Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 92
Filtrar
1.
J Arthroplasty ; 2024 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-38677343

RESUMO

BACKGROUND: Periprosthetic joint infection (PJI) treatment has high failure rates even after 2-stage revision. Risk factors for treatment failure (TF) after staged revision for PJI are not well defined, nor is it well established how they correlate with the risks of developing an index PJI. Identifying modifiable risk factors may allow preoperative optimization, while identifying nonmodifiable risk factors can influence surgical options or advise against further surgery. We performed a systematic review and meta-analysis to better define predictors of TF in 2-stage revision for PJI. METHODS: The PubMed, Embase, and Scopus databases were searched from their inception in December 1976 to April 15, 2023. Studies comparing patient-related variables between patients successfully treated who had 2-staged revision total hip arthroplasty (THA) and patients with persistent infections were included. Studies were screened, and 2 independent reviewers extracted data, while a third resolved discrepancies. Meta-analysis was performed on these data. There were 10,052 unique studies screened, and 21 studies met the inclusion criteria for data extraction. RESULTS: There was good-quality evidence that obesity, liver cirrhosis, and previous failed revisions for PJI are nonmodifiable risk factors, while intravenous drug use (IVDU) and smoking are modifiable risk factors for TF after 2-stage revision for hip PJI. Reoperation between revision stages was also significantly associated with an increased risk of TF. Interestingly, other risk factors for an index PJI including male gender, American Society of Anesthesiology score, diabetes mellitus, and inflammatory arthropathy did not predict TF. Evidence on Charlson Comorbidity Index was limited. CONCLUSIONS: Patients with a smoking history, obesity, IVDU, previous failed revision for PJI, reoperation between stages, and liver cirrhosis are more likely to experience TF after 2-stage revision THA for PJI. Modifiable risk factors include smoking and IVDU and these patients should be referred to services for cessation as early as possible before 2-stage revision THA.

2.
Osteoarthritis Cartilage ; 31(9): 1224-1233, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37178862

RESUMO

OBJECTIVE: It is unclear if different factors influence osteoarthritis (OA) progression and degenerative changes characterising OA disease in hip and knee. We investigated the difference between hip OA and knee OA at the subchondral bone (SCB) tissue and cellular level, relative to the degree of cartilage degeneration. DESIGN: Bone samples were collected from 11 patients (aged 70.4 ± 10.7years) undergoing knee arthroplasty and 8 patients (aged 62.3 ± 13.4years) undergoing hip arthroplasty surgery. Trabecular bone microstructure, osteocyte-lacunar network, and bone matrix vascularity were evaluated using synchrotron micro-CT imaging. Additionally, osteocyte density, viability, and connectivity were determined histologically. RESULTS: The associations between severe cartilage degeneration and increase of bone volume fraction (%) [- 8.7, 95% CI (-14.1, -3.4)], trabecular number (#/mm) [- 1.5, 95% CI (-0.8, -2.3)], osteocyte lacunar density (#/mm3) [4714.9; 95% CI (2079.1, 7350.6)] and decrease of trabecular separation (mm) [- 0.07, 95% CI (0.02, 0.1)] were found in both knee and hip OA. When compared to knee OA, hip OA was characterised by larger (µm3) but less spheric osteocyte lacunae [47.3; 95% CI (11.2, 83.4), - 0.04; 95% CI (-0.06, -0.02), respectively], lower vascular canal density (#/mm3) [- 22.8; 95% CI (-35.4, -10.3)], lower osteocyte cell density (#/mm2) [- 84.2; 95% CI (-102.5, -67.4)], and less senescent (#/mm2) but more apoptotic osteocytes (%) [- 2.4; 95% CI (-3.6, -1.2), 24.9; 95% CI (17.7, 32.1)], respectively. CONCLUSION: SCB from hip OA and knee OA exhibits different characteristics at the tissue and cellular levels, suggesting different mechanisms of OA progression in different joints.


Assuntos
Cartilagem Articular , Osteoartrite do Quadril , Osteoartrite do Joelho , Humanos , Osteoartrite do Quadril/diagnóstico por imagem , Osteoartrite do Quadril/patologia , Osso Esponjoso/diagnóstico por imagem , Osso Esponjoso/patologia , Síncrotrons , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/patologia , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/patologia , Microtomografia por Raio-X/métodos , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/patologia
3.
Acta Orthop ; 94: 626-634, 2023 12 29.
Artigo em Inglês | MEDLINE | ID: mdl-38157007

RESUMO

BACKGROUND AND PURPOSE: We conducted a systematic review and meta-analysis of RSA studies to investigate the early and long-term migration patterns of acetabular cups and the influence of implant factors on cup migration over time. METHODS: We performed a systematic search of PubMed, Embase, and Scopus databases to identify all RSA studies of cup migration following primary total hip replacement (THR). Proximal migration at 3 and 6 months, 1, 2, 5, and 10 years were considered for analysis. Implant factors investigated included fixation type, head size, bearing surface, uncemented coating design, and the decade of RSA introduction. RESULTS: 47 studies reported the proximal migration of 83 cohorts (2,328 cups). Besides 1 threaded cup design, no implant factor investigated was found to significantly influence proximal migration. The mean pooled 2-year proximal migration of cemented cups (0.14 mm, 95% confidence interval [CI] 0.08-0.20) was not significantly different from uncemented cups (0.12 mm, CI 0.04-0.19). The mean pooled proximal migration at 6 months was 0.11 mm (CI 0.06-0.16) and there was no significant increase between 6 months and 2 years (0.015 mm, CI 0.000-0.030). 27 of 75 cohorts (36%) reported mean proximal migration greater than 0.2 mm at 2 years, which has previously been identified as a predictor of implants at risk of long-term loosening. CONCLUSION: Our meta-analysis demonstrated that the majority of cup migration occurs within the first 6 months. With one exception, no implant factors influenced the 2-year proximal migration of acetabular cups. 36% of studies with 2-year migration were considered at risk of long-term loosening. Further investigation and comparison against long-term survivorship data would validate 6-month and/or 1-year proximal migration measurements as an earlier predictor of long-term loosening than the current 2-year threshold.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Prótese de Quadril/efeitos adversos , Seguimentos , Artroplastia de Quadril/efeitos adversos , Acetábulo/cirurgia , Reoperação , Falha de Prótese , Desenho de Prótese
4.
Calcif Tissue Int ; 111(4): 430-444, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35618777

RESUMO

Osteopetrosis is a heterogeneous group of rare hereditary diseases characterized by increased bone mass of poor quality. Autosomal-dominant osteopetrosis type II (ADOII) is most often caused by mutation of the CLCN7 gene leading to impaired bone resorption. Autosomal recessive osteopetrosis (ARO) is a more severe form and is frequently accompanied by additional morbidities. We report an adult male presenting with classical clinical and radiological features of ADOII. Genetic analyses showed no amino-acid-converting mutation in CLCN7 but an apparent haploinsufficiency and suppression of CLCN7 mRNA levels in peripheral blood mononuclear cells. Next generation sequencing revealed low-frequency intronic homozygous variations in CLCN7, suggesting recessive inheritance. In silico analysis of an intronic duplication c.595-120_595-86dup revealed additional binding sites for Serine- and Arginine-rich Splicing Factors (SRSF), which is predicted to impair CLCN7 expression. Quantitative backscattered electron imaging and histomorphometric analyses revealed bone tissue and material abnormalities. Giant osteoclasts were present and additionally to lamellar bone, and abundant woven bone and mineralized cartilage were observed, together with increased frequency and thickness of cement lines. Bone mineralization density distribution (BMDD) analysis revealed markedly increased average mineral content of the dense bone (CaMean T-score + 10.1) and frequency of bone with highest mineral content (CaHigh T-score + 19.6), suggesting continued mineral accumulation and lack of bone remodelling. Osteocyte lacunae sections (OLS) characteristics were unremarkable except for an unusually circular shape. Together, our findings suggest that the reduced expression of CLCN7 mRNA in osteoclasts, and possibly also osteocytes, causes poorly remodelled bone with abnormal bone matrix with high mineral content. This together with the lack of adequate bone repair mechanisms makes the material brittle and prone to fracture. While the skeletal phenotype and medical history were suggestive of ADOII, genetic analysis revealed that this is a possible mild case of ARO due to deep intronic mutation.


Assuntos
Canais de Cloreto , Osteopetrose , Canais de Cloreto/genética , Homozigoto , Humanos , Leucócitos Mononucleares/metabolismo , Masculino , Mutação , Osteopetrose/diagnóstico , Osteopetrose/genética , Osteopetrose/metabolismo , Fenótipo , RNA Mensageiro
5.
J Arthroplasty ; 35(10): 2931-2937, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32593487

RESUMO

BACKGROUND: It is proposed that highly porous coatings on acetabular components, such as a porous tantalum coating, provide adequate fixation without ancillary screw fixation in primary total hip arthroplasty (THA). However, tantalum acetabular components have been associated with higher rates of revision than other uncemented components in national registries. The aim of this randomized controlled trial is to determine whether the early migration of a solid-backed tantalum acetabular component was no greater than that of a titanium acetabular component with ancillary screw fixation that has proven good clinical results. METHODS: Sixty-six patients aged 40 to 64 years, with osteoarthritis and Charnley grade A or B activity grade and who underwent primary THA, were recruited into the trial. Patients were randomized intraoperatively to receive either the tantalum or titanium acetabular component. All patients received the same cemented polished tapered femoral stem, 28-mm cobalt-chromium femoral head, and highly cross-linked polyethylene liner. Acetabular component migration was measured using radiostereometric analysis at 4-6 days postoperatively and at 6 weeks, 3 months, 1 and 2 years following THA. RESULTS: The mean proximal migration at 2 years for the tantalum cohort was 0.17 mm (95% confidence interval, 0.09-0.24) which was no greater than that of the titanium cohort which was 0.19 mm (0.07-0.32). Harris hip scores and functional activity scores were similar between groups. CONCLUSION: These results demonstrate that early stability can be achieved without ancillary screw fixation through the use of a highly porous high friction coating on a solid-backed modular acetabular component. LEVEL OF EVIDENCE: Level I.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Acetábulo/cirurgia , Adulto , Parafusos Ósseos , Seguimentos , Humanos , Pessoa de Meia-Idade , Porosidade , Desenho de Prótese , Falha de Prótese , Reoperação , Tantálio , Titânio
6.
Surg Radiol Anat ; 42(6): 661-665, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31781923

RESUMO

PURPOSE: To quantify the prevalence of complete tibial insertion of the biceps femoris tendon in patients presenting for knee MRI scans. METHODS: Knee MRI scans over a 4-year period (2014-2018) were accessed at a tertiary referral centre and community-based private practice. A total of 433 scans were reviewed. 30 scans were excluded from the study due to repeat imaging or incomplete coverage of the biceps femoris tendon insertion. Appearances of the distal biceps tendon bony insertion were scrutinized on the remaining 403 scans. Each biceps femoris tendon insertion was classified into one of the four categories-complete fibular insertion, predominant fibular insertion, predominant tibial insertion and complete tibial insertion. RESULTS: Out of the final 403 scans included in the study, five cases of complete tibial insertion of the biceps femoris tendon were identified (just over 1% of the total population). 42 cases were identified as having predominant tibial insertion (10% of the total population). 113 cases had predominantly fibular insertion and 243 cases had complete fibular insertion. CONCLUSION: Complete anomalous insertion of the biceps femoris tendon on the anterolateral tibia is an uncommon entity. Such an attachment is found in approximately 1% of patients presenting for MRI evaluation of the knee.


Assuntos
Variação Anatômica , Tendões dos Músculos Isquiotibiais/anormalidades , Articulação do Joelho/anormalidades , Tíbia/anormalidades , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Tendões dos Músculos Isquiotibiais/diagnóstico por imagem , Humanos , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Retrospectivos , Tíbia/diagnóstico por imagem , Adulto Jovem
7.
J Arthroplasty ; 34(7): 1430-1434, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30956048

RESUMO

BACKGROUND: The aim of this study is to assess the outcomes of 52 consecutive Vancouver B2 peri-prosthetic fractures around cemented polished double-tapered stems treated by open reduction and internal fixation in 2 trauma centers in 2 countries. METHODS: Outcomes included modified Harris Hip Score (mHHS), Harris Pain Score, and return to pre-injury mobility. Fracture healing was assessed; implant subsidence measured and complications including re-operations reported. RESULTS: No patient was lost to follow-up. Median patient age at operation was 82 years (range 43-98); Harris pain scores showed minimal pain (median 42, range 10-44) at latest follow-up. Median total subsidence at 1 year was 1.1 mm (range 0-5.4), the majority of which occurred within the cement mantle. No subsequent femoral stem revision was required (median 2.9 years, 0-10); however, there were 3 re-operations: 1 re-operation for pre-existing recurrent dislocation involving head liner exchange and 2 for repeat fixation due to metal fatigue. Two additional fractures occurred below the new plating, requiring further plating whilst still retaining the original stems. CONCLUSION: Anatomical reduction and open reduction and internal fixation of Vancouver B2 peri-prosthetic fractures should be considered as an appropriate treatment solution for frail elderly patients with a peri-prosthetic fracture around cemented polished double-tapered stems.


Assuntos
Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas , Fraturas Periprotéticas/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Cimentos Ósseos , Feminino , Fêmur/cirurgia , Consolidação da Fratura , Prótese de Quadril/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Fraturas Periprotéticas/etiologia , Reoperação/estatística & dados numéricos , Estudos Retrospectivos
8.
J Orthop Traumatol ; 20(1): 12, 2019 02 26.
Artigo em Inglês | MEDLINE | ID: mdl-30806822

RESUMO

BACKGROUND: Tibial plateau fracture classifications are based on anteroposterior radiographs. Precontoured locking plates are commonly used to treat such fractures. The aims of this study are to: (1) describe tibial plateau fracture anatomy in the axial plane and (2) assess whether current plating systems allow screws to be placed suitably. MATERIALS AND METHODS: A graphical tibial plateau template was developed. One hundred twenty-five tibial plateau fractures (four bilateral) were reviewed (80 men, 41 women; average age 45.5 years, range 21-77.7 years). The axial computed tomography (CT) slice 0.3-0.5 mm below the medial articular surface was reviewed in all cases. Fracture lines were drawn on the template. Four lateral locking plates were placed against a cadaveric adult tibia. Based on the projected screw directions, suitable fracture patterns were identified. Fractures were considered "suitable" if the screws passed 90 ± 22° to the fracture line. RESULTS: Two hundred sixty-one different fracture lines were identified. One hundred thirty-four fractures involved the lateral plateau; 96 were suitable for lateral plating. Ninety fractures involved the medial plateau, 82 were treatable using the various plate positions on medial-posterior aspect of the medial plateau. Thirty-seven fractures were bicondylar; 20 were treatable with a posteromedial plate. CONCLUSIONS: Tibial plateau fractures follow consistent patterns, with most lateral and medial plateau fracture lines being in the sagittal plane, although there is greater variation medially. Positioning of modern locking plates will deal effectively with 72 % of all lateral plateau fractures and 91 % of medial plateau fractures. LEVEL OF EVIDENCE: Level 3.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas/métodos , Tíbia/diagnóstico por imagem , Fraturas da Tíbia/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tíbia/lesões , Tíbia/cirurgia , Fraturas da Tíbia/cirurgia , Adulto Jovem
9.
J Arthroplasty ; 32(4): 1227-1233, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28082045

RESUMO

BACKGROUND: The risk of revision following primary total hip arthroplasty (THA) is increased in young patients who undergo THA for pathologies other than primary osteoarthritis. We report the results of primary THA performed with cemented polished stems in patients aged 40 years and younger for pathologies other than primary osteoarthritis. METHODS: We investigated 52 patients (65 hips) who underwent primary THA for secondary osteoarthritis with a cemented tapered polished stem between 1990 and 2007. Clinical and radiographic outcomes, available in 46 patients (57 hips), included the Harris Hip Scores, Societe Internationale de Chirurgie Orthopedique et de Traumatologie activity, patient satisfaction, stem survival and reoperations, and assessment of prosthesis-cement-bone radiolucencies, osteolysis, and femoral bone deficiencies. RESULTS: Median patient age was 34 years (16-40) and follow-up was 14 years (mean 13, range 5-22). Stem survival to the endpoint revision for loosening was 100% and to the endpoint revision for any reason, excluding infection was 88% (95% confidence interval 78-98) at 16 years. No stem was revised for aseptic loosening. Nine stems were revised for other reasons. Radiographically, one stem was definitely loose at 16 years. The median patient Harris pain score improved from marked pain to no pain at latest follow-up. Patient activity level improved, albeit minimally, for 8 years after surgery. At latest follow-up, 98% of the patients remained satisfied with their surgery. CONCLUSION: Primary THA with a cemented polished stem shows excellent results in young patients with pathology other than primary osteoarthritis. In addition, the stem design facilitates cement within cement exchange and therefore preservation of proximal femoral bone stock at revision surgery.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril/estatística & dados numéricos , Desenho de Prótese , Adolescente , Adulto , Cimentos Ósseos , Feminino , Fêmur , Seguimentos , Humanos , Masculino , Dor/etiologia , Satisfação do Paciente , Satisfação Pessoal , Radiografia , Reoperação , Adulto Jovem
10.
Clin Orthop Relat Res ; 473(12): 3811-9, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26194560

RESUMO

BACKGROUND: The incidence of acetabular fractures in osteoporotic patients is increasing. Immediate total hip arthroplasty (THA) has potential advantages, but achieving acetabular component stability is challenging and, at early followup, reported revision rates for loosening are high. QUESTIONS/PURPOSES: This study measured acetabular component stability and the initial surface contact achieved between the acetabular component and unfractured region of the pelvis after THA using an oversized acetabular component and cup-cage reconstruction. METHODS: Between November 2011 and November 2013, we treated 40 acute acetabular fractures in patients older than 70 years of age. Of these, 12 (30%) underwent immediate THA using an oversized acetabular component with screws inserted only into the ilium and a cup-cage construct. Postoperatively all patients were mobilized without weightbearing restrictions. Indications for immediate THA after acetabular fractures were displaced articular comminution deemed unreducible. Eleven of the 12 were prospectively studied to evaluate the initial stability of the reconstructions using radiostereometric analysis. One of the patients died of a pulmonary embolism after surgery, and the remaining 10 (median age, 81 years; range, 72-86 years) were studied. Of these, five were analyzed at 1 year and five were analyzed at 2 years. Acetabular component migration was defined as acceptable if less than the limits for primary THA that predict later loosening (1.76 mm of proximal migration and 2.53° of sagittal rotation). The contact surface between the acetabular component and ilium in direct continuity with the sacroiliac joint, and the ischium and pubis in direct continuity with the symphysis pubis, was measured on postoperative CT scans. RESULTS: At 1 year the median proximal migration was 0.83 mm (range, 0.09-5.13 mm) and sagittal rotation was 1.3° (range, 0.1°-7.4°). Three of the 10 components had migration above the suggested limits for primary THA at 1 year postoperatively. The contact surface achieved at surgery between the acetabular component and pelvis ranged from 11 to 17 cm(2) (15%-27% of each component). CONCLUSIONS: The majority of acetabular components in this cohort were stable despite the small contact surface achieved between the component and pelvic bone. Three of 10 migrated in excess of the limits that predict later loosening in primary THA but it remains to be seen whether these limits apply to this selected group of frail osteoporotic patients. We continue to use this technique routinely to treat patients with the same indications, but since the analysis of these data we have added screw fixation of the acetabular component to the ischial tuberosity and the superior pubic ramus. LEVEL OF EVIDENCE: Level IV, therapeutic study.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/instrumentação , Fraturas do Quadril/cirurgia , Prótese de Quadril , Instabilidade Articular/prevenção & controle , Fraturas por Osteoporose/cirurgia , Falha de Prótese , Acetábulo/diagnóstico por imagem , Acetábulo/lesões , Acetábulo/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Fenômenos Biomecânicos , Densidade Óssea , Feminino , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/fisiopatologia , Humanos , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/etiologia , Instabilidade Articular/fisiopatologia , Masculino , Fraturas por Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/fisiopatologia , Estudos Prospectivos , Desenho de Prótese , Radiografia , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
11.
Acta Orthop ; 86(2): 159-68, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25301435

RESUMO

BACKGROUND AND PURPOSE: Wear rates of highly crosslinked polyethylene (XLPE) acetabular components have varied considerably between different published studies. This variation is in part due to the different techniques used to measure wear and to the errors inherent in measuring the relatively low amounts of wear in XLPE bearings. We undertook a scoping review of studies that have examined the in vivo wear of XLPE acetabular components using the most sensitive method available, radiostereometric analysis (RSA). METHODS: A systematic search of the PubMed, Scopus, and Cochrane databases was performed to identify published studies in which RSA was used to measure wear of XLPE components in primary total hip arthroplasty (THA). RESULTS: 18 publications examined 12 primary THA cohorts, comprising only 260 THAs at 2-10 years of follow-up. The mean or median proximal wear rate reported ranged from 0.00 to 0.06 mm/year. However, differences in the manner in which wear was determined made it difficult to compare some studies. Furthermore, differences in RSA methodology between studies, such as the use of supine or standing radiographs and the use of beaded or unbeaded reference segments, may limit future meta-analyses examining the effect of patient and implant variables on wear rates. INTERPRETATION: This scoping review confirmed the low wear rates of XLPE in THA, as measured by RSA. We make recommendations to enhance the standardization of reporting of RSA wear results, which will facilitate early identification of poorly performing implants and enable a better understanding of the effects of surgical and patient factors on wear.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Polietileno , Falha de Prótese , Análise Radioestereométrica , Acetábulo , Humanos
12.
J Arthroplasty ; 29(4): 769-76, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24060495

RESUMO

This study investigated the variability of os coxae's volume and linear morphometry in 50 dry adult bones. There was a wide variability, with coefficients of variation exceeding 30%, of the bones' volumes (mean 142 ml, range 80 to 300 ml) and distances between the acetabular rim and the horizontal plane through the sciatic notch (mean 10.6 mm, range -7 to 19 mm). The smallest width of the ilium ranged between 3 and 9 mm at a level between 1.5 and 4 cm above the acetabulum. The volume of os coxae correlated with the acetabular diameter (r = 0.79), the height of os coxae (r = 0.88) and antero-posterior length of the ilium at mid-acetabular level (r = 0.70). Knowledge of the variability of os coxae may be useful during preoperative planning in primary and revision hip arthroplasty.


Assuntos
Acetábulo/anatomia & histologia , Artroplastia de Quadril , Ossos Pélvicos/anatomia & histologia , Acetábulo/cirurgia , Adulto , Idoso , Pesos e Medidas Corporais , Cadáver , Feminino , Articulação do Quadril/anatomia & histologia , Articulação do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Ossos Pélvicos/cirurgia , Adulto Jovem
13.
Arthroplast Today ; 27: 101344, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38524151

RESUMO

Background: The Australian Orthopedic Association National Joint Replacement Registry has developed a standardized multi-stage approach to identify prostheses with a higher-than-anticipated rate of revision when comparing a prosthesis of interest to all other prostheses within the same broad class. However, the approach does not adequately differentiate between the conventional and complex design prostheses, and the comparator classes need to be re-evaluated. This study aimed to identify a more relevant comparator to better reflect conventional and complex surgical practices according to the stability design and also explore how the rate of revision estimated in the comparator groups affects the identification of "prosthesis outliers." Methods: The cumulative percent revision (CPR) was calculated for 640,045 primary total knee replacements (TKRs) undertaken for Osteoarthritis from 1 January 2003 to 31 December 2019. At first, survivorship analyses were undertaken to calculate the rate of revision for primary TKR by stability design. A modified TKR comparator group was developed by excluding the "complex" group of prostheses with fully stabilized and hinged designs. The effectiveness of the modified comparator groups, including cruciate retaining and posterior stabilized designs, was evaluated based on the ability to detect additional prostheses by performing the Australian Orthopedic Association National Joint Replacement Registry standardized method for identifying prosthesis outliers. Results: The modified comparator to include only conventional designs had a 10-year CPR of 5.2% (5.1, 5.3). When the fully stabilized and hinged design groups were combined as a comparator group of complex devices to reflect devices used only for specific purposes in primary TKR, the CPR at 10 year was 10.3% (8.6, 12.0). Conclusions: The use of modified comparator groups led to identifying additional conventional prostheses but fewer complex designs as being at risk and has the potential to improve the early assessment of TKR prostheses.

14.
Front Cell Infect Microbiol ; 14: 1403289, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38915921

RESUMO

Staphylococcus aureus is a major causative pathogen of osteomyelitis. Intracellular infections of resident bone cells including osteocytes can persist despite gold-standard clinical intervention. The mechanisms by which intracellular S. aureus evades antibiotic therapy are unknown. In this study, we utilised an in vitro S. aureus infection model of human osteocytes to investigate whether antibiotic-mediated dysregulation of autophagy contributes to this phenomenon. Infected or non-infected osteocyte-like cells were exposed to combinations of rifampicin, vancomycin, and modulators of autophagy. Intracellular bacterial growth characteristics were assessed using colony-forming unit (CFU) analysis, viable bacterial DNA abundance, and the rate of escape into antibiotic-free medium, together with measures of autophagic flux. Rifampicin, alone or in combination with vancomycin, caused a rapid decrease in the culturability of intracellular bacteria, concomitant with stable or increased absolute bacterial DNA levels. Both antibiotics significantly inhibited autophagic flux. However, modulation of autophagic flux did not affect viable bacterial DNA levels. In summary, autophagy was shown to be a factor in the host-pathogen relationship in this model, as its modulation affected the growth state of intracellular S. aureus with respect to both their culturability and propensity to escape the intracellular niche. While rifampicin and vancomycin treatments moderately suppressed autophagic flux acutely, this did not explain the paradoxical response of antibiotic treatment in decreasing S. aureus culturability whilst failing to clear bacterial DNA and hence intracellular bacterial load. Thus, off-target effects of rifampicin and vancomycin on autophagic flux in osteocyte-like cells could not explain the persistent S. aureus infection in these cells.


Assuntos
Antibacterianos , Autofagia , Osteócitos , Rifampina , Infecções Estafilocócicas , Staphylococcus aureus , Vancomicina , Autofagia/efeitos dos fármacos , Staphylococcus aureus/efeitos dos fármacos , Staphylococcus aureus/fisiologia , Osteócitos/efeitos dos fármacos , Osteócitos/microbiologia , Antibacterianos/farmacologia , Humanos , Vancomicina/farmacologia , Rifampina/farmacologia , Infecções Estafilocócicas/microbiologia , Infecções Estafilocócicas/tratamento farmacológico , Interações Hospedeiro-Patógeno , DNA Bacteriano/genética
15.
J Orthop Res ; 42(2): 373-384, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37526382

RESUMO

While finite element (FE) models have been used extensively in orthopedic studies, validation of their outcome metrics has been limited to comparison against ex vivo testing. The aim of this study was to validate FE model predictions of the initial cup mechanical environment against patient-matched in vivo measurements of acetabular cup migration using radiostereometric analysis (RSA). Tailored musculoskeletal and FE models were developed using a combination of three-dimensional (3D) motion capture data and clinical computerized tomography (CT) scans for a cohort of eight individuals who underwent primary total hip replacement and were prospectively enrolled in an RSA study. FE models were developed to calculate the mean modulus of cancellous bone, composite peak micromotion (CPM), composite peak strain (CPS) and percentage area of bone ingrowth. The RSA cup migration at 3 months was used to corroborate the FE output metrics. Qualitatively, all FE-predicted metrics followed a similar rank order as the in vivo RSA 3D migration data. The two cases with the lowest predicted CPM (<20 µm), lowest CPS (<0.0041), and high bone modulus (>917 MPa) were confirmed to have the lowest in vivo RSA 3D migration (<0.14 mm). The two cases with the largest predicted CPM (>80 µm), larger CPS (>0.0119) and lowest bone modulus (<472 MPa) were confirmed to have the largest in vivo RSA 3D migration (>0.78 mm). This study enabled the first corroboration between tailored musculoskeletal and FE model predictions with in vivo RSA cup migration. Investigation of additional patient-matched CT, gait, and RSA examinations may allow further development and validation of FE models.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Análise Radioestereométrica/métodos , Análise de Elementos Finitos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Artroplastia de Quadril/métodos
16.
ANZ J Surg ; 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38597170

RESUMO

Prediction models are being increasingly used in the medical field to identify risk factors and possible outcomes. Some of these are presently being used to develop guidelines for improving clinical practice. The application of machine learning (ML), comprising a powerful set of computational tools for analysing data, has been clearly expanding in the role of predictive modelling. This paper reviews the latest developments of supervised ML techniques that have been used to analyse data related to post-operative total hip and knee replacements. The aim was to review the most recent findings of relevant published studies by outlining the methodologies employed (most-widely used supervised ML techniques), data sources, domains, limitations of predictive analytics and the quality of predictions.

17.
Bone Joint J ; 106-B(5 Supple B): 74-81, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38688495

RESUMO

Aims: The aim of this study was to compare the biomechanical models of two frequently used techniques for reconstructing severe acetabular defects with pelvic discontinuity in revision total hip arthroplasty (THA) - the Trabecular Metal Acetabular Revision System (TMARS) and custom triflange acetabular components (CTACs) - using virtual modelling. Methods: Pre- and postoperative CT scans from ten patients who underwent revision with the TMARS for a Paprosky IIIB acetabular defect with pelvic discontinuity were retrospectively collated. Computer models of a CTAC implant were designed from the preoperative CT scans of these patients. Computer models of the TMARS reconstruction were segmented from postoperative CT scans using a semi-automated method. The amount of bone removed, the implant-bone apposition that was achieved, and the restoration of the centre of rotation of the hip were compared between all the actual TMARS and the virtual CTAC implants. Results: The median amount of bone removed for TMARS reconstructions was significantly greater than for CTAC implants (9.07 cm3 (interquartile range (IQR) 5.86 to 21.42) vs 1.16 cm3 (IQR 0.42 to 3.53) (p = 0.004). There was no significant difference between the median overall implant-bone apposition between TMARS reconstructions and CTAC implants (54.8 cm2 (IQR 28.2 to 82.3) vs 56.6 cm2 (IQR 40.6 to 69.7) (p = 0.683). However, there was significantly more implant-bone apposition within the residual acetabulum (45.2 cm2 (IQR 28.2 to 72.4) vs 25.5 cm2 (IQR 12.8 to 44.1) (p = 0.001) and conversely significantly less apposition with the outer cortex of the pelvis for TMARS implants compared with CTAC reconstructions (0 cm2 (IQR 0 to 13.1) vs 23.2 cm2 (IQR 16.4 to 30.6) (p = 0.009). The mean centre of rotation of the hip of TMARS reconstructions differed by a mean of 11.1 mm (3 to 28) compared with CTAC implants. Conclusion: In using TMARS, more bone is removed, thus achieving more implant-bone apposition within the residual acetabular bone. In CTAC implants, the amount of bone removed is minimal, while the implant-bone apposition is more evenly distributed between the residual acetabulum and the outer cortex of the pelvis. The differences suggest that these implants used to treat pelvic discontinuity might achieve short- and long-term stability through different biomechanical mechanisms.


Assuntos
Acetábulo , Artroplastia de Quadril , Prótese de Quadril , Desenho de Prótese , Reoperação , Tantálio , Tomografia Computadorizada por Raios X , Humanos , Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Artroplastia de Quadril/instrumentação , Feminino , Masculino , Idoso , Estudos Retrospectivos , Pessoa de Meia-Idade , Fenômenos Biomecânicos , Idoso de 80 Anos ou mais , Falha de Prótese , Porosidade
18.
Clin Orthop Relat Res ; 471(7): 2259-65, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23412731

RESUMO

BACKGROUND: The Paprosky acetabular defect classification is widely used but has not been appropriately validated. Reliability of the Paprosky system has not been evaluated in combination with standardized techniques of measurement and scoring. QUESTIONS/PURPOSES: This study evaluated the reliability, teachability, and validity of the Paprosky acetabular defect classification. METHODS: Preoperative radiographs from a random sample of 83 patients undergoing 85 acetabular revisions were classified by four observers, and their classifications were compared with quantitative intraoperative measurements. Teachability of the classification scheme was tested by dividing the four observers into two groups. The observers in Group 1 underwent three teaching sessions; those in Group 2 underwent one session and the influence of teaching on the accuracy of their classifications was ascertained. RESULTS: Radiographic evaluation showed statistically significant relationships with intraoperative measurements of anterior, medial, and superior acetabular defect sizes. Interobserver reliability improved substantially after teaching and did not improve without it. The weighted kappa coefficient went from 0.56 at Occasion 1 to 0.79 after three teaching sessions in Group 1 observers, and from 0.49 to 0.65 after one teaching session in Group 2 observers. CONCLUSIONS: The Paprosky system is valid and shows good reliability when combined with standardized definitions of radiographic landmarks and a structured analysis. LEVEL OF EVIDENCE: Level II, diagnostic study. See the Guidelines for Authors for a complete description of levels of evidence.


Assuntos
Acetábulo/diagnóstico por imagem , Acetábulo/patologia , Acetábulo/cirurgia , Pontos de Referência Anatômicos , Artroplastia de Quadril , Humanos , Variações Dependentes do Observador , Valor Preditivo dos Testes , Radiografia , Reoperação , Reprodutibilidade dos Testes
19.
J Arthroplasty ; 28(5): 740-6, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23454106

RESUMO

A systematic literature review was conducted to identify the best available evidence describing the differences in clinical outcome associated with the different methods of total knee replacement (TKR) fixation. Randomized trials published between 1980 and January 2011 comparing differences in clinical outcome scores between groups allocated to either cemented or uncemented fixation for TKR were included. Nine of the 11 studies included in the review reported no significant differences in clinical outcomes between groups with either cemented or uncemented prosthesis components. Critical appraisal of methodological bias revealed consistent shortcomings in study design and execution. It is apparent that more rigorous studies with longer follow-up periods are required to verify which method of fixation may be preferable in enhancing clinical outcomes.


Assuntos
Artroplastia do Joelho/métodos , Cimentação/métodos , Humanos , Patela/cirurgia , Ligamento Cruzado Posterior/cirurgia , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento
20.
Inflammopharmacology ; 21(6): 389-96, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24127125

RESUMO

Periprosthetic osteolysis is a serious complication of total hip replacement (THR) in the medium to long term. Although often asymptomatic, osteolysis can lead to prosthesis loosening and periprosthetic fracture. These complications cause significant morbidity and require complex revision surgery. Here, we review advances in our understanding of the cell and tissue response to particles produced by wear of the articular and non-articular surfaces of prostheses. We discuss the molecular and cellular regulators of osteoclast formation and bone resorptive activity, a better understanding of which may lead to pharmacological treatments for periprosthetic osteolysis. We describe the development of imaging techniques for the detection and measurement of osteolysis around THR prostheses, which enable improved clinical management of patients, provide a means of evaluating outcomes of non-surgical treatments for periprosthetic osteolysis, and assist in pre-operative planning for revision surgery. Finally, there have been advances in the materials used for bearing surfaces to minimise wear, and we review the literature regarding the performance of these new materials to date.


Assuntos
Artroplastia de Quadril/efeitos adversos , Osso e Ossos/imunologia , Macrófagos/imunologia , Osteólise/etiologia , Fraturas Periprotéticas/prevenção & controle , Fagocitose , Complicações Pós-Operatórias/prevenção & controle , Animais , Artroplastia de Quadril/tendências , Reabsorção Óssea/etiologia , Reabsorção Óssea/imunologia , Reabsorção Óssea/patologia , Reabsorção Óssea/prevenção & controle , Substitutos Ósseos/efeitos adversos , Substitutos Ósseos/química , Substitutos Ósseos/uso terapêutico , Osso e Ossos/diagnóstico por imagem , Osso e Ossos/patologia , Osso e Ossos/cirurgia , Humanos , Mediadores da Inflamação/metabolismo , Macrófagos/metabolismo , Fenômenos Mecânicos , Osteoclastos/imunologia , Osteoclastos/metabolismo , Osteoclastos/patologia , Osteólise/diagnóstico por imagem , Osteólise/fisiopatologia , Osteólise/terapia , Fraturas Periprotéticas/etiologia , Polietilenos/efeitos adversos , Polietilenos/química , Polietilenos/uso terapêutico , Complicações Pós-Operatórias/etiologia , Falha de Prótese , Propriedades de Superfície , Tomografia Computadorizada por Raios X , Suporte de Carga
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA