Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
1.
Anal Chem ; 95(36): 13555-13565, 2023 09 12.
Artigo em Inglês | MEDLINE | ID: mdl-37650651

RESUMO

Intracellular lipid droplets (LDs) are dynamic, complex organelles involved in nearly all aspects of cellular metabolism. In situ characterization methods are primarily limited to fluorescence imaging, which yields limited chemical information, or Raman spectroscopy, which provides excellent chemical profiling but very low throughput. Here, we propose a new paradigm where locations of both large and small droplets are obtained automatically from high-resolution phase images and fed into a galvomirror-controlled Raman sampling arm to obtain the full spectrum of each LD efficiently. Using this phase-guided Raman sampling, we can characterize hundreds of LDs within a single cell in minutes and easily acquire more than 40,000 high-quality spectra. The data set revealed strong, cell line-dependent, cell-dependent, and individual droplet-dependent composition changes to various culture conditions. In particular, we revealed a strong competitive relationship between mono- and polyunsaturated fatty acids, where supplementation with one led to a relative decrease in the other.


Assuntos
Gotículas Lipídicas , Imagem Óptica , Linhagem Celular , Sorogrupo , Análise Espectral Raman
2.
Anal Chem ; 95(39): 14762-14769, 2023 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-37729474

RESUMO

Chemiluminescence (CL) has emerged as a critical tool for the sensing and quantification of various bioanalytes in virtually all clinical fields. However, the rapid nature of many CL reactions raises challenges for typical low-cost optical sensors such as cameras to achieve accurate and sensitive detection. Meanwhile, classic sensors such as photomultiplier tubes are highly sensitive but lack spatial multiplexing capabilities and are generally not suited for point-of-care applications outside a standard laboratory setting. To address this issue, in this paper, a miniaturized and versatile silicon-photomultiplier-based fiber-integrated CL device (SFCD) was designed for sensitive multiplex CL detection. The SFCD comprises a silicon photomultiplier array coupled to an array of high numerical aperture plastic optical fibers to achieve 16-plex detection. The optical fibers ensure efficient light collection while allowing the fixed detector to be mated with diverse sample geometries (e.g., circular or grid), simply by adjusting the fiber configuration. In a head-to-head comparison with a lens-based camera system featuring a cooled detector, the SFCD achieved a 14-fold improved limit of detection in both direct and enzyme-mediated CL reactions. The SFCD also features improved compactness and lower cost, as well as faster temporal resolution compared with camera-based systems while preserving spatial multiplexing and good environmental robustness. Thus, the SFCD has excellent potential for point-of-care biosensing applications.

3.
Analyst ; 148(19): 4710-4720, 2023 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-37622207

RESUMO

Raman hyperspectral imaging is an effective method for label-free imaging with chemical specificity, yet the weak signals and correspondingly long integration times have hindered its wide adoption as a routine analytical method. Recently, low resolution Raman imaging has been proposed to improve the spectral signal-to-noise ratio, which significantly improves the speed of Raman imaging. In this paper, low resolution Raman spectroscopy is combined with "context-aware" matrix completion, where regions of the sample that are not of interest are skipped, and the regions that are measured are under-sampled, then reconstructed with a low-rank constraint. Both simulations and experiment show that low-resolution Raman boosts the speed and image quality of the computationally-reconstructed Raman images, allowing deeper sub-sampling, reduced exposure time, and an overall >10-fold improvement in imaging speed, without sacrificing chemical specificity or spatial image quality. As the method utilizes traditional point-scan imaging, it retains full confocality and is "backwards-compatible" with pre-existing traditional Raman instruments, broadening the potential scope of Raman imaging applications.

4.
Analyst ; 148(12): 2809-2817, 2023 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-37219873

RESUMO

The weak signal strength of Raman imaging leads to long imaging times. To increase the speed of Raman imaging, line scanning and compressed Raman imaging methods have been proposed. Here we combine both line scanning and compressed sensing to further increase the speed. However, the direct combination leads to poor reconstruction results due to the missed coverage of the sample. To avoid this issue, "full-coverage" Compressed Line-scan Raman Imaging (FC-CLRI) is proposed, where line positions are random but constrained to measure each line position of the sample at least once. In proof-of-concept studies of polymer beads and yeast cells, FC-CLRI achieved reasonable image quality while making only 20-40% of the measurements of a fully-sampled line-scan image, achieving 640 µm2 FOV imaging in <2 min with 1.5 mW µm-2 laser power. Furthermore, we critically evaluate the CLRI method through comparison with simple downsampling, and have found that FC-CLRI preserves spatial resolution better while naïve downsampling provides an overall higher image quality for complex samples.

5.
J Opt Soc Am A Opt Image Sci Vis ; 40(6): 1155-1164, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37706768

RESUMO

During the past decade, spatial light interference microscopy (SLIM) has undergone rapid development, evidenced by its broadening applications in biology and medicine. However, the need for an expensive spatial light modulator (SLM) may limit its adoption, and the requirement for multiple images per plane limits its speed in volumetric imaging. Here we propose to address these issues by replacing the SLM with a mask fabricated from a low cost optical density (OD) filter, and recover high contrast images computationally rather than through phase-shifting. This is done using a specially constructed Wiener filter to recover the object scattering potential. A crucial part of the Wiener filter is estimating the arbitrary phase introduced by the OD filter. Our results demonstrate that not only were we able to estimate the OD filter's phase modulation in situ, but also the contrast of the reconstructed images is greatly improved. Comparisons with other related methods are also performed, with the conclusion that the combination of an inexpensive OD mask and modified Wiener filtering leads to results that are closest to the traditional SLIM setup. Thus, we have demonstrated the feasibility of a low cost, high speed SLIM system utilizing computational phase reconstruction, paving the way for wider adoption of high resolution phase microscopy.

6.
J Am Chem Soc ; 144(33): 15314-15323, 2022 08 24.
Artigo em Inglês | MEDLINE | ID: mdl-35969674

RESUMO

Small-molecule Raman probes for cellular imaging have attracted great attention owing to their sharp peaks that are sensitive to environmental changes. The small cross section of molecular Raman scattering limits dynamic cellular Raman imaging to expensive and complex coherent approaches that acquire single-channel images and lose hyperspectral Raman information. We introduce a new method, dynamic azo-enhanced Raman imaging (DAERI), to couple the new class of azo-enhanced Raman probes with a high-speed line-scan Raman imaging system. DAERI achieved high-resolution low-power imaging of fast cellular dynamics resolved at ∼270 nm along the confocal direction, 75 µW/µm2 and 3.5 s/frame. Based on the azo-enhanced Raman probes with characteristic signals 102-104 stronger than classic Raman labels, DAERI was not restricted to the cellular Raman-silent region as in prior work and enabled multiplex visualization of organelle motions and interactions. We anticipate DAERI to be a powerful tool for future studies in biophysics and cell biology.


Assuntos
Análise Espectral Raman , Análise Espectral Raman/métodos
7.
Anal Chem ; 94(31): 11000-11007, 2022 08 09.
Artigo em Inglês | MEDLINE | ID: mdl-35895976

RESUMO

Microscopic imaging and imaging flow cytometry have wide potential in point-of-care assays; however, their narrow depth of focus necessitates precise mechanical or fluidic focus control of a sample in order to acquire high-quality images that can be used for downstream analysis, increasing the cost and complexity of the imaging system. This complexity represents a barrier to miniaturization and translation of point-of-care assays based on microscopic imaging or imaging flow cytometry. To address this challenge, we present a simple drop-in phase mask with a physics-informed, circularly symmetric asphere phase profile that extends the depth of focus by >5-fold while largely preserving the image quality compared to other depth extending methods. We show that such a focus-extended system overcomes manufacturing tolerances in low-cost sample chambers, enlarges the useable field-of-view of low-cost objectives, and permits increased throughput and precision in flow imaging systems without the need for complex flow-focusing. As the image quality is preserved without the need for postacquisition image restoration, our solution is also highly appropriate for on-line applications such as cell sorting.


Assuntos
Microfluídica , Testes Imediatos , Separação Celular , Análise Custo-Benefício , Citometria de Fluxo/métodos , Sistemas Automatizados de Assistência Junto ao Leito
8.
Anal Chem ; 94(30): 10764-10772, 2022 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-35858837

RESUMO

Microfluidic paper-based analytical devices (µPADs) have attracted significant attention in the field of point-of-care (POC) diagnostics. However, the heterogeneous structure of the paper often impairs the limit of detection (LOD) for low-abundance targets when those targets are directly analyzed. One viable solution to bypass this limitation is to elevate the target concentration above the LOD on-site to reach a valid readout. Here, we developed a 3D µPADs preconcentrator (3D-µP2) to increase sample concentration by electrokinetic trapping and demonstrated its application in increasing the LOD of a downstream colorimetric assay. The three-dimensional (3D) structure of this device was composed of a loading pad, a vertical fluid path formed by stacked absorbent pads, and an ion-selective membrane of PEDOT:PSS. This novel design facilitates fast preconcentration, high capacity in sample processing, and easy target retrieval. The concentration of an exemplary target, a single-stranded DNA sequence, was increased up to 170-fold within 80 s. The LOD of the colorimetric assay to verify the DNA target was increased 3 orders of magnitude with a preconcentrated sample compared to the control. The device and its analysis equipment used in this study were all cheap and portable. Thus, the 3D-µP2 can be a powerful POC tool for sample pretreatment in resource-limited areas.


Assuntos
Técnicas Analíticas Microfluídicas , Microfluídica , Biomarcadores , Papel , RNA
9.
Anal Chem ; 94(41): 14232-14241, 2022 10 18.
Artigo em Inglês | MEDLINE | ID: mdl-36202399

RESUMO

Laser tweezers Raman spectroscopy enables multiplexed, quantitative chemical and morphological analysis of individual bionanoparticles such as drug-loaded nanoliposomes, yet it requires minutes-scale acquisition times per particle, leading to a lack of statistical power in typical small-sized data sets. The long acquisition times present a bottleneck not only in measurement time but also in the analytical throughput, as particle concentration (and thus throughput) must be kept low enough to avoid swarm measurement. The only effective way to improve this situation is to reduce the exposure time, which comes at the expense of increased noise. Here, we present a hybrid principal component analysis (PCA) denoising method, where a small number (∼30 spectra) of high signal-to-noise ratio (SNR) training data construct an effective principal component subspace into which low SNR test data are projected. Simulations and experiments prove the method outperforms traditional denoising methods such as the wavelet transform or traditional PCA. On experimental liposome samples, denoising accelerated data acquisition from 90 to 3 s, with an overall 4.5-fold improvement in particle throughput. The denoised data retained the ability to accurately determine complex morphochemical parameters such as lamellarity of individual nanoliposomes, as confirmed by comparison with cryo-EM imaging. We therefore show that hybrid PCA denoising is an efficient and effective tool for denoising spectral data sets with limited chemical variability and that the RR-NTA technique offers an ideal path for studying the multidimensional heterogeneity of nanoliposomes and other micro/nanoscale bioparticles.


Assuntos
Algoritmos , Lipossomos , Análise de Componente Principal , Razão Sinal-Ruído , Análise Espectral Raman
10.
Opt Express ; 30(6): 9505-9520, 2022 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-35299377

RESUMO

Panoramic and long-term observation of nanosized organelle dynamics and interactions with high spatiotemporal resolution still hold great challenge for current imaging platforms. In this study, we propose a live-organelle imaging platform, where a flat-fielding quantitative phase contrast microscope (FF-QPCM) visualizes all the membrane-bound subcellular organelles, and an intermittent fluorescence channel assists in specific organelle identification. FF-QPCM features a high spatiotemporal resolution of 245 nm and 250 Hz and strong immunity against external disturbance. Thus, we could investigate several important dynamic processes of intracellular organelles from direct perspectives, including chromosome duplication in mitosis, mitochondrial fusion and fission, filaments, and vesicles' morphologies in apoptosis. Of note, we have captured, for the first time, a new type of mitochondrial fission (entitled mitochondrial disintegration), the generation and fusion process of vesicle-like organelles, as well as the mitochondrial vacuolization during necrosis. All these results bring us new insights into spatiotemporal dynamics and interactions among organelles, and hence aid us in understanding the real behaviors and functional implications of the organelles in cellular activities.


Assuntos
Mitocôndrias , Organelas , Microscopia , Microscopia de Contraste de Fase
11.
Opt Lett ; 47(22): 5949-5952, 2022 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-37219144

RESUMO

Traditional line-scan Raman imaging features a rapid imaging speed while preserving complete spectral information, yet has diffraction-limited resolution. Sinusoidally structured line excitation can yield an improvement in the lateral resolution of the Raman image along the line's direction. However, given the need for the line and spectrometer slit to be aligned, the resolution in the perpendicular direction remains diffraction limited. To overcome this, we present here a galvo-modulated structured line imaging system, where a system of three galvos can arbitrarily orient the structured line on the sample plane, while keeping the beam aligned to the spectrometer slit in the detection plane. Thus, a two-fold isotropic improvement in the lateral resolution fold is possible. We demonstrate the feasibility using mixtures of microspheres as chemical and size standards. The results prove an improvement in the lateral resolution of 1.8-fold (limited by line contrast at higher frequencies), while preserving complete spectral information of the sample.

