RESUMO
BACKGROUND: Measurement of the common bile duct (CBD) is considered a fundamental component of biliary point-of-care ultrasound (POCUS), but can be technically challenging. OBJECTIVE: The primary objective of this study was to determine whether CBD diameter contributes to the diagnosis of complicated biliary pathology in emergency department (ED) patients with normal laboratory values and no abnormal biliary POCUