Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 84
Filtrar
1.
J Am Coll Cardiol ; 27(5): 1090-7, 1996 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-8609326

RESUMO

OBJECTIVES: We compared the efficacy of two different mapping techniques in identifying the ablation site for atrial tachycardia. Moreover, we evaluated the additive positive predictive value of mechanical interruption of atrial tachycardia to reduce the number of ineffective radiofrequency applications. BACKGROUND: Radiofrequency catheter ablation has been suggested as a highly effective technique to treat drug-resistant atrial tachycardia. However, irrespective of the mapping technique utilized, success was most often achieved with a large number of radiofrequency applications. METHODS: Forty-five patients with atrial tachycardia underwent radiofrequency catheter ablation. Mapping techniques included identification of earliest atrial activation and pace-mapping concordant sequence. RESULTS: Atrial tachycardia was successfully treated in 42 (93.3%) of 45 patients with a mean of 3.9 radiofrequency pulses/patient. An interval between the onset of the intracavitary atrial deflection and the onset of the P wave during atrial tachycardia (AP interval) > or = 30 ms (p < 0.001) and pace-mapping concordant sequence (p = 0.01) were all significant predictors of outcome. An AP interval > or = 30 ms and a pace-mapping concordant sequence were highly sensitive (92.8%, 95% confidence interval [CI] 80.5% to 98.5%; 85.7%, 95% CI 71.5% to 94.6%, respectively) but less specific (47.8%, 95% CI 37.9% to 58.2%, 36.8%, 95% CI 27.6% to 47.2%, respectively) in identifying the site of ablation. By using atrial tachycardia mechanical interruption combined with the AP interval >30 ms or the pace-mapping concordant sequence, we obtained a specifically of 76.5% (95% CI 66.4% to 84.0%) and 73.5% (95% CI 63.2% to 81.4%), respectively, and a positive predictive value of 49.2% and 44.6%, respectively. CONCLUSIONS: An AP interval > or = 30 ms and a pace-mapping concordant sequence were reliable mapping features for predicting the outcome of the ablation procedure. Mechanical interruption of atrial tachycardia improved the specificity and positive predictive value of these two mapping techniques.


Assuntos
Ablação por Cateter/métodos , Taquicardia Supraventricular/cirurgia , Adolescente , Adulto , Criança , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Taquicardia Supraventricular/fisiopatologia
2.
Atherosclerosis ; 73(2-3): 241-6, 1988 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-3190821

RESUMO

Serum lipoprotein composition was examined in 18 male patients (mean age 44 +/- 0.9 years) who had undergone coronary artery by-pass surgery because of premature coronary heart disease (PCHD) and in 18 control subjects, matched with patients for sex, age, body mass index and serum cholesterol and triglyceride. Cholesterol, triglyceride and apolipoprotein B (apo B) concentrations in very low density lipoprotein (VLDL) and in low density lipoprotein (LDL) did not differ in the two groups, but high density lipoprotein (HDL)-cholesterol was significantly lower in PCHD patients (P less than 0.02). Cholesterol/apo B, triglyceride/apo B and phospholipid/apo B ratios in VLDL were significantly higher in patients than in controls (P less than 0.05, P less than 0.01 and P less than 0.001, respectively). The relative VLDL enrichment in cholesterol was mainly due to the non-esterified moiety (P less than 0.01). These VLDL abnormalities as well as the low HDL-cholesterol suggest an impairment of VLDL catabolism in PCHD patients.


Assuntos
Doença das Coronárias/sangue , Lipídeos/sangue , Lipoproteínas/sangue , Adulto , Fatores Etários , Colesterol/sangue , Ésteres do Colesterol/sangue , Humanos , Masculino , Pessoa de Meia-Idade , Fosfolipídeos/sangue , Triglicerídeos/sangue
3.
Ann Thorac Surg ; 31(5): 478-9, 1981 May.
Artigo em Inglês | MEDLINE | ID: mdl-7013720

RESUMO

A simple device created to prevent the entanglement of sutures with the struts of a bioprosthesis in the mitral position is presented. The technique appears to be effective, safe for the valve cusps, and easy to employ.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas/métodos , Valva Mitral/cirurgia , Técnicas de Sutura , Humanos , Complicações Pós-Operatórias/prevenção & controle
4.
Ann Thorac Surg ; 32(6): 602-3, 1981 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-7316593

RESUMO

Two patients experienced an episode of massive air embolism during extracorporeal circulation. Several emergency measures were taken. (1) The roller pump was reversed to take out air from the aorta. (2) The circuit was disconnected and recirculated to eliminate air bubbles. (3) Perfusion was restarted and the patient cooled to 24 degrees C for 40 minutes. (4) Pentothal (thiopental), steroids, and assisted ventilation were administered. The outcome was favorable in both patients, and there were no neurological sequelae. Immediate cooling and prolonged circulation seem to be a satisfactory approach to this problem.


Assuntos
Circulação Assistida , Ponte Cardiopulmonar/efeitos adversos , Embolia Aérea/terapia , Hipotermia Induzida , Adulto , Embolia Aérea/etiologia , Feminino , Humanos , Complicações Intraoperatórias , Metilprednisolona/uso terapêutico , Pessoa de Meia-Idade , Respiração Artificial , Tiopental/uso terapêutico
5.
Ann Thorac Surg ; 72(3): 768-74; discussion 775, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11565656

RESUMO

BACKGROUND: The aim of this study was to compare hospital, early, and late clinical outcomes for patients undergoing one-stage, coronary and abdominal aortic surgical intervention with and without cardiopulmonary bypass. METHODS: From March 1990 to September 1999, 42 consecutive patients underwent combined operations at a single institution. Cardiopulmonary bypass and cardioplegic arrest were used during coronary revascularization in the first 20 patients (on-pump group), and the next 22 patients received the one-stage operations on the beating heart (off-pump group). RESULTS: Baseline characteristics were similar between groups. Three cardiac-related hospital deaths occurred in the on-pump group and one such death in the off-pump group (p = 0.25). Cardiac-related events, pulmonary complications, inotropic support, blood loss and transfusion requirements, intensive care unit stay, and hospital stay were significantly reduced in the off-pump group (all, p < 0.05). The actuarial survival rates in the on-pump and off-pump groups were 80% and 95%, respectively, at 1 year (p = 0.13) and 75% and 89%, respectively, at 3 years (p = 0.22). Freedom from cardiac-related events at 1-year follow-up was 91% in the off-pump group and 65% in the on-pump group (p < 0.05). No difference in cardiac-related events between groups was observed at 3 years. CONCLUSIONS: Off-pump coronary surgical procedures decrease postoperative complications in high-risk patients undergoing simultaneous coronary and abdominal aortic operations compared with the conventional one-stage procedure. The early benefits achieved with off-pump surgical intervention are not at the expense of the long-term clinical outcome.


Assuntos
Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Ponte Cardiopulmonar , Ponte de Artéria Coronária , Doença das Coronárias/cirurgia , Idoso , Aneurisma da Aorta Abdominal/complicações , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/mortalidade , Ponte Cardiopulmonar/efeitos adversos , Ponte de Artéria Coronária/efeitos adversos , Doença das Coronárias/complicações , Feminino , Seguimentos , Parada Cardíaca Induzida , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Complicações Pós-Operatórias/mortalidade , Estudos Retrospectivos , Taxa de Sobrevida
6.
Ann Thorac Surg ; 63(3): 683-8, 1997 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-9066384

RESUMO

BACKGROUND: Left ventricular dysfunction is frequently observed in patients after hypothermic cardioplegic arrest, and often inotropic intervention is necessary for patients to be successfully weaned from cardiopulmonary bypass (CPB). A myocardial beta-adrenergic receptor (beta AR) desensitization has been noted to occur after hypothermic CPB in patients undergoing coronary artery bypass grafting. This randomized study was undertaken to determine the effect of cardioplegic solution temperature on cardiac beta ARs. METHODS: Two groups of patients (20 patients in each) scheduled for elective coronary artery bypass grafting underwent CPB with either intermittent warm or cold blood cardioplegia. The density of the beta ARs, the proportion of beta 1- to beta 2-adrenergic receptors, and the beta AR coupling capacity to adenylate cyclase were determined in specimens of the right atrial tissue at baseline, during CPB, and after discontinuation of CPB. Plasma concentrations of catecholamines were also measured in both arterial and coronary sinus samples. RESULTS: In both cardioplegia groups, no significant modification in either the beta AR density or the proportion of beta 1- to beta 2-adrenergic receptors was detected. However, a significant decrease in adenylate cyclase activity after stimulation with isoproterenol was observed in the cold blood cardioplegia group during CPB (p < 0.01) and 30 minutes after its discontinuation (p < 0.05). Moreover, a significant decrease in adenylate cyclase activity during CPB was detected in this group after stimulation with sodium fluoride (p < 0.05), but this pattern was found to be completely reversed by 30 minutes after discontinuation of CPB. No modification in the basal or stimulated adenylate cyclase activity was observed in the warm blood cardioplegia group during or after CPB. CONCLUSIONS: Our results confirm the finding from previous studies of a cardiac beta AR desensitization after hypothermic cardioplegic arrest, and provide evidence of the advantages of intermittent warm blood cardioplegia in preserving the autonomic sympathetic function of the heart.


Assuntos
Ponte de Artéria Coronária/métodos , Parada Cardíaca Induzida/métodos , Coração/inervação , Receptores Adrenérgicos beta/fisiologia , Adenilil Ciclases/metabolismo , Sangue , Epinefrina/sangue , Feminino , Átrios do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio/enzimologia , Norepinefrina/sangue , Temperatura
7.
Ann Thorac Surg ; 66(6 Suppl): S68-72, 1998 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-9930420

RESUMO

BACKGROUND: Following bioprosthetic failure, replacement is usually done with mechanical valves to avoid repeated reoperations. METHODS: From 1986 to 1996 we operated on 130 patients with bioprosthetic failure, implanting a new bioprosthesis; this group included patients with contraindication to anticoagulation, tricuspid replacement, and specific patient requests. Mean age was 63+/-8 years. RESULTS: The perioperative mortality was 13.8%. At 10 year follow-up the actuarial estimate of survival was 77.4%+/-6.6%. Freedom from structural valve deterioration was estimated at 81.8%+/-6.3%. Freedom from a third operation was estimated at 85.5%+/-5.2%. No patient was permanently anticoagulated. Freedom from thromboembolism was estimated at 91.5%+/-4%, and there were no hemorrhages. Freedom from cardiac-related deaths was estimated at 85.7%+/-5%. CONCLUSIONS: This group of patients received the first valve between 1976 and 1986; the range of the cumulative follow-up reaches 20 years, and the extended survival compares favorably with survival of mechanical valves.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Análise Atuarial , Anticoagulantes , Bioprótese/efeitos adversos , Contraindicações , Morte Súbita Cardíaca/etiologia , Feminino , Seguimentos , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Participação do Paciente , Hemorragia Pós-Operatória/etiologia , Modelos de Riscos Proporcionais , Desenho de Prótese , Falha de Prótese , Reoperação , Fatores de Risco , Taxa de Sobrevida , Tromboembolia/etiologia , Valva Tricúspide/cirurgia
8.
Ann Thorac Surg ; 58(5): 1427-32, 1994 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-7979670

RESUMO

To evaluate the effect of coenzyme Q10 in reducing postoperative cardiac complications after ischemia and reperfusion, we randomly divided 40 patients undergoing elective coronary artery bypass into two groups: patients in group 1 received coenzyme Q10 (150 mg/day) for 7 days before operation, and those in group 2 were the control group. Concentrations of thiobarbituric acid-reactive substances (malondialdehyde), conjugated dienes, and cardiac isoenzymes of creatine kinase were measured in samples from both arterial and coronary sinus sites. Serial sampling was performed 5 minutes after heparin administration, at 10 and 30 minutes during cardiopulmonary bypass, 15 and 30 minutes after aortic cross-clamp removal, and 5 minutes after protamine administration. The concentrations of malondialdehyde, conjugated dienes, and creatine kinase in group 1 were significantly lower than those in group 2. The decrease in plasma malondialdehyde concentrations correlated positively with the decrease in creatine kinase levels in the coronary sinus. The treatment group showed a significantly lower incidence of ventricular arrhythmias during the recovery period than did the control group (p < 0.05). Although the percentage of patients requiring inotropic agents was not significantly different between the two groups, the mean dosage of dopamine required to maintain stable hemodynamics was significantly lower in patients of group 1 than in those of group 2 (p < 0.01). Our findings suggest that pretreatment with coenzyme Q10 may play a protective role during routine bypass grafting by attenuating the degree of peroxidative damage.


Assuntos
Ponte de Artéria Coronária , Traumatismo por Reperfusão Miocárdica/prevenção & controle , Ubiquinona/análogos & derivados , Coenzimas , Creatina Quinase/sangue , Feminino , Frequência Cardíaca/efeitos dos fármacos , Hemodinâmica/efeitos dos fármacos , Humanos , Isoenzimas , Peroxidação de Lipídeos , Masculino , Malondialdeído/sangue , Pessoa de Meia-Idade , Traumatismo por Reperfusão Miocárdica/metabolismo , Substâncias Reativas com Ácido Tiobarbitúrico , Ubiquinona/uso terapêutico
9.
Int J Cardiol ; 48(3): 219-24, 1995 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-7782134

RESUMO

Prosthetic cardiac thrombosis is a life-threatening complication that needs prompt diagnosis and therapy. We used recombinant tissue-type plasminogen activator (rT-PA), followed by heparin, in three patients with mitral prosthetic thrombosis, which was evident in two and suspect in one. Transthoracic and transesophageal echocardiography were employed in the diagnosis of both thrombosis and its resolution. No complications occurred. Immediately after the end of treatment with rT-PA, clinical status and echocardiographic data improved in all cases: transthoracic echocardiography showed the normalization of prosthetic function and transesophageal echocardiography showed resolution of thrombosis. One patient needed reoperation for rethrombosis due to the presence of prosthetic fibrous clot. rT-PA, followed by heparin, led to a good clinical result without bleeding and embolic complications in selected patients with mitral prosthetic thrombosis. Transthoracic and transesophageal echocardiography are complementary diagnostic tools in the diagnosis and management of patients with prosthetic thrombosis.


Assuntos
Ecocardiografia Doppler , Ecocardiografia Transesofagiana , Próteses Valvulares Cardíacas/efeitos adversos , Trombose/diagnóstico por imagem , Trombose/tratamento farmacológico , Ativador de Plasminogênio Tecidual/uso terapêutico , Adulto , Idoso , Feminino , Heparina/uso terapêutico , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral , Trombose/etiologia
10.
Eur J Cardiothorac Surg ; 18(4): 453-7, 2000 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11024384

RESUMO

OBJECTIVE: Redo operations for bioprosthesis malfunction can sometimes be technically very demanding and cardiac structures may be damaged. Excising only the leaflets of the damaged bioprosthesis and leaving the old ring in situ on which the 'new' mechanical valve is sutured can, in very selected cases, represent a solution. METHODS: Twenty-two patients were operated on, with the valve-on-valve technique, from September 1991 through December 1992. There were three operative deaths. RESULTS: The surviving 19 patients were followed-up from 83 to 98 months (mean 90.5 months.). There were two late deaths. The patients were examined clinically and with transthoracic and transesophageal echocardiograms. All patients were in good condition and the echocardiographic examinations showed no clinically important gradients across the prostheses. CONCLUSIONS: The valve-on-valve technique, in certain difficult situations, can give successful mid-term results.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Falha de Prótese , Adulto , Idoso , Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Reoperação , Resultado do Tratamento
11.
Eur J Cardiothorac Surg ; 7(10): 507-10, 1993.
Artigo em Inglês | MEDLINE | ID: mdl-8267989

RESUMO

Removal of a failing bioprosthesis can be a delicate operation and extensive damage can be caused. Eighteen patients with failing bioprostheses underwent excision of the leaflets, then the "new" mechanical valve was sewn onto the "old" bioprosthetic ring. At follow-up, clinical and 2D color-flow echo-Doppler evaluations showed good hemodynamic performance of the mechanical valves.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas/métodos , Adulto , Idoso , Valva Aórtica , Ecocardiografia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral , Falha de Prótese , Reoperação , Valva Tricúspide
12.
Eur J Cardiothorac Surg ; 5(8): 414-7; discussion 418, 1991.
Artigo em Inglês | MEDLINE | ID: mdl-1716932

RESUMO

Bleeding after open heart surgery is still a great concern for the surgeon, especially when the surgical field has been revised accurately and hemostatic stitches and electrical cauterization have been used extensively. Among non-surgical adjuncts, aprotinin has been reported as very effective in reducing complications. At the time we started using this drug, we intended to test two different dosages lower than those reported in the literature. We evaluated three groups of 18 patients: the first (A) received about 350 mg of aprotinin from the start of anesthesia up to the end of operation (140 mg in the priming of cardio-pulmonary bypass and 70 mg/h i.v. during the procedure; the second (A/2) received half that dose (i.e. 70 mg and 35 mg, respectively), and the third (C) did not receive aprotinin. We compared in these groups: postoperative bleeding, blood transfusions, red blood cells, hemoglobin, hematocrit, platelets. The results were good only in the A group: bleeding was reduced and few transfusions were required. The patients in the A/2 and C groups did not show significant differences. From our observations we conclude that aprotinin is a useful adjunct, but has to be given in the proper dose.


Assuntos
Aprotinina/administração & dosagem , Perda Sanguínea Cirúrgica/prevenção & controle , Procedimentos Cirúrgicos Cardíacos , Aprotinina/uso terapêutico , Transfusão de Sangue , Estudos de Avaliação como Assunto , Circulação Extracorpórea , Humanos , Reoperação , Fatores de Tempo
13.
J Cardiovasc Pharmacol Ther ; 6(2): 121-7, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11509918

RESUMO

BACKGROUND: The hypothesis that intravenous L-arginine infusion improves the vasodilatory response to ischemia in the resistance vessels of human lower limbs in relatively young coronary heart disease patients taking vasodilating drugs was tested. METHODS: Twenty patients with onset of symptoms of coronary artery disease before age 50, operated for aortocoronary bypass and taking vasodilating drugs, were compared with 20 control subjects of comparable age and gender; neither group included heavy smokers (>10 cigarettes/day). Blood flow in the lower limbs was measured noninvasively with strain-gauge plethysmography, both at rest and during a reactive hyperemia test. Intravenous infusion of L-arginine was performed in nine coronary heart disease patients and in nine control subjects. RESULTS: Resting blood flow to the lower limbs was 2.3 mL/min/100 mL in control subjects vs 3.4 mL/min/100 mL in patients (difference not statistically significant). Peak blood flow measured after a 3-minute arterial occlusion was 24.0 mL/min/100 mL in control subjects vs 20.3 mL/min/100 mL in coronary heart disease patients (P<0.05). Peripheral minimal vascular resistances were 4.28 and 5.46 peripheral resistances units (p.r.u.) in control subjects and patients, respectively (P<0.05). Intravenous infusion of L-arginine was followed by increased resting blood flow in cases and controls (P=0.009), with a parallel reduction in peripheral resting vascular resistances (P=0.009). Coronary heart disease patients showed increased peak blood flow (P=0.04) and reduced minimal vascular resistances (P=0.02), whereas no statistically significant changes in these parameters were detectable in control subjects. Intravenous glucose infusion, leading to increased serum insulin concentration, did not modify any hemodynamic parameter. CONCLUSIONS: Hemodynamic responses in the skeletal muscle are impaired during a reactive hyperemia test in relatively young coronary heart disease patients taking vasodilating drugs. Intravenous L-arginine infusion corrects the impaired vasodilatory response of the lower limbs to an acute increase in flow following a cuff thigh occlusion.


Assuntos
Arginina/farmacologia , Doença das Coronárias/fisiopatologia , Vasodilatação/efeitos dos fármacos , Adulto , Idoso , Arginina/uso terapêutico , Doença das Coronárias/tratamento farmacológico , Glucose/farmacologia , Hemodinâmica/efeitos dos fármacos , Humanos , Hiperemia/tratamento farmacológico , Infusões Intravenosas , Insulina/metabolismo , Secreção de Insulina , Isquemia/tratamento farmacológico , Perna (Membro)/irrigação sanguínea , Pessoa de Meia-Idade , Fluxo Sanguíneo Regional/efeitos dos fármacos , Descanso/fisiologia , Resistência Vascular/efeitos dos fármacos , Vasodilatadores/uso terapêutico
14.
J Cardiovasc Surg (Torino) ; 29(1): 100-2, 1988.
Artigo em Inglês | MEDLINE | ID: mdl-3257495

RESUMO

In coronary artery surgery, when a poor distal run of can predict an early graft failure, it might be useful to perform the last anastomosis to a low pressure chamber thus creating a small arterio-venous (A-V) fistula. From January throughout December 1984, 4 patients underwent coronary angiography for severe symptoms of angina. The coronary angiography showed multiple stenoses on the left anterior descending (LAD), ventricular branches of the circumflex (CX), and posterior descending of the right coronary artery (PD). At operation the patients received a sequential aortocoronary bypass graft with reversed saphenous vein, plus the creation of a small A-V fistula into the right atrium in order to improve the graft flow and patency. All patients experienced a clinical improvement. No adverse effects have been observed and the patients, controlled clinically with non invasive and in two cases with invasive techniques, showed satisfactory revascularization.


Assuntos
Derivação Arteriovenosa Cirúrgica/métodos , Ponte de Artéria Coronária/métodos , Angina Pectoris/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Veia Safena/cirurgia
15.
J Cardiovasc Surg (Torino) ; 39(1): 103-5, 1998 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9537544

RESUMO

The authors describe a simple method to perform left ventricular biopsies during open heart surgery. An automatic gun shaped device is used by one hand of the surgeon: the sample is obtained in a few seconds, at any time of the surgical procedure. It consists of a transmural piece of tissue, averaging 18 mm3 in quantity. The device has been used in 20 patients who underwent coronary artery revascularization. All the biopsies were successful. No complications occurred.


Assuntos
Biópsia por Agulha/instrumentação , Biópsia por Agulha/métodos , Ponte de Artéria Coronária , Miocárdio/patologia , Humanos , Cuidados Intraoperatórios
16.
J Cardiovasc Surg (Torino) ; 16(3): 308-14, 1975.
Artigo em Inglês | MEDLINE | ID: mdl-1150738

RESUMO

Two cases of aneurysmatic vascular lesions (a large cranio-encephalic angiodysplasia with arterio-venous communications and a post-traumatic aneurysm of the vertebral artery) are reported; both were of a very difficult surgical approach and were successfully treated with the use of extra-corporeal circulation. The partial cardiopulmonary bypass, with femoro-femoral cannulation, allowed complete recovery of the lost blood, controlled hypotension, and a certain degree of hypothermia. These factors were decisive for the good outcome of the operations.


Assuntos
Aneurisma/cirurgia , Malformações Arteriovenosas/cirurgia , Ponte Cardiopulmonar , Circulação Extracorpórea , Adulto , Aneurisma/etiologia , Angiografia , Pressão Sanguínea , Transfusão de Sangue Autóloga , Lesões das Artérias Carótidas , Pressão Venosa Central , Eletrocardiografia , Feminino , Hemostasia/métodos , Humanos , Hipotensão Controlada , Hipotermia Induzida , Masculino , Artéria Vertebral
17.
J Cardiovasc Surg (Torino) ; 28(1): 98-9, 1987.
Artigo em Inglês | MEDLINE | ID: mdl-3543021

RESUMO

An unusual complication of the median sternotomy is reported. A 37-year-old male experienced a left innominate vein thrombosis 20 months after surgery. The combined treatment consisting of local infusion with Urokinase, surgical removal of the wire and balloon catheter dilatation, was completely successful.


Assuntos
Veias Braquiocefálicas , Doenças das Valvas Cardíacas/cirurgia , Complicações Pós-Operatórias , Esterno/cirurgia , Trombose/etiologia , Adulto , Humanos , Masculino , Fatores de Tempo
18.
J Cardiovasc Surg (Torino) ; 32(6): 800-6, 1991.
Artigo em Inglês | MEDLINE | ID: mdl-1752903

RESUMO

Prosthetic valve endocarditis (PVE) remains an uncommon but serious complication of cardiac valve replacement. We analysed several risk factors (active or healed, early or late endocarditis, congestive heart failure, arterial emboli etc.) in order to identify the factors which may predict bad outcome. The overall mortality rate was 46.8% (15/32 patients). There was a significantly higher mortality rate in patients with early endocarditis (80%) than in those with late endocarditis (38%) (p less than 0.01). In the group of patients who underwent reoperation, the mortality rate was higher in those with active endocarditis (70%) than in those with healed endocarditis (28.5%) (p less than 0.05). We believe that combined medical and surgical treatment is the best management for bioprosthetic valve endocarditis, with the institution of appropriate preoperative antibiotic therapy, to attempt to achieve sterilization.


Assuntos
Bioprótese , Endocardite Bacteriana/mortalidade , Próteses Valvulares Cardíacas/efeitos adversos , Infecções Relacionadas à Prótese/mortalidade , Adulto , Antibacterianos , Valva Aórtica , Terapia Combinada , Quimioterapia Combinada/uso terapêutico , Endocardite Bacteriana/terapia , Feminino , Humanos , Masculino , Valva Mitral , Pré-Medicação , Prognóstico , Infecções Relacionadas à Prótese/terapia , Reoperação , Fatores de Risco
19.
J Cardiovasc Surg (Torino) ; 24(2): 172-4, 1983.
Artigo em Inglês | MEDLINE | ID: mdl-6841441

RESUMO

A case with marked factor VII deficiency, undergoing open heart surgery for atrial myxoma, is reported. The syndrome was unknown to the patient and only pre-operative routine coagulation studies showed a low prothrombin activity (22%). Further investigations revealed a severe factor VII deficiency. The operation was carried out under factor VII concentrate administration and no bleeding complication occurred.


Assuntos
Deficiência do Fator VII/complicações , Neoplasias Cardíacas/cirurgia , Mixoma/cirurgia , Fator VII/administração & dosagem , Átrios do Coração/cirurgia , Neoplasias Cardíacas/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Mixoma/complicações , Cuidados Pós-Operatórios , Cuidados Pré-Operatórios
20.
J Cardiovasc Surg (Torino) ; 43(2): 251-4, 2002 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11887065

RESUMO

We report the development of two anastomotic pseudoaneurysms in a patient with Behçet's disease eighteen months after abdominal aortic aneurysm repair. Major asymptomatic vascular complications should be suspected in patients with Behçet's disease with a history of vascular surgery and treated expediently due to the risk of rupture. Magnetic resonance angiography, contrast-enhanced computed tomography or ultrasound scanning should be performed at least every 6 months after vascular surgery.


Assuntos
Falso Aneurisma/diagnóstico , Aneurisma da Aorta Abdominal/cirurgia , Síndrome de Behçet/complicações , Complicações Pós-Operatórias/diagnóstico , Adulto , Anastomose Cirúrgica , Falso Aneurisma/cirurgia , Prótese Vascular , Implante de Prótese Vascular , Seguimentos , Humanos , Angiografia por Ressonância Magnética , Masculino , Politetrafluoretileno , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA