1.
Radiology ; 265(2): 627-37, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23012465

RESUMO

PURPOSE: To evaluate the accuracy of the size and location of the ablation zone produced by volumetric magnetic resonance (MR) imaging-guided high-intensity focused ultrasound ablation of uterine fibroids on the basis of MR thermometric analysis and to assess the effects of a feedback control technique. MATERIALS AND METHODS: This prospective study was approved by the institutional review board, and written informed consent was obtained. Thirty-three women with 38 uterine fibroids were treated with an MR imaging-guided high-intensity focused ultrasound system capable of volumetric feedback ablation. Size (diameter times length) and location (three-dimensional displacements) of each ablation zone induced by 527 sonications (with [n=471] and without [n=56] feedback) were analyzed according to the thermal dose obtained with MR thermometry. Prospectively defined acceptance ranges of targeting accuracy were ±5 mm in left-right (LR) and craniocaudal (CC) directions and ±12 mm in anteroposterior (AP) direction. Effects of feedback control in 8- and 12-mm treatment cells were evaluated by using a mixed model with repeated observations within patients. RESULTS: Overall mean sizes of ablation zones produced by 4-, 8-, 12-, and 16-mm treatment cells (with and without feedback) were 4.6 mm±1.4 (standard deviation)×4.4 mm±4.8 (n=13), 8.9 mm±1.9×20.2 mm±6.5 (n=248), 13.0 mm±1.2×29.1 mm±5.6 (n=234), and 18.1 mm±1.4×38.2 mm±7.6 (n=32), respectively. Targeting accuracy values (displacements in absolute values) were 0.9 mm±0.7, 1.2 mm±0.9, and 2.8 mm±2.2 in LR, CC, and AP directions, respectively. Of 527 sonications, 99.8% (526 of 527) were within acceptance ranges. Feedback control had no statistically significant effect on targeting accuracy or ablation zone size. However, variations in ablation zone size were smaller in the feedback control group. CONCLUSION: Sonication accuracy of volumetric MR imaging-guided high-intensity focused ultrasound ablation of uterine fibroids appears clinically acceptable and may be further improved by feedback control to produce more consistent ablation zones.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Leiomioma/cirurgia , Imageamento por Ressonância Magnética/métodos , Termografia/métodos , Neoplasias Uterinas/cirurgia , Adulto , Feminino , Humanos , Imageamento Tridimensional/métodos , Leiomioma/diagnóstico , Pessoa de Meia-Idade , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Cirurgia Assistida por Computador/métodos , Resultado do Tratamento , Neoplasias Uterinas/diagnóstico
2.
World J Radiol ; 7(12): 521-30, 2015 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-26753067

RESUMO

AIM: To evaluate the feasibility of using therapeutic ultrasound as an alternative treatment option for organ-confined prostate cancer. METHODS: In this study, a trans-urethral therapeutic ultrasound applicator in combination with 3T magnetic resonance imaging (MRI) guidance was used for real-time multi-planar MRI-based temperature monitoring and temperature feedback control of prostatic tissue thermal ablation in vivo. We evaluated the feasibility and safety of MRI-guided trans-urethral ultrasound to effectively and accurately ablate prostate tissue while minimizing the damage to surrounding tissues in eight canine prostates. MRI was used to plan sonications, monitor temperature changes during therapy, and to evaluate treatment outcome. Real-time temperature and thermal dose maps were calculated using the proton resonance frequency shift technique and were displayed as two-dimensional color-coded overlays on top of the anatomical images. After ultrasound treatment, an evaluation of the integrity of cavernosal nerves was performed during prostatectomy with a nerve stimulator that measured tumescence response quantitatively and indicated intact cavernous nerve functionality. Planned sonication volumes were visually correlated to MRI ablation volumes and corresponding histo-pathological sections after prostatectomy. RESULTS: A total of 16 sonications were performed in 8 canines. MR images acquired before ultrasound treatment were used to localize the prostate and to prescribe sonication targets in all canines. Temperature elevations corresponded within 1 degree of the targeted sonication angle, as well as with the width and length of the active transducer elements. The ultrasound treatment procedures were automatically interrupted when the temperature in the target zone reached 56 °C. In all canines erectile responses were evaluated with a cavernous nerve stimulator post-treatment and showed a tumescence response after stimulation with an electric current. These results indicated intact cavernous nerve functionality. In all specimens, regions of thermal ablation were limited to areas within the prostate capsule and no damage was observed in periprostatic tissues. Additionally, a visual analysis of the ablation zones on contrast-enhanced MR images acquired post ultrasound treatment correlated excellent with the ablation zones on thermal dose maps. All of the ablation zones received a consensus score of 3 (excellent) for the location and size of the correlation between the histologic ablation zone and MRI based ablation zone. During the prostatectomy and histologic examination, no damage was noted in the bladder or rectum. CONCLUSION: Trans-urethral ultrasound treatment of the prostate with MRI guidance has potential to safely, reliably, and accurately ablate prostatic regions, while minimizing the morbidities associated with conventional whole-gland resection or therapy.

3.
Phys Med Biol ; 57(9): 2653-66, 2012 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-22504096

RESUMO

This pilot study investigated the feasibility of using MRI based on BOLD (blood-oxygen-level-dependent) contrast to detect physiological effects of locally induced hyperthermia in a rodent tumor model. Nude mice bearing AT6.1 rodent prostate tumors inoculated in the hind leg were imaged using a 9.4 T scanner using a multi-gradient echo pulse sequence to acquire high spectral and spatial resolution (HiSS) data. Temperature increases of approximately 6 °C were produced in tumor tissue using fiber-optic-guided light from a 250 W halogen lamp. HiSS data were acquired over three slices through the tumor and leg both prior to and during heating. Water spectra were produced from these datasets for each voxel at each time point. Time-dependent changes in water resonance peak width were measured during 15 min of localized tumor heating. The results demonstrated that hyperthermia produced both significant increases and decreases in water resonance peak width. Average decreases in peak width were significantly larger in the tumor rim than in normal muscle (p = 0.04). The effect of hyperthermia in tumor was spatially heterogeneous, i.e. the standard deviation of the change in peak width was significantly larger in the tumor rim than in normal muscle (p = 0.005). Therefore, mild hyperthermia produces spatially heterogeneous changes in water peak width in both tumor and muscle. This may reflect heterogeneous effects of hyperthermia on local oxygenation. The peak width changes in tumor and muscle were significantly different, perhaps due to abnormal tumor vasculature and metabolism. Response to hyperthermia measured by MRI may be useful for identifying and/or characterizing suspicious lesions as well as guiding the development of new hyperthermia protocols.


Assuntos
Hipertermia Induzida , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/terapia , Animais , Masculino , Camundongos , Oxigênio/sangue , Projetos Piloto , Neoplasias da Próstata/sangue , Neoplasias da Próstata/patologia
4.
Invest Radiol ; 46(10): 639-47, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21654495

RESUMO

OBJECTIVES: : To evaluate dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) parameters in the prediction of the immediate therapeutic response of MR-guided high-intensity focused ultrasound (HIFU) therapy in the treatment of symptomatic uterine fibroids MATERIALS AND METHODS: : Institutional review board approved this study, and informed consent was obtained from all participants. A total of 10 symptomatic uterine fibroids (diameter: mean, 8.9 cm; range, 4.7-12 cm) in 10 female patients (mean age, 42.2 years) were treated with MR-HIFU therapy using the volumetric ablation technique. DCE-MRI and conventional contrast-enhanced MRI were obtained as a baseline and as an immediate follow-up study, respectively. After regions of interest of each treatment cell were properly registered to both MRI studies, DCE-MRI parameters (K, ve, vp) and operator-controllable therapy parameters (power, treatment cell size, sonication depth) were investigated on a cell-by-cell basis to reflect tissue inhomogeneity. Two types of ablation efficacy indices (volume of 240 equivalent minutes at 43°C/treatment-cell volume, nonperfused volume/treatment-cell volume) were then correlated with those parameters using multiple linear regression analysis to determine which factors were significant predictors for ablation efficacy. RESULTS: : We used 293 treatment cells (4 mm, n = 12; 8 mm, n = 115; 12 mm, n = 149; 16 mm, n = 17), and all of them were analyzable. Ablation efficacies were 1.06 ± 0.58 and 0.67 ± 0.39. K (B = -12.035, P < 0.001 and B = -11.516, P < 0.001, respectively) among DCE-MRI parameters and acoustic power (B = 0.008, P < 0.001; B = 0.010, P < 0.001, respectively) among therapy parameters were revealed to be independently significant predictors for both types of ablation efficacy. CONCLUSIONS: : A higher K value at baseline DCE-MRI suggested a poor ablation efficacy of MR-HIFU therapy for symptomatic uterine fibroids.


Assuntos
Meios de Contraste , Compostos Heterocíclicos , Ablação por Ultrassom Focalizado de Alta Intensidade , Leiomioma/terapia , Imagem por Ressonância Magnética Intervencionista/métodos , Imageamento por Ressonância Magnética/métodos , Compostos Organometálicos , Neoplasias Uterinas/terapia , Adulto , Feminino , Humanos , Análise dos Mínimos Quadrados , Leiomioma/patologia , Modelos Lineares , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Resultado do Tratamento , Neoplasias Uterinas/patologia
5.
IEEE Trans Biomed Eng ; 57(1): 103-13, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19846364

RESUMO

Volumetric high-intensity focused ultrasound (HIFU) guided by multiplane magnetic resonance (MR) thermometry has been shown to be a safe and efficient method to thermally ablate large tissue volumes. However, the induced temperature rise and thermal lesions show significant variability, depending on exposure parameters, such as power and timing, as well as unknown tissue parameters. In this study, a simple and robust feedback-control method that relies on rapid MR thermometry to control the HIFU exposure during heating is introduced. The binary feedback algorithm adjusts the durations of the concentric ablation circles within the target volume to reach an optimal temperature. The efficacy of the binary feedback control was evaluated by performing 90 ablations in vivo and comparing the results with simulations. Feedback control of the sonications improved the reproducibility of the induced lesion size. The standard deviation of the diameter was reduced by factors of 1.9, 7.2, 5.0, and 3.4 for 4-, 8-, 12-, and 16-mm lesions, respectively. Energy efficiency was also improved, as the binary feedback method required less energy to create the desired lesion. These results show that binary feedback improves the quality of volumetric ablation by consistently producing thermal lesions of expected size while reducing the required energy as well.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Processamento de Sinais Assistido por Computador , Algoritmos , Animais , Simulação por Computador , Retroalimentação , Masculino , Suínos