RESUMO
INTRODUCTION: Thermal atrial fibrillation (AF) ablation exerts an additive treatment effect on the cardiac autonomic nervous system (CANS). This effect is mainly reported during ablation of the right superior pulmonary vein (RSPV), modulating the right anterior ganglionated plexus (RAGP), which contains parasympathetic innervation to the sinoatrial node in the epicardial fat pad between RSPV and superior vena cava (SVC). However, a variable response to neuromodulation after ablation is observed, with little to no effect in some patients. Our objective was to assess clinical and anatomic predictors of thermal ablation-induced CANS changes, as assessed via variations in heart rate (HR) postablation. METHODS: Consecutive paroxysmal AF patients undergoing first-time PV isolation by the cryoballoon (CB) or radiofrequency balloon (RFB) within a 12-month time frame and with preprocedural cardiac computed tomography (CT), were evaluated. Preablation and 24-h postablation electrocardiograms in sinus rhythm were collected and analyzed to assess HR. Anatomic evaluation by CT included the measurement of the shortest distance between the SVC and RSPV ostium (RSPV-SVC distance). RESULTS: A total of 97 patients (CB, n = 50 vs. RFB, n = 47) were included, with similar baseline characteristics between both groups. A significant HR increase postablation (ΔHR ≥ 15 bpm) occurred in a total of 37 patients (38.1%), without difference in number of patients between both thermal ablation technologies (CB, 19 [51%]), RFB, 18 [49%]). Independent predictors for increased HR were RSPV-SVC distance (odds ratio [OR]: 0.49, CI: 0.34-0.71, p value < .001), and age (OR: 0.94, CI: 0.89-0.98, p value = .003). CONCLUSIONS: Thermal balloon-based PV isolation influences the CANS through its effect on the RAGP, especially in younger patients and patients with shorter RSPV-SVC distance.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Frequência Cardíaca , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Criocirurgia/efeitos adversos , Ablação por Cateter/efeitos adversos , Fatores de Tempo , Potenciais de Ação , Veia Cava Superior/cirurgia , Veia Cava Superior/fisiopatologia , Sistema Nervoso Autônomo/fisiopatologia , Sistema Nervoso Autônomo/cirurgia , Estudos Retrospectivos , Fatores de RiscoRESUMO
AIMS: Rhythm control of non-paroxysmal atrial fibrillation (AF) is significantly more challenging, as a result of arrhythmia perpetuation promoting atrial substrate changes and AF maintenance. We describe a tailored ablation strategy targeting multiple left atrial (LA) sites via a pentaspline pulsed field ablation (PFA) catheter in persistent AF sustained beyond 6 months (PerAF > 6â m) and long-standing persistent AF (LSPAF). METHODS AND RESULTS: The ablation protocol included the following stages: pulmonary vein antral and posterior wall isolation plus anterior roof line ablation (Stage 1); electrogram-guided substrate ablation (Stage 2); atrial tachyarrhythmia regionalization and ablation (Stage 3). Seventy-two [age:68 ± 10years, 61.1%males; AF history: 25 (18-45) months] patients with PerAF > 6â m (52.8%) and LSPAF (47.2%) underwent their first PFA via the FarapulseTM system. LA substrate ablation (Stage 1 and 2) led to AF termination in 95.8% of patients. AF organized into a left-sided atrial flutter (AFlu) in 46 (74.2%) patients. The PFA catheter was used to identify LA sites showing diastolic, low-voltage electrograms and entrainment from its splines was performed to confirm the pacing site was inside the AFlu circuit. Left AFlu termination was achieved in all cases via PFA delivery. Total procedural and LA dwell times were 112 ± 25â min and 59 ± 22â min, respectively. Major complications occurred in 2 (2.8%) patients. Single-procedure success rate was 74.6% after 14.9 ± 2.7 months of follow-up; AF-free survival was 89.2%. CONCLUSION: In our cohort, PFA-based AF substrate ablation led to AF termination in 95.8% of cases. Very favourable clinical outcomes were observed during >1 year of follow-up.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Humanos , Masculino , Ablação por Cateter/métodos , Feminino , Idoso , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Resultado do Tratamento , Recidiva , Fatores de Tempo , Cateteres Cardíacos , Frequência Cardíaca , Potenciais de AçãoRESUMO
INTRODUCTION: Pulmonary vein isolation (PVI) with thermal energy is characterized by concomitant ablation of the surrounding ganglionated plexi (GP). Pulsed-field ablation (PFA) selectively targets the myocardium and seems associated with only negligible effects on the autonomic nervous system (ANS). However, little is known about the dynamic effects of PFA on the GP immediately after PVI. This study sought to investigate the degree and acute vagal modulation induced by the FarapulseTM PFA system during PVI compared with single-shot thermal ablation. METHODS: A total of 76 patients underwent first-time PVI with either FarapulseTM PFA (PFA group, n = 40) or cryoballoon ablation (thermal ablation group, n = 36) for paroxysmal atrial fibrillation (AF). The effect on the ANS in the two groups was assessed before and after PVI with extracardiac vagal stimulation (ECVS). To capture any transient effects of PFA on the ANS, in a subgroup of PFA patients ECVS was repeated at three predefined timepoints: (1) before PVI (T0); (2) immediately after PVI (T1); and (3) 10 min after the last energy application (T2). RESULTS: Despite similar baseline values, the vagal response induced by ECVS after PVI almost disappeared in the thermal ablation group but persisted in the PFA group (thermal group: 840 [706-1090] ms, p < .001 compared to baseline; PFA group: 11 466 [8720-12 293] ms, p = .70 compared to baseline). Intraprocedural vagal reactions (defined as RR increase >50%, transitory asystole, or atrioventricular block) occurred more frequently with PFA than thermal ablation (70% vs. 28%, p = .001). Moreover, heart rate 24 h post-PVI increased more with thermal ablation than with PFA (16.5 ± 9.0 vs. 2.6 ± 6.1 beats/min, p < .001). In the subgroup of PFA patients undergoing repeated ANS modulation assessment (n = 11), ECVS demonstrated that PFA determined a significant acute suppression of the vagal response immediately after PVI (p < .001 compared to baseline), which recovered almost completely within 10 min. CONCLUSION: PVI with the FarapulseTM PFA system is associated with only transitory and short-lasting vagal effects on the ANS which recover almost completely within a few minutes after ablation. The impact of this phenomenon on AF outcome needs to be further investigated.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Sistema Nervoso Autônomo/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Nervo Vago/cirurgia , Frequência Cardíaca , Ablação por Cateter/efeitos adversos , Resultado do TratamentoRESUMO
INTRODUCTION: Cardiac involvement is common and may become clinically relevant in approximately 5%-10% of patients with systemic sarcoidosis. Although reduced left ventricular ejection fraction is a recognized predictor of mortality, recent studies have suggested an increased risk of ventricular arrhythmia (VAs) and sudden cardiac death (SCD) in patients with cardiac sarcoidosis (CS) and evidence of late gadolinium enhancement-cardiac magnetic resonance (LGE-CMR), irrespective of the underlying left ventricular systolic function. We performed a meta-analysis to assess the correlation between VAs/SCD and presence of LGE-CMR in CS patients. METHODS: We systematically searched Medline, Embase, and Cochrane electronic databases up to January 2, 2023, for studies enrolling patients with suspected or confirmed CS undergoing LGE-CMR. Clinical outcomes of interest included clinically relevant VAs, defined as sustained ventricular tachycardia, ventricular fibrillation, SCD, or aborted SCD during follow-up. The effect size was estimated using a random-effect model as risk ratio (RR) and relative 95% confidence interval (CI). RESULTS: A total of 14 studies fulfilled the selection criteria and were included in the final analysis. Among 1273 patients, LGE was detected in 465 (36.5%; Group LGE+). Males accounted for 45.2% (95% CI: 40.5%-55.7%) of the total population and the average age was 56.8 (95% CI: 52.7%-60.9) years. A total of 104 (22.3%) of 465 LGE+ patients experienced a clinically relevant VA, compared to 6 (0.7%) of 808 LGE- ones. LGE+ was associated with a ninefold increased risk in life-threatening VAs (22.3% vs. 0.7%; RR = 9.52; 95% CI [5.18-17.49]; p < .0001) compared to patients without LGE (heterogeneity I2 = 0%). CONCLUSION: In our meta-analysis, LGE+ in patients with CS was associated with a ninefold increased risk in life-threatening VAs compared to patients without LGE.
Assuntos
Miocardite , Sarcoidose , Humanos , Masculino , Pessoa de Meia-Idade , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/complicações , Meios de Contraste , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/epidemiologia , Gadolínio , Imagem Cinética por Ressonância Magnética , Espectroscopia de Ressonância Magnética/efeitos adversos , Miocardite/complicações , Prognóstico , Medição de Risco , Fatores de Risco , Sarcoidose/complicações , Sarcoidose/diagnóstico por imagem , Volume Sistólico , Função Ventricular EsquerdaRESUMO
With the increasing interest in conduction system pacing (CSP) over the last few years and the inclusion of this treatment modality in the current guidelines, our aim was to provide a snapshot of current practice across Europe. An online questionnaire was sent to physicians participating in the European Heart Rhythm Association research network as well as to national societies and over social media. Data on previous experience with CSP, current indications, preferred tools, unmet needs, and perceptions for the future are reported and discussed.
Assuntos
Fascículo Atrioventricular , Sistema de Condução Cardíaco , Humanos , Doença do Sistema de Condução Cardíaco , Inquéritos e Questionários , Europa (Continente) , Estimulação Cardíaca Artificial , EletrocardiografiaRESUMO
AIMS: Cryoballoon (CB) ablation is the mainstay of single-shot pulmonary vein isolation (PVI). A radiofrequency balloon (RFB) catheter has recently emerged as an alternative. However, these two technologies have not been compared. This study aims to evaluate the freedom from atrial tachyarrhythmias (ATas) at 1â year: procedural characteristics, efficacy, and safety of the novel RFB compared with CB for PVI in patients with paroxysmal atrial fibrillation (AF). METHODS AND RESULTS: This prospective multi-centre study included consecutive patients with symptomatic drug-resistant paroxysmal AF who underwent PVI with RFB or CB between July 2021 and January 2022 from three European centres. A total of 375 consecutive patients were included, 125 in the RFB group and 250 in the CB. Both groups had comparable clinical characteristics. At 12.33 ± 4.91â months, ATas-free rates were 83.20% and 82.00% in the RFB and CB groups, respectively (P > 0.05). Compared with the CB group, the RFB group showed a shorter procedure time [59.91 (45.80-77.12) vs. 77.0 (35.13-122.71)â min (P < 0.001)], dwell time [19.59 (14.41-30.24) vs. 27.03 (17.11-57.21)â min (P = 0.04)], time to isolation, and thermal energy delivery in all pulmonary veins (P < 0.001). First-pass isolation was comparable. No major complications occurred in either group, with no stroke, atrio-oesophageal fistula, or permanent phrenic nerve injury. Transient phrenic nerve palsy occurred more frequently with CB than RFB (7.20% vs. 3.20%; P = 0.02). Oesophageal temperature rise occurred in 21 (16.8%) patients in the RFB group, and gastroscopy showed erythema in two of them with complete recovery after 30â days. CONCLUSIONS: The RFB appears to have a safety and efficacy profile similar to that of the CB for PVI. Shorter procedural times appear to be driven by shorter left atrial dwell and thermal delivery times.
Assuntos
Apêndice Atrial , Fibrilação Atrial , Fístula Esofágica , Veias Pulmonares , Humanos , Estudos ProspectivosRESUMO
AIMS: The multielectrode radiofrequency balloon catheter (RFB) has been developed to achieve safe and effective pulmonary vein isolation (PVI) for atrial fibrillation (AF) ablation. This single-centre study aimed to evaluate the midterm clinical outcome and predictors of single-shot PVI with the novel RFB. METHODS AND RESULTS: All consecutive patients with symptomatic paroxysmal or persistent AF undergoing first-time PVI with the RFB were prospectively included. Clinical and procedural parameters were systematically collected. The primary safety endpoint was defined as any major periprocedural complications. The primary efficacy endpoint consisted of freedom from any atrial tachyarrhythmias (ATas) lasting >30 s during the follow-up after a 3-month blanking period. Persistent single-shot PVI was defined as PVI achieved with a single RFB application without acute reconnection. A total of 104 consecutive patients (mean age 64.3 ± 11.4 years, 56.7% males) were included. 15 patients (14.4%) presented with persistent AF. The procedure time was 59.0 min with a dwell time of 20.0 min. One major complication occurred in one patient. At a mean follow-up of 10.1 ± 5.3 months, freedom from ATas was 82.9%. ATas occurred in 14 patients, 11/69 patients (15.9%) with paroxysmal AF and 3/13 (23.1%) with persistent AF. The best cut-offs to predict persistent single-shot PVI were impedance drop >19.2 Ω [area under the receiver operator characteristic curve (AUC) 0.74] and temperature rise >11.1° C (AUC 0.77). CONCLUSION: In a large cohort of patients undergoing PVI with the RFB, the complication rate was 1%. At a mid-term follow-up of 10.1 ± 5.3 months, freedom from ATas was 82.9%. Specific cut-offs of impedance drop and temperature rise may be useful to predict persistent single-shot isolation.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Resultado do Tratamento , Seguimentos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Taquicardia/cirurgia , Catéteres , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , RecidivaRESUMO
AIMS: Catheter ablation (CA) is an established treatment for atrial fibrillation (AF). A computed tomography (CT) may be performed before ablation to evaluate the anatomy of pulmonary veins. The aim of this study is to investigate the prevalence of patients with coronary artery disease (CAD) detected by cardiac CT scan pre-ablation and to evaluate the impact of CAD and revascularization on outcomes after AF ablation. METHODS AND RESULTS: All consecutive patients with AF diagnosis, hospitalized at Universitair Ziekenhuis Brussel, Belgium, between 2015 and 2019, were prospectively screened for enrolment in the study. Inclusion criteria were (i) AF diagnosis, (ii) first procedure of AF ablation with cryoballoon CA, and (iii) contrast CT scan performed pre-ablation. A total of 576 consecutive patients were prospectively included and analysed in this study. At CT scan, 122 patients (21.2%) were diagnosed with CAD, of whom 41 patients (7.1%) with critical CAD. At survival analysis, critical CAD at CT scan was a predictor of atrial tachyarrhythmia (AT) recurrence during the follow-up, only in Cox univariate analysis [hazard ratio (HR) = 1.79] but was not an independent predictor in Cox multivariate analysis. At Cox multivariate analysis, independent predictors of AT recurrence were as follows: persistent AF (HR = 2.93) and left atrium volume index (HR = 1.04). CONCLUSION: In patients undergoing CT scan before AF ablation, critical CAD was diagnosed in 7.1% of patients. Coronary artery disease and revascularization were not independent predictors of recurrence; thus, in this patient population, AF ablation should not be denied and can be performed together with CAD treatment.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Doença da Artéria Coronariana , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/cirurgia , Resultado do Tratamento , Átrios do Coração , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , RecidivaRESUMO
AIMS: Hybrid atrial fibrillation (AF) ablation is a promising approach in non-paroxysmal AF. The aim of this study is to assess the long-term outcomes of hybrid ablation in a large cohort of patients after both an initial and as a redo procedure. METHODS AND RESULTS: All consecutive patients undergoing hybrid AF ablation at UZ Brussel from 2010 to 2020 were retrospectively evaluated. Hybrid AF ablation was performed in a one-step procedure: (i) thoracoscopic ablation followed by (ii) endocardial mapping and eventual ablation. All patients received PVI and posterior wall isolation. Additional lesions were performed based on clinical indication and physician judgement. Primary endpoint was freedom from atrial tachyarrhythmias (ATas). A total of 120 consecutive patients were included, 85 patients (70.8%) underwent hybrid AF ablation as first procedure (non-paroxysmal AF 100%), 20 patients (16.7%) as second procedure (non-paroxysmal AF 30%), and 15 patients (12.5%) as third procedure (non-paroxysmal AF 33.3%). After a mean follow-up of 62.3 months ± 20.3, a total of 63 patients (52.5%) experienced ATas recurrence. Complications occurred in 12.5% of patients. There was no difference in ATas between patients undergoing hybrid as first vs. redo procedure (P = 0.53). Left atrial volume index and recurrence during blanking period were independent predictors of ATas recurrence. CONCLUSION: In a large cohort of patients undergoing hybrid AF ablation, the survival from ATas recurrence was 47.5% at ≈5 years follow-up. There was no difference in clinical outcomes between patients undergoing hybrid AF ablation as first procedure or as a redo.
Assuntos
Técnicas de Ablação , Fibrilação Atrial , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Seguimentos , Átrios do Coração , Estudos Retrospectivos , Taquicardia , Resultado do TratamentoRESUMO
AIMS: A novel sinus node (SN) sparing hybrid ablation for inappropriate sinus node tachycardia (IST)/postural orthostatic tachycardia syndrome (POTS) has been demonstrated to be an effective and safe therapeutic option in patients with symptomatic drug-resistant IST/POTS. The aim of this study was to evaluate the long-term rate of redo procedures after hybrid IST ablation and procedural strategy, outcomes and safety of redo procedures. METHODS AND RESULTS: All consecutive patients from 2015 to 2023 were prospectively enrolled in the UZ Brussel monocentric IST/POTS registry. They were analysed if the following inclusion criteria were fulfilled: 1) diagnosis of IST or POTS, 2) symptomatic IST/POTS refractory or intolerant to drugs, and 3) hybrid SN sparing ablation performed. The primary endpoint was redo procedure. The primary safety endpoint was pacemaker (PM) implantation. A total of 220 patients undergone to hybrid IST ablation were included, 185 patients (84.1%) were treated for IST and 61 patients (27.7%) for POTS.After a follow-up of 73.3 ± 16.2 months, 34 patients (15.4%) underwent a redo. A total of 23 patients (67.6%) had a redo for IST recurrence and 11 patients (32.4%) for other arrhythmias. Pacemaker implantation was performed in 21 patients (9.5%). Nine patients (4.1%) had no redo procedure and experienced sick sinus syndrome requiring a PM. Twelve patients (5.4%) received a PM as a shared therapeutic choice combined with SN ablation procedure. CONCLUSION: In a large cohort of patients the long-term free survival from redo procedure after hybrid IST ablation was 84.6% with a low PM implantation rate.
Assuntos
Ablação por Cateter , Taquicardia Sinusal , Humanos , Taquicardia Sinusal/diagnóstico , Taquicardia Sinusal/cirurgia , Taquicardia Sinusal/tratamento farmacológico , Nó Sinoatrial , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Frequência CardíacaRESUMO
AIMS: A pathogenic/likely pathogenic (P/LP) variant in SCN5A is found in 20-25% of patients with Brugada syndrome (BrS). However, the diagnostic yield and prognosis of gene panel testing in paediatric BrS is unclear. The aim of this study is to define the diagnostic yield and outcomes of SCN5A gene testing with ACMG variant classification in paediatric BrS patients compared with adults. METHODS AND RESULTS: All consecutive patients diagnosed with BrS, between 1992 and 2022, were prospectively enrolled in the UZ Brussel BrS registry. Inclusion criteria were: (i) BrS diagnosis; (ii) genetic analysis performed with a large gene panel; and (iii) classification of gene variants following ACMG guidelines. Paediatric patients were defined as ≤16 years of age. The primary endpoint was ventricular arrhythmias (VAs). A total of 500 BrS patients were included, with 63 paediatric patients and 437 adult patients. Among children with BrS, 29 patients (46%) had a P/LP variant (P+) in SCN5A and no variants were found in 34 (54%) patients (P-). After a mean follow-up of 125.9 months, 8 children (12.7%) experienced a VA, treated with implanted cardioverter defibrillator shock. At survival analysis, P- paediatric patients had higher VA-free survival during the follow-up, compared with P+ paediatric patients. P+ status was an independent predictor of VA. There was no difference in VA-free survival between paediatric and adult BrS patients for both P- and P+. CONCLUSION: In a large BrS cohort, the diagnostic yield for P/LP variants in the paediatric population is 46%. P+ children with BrS have a worse arrhythmic prognosis.
Assuntos
Síndrome de Brugada , Adulto , Humanos , Criança , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/genética , Síndrome de Brugada/terapia , Testes Genéticos , Arritmias Cardíacas/genética , Cardioversão Elétrica , Prognóstico , Eletrocardiografia/métodos , Canal de Sódio Disparado por Voltagem NAV1.5/genéticaRESUMO
AIMS: Atrial fibrillation (AF) and chronic kidney disease (CKD) often coexist and share an increased risk of thrombo-embolism (TE). CKD concomitantly predisposes towards a pro-haemorrhagic state. Our aim was to evaluate the prognostic value of CKD in patients undergoing percutaneous left atrial appendage occlusion (LAAO). METHODS AND RESULTS: A total of 2124 consecutive AF patients undergoing LAAO were categorized into CKD stage 1+2 (n = 1089), CKD stage 3 (n = 796), CKD stage 4 (n = 170), and CKD stage 5 (n = 69) based on the estimated glomerular filtration rate at baseline. The primary endpoint included cardiovascular (CV) mortality, TE, and major bleeding. The expected annual TE and major bleeding risks were estimated based on the CHA2DS2-VASc and HAS-BLED scores. A non-significant higher incidence of major peri-procedural adverse events (1.7 vs. 2.3 vs. 4.1 vs. 4.3) was observed with worsening CKD (P = 0.14). The mean follow-up period was 13 ± 7 months (2226 patient-years). In comparison to CKD stage 1+2 as a reference, the incidence of the primary endpoint was significantly higher in CKD stage 3 (log-rank P-value = 0.04), CKD stage 4 (log-rank P-value = 0.01), and CKD stage 5 (log-rank P-value = 0.001). Left atrial appendage occlusion led to a TE risk reduction (RR) of 72, 66, 62, and 41% in each group. The relative RR of major bleeding was 58, 44, 51, and 52%, respectively. CONCLUSION: Patients with moderate-to-severe CKD had a higher incidence of the primary composite endpoint. The relative RR in the incidence of TE and major bleeding was consistent across CKD groups.
Assuntos
Apêndice Atrial , Fibrilação Atrial , Insuficiência Renal Crônica , Acidente Vascular Cerebral , Humanos , Apêndice Atrial/cirurgia , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Prognóstico , Resultado do Tratamento , Estudos Retrospectivos , Hemorragia/induzido quimicamente , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/epidemiologia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Anticoagulantes/efeitos adversosRESUMO
AIMS: Pulsed field ablation (PFA) has emerged as a novel, non-thermal energy source to selectively ablate cardiac tissue. We describe a multicentre experience on pulmonary vein isolation (PVI) via the pentaspline Farapulse™ PFA system vs. thermal-based technologies in a propensity score-matched population of paroxysmal atrial fibrillation (PAF) patients. METHODS AND RESULTS: Propensity score matching was adopted to compare PVI-only ablation outcomes via the Farawave™ system (Group PFA), cryoballoon (Group CRYO), or focal radiofrequency (Group RF) (PFA:CRYO:RF ratio = 1:2:2). Among 1572 (mean age: 62.4 ± 11.3 years; 42.5% females) PAF patients undergoing first time PVI with either PFA (n = 174), CRYO (n = 655), or RF (n = 743), propensity score matching yielded 174 PFA, 348 CRYO, and 348 RF patients. First-pass isolation was achieved in 98.8% of pulmonary veins (PVs) with PFA, 81.5% with CRYO, and 73.1% with RF (P < 0.001). Procedural and dwell times were significantly shorter with PFA, whereas the availability of a 3D mapping system led to a significant reduction in X-ray exposure with RF. Overall complication rates were 3.4% (n = 6) with PFA, 8.6% (n = 30) with CRYO, and 5.5% (n = 19) with RF (P = 0.052). The 1-year Kaplan-Meier estimated freedom from any atrial tachyarrhythmia was 79.3% with PFA, 74.7% with CRYO, and 72.4% with RF (log-rank P-value: 0.24). Among 145 repeat ablation procedures, PV reconnection rate was 19.1% after PFA, 27.5% after CRYO, and 34.8% after RF (P = 0.01). CONCLUSION: Pulsed field ablation contributed to significantly shorter procedural times. Follow-up data showed a similar arrhythmia freedom, although a higher rate of PV reconnection was documented in post-CRYO and post-RF redo procedures.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Pontuação de Propensão , Resultado do Tratamento , Átrios do Coração , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , RecidivaRESUMO
INTRODUCTION: Cephalic vein cutdown (CVC) and axillary vein puncture (AVP) are both recommended for transvenous implantation of leads for cardiac implantable electronic devices (CIEDs). Nonetheless, it is still debated which of the two techniques has a better safety and efficacy profile. METHODS: We systematically searched Medline, Embase, and Cochrane electronic databases up to September 5, 2022, for studies that evaluated the efficacy and safety of AVP and CVC reporting at least one clinical outcome of interest. The primary endpoints were acute procedural success and overall complications. The effect size was estimated using a random-effect model as risk ratio (RR) and relative 95% confidence interval (CI). RESULTS: Overall, seven studies were included, which enrolled 1771 and 3067 transvenous leads (65.6% [n = 1162] males, average age 73.4 ± 14.3 years). Compared to CVC, AVP showed a significant increase in the primary endpoint (95.7 % vs. 76.1 %; RR: 1.24; 95% CI: 1.09-1.40; p = .001) (Figure 1). Total procedural time (mean difference [MD]: -8.25 min; 95% CI: -10.23 to -6.27; p < .0001; I2 = 0%) and venous access time (MD: -6.24 min; 95% CI: -7.01 to -5.47; p < .0001; I2 = 0%) were significantly shorter with AVP compared to CVC. No differences were found between AVP and CVC for incidence overall complications (RR: 0.56; 95% CI: 0.28-1.10; p = .09), pneumothorax (RR: 0.72; 95% CI: 0.13-4.0; p = .71), lead failure (RR: 0.58; 95% CI: 0.23-1.48; p = .26), pocket hematoma/bleeding (RR: 0.58; 95% CI: 0.15-2.23; p = .43), device infection (RR: 0.95; 95% CI: 0.14-6.60; p = .96) and fluoroscopy time (MD: -0.24 min; 95% CI: -0.75 to 0.28; p = .36). CONCLUSION: Our meta-analysis suggests that AVP may improve procedural success and reduce total procedural time and venous access time compared to CVC.
Assuntos
Veia Axilar , Venostomia , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Veia Axilar/cirurgia , Venostomia/métodos , Veia Subclávia , Punções/métodos , CoraçãoRESUMO
PURPOSE: Drug-induced type I Brugada syndrome (BrS) is associated with a ventricular arrhythmia (VA) rate of 1 case per 100 person-years. This study aims to evaluate changes in electrocardiographic (ECG) parameters such as microvolt T wave alternans (mTWA) and heart rate variability (HRV) at baseline and during ajmaline testing for BrS diagnosis. METHODS: Consecutive patients diagnosed with BrS during ajmaline testing with 5-year follow-up were included in this study. For comparison, a negative ajmaline control group and an isoproterenol control group were also included. ECG recordings during ajmaline or isoproterenol test were divided in two timeframes from which ECG parameters were calculated: a 5-min baseline timeframe and a 5-min drug timeframe. RESULTS: A total of 308 patients with BrS were included, 22 (0.7%) of which suffered VAs during follow-up. One hundred patients were included in both isoproterenol and negative ajmaline control groups. At baseline, there was no difference in ECG parameters between control groups and patients with BrS, nor between BrS with and without VAs. During ajmaline testing, BrS with VAs presented longer QRS duration [159 ± 34 ms versus 138 (122-155) ms, p = 0.006], higher maximum mTWA [33.8 (14.0-114) µV versus 8.00 (3.67-28.2) µV, p = 0.001], and lower power in low frequency band [25.6 (5.8-53.8) ms2 versus 129.5 (52.7-286) ms2, p < 0.0001] when compared to BrS without VAs. CONCLUSIONS: Ajmaline induced important HRV changes similar to those observed during isoproterenol. Increased mTWA was observed only in patients with BrS. BrS with VAs during follow-up presented worse changes during ajmaline test, including lower LF power and higher maximum mTWA which were independent predictors of events.
Assuntos
Ajmalina , Síndrome de Brugada , Humanos , Ajmalina/farmacologia , Síndrome de Brugada/diagnóstico , Frequência Cardíaca , Isoproterenol , Arritmias Cardíacas , Eletrocardiografia , PrognósticoRESUMO
On behalf of the European Heart Rhythm Association, we designed a survey, whose aim was to understand the trend(s) in the clinical management of idiopathic monomorphic premature ventricular contractions (PVCs) among European cardiologists and cardiac electrophysiologists. A total of 202 participants in the survey answered 27 multiple-choice questions on the clinical presentation, diagnosis and treatment of idiopathic monomorphic PVCs. The most common symptom in patients with idiopathic monomorphic PVCs is palpitations, according to the majority of responders (87%), followed by fatigue (29%) and dizziness (18%). Complete blood cell count, renal function with electrolytes levels, and thyroid function are the blood tests requested by the majority of respondents (65%, 92%, and 93%, respectively). Coronary artery disease and structural heart disease needs to be ruled out, according to the vast majority of participants (99%). A 24-h Holter ECG is the preferred ECG modality to assess the burden of PVCs (86% of respondents). Among the different option treatments, beta-blockers and class I antiarrhythmic drugs are by far (81% of respondents) the preferred pharmacological option in comparison with calcium antagonists and class III antiarrhythmic drugs. Catheter ablation has also a good reputation: 99% of responders are keen to use it, especially in patients with high burden of PVCs and when signs of cardiomyopathy occur.
Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros , Antiarrítmicos/uso terapêutico , Humanos , Inquéritos e Questionários , Resultado do Tratamento , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/terapiaRESUMO
BACKGROUND: Left atrial posterior wall isolation (LAPWI) is often performed in addition to pulmonary vein isolation (PVI) in the setting of persistent atrial fibrillation (AF) ablation. The aim of this study was to evaluate the feasibility and safety of a new cryoballoon ablation system in achieving PVI + LAPWI isolation. METHODS: The study was a prospective, non-randomized, single center study. Forty consecutive patients, undergoing PVI + LAPWI with the novel POLARx™, were compared to 40 consecutive patients who underwent the same procedure with the established Arctic Front Advance PRO™. RESULTS: Acute isolation was achieved in all PVs in both groups and left posterior wall isolation (LAPWI) was achieved in 38 patients (95%) in the POLARx group and in 36 patients (90%) in Arctic Front group. Procedural outcomes were similar between both groups, except for lower temperatures during cryoenergy in the POLARx group, for both pulmonary vein isolation (PVI) and LAPWI. CONCLUSION: LAPWI + PVI with the novel POLARx™ Cryoballoon is feasible and safe; the results are comparable with the Arctic Front Advance PRO™ system.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Estudos de Viabilidade , Humanos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Tecnologia , Resultado do TratamentoRESUMO
Conventional stylet-driven leads with extendable helix can be implanted successfully for left bundle branch area pacing (LBBAP) with a low acute complication rate. We report two cases in which lead repositioning after a first unsuccessful attempt to LBBAP was associated with fracture of the helix rotating mechanism and failure to fully extract the pacing lead.
Assuntos
Estimulação Cardíaca Artificial , Septo Interventricular , Fascículo Atrioventricular , Eletrocardiografia , Sistema de Condução Cardíaco , HumanosRESUMO
BACKGROUND: Pulmonary vein (PV) isolation is an established treatment for paroxysmal drug-refractory atrial fibrillation (AF). High parasympathetic tone and reconnection of PVs have demonstrated to be possible culprits of AF recurrence after ablation. Our aim was to investigate the association between parasympathetic tone and reconnected PVs in patients with paroxysmal AF. METHODS: Consecutive patients who underwent a redo catheter ablation procedure for atrial tachyarrhythmia recurrence by means of 3D electroanatomic mapping with documentation of presence or absence of PVs reconnection following an initial procedure of cryoballoon (CB) ablation for symptomatic drug-refractory paroxysmal AF were screened for the study. RESULTS: A total of 92 patients were included, of whom 50 (54.35%) were males. Reconnected PVs were found in 64 (69%) patients. PVs reconnection could be predicted by DC (C-statistic = .770), by SDNNI (C-statistic = .714) and by absolute VLF power (C-statistic = .722), while right-sided PVs reconnection could be better predicted by DC (C-statistic = .848) and by SDNNI (C-statistic = .761). In multivariate binary logistic regression analysis, a DC value ≥6.45 ms and an absolute VLF power value ≥160 ms2 were associated with three times and five times higher odds of PVs reconnection, respectively. On a vein-per-vein analysis, absolute VLF power ≥160 ms2 was associated with three times higher odds, while reaching of -40°C within 60 s was associated with three times lower odds of PVs reconnection. CONCLUSION: High parasympathetic tonus accurately predicts PVs reconnection. On a vein-per-vein analysis, parasympathetic markers along with biophysical parameters predicted PVs reconnection. On a case-by-case analysis, parasympathetic markers were the only predictors of PVs reconnection, thus being a robust PVs reconnection prediction tool.
Assuntos
Fibrilação Atrial/cirurgia , Sistema Nervoso Autônomo/fisiopatologia , Criocirurgia/métodos , Veias Pulmonares/cirurgia , Nervo Vago/fisiopatologia , Adulto , Mapeamento Epicárdico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , ReoperaçãoRESUMO
OBJECTIVES: To investigate safety and diagnostic value of 1.5-T MRI in carriers of conventional pacemaker (cPM) or conventional implantable defibrillator (cICD). METHODS: We prospectively compared cPM/cICD-carriers undergoing MRI (study group, SG), excluding those device-dependent or implanted <6 weeks before enrolment or prior to 01/01/2000, with cPM/cICD-carriers undergoing chest x-ray, CT or follow-up (reference group, RG). RESULTS: 142 MRI (55 cardiac) were performed in 120 patients with cPM (n=71) or cICD (n=71). In the RG 98 measurements were performed in 95 patients with cPM (n=40) or cICD (n=58). No adverse events were observed. No MRI prolonged/interrupted. All cPM/cICD were correctly reprogrammed after MRI without malfunctions. One temporary communication failure was observed in one cPM-carrier. Immediately after MRI, 12/14 device interrogation parameters did not change significantly (clinically negligible changes of battery voltage and cICD charging time), without significant variations for SG versus RG. Three-12 months after MRI, 9/11 device interrogation parameters did not change significantly (clinically negligible changes of battery impedance/voltage). Non-significant changes of three markers of myocardial necrosis. Non-cardiac MRI: 82/87 diagnostic without artefacts; 4/87 diagnostic with artefacts; 1/87 partially diagnostic. Cardiac MRI: in cPM-carriers, 14/15 diagnostic with artefacts, 1/15 partially diagnostic; in cICD-carriers, 9/40 diagnostic with artefacts, 22 partially diagnostic, nine non-diagnostic. CONCLUSIONS: A favourable risk-benefit ratio of 1.5-T MRI in cPM/cICD carriers was reported. KEY POINTS: ⢠Cooperation between radiologists and cardiac electrophysiologists allowed safe 1.5-T MRI in cPM/cICD-carriers. ⢠No adverse events for 142 MRI in 71 cPM-carriers and 71 cICD-carriers. ⢠Ninety-nine per cent (86/87) of non-cardiac MRI in cPM/cICD-carriers were diagnostic. ⢠All cPM-carrier cardiac MRIs had artefacts, 14 examinations diagnostic, 1 partially diagnostic. ⢠Twenty-three per cent (9/40) of cardiac MRI in cICD-carriers were non-diagnostic.