12.
Analyst ; 147(20): 4607-4615, 2022 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-36124554

RESUMO

With the advent of hyperspectral Raman imaging technology, especially the rapid and high-resolution imaging schemes, datasets with thousands to millions of spectra are now commonplace. Standard preprocessing and regression methods such as least squares approaches are time consuming and require input from highly trained operators. Here we propose a solution to this analytic bottleneck through a convolutional neural network trained fully on synthetic data and then applied to experimental measurements, including cases where complete spectral information is missing (i.e. an underdetermined model). An advantage of the model is that it combines background correction and regression into a single step, and does not require user-selected parameters. We compare our results with traditional least squares methods, including the popular asymmetric least squares (AsLS) approach. Our results demonstrate that the proposed CNN model boasts less sensitivity to parameter selection, and with a rapid processing speed, with performance equal to or better than comparison methods. The performance is validated on synthetic spectral mixtures, as well as experimentally measured single-vesicle liposome data.


Assuntos
Lipossomos , Redes Neurais de Computação
13.
J Opt Soc Am A Opt Image Sci Vis ; 39(2): 287-296, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-35200967

RESUMO

As one of the most sensitive quantitative phase microscopy techniques, spatial light interference microscopy (SLIM) has undergone rapid development in the past decade and has seen wide application in both basic science and clinical studies. However, as with any other traditional microscope, the axial resolution is the worst among the three dimensions. This leads to lower contrast in the thicker regions of cell samples. Another common foe in the phase contrast image is the halo artifact, which can block underlying structures, in particular when high resolution is desired. Current solutions focus on either halo removal or contrast enhancement alone, and thus need two processing steps to create both high contrast and halo-free phase images. Further, raw images often suffer from artifacts that are both bright and slowly varying, dubbed here as cloud-like artifacts. After deconvolution, these cloud-like artifacts often dominate the image and obscure high-frequency information, which is typically of greatest interest. In this paper, we first analyzed the unique characteristics of the phase transfer function associated with SLIM to find the root of the cloud-like artifacts and halo artifacts. Then we designed a two-edge apodized deconvolution scheme as a counter measure. We show that even with a simple Wiener filter, the two-edge apodization (TEA) can effectively improve the contrast while suppressing the halo and cloud-like artifacts. Our algorithm, named TEA-Weiner, is non-iterative and thus can be implemented in real time. For low-contrast structures inside the cell such as the endoplasmic reticulum (ER), where ringing artifacts are more likely, we show that two-edge apodization can be combined with additional constraints such as total variation so that their contrast can be enhanced simultaneously with other bright structures inside the cell. Comparing our method with other state-of-the-art algorithms, our method has two advantages: First, deconvolution and halo removal are accomplished simultaneously; second, the image quality is highest using TEA-Weiner filtering.

14.
Anal Chem ; 93(47): 15659-15666, 2021 11 30.
Artigo em Inglês | MEDLINE | ID: mdl-34779624

RESUMO

Due to the fundamental mechanism of vibrational state transitions for chemical bonds, the spectra of Raman scattering are narrow-banded and photostable signals capable of probing specific reactions. In the case of protonation/deprotonation reactions, certain chemical bonds are broken and new bonds are formed. Based on the changes of the vibrational modes for the corresponding bonds, fingerprint analysis of multiple Raman bands may allow for the in situ visualization of proton distribution in live cells. However, Raman scattering faces the well-known challenge of low sensitivity. To perform the vibrational fingerprint analysis of Raman scattering by overcoming this challenge, we developed an azo-based resonance Raman pH probe. It was an azobenzene-featured small molecule responsive to protons with the inherent Raman signal ∼104-fold more intense than that of the conventional alkyne-type Raman reporter 5-ethynyl-2'-deoxyuridine. Through the substitution of the electron-donating and -withdrawing entities to the azobenzene group, the effect of resonance Raman scattering and fluorescence quenching was obtained. This effect resulted in a significant Raman enhancement factor of ∼103 compared to the counterpart molecules without the molecular design. Based on the enhanced Raman sensitivity of the azo-based resonance Raman pH probe, the identification of vibrational fingerprint changes at the azo group was achieved during the protonation/deprotonation reactions, and the vibrational fingerprint analysis resolved a pH difference of less than 0.2 unit. The method enabled sensitive hyperspectral cell imaging that clearly visualized the change of proton distribution in autophagic cells.


Assuntos
Prótons , Análise Espectral Raman , Lisossomos , Microscopia , Vibração
15.
EMBO Rep ; 20(10): e48115, 2019 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-31379107

RESUMO

Lin28 plays an important role in promoting tumor development, whereas its exact functions and underlying mechanisms are largely unknown. Here, we show that both human homologs of Lin28 accelerate de novo fatty acid synthesis and promote the conversion from saturated to unsaturated fatty acids via the regulation of SREBP-1. By directly binding to the mRNAs of both SREBP-1 and SCAP, Lin28A/B enhance the translation and maturation of SREBP-1, and protect cancer cells from lipotoxicity. Lin28A/B-stimulated tumor growth is abrogated by SREBP-1 inhibition and by the impairment of the RNA binding properties of Lin28A/B, respectively. Collectively, our findings uncover that post-transcriptional regulation by Lin28A/B enhances de novo fatty acid synthesis and metabolic conversion of saturated and unsaturated fatty acids via SREBP-1, which is critical for cancer progression.


Assuntos
Progressão da Doença , Ácidos Graxos/biossíntese , Neoplasias Hepáticas/metabolismo , Neoplasias Hepáticas/patologia , Proteínas de Ligação a RNA/metabolismo , Proteína de Ligação a Elemento Regulador de Esterol 1/metabolismo , Linhagem Celular Tumoral , Proliferação de Células , Citoproteção , Estresse do Retículo Endoplasmático , Humanos , Peptídeos e Proteínas de Sinalização Intracelular/genética , Peptídeos e Proteínas de Sinalização Intracelular/metabolismo , Proteínas de Membrana/genética , Proteínas de Membrana/metabolismo , Modelos Biológicos , Ligação Proteica , Biossíntese de Proteínas , RNA Mensageiro/genética , RNA Mensageiro/metabolismo
16.
Analyst ; 146(7): 2348-2357, 2021 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-33624650

RESUMO

Raman hyperspectral imaging is a powerful method to obtain detailed chemical information about a wide variety of organic and inorganic samples noninvasively and without labels. However, due to the weak, nonresonant nature of spontaneous Raman scattering, acquiring a Raman imaging dataset is time-consuming and inefficient. In this paper we utilize a compressive imaging strategy coupled with a context-aware image prior to improve Raman imaging speed by 5- to 10-fold compared to classic point-scanning Raman imaging, while maintaining the traditional benefits of point scanning imaging, such as isotropic resolution and confocality. With faster data acquisition, large datasets can be acquired in reasonable timescales, leading to more reliable downstream analysis. On standard samples, context-aware Raman compressive imaging (CARCI) was able to reduce the number of measurements by ∼85% while maintaining high image quality (SSIM >0.85). Using CARCI, we obtained a large dataset of chemical images of fission yeast cells, showing that by collecting 5-fold more cells in a given experiment time, we were able to get more accurate chemical images, identification of rare cells, and improved biochemical modeling. For example, applying VCA to nearly 100 cells' data together, cellular organelles were resolved that were not faithfully reconstructed by a single cell's dataset.

17.
Anal Bioanal Chem ; 413(20): 5025-5035, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34170346

RESUMO

While many clinical laboratory tests are now highly automated, body fluid cell counting, particularly in low-cellularity samples such as cerebral spinal fluid (CSF), is often performed manually. Here, we report a simple, cost-effective method to obtain white and red blood cell counts from human body fluids such as CSF. The method consists of a compact, automated, and low-cost fluorescence microscope system, coupled to a sample chamber containing all of the necessary reagents in dry form to stain and prepare the sample. Sample focus and scanning are handled automatically, and the acquired multimodal images are automatically analyzed to extract cell counts. Comparison with manual counting on over 200 clinical samples shows excellent agreement. As the system counts a substantially larger image region than a standard manual cell count, we find our sensitivity to extremely low cellularity samples to potentially be higher than the manual gold standard, evidenced by our system recording images of cells in samples whose cell count was registered as "0" by a trained user. Thus, our system holds promise for routine, automated, and sensitive analysis of body fluids whose cellularity extends across a wide dynamic range.


Assuntos
Automação/métodos , Líquidos Corporais/citologia , Contagem de Células/instrumentação , Contagem de Células/métodos , Humanos
18.
Am J Emerg Med ; 43: 217-223, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-32291164

RESUMO

INTRODUCTION: The Advanced Cardiac Life Support (ACLS) Clinical Decision Display System (CDDS) is a novel application designed to optimize team organization and facilitate decision-making during ACLS resuscitations. We hypothesized that resuscitation teams would more consistently adhere to ACLS guideline time intervals in simulated resuscitation scenarios with the CDDS compared to without. METHODS: We conducted a simulation-based, non-blinded, randomized, crossover-design study with resuscitation teams comprised of Emergency Medicine physicians, registered nurses, critical care technicians, and paramedics. Each team performed 4 ACLS scenarios in randomized sequences, half with the CDDS and half without. We analyzed the resuscitations and recorded the times of interventions that have defined intervals by ACLS: rhythm checks, epinephrine administration, and shock delivery. In addition, we surveyed each resuscitation team regarding their experience using the CDDS. RESULTS: On average, teams performed rhythm checks 4.9 s closer to ACLS guidelines with the CDDS (p = 0.0358). Teams were also more consistent; on average, teams reduced the variation of time between consecutive doses of epinephrine by 45% (p = 0.0001) and defibrillation by 47% (p < 0.0001). Ninety-eight percent of participants indicated they would use the CDDS if available in real cardiac arrests. CONCLUSIONS: This study demonstrates that the CDDS improves the accuracy and precision of timed ACLS interventions in a simulated setting. Resuscitation teams were strongly in favor of utilizing the CDDS in clinical practice. Further investigations of the introduction of the platform into real time clinical environments will be needed to assess true efficacy and patient outcomes.


Assuntos
Suporte Vital Cardíaco Avançado/normas , Sistemas de Apoio a Decisões Clínicas , Medicina de Emergência/normas , Fidelidade a Diretrizes , Estudos Cross-Over , Parada Cardíaca/terapia , Humanos
19.
Anal Chem ; 92(7): 5585-5594, 2020 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-32162516

RESUMO

Biological nanoparticles are important targets of study, yet their small size and tendency to aggregate makes their heterogeneity difficult to profile on a truly single-particle basis. Here we present a label-free system called 'Raman-enabled nanoparticle trapping analysis' (R-NTA) that optically traps individual nanoparticles, records Raman spectra and tracks particle motion to identify chemical composition, size, and refractive index. R-NTA has the unique capacity to characterize aggregation status and absolute chemical concentration at the single-particle level. We validate the method on NIST standards and liposomes, demonstrating that R-NTA can accurately characterize size and chemical heterogeneity, including determining combined morpho-chemical properties such as the number of lamellae in individual liposomes. Applied to extracellular vesicles (EVs), we find distinct differences between EVs from cancerous and noncancerous cells, and that knockdown of the TRPP2 ion channel, which is pathologically highly expressed in laryngeal cancer cells, leads the EVs to more closely resemble EVs from normal epithelial cells. Intriguingly, the differences in EV content are found in small subpopulations of EVs, highlighting the importance of single-particle measurements. These experiments demonstrate the power of the R-NTA system to measure and characterize the morpho-chemical heterogeneity of bionanoparticles.


Assuntos
Vesículas Extracelulares/química , Nanopartículas/química , Linhagem Celular Tumoral , Humanos , Tamanho da Partícula , Análise Espectral Raman
20.
Analyst ; 145(20): 6607-6616, 2020 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-32789319

RESUMO

The majority of problems in analytical Raman spectroscopy are mathematically over-determined, where many more spectral variables are measured than analytic outputs (such as chemical concentrations) are calculated. Thus, to improve spectral throughput and simplify system design, some researchers have explored the use of low resolution Raman systems for cell or tissue classification, achieving accuracy independent of spectral resolution. However, the tradeoffs inherent in this approach have not been systematically studied. Here, we theoretically and experimentally explore the relationship between spectral resolution and analytical error. We show that decreased spectral resolution leads to spectral signal-to-noise ratio and therefore more reliable results and lower limits of detection for equivalent integration times in blind unmixing of hyperspectral images. Our theoretical analysis demonstrates that the primary benefit of low resolution Raman spectroscopy is in overcoming detector noise (such as thermal or electronic noise). Therefore, the benefits are most pronounced when utilizing lower-grade, uncooled detectors. Therefore, using a low-cost CMOS camera we experimentally demonstrate the ability of low resolution Raman spectroscopy to achieve substantially improved imaging performance compared to fully-resolved Raman spectral imaging, paving the way for cost-effective, pervasive Raman spectroscopy.


Assuntos
Imageamento Hiperespectral , Análise Espectral Raman , Diagnóstico por Imagem , Limite de Detecção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA