1.
Phys Rev E Stat Nonlin Soft Matter Phys ; 71(4 Pt 1): 041503, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15903673

RESUMO

The viscosity near the critical point in nitrobenzene+hexane and nitrobenzene+heptane binary systems was studied by examining the viscosity values for critical mixtures at a variable temperature as obtained with a falling-ball viscometer. The regular part of the viscosity of the critical mixtures was calculated by interpolating measurements made at noncritical concentrations. Because viscosity anomaly studies must be conducted at zero shear, a method allowing the estimation of the effective shear for this type of viscometer was developed with a view to introducing the corrections required. This methodology was used to determine the critical exponent for the viscosity anomaly in nitrobenzene+hexane and nitrobenzene+heptane systems, which were found to be 0.0422+/-0.0004 and 0.0432+/-0.0013 , respectively, very consistent with the accepted value: 0.043.