp. are rare. Essential factors including the analytical recovery efficiency, the decay rate, the effect of in-sewer transport, and the correlation between the wastewater concentration and the infections in communities are lacking to support wastewater surveillance. This study carried out experiments to investigate the recovery of Campylobacter jejuni and coli from wastewater and the decay under different simulated sewer reactor conditions. It was found that the recovery of Campylobacter spp. from wastewater varied with their concentrations in wastewater and depended on the detection limit of quantification methods. The concentration reduction of Campylobacter. jejuni and coli in sewers followed a two-phase reduction model, and the faster concentration reduction during the first phase is mainly due to their partitioning onto sewer biofilms. The total decay of Campylobacter. jejuni and coli varied in different types of sewer reactors, i.e. rising main vs. gravity sewer. In addition, the sensitivity analysis for WBE back-estimation of Campylobacter suggested that the first-phase decay rate constant (k1) and the turning time point (t1) are determining factors and their impacts increased with the hydraulic retention time of wastewater.


Assuntos
Infecções por Campylobacter , Campylobacter coli , Campylobacter jejuni , Humanos , Águas Residuárias , Vigilância Epidemiológica Baseada em Águas Residuárias , Biofilmes , Infecções por Campylobacter/epidemiologia
8.
Sci Total Environ ; 819: 152000, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34843787

RESUMO

Measurement of pathogens in raw wastewater from a population within certain sewer catchments can provide quantitative information on public health status within the sampled urban area. This so-called wastewater-based epidemiology (WBE) approach has the potential of becoming a powerful tool to monitor pathogen circulation and support timely intervention during outbreaks. However, many WBE studies failed to account for the pathogen decay during wastewater transportation in back calculating the disease prevalence. Various sewer process factors, including water temperature and infiltration/inflow, can lead to the variation of pathogen decay rates. This paper firstly reviewed the effects of temperature and types of water, i.e., wastewater, freshwater, and saline water, on the decay of four selected enteric pathogens, i.e., Campylobacter, Salmonella, Norovirus, and Adenovirus. To elucidate the importance of the pathogen decay rates (measured by culture and molecular methods) to WBE, a sensitivity analysis was conducted on the back-calculation equation for infection prevalence with decay rates collected from published literature. It was found that WBE back-calculation is more sensitive to decay rates under the condition of high wastewater temperature (i.e., over 25 °C) or if wastewater is diluted by saline water (i.e., sewer infiltration or use of seawater as an alternative source of freshwater constituting around 1/3 household water demand in some cities). Stormwater dilution of domestic wastewater (i.e., sewer inflow might achieve 10 times volumetric dilution) was shown to play a role in increasing the sensitivity of WBE back-calculation to bacterial pathogens, but not viral pathogens. Hence, WBE back-calculation in real sewers should account for in-sewer decay of specific pathogen species under different wastewater temperatures and dilutions. Overall, this review contributes to a better understanding of pathogen decay in wastewater which can lead to improved accuracy of WBE back-calculation.


Assuntos
Vigilância Epidemiológica Baseada em Águas Residuárias , Águas Residuárias , Bactérias , Cidades , Temperatura
9.
Water Res ; 219: 118610, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35598472

RESUMO

The amount of norovirus RNA (Ribonucleic Acid) in raw wastewater, collected from a wastewater treatment plant (WWTP), can provide an indication of disease prevalence within the sampled catchment. However, an accurate back-estimation might be impeded by the uncertainties from in-sewer/in-sample degradation of viral RNA, variable shedding magnitude, and difficulties in measurement within raw wastewater. The current study reviewed the published literature regarding the factors of norovirus shedding, viral RNA decay in wastewater, and the occurrence of norovirus RNA in raw wastewater based on molecular detection. Sensitivity analysis for WBE back-estimation was conducted using the reported data of the factors mentioned above considering different viral loads in wastewater samples. It was found that the back-estimation is more sensitive to analytical detection uncertainty than shedding variability for norovirus. Although seasonal temperature change can lead to variation of decay rates and may influence the sensitivity of this pathogen-specific parameter, decay rates of norovirus RNA contribute negligibly to the variance in estimating disease prevalence, based on the available data from decay experiments in bulk wastewater under different temperatures. However, the effects of in-sewer transportation on viral RNA decay and retardation by sewer biofilms on pipe surfaces are largely unknown. Given the highest uncertainty from analytical measurement by molecular methods and complexity of in-sewer processes that norovirus experienced during the transportation to WWTP, future investigations are encouraged to improve the accuracy of viral RNA detection in wastewater and delineate viral retardation/interactions with wastewater biofilms in real sewers.


Assuntos
Infecções por Caliciviridae , Norovirus , Biofilmes , Infecções por Caliciviridae/epidemiologia , Humanos , Norovirus/genética , RNA Viral , Águas Residuárias
10.
Sci Total Environ ; 806(Pt 2): 150572, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34582851

RESUMO

Current studies have confirmed the feasibility of SARS-CoV-2 RNA detection by RT-qPCR assays in wastewater samples as an effective surveillance tool of COVID-19 prevalence in a community. Analytical performance of various RT-qPCR assays has been compared against wastewater samples based on the positive ratio. However, there is no systematic comparison work has been conducted for both analytical sensitivity and quantitative reliability against wastewater, which are essential factors for WBE. In this study, the detection performance of four RT-qPCR primer-probe sets, including CCDC-N, CDC-N1, N-Sarbeco, and E-Sarbeco, was systematically evaluated with pure synthetized plasmids, spiked wastewater mocks and raw wastewater samples. In addition to confirm RT-qPCR results, Nanopore sequencing was employed to delineate at molecular level for the analytical sensitivity and reproducibility of those primer-probe sets. CCDC-N showed high sensitivity and the broadest linearity range for wastewater samples. It was thus recommended to be the most efficient tool in the quantitative analysis of SARS-CoV-2 in wastewater. CDC-N1 had the highest sensitivity for real wastewater and thus would be suitable for the screening of wastewater for the presence of SARS-CoV-2. When applying the primer-probe sets to wastewater samples collected from different Australian catchments, increased active clinical cases were observed with the augment of SARS-CoV-2 RNA quantified by RT-qPCR in wastewater in low prevalence communities.


Assuntos
COVID-19 , SARS-CoV-2 , Austrália , Humanos , RNA Viral , Reprodutibilidade dos Testes , Águas Residuárias
11.
Sci Total Environ ; 813: 151919, 2022 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-34826473

RESUMO

Recent outbreaks caused by coronaviruses and their supposed potential fecal-oral transmission highlight the need for understanding the survival of infectious coronavirus in domestic sewers. To date, the survivability and decay of coronaviruses were predominately studied using small volumes of wastewater (normally 5-30 mL) in vials (in-vial tests). However, real sewers are more complicated than bulk wastewater (wastewater matrix only), in particular the presence of sewer biofilms and different operational conditions. This study investigated the decay of infectious human coronavirus 229E (HCoV-229E) and feline infectious peritonitis virus (FIPV), two typical surrogate coronaviruses, in laboratory-scale reactors mimicking the gravity (GS, gravity-driven sewers) and rising main sewers (RM, pressurized sewers) with and without sewer biofilms. The in-sewer decay of both coronaviruses was greatly enhanced in comparison to those reported in bulk wastewater through in-vial tests. 99% of HCoV-229E and FIPV decayed within 2 h under either GS or RM conditions with biofilms, in contrast to 6-10 h without biofilms. There is limited difference in the decay of HCoV and FIPV in reactors operated as RM or GS, with the T90 and T99 difference of 7-10 min and 14-20 min, respectively. The decay of both coronaviruses in sewer biofilm reactors can be simulated by biphasic first-order kinetic models, with the first-order rate constant 2-4 times higher during the first phase than the second phase. The decay of infectious HCoV and FIPV was significantly faster in the reactors with sewer biofilms than in the reactors without biofilms, suggesting an enhanced decay of these surrogate viruses due to the presence of biofilms and related processes. The mechanism of biofilms in virus adsorption and potential inactivation remains unclear and requires future investigations. The results indicate that the survivability of infectious coronaviruses detected using bulk wastewater overestimated the infectivity risk of coronavirus during wastewater transportations in sewers or the downstream treatment.


Assuntos
Coronavirus , Águas Residuárias , Biofilmes , Humanos , Cinética , Esgotos
12.
Sci Total Environ ; 789: 147947, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34051491

RESUMO

Wastewater-based epidemiology (WBE) has been regarded as a potential tool for the prevalence estimation of coronavirus disease 2019 (COVID-19) in the community. However, the application of the conventional back-estimation approach is currently limited due to the methodological challenges and various uncertainties. This study systematically performed meta-analysis for WBE datasets and investigated the use of data-driven models for the COVID-19 community prevalence in lieu of the conventional WBE back-estimation approach. Three different data-driven models, i.e. multiple linear regression (MLR), artificial neural network (ANN), and adaptive neuro fuzzy inference system (ANFIS) were applied to the multi-national WBE dataset. To evaluate the robustness of these models, predictions for sixteen scenarios with partial inputs were compared against the actual prevalence reports from clinical testing. The performance of models was further validated using unseen data (data sets not included for establishing the model) from different stages of the COVID-19 outbreak. Generally, ANN and ANFIS models showed better accuracy and robustness over MLR models. Air and wastewater temperature played a critical role in the prevalence estimation by data-driven models, especially MLR models. With unseen datasets, ANN model reasonably estimated the prevalence of COVID-19 (cumulative cases) at the initial phase and forecasted the upcoming new cases in 2-4 days at the post-peak phase of the COVID-19 outbreak. This study provided essential information about the feasibility and accuracy of data-driven estimation of COVID-19 prevalence through the WBE approach.


Assuntos
COVID-19 , Vigilância Epidemiológica Baseada em Águas Residuárias , Humanos , Prevalência , SARS-CoV-2 , Águas Residuárias
13.
J Environ Manage ; 91(2): 516-22, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19815333

RESUMO

Nitrate levels are limited due to health concerns in potable water. Nitrate is a common contaminant in water supplies, and especially prevalent in surface water supplies and shallow wells. Nitrate is a stable and highly soluble ion with low potential for precipitation or adsorption. These properties make it difficult to remove using conventional water treatment methods. A laboratory batch electrocoagulation/flotation (ECF) reactor was designed to investigate the effects of different parameters such as electrolysis time, electrolyte pH, initial nitrate concentration, and current rate on the nitrate removal efficiency. The optimum nitrate removal was observed at a pH range of between 9 and 11. It appeared that the nitrate removal rate was 93% when the initial nitrate concentration and electrolysis time respectively were 100 mg L(-1)-NO(3)(-) and 40 min. The results showed a linear relationship between the electrolysis time for total nitrate removal and the initial nitrate concentration. It is concluded that the electrocoagulation technology for denitrification can be an effective preliminary process when the ammonia byproduct must be effectively removed by the treatment facilities.


Assuntos
Eletroquímica , Floculação , Nitratos/isolamento & purificação , Poluentes da Água/isolamento & purificação , Concentração de Íons de Hidrogênio , Oxirredução
14.
J Environ Manage ; 90(5): 1663-79, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19181438

RESUMO

The word "electrocoagulation" (EC) will be sometimes used with "electroflotation" (EF) and can be considered as the electrocoagulation/flotation (ECF) process. Through the process of electrolysis, coagulating agents such as metal hydroxides are produced. When aluminium electrodes are used, the aluminium dissolves at the anode and hydrogen gas is released at the cathode. The coagulating agent combines with the pollutants to form large size flocs. As the bubbles rise to the top of the tank they adhere to particles suspended in the water and float them to the surface. In fact, a conceptual framework of the overall ECF process is linked to coagulant generation, pollutant aggregation, and pollutant removal by flotation and settling when it has been applied efficiently to various water and wastewater treatment processes. This review paper considers a significant number of common applications of EC and ECF processes which have been published in journal and conference papers.


Assuntos
Eletroquímica , Eliminação de Resíduos Líquidos/métodos , Poluentes Químicos da Água , Purificação da Água/métodos , Alumínio/química , Eletrólise , Resíduos Industriais
15.
Water Sci Technol ; 58(11): 2143-53, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19092190

RESUMO

The lack of drinking water was one of the hot environmental issues that focused on the contaminants released from the failure of sanitary systems. Organic carbon and nitrate compounds were concerned since they represented a potential risk to human health and environment. Mathematical modelling was an effective tool for understanding and estimating the fate and transport of contaminants. An organic carbon and nitrate compounds transport model was developed using the mass balance concept. Richards and multiplicative Monod equations supported the estimating of advection-dispersion transport and biodegradation processes, respectively. The numerical solutions were obtained using the MATLAB programme. The model capability was evaluated using pilot scale experimental data. The depth-averaged time series of pressure head and contaminants concentration profiles were measured several times a week during 91 days. Simulations were found to provide reasonable agreement with the observed data. The aerobic biodegradation zone was observed within 15 cm depth of soil column. Even though the column was operated for 91 days, soil microbes were enough to retard these contaminants. This confirmed that the developed model could be applied to simulate the transport of the contaminants under real time boundary conditions.


Assuntos
Carbono/metabolismo , Movimento (Física) , Nitratos/metabolismo , Compostos Orgânicos/metabolismo , Solo , Amônia/análise , Biodegradação Ambiental , Biotransformação , Simulação por Computador , Nitratos/análise , Oxigênio/análise , Projetos Piloto , Pressão , Fatores de Tempo , Movimentos da Água , Poluentes Químicos da Água
16.
J Hazard Mater ; 131(1-3): 118-25, 2006 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-16298054

RESUMO

Excessive presence of fluoride concentration in community water supplies can cause fluorosis that affects the teeth and bones. Batch experiments with monopolar aluminium electrodes for fluoride removal were conducted and an empirical model is developed using critical parameters such as current concentration, electrode distance, and initial fluoride concentration. Fluoride ions were removed electrochemically from solution by electrocoagulation/flotation (ECF) process. The electrolytic dissolution of aluminium anodes in water produced aqueous Al3+ species and hydrogen bubbles at the aluminium cathodes. The fluoride removal efficiency increases steadily with increasing current values from 1 to 2.5 A. In the batch monopolar ECF process, the optimal detention time (dto) was found to be 55 min when the operational parameters including initial F- concentration, current value, and inter electrode distance were respectively kept at 10 mg/l, 1.5 A, and 5 mm. The experimental results showed that the rate constant (K) for defluoridation by monopolar ECF process depends on the current concentration (I/V), electrode distance (d) and initial fluoride concentration (C0). The Al3+/F- mass ratio is found to be not significantly different between monopolar and bipolar ECF systems. Overall, the results showed that the electrocoagulation technology is an effective process for defluoridation of water.


Assuntos
Eletroquímica/métodos , Fluoretos/isolamento & purificação , Eliminação de Resíduos Líquidos/métodos , Poluentes Químicos da Água/isolamento & purificação , Purificação da Água/métodos , Precipitação Química , Cinética , Modelos Teóricos
17.
Bioresour Technol ; 101(5): 1494-500, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19864128

RESUMO

Experiments were conducted over approximately 7 months to investigate the effects of mixed liquor pH (between pH 5 and 9) on the removal of trace organics by a submerged MBR system. Removal efficiencies of ionisable trace organics (sulfamethoxazole, ibuprofen, ketoprofen, and diclofenac) were strongly pH dependent. However, the underlying removal mechanisms are different for ionisable and non-ionisable compounds. High removal efficiencies of these ionisable trace organics at pH 5 could possibly be attributed to their speciation behaviour. At this pH, these compounds exist predominantly in their hydrophobic form. Consequently, they could readily adsorb to the activated sludge, resulting in higher removal efficiency in comparison to under less acidic conditions in the reactor. Removal efficiencies of the two non-ionisable compounds bisphenol A and carbamazepine were relatively independent of the mixed liquor pH. Results reported here suggest an apparent connection between physicochemical properties of the compounds and their removal efficiencies by MBRs.


Assuntos
Reatores Biológicos , Membranas Artificiais , Compostos Orgânicos/isolamento & purificação , Poluentes Químicos da Água/isolamento & purificação , 1-Octanol/química , Adsorção , Biodegradação Ambiental , Reatores Biológicos/microbiologia , Concentração de Íons de Hidrogênio , Modelos Químicos , Nitrogênio/isolamento & purificação , Compostos Orgânicos/química , Oxigênio/isolamento & purificação , Esgotos/microbiologia , Relação Estrutura-Atividade , Água/química
18.
J Environ Manage ; 90(2): 1204-12, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18649987

RESUMO

Long-term consumption of water containing excessive fluoride can lead to fluorosis of the teeth and bones. Electrocoagulation (EC) is an electrochemical technique, in which a variety of unwanted dissolved particles and suspended matter can be effectively removed from an aqueous solution by electrolysis. Continuous flow experiments with monopolar aluminium electrodes for fluoride removal were undertaken to investigate the effects of the different parameters such as: current density (12.5-50A/m(2)), flow rate (150-400 mL/min), initial pH (4-8), and initial fluoride concentration (5-25mg/L). The highest treatment efficiency was obtained for the largest current and the removal efficiency was found to be dependent on the current density, the flow rate and the initial fluoride concentration when the final pH ranged between 6 and 8. The composition of the sludge produced was analysed using the X-ray diffraction (XRD) spectrum. The strong presence of the aluminium hydroxide [Al(OH)(3)] in the above pH range, which maximizes the formation of aluminium fluoride hydroxide complex [Al(n)F(m)(OH)(3n-m)], is the main reason for defluoridation by electrocoagulation. The results obtained showed that the continuous flow electrocoagulation technology is an effective process for defluoridation of potable water supplies and could also be utilized for the defluoridation of industrial wastewater.


Assuntos
Eletroquímica/métodos , Fluoretos/isolamento & purificação , Esgotos , Difração de Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA