Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Eur J Pediatr ; 182(6): 2577-2589, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36939879

RESUMO

Diaphragmatic thickness (Tdi) and diaphragm thickening fraction (dTF) are widely used parameters in ultrasound studies of the diaphragm in mechanically ventilated children, but normal values for healthy children are scarce. We determined reference values of Tdi and dTF using ultrasound in healthy children aged 0-8 years old and assessed their reproducibility. In a prospective, observational cohort, Tdi and dTF were measured on ultrasound images across four age groups comprising at least 30 children per group: group 1 (0-6 months), group 2 (7 months-1 year), group 3 (2-4 years) and group 4 (5-8 years). Ultrasound images of 137 healthy children were included. Mean Tdi at inspiration was 2.07 (SD 0.40), 2.09 (SD 0.40), 1.69 (SD 0.30) and 1.72 (SD 0.30) mm for groups 1, 2, 3 and 4, respectively. Mean Tdi at expiration was 1.64 (SD 0.30), 1.67 (SD 0.30), 1.38 (SD 0.20) and 1.42 (SD 0.20) mm for groups 1, 2, 3 and 4, respectively. Mean Tdi at inspiration and mean Tdi at expiration for groups 1 and 2 were significantly greater than those for groups 3 and 4 (both p < 0.001). Mean dTF was 25.4% (SD 10.4), 25.2% (SD 8.3), 22.8% (SD 10.9) and 21.3% (SD 7.1) for group 1, 2, 3 and 4, respectively. The intraclass correlation coefficients (ICC) representing the level of inter-rater reliability between two examiners performing the ultrasounds was 0.996 (95% CI 0.982-0.999). ICC of the inter-rater reliability between the raters in 11 paired assessments was 0.989 (95% CI 0.973-0.995).   Conclusion: Ultrasound measurements of Tdi and dTF were highly reproducible in healthy children aged 0-8 years.    Trial registration: ClinicalTrials.gov identifier (NCT number): NCT04589910. What is Known: • Diaphragmatic thickness and diaphragm thickening fraction are widely used parameters in ultrasound studies of the diaphragm in mechanically ventilated children, but normal values for healthy children to compare these with are scarce. What is New: • We determined normal values of diaphragmatic thickness and diaphragm thickening fraction using ultrasound in 137 healthy children aged 0-8 years old. The diaphragmatic thickness of infants up to 1 year old was significantly greater than that of children from 2 to 8 years old. Diaphragmatic thickness decreased with an increase in body surface area. These normal values in healthy children can be used to assess changes in respiratory muscle thickness in mechanically ventilated children.


Assuntos
Diafragma , Respiração Artificial , Lactente , Humanos , Criança , Recém-Nascido , Pré-Escolar , Diafragma/diagnóstico por imagem , Diafragma/fisiologia , Valores de Referência , Reprodutibilidade dos Testes , Estudos Prospectivos , Ultrassonografia/métodos
2.
Front Pediatr ; 11: 1147309, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37033174

RESUMO

Introduction: In mechanically ventilated adults, thickening fraction of diaphragm (dTF) measured by ultrasound is used to predict extubation success. Whether dTF can also predict extubation success in children is unclear. Aim: To investigate the association between dTF and extubation success in children. Second, to assess diaphragm thickness during ventilation and the correlation between dTF, diaphragm thickness (Tdi), age and body surface. Method: Prospective observational cohort study in children aged 0-18 years old with expected invasive ventilation for >48 h. Ultrasound was performed on day 1 after intubation (baseline), day 4, day 7, day 10, at pre-extubation, and within 24 h after extubation. Primary outcome was the association between dTF pre-extubation and extubation success. Secondary outcome measures were Tdi end-inspiratory and Tdi end-expiratory and atrophy defined as <10% decrease of Tdi end-expiratory versus baseline at pre-extubation. Correlations were calculated with Spearman correlation coefficients. Inter-rater reliability was calculated with intraclass correlation (ICC). Results: Fifty-three patients, with median age 3.0 months (IQR 0.1-66.0) and median duration of invasive ventilation of 114.0 h (IQR 55.5-193.5), were enrolled. Median dTF before extubation with Pressure Support 10 above 5 cmH2O was 15.2% (IQR 9.7-19.3). Extubation failure occurred in six children, three of whom were re-intubated and three then received non-invasive ventilation. There was no significant association between dTF and extubation success; OR 0.33 (95% CI; 0.06-1.86). Diaphragmatic atrophy was observed in 17/53 cases, in three of extubation failure occurred. Children in the extubation failure group were younger: 2.0 months (IQR 0.81-183.0) vs. 3.0 months (IQR 0.10-48.0); p = 0.045. At baseline, pre-extubation and post-extubation there was no significant correlation between age and BSA on the one hand and dTF, Tdi- insp and Tdi-exp on the other hand. The ICC representing the level of inter-rater reliability between the two examiners performing the ultrasounds was 0.994 (95% CI 0.970-0.999). The ICC of the inter-rater reliability between the raters in 36 paired assessments was 0.983 (95% CI 0.974-0.990). Conclusion: There was no significant association between thickening fraction of the diaphragm and extubation success in ventilated children.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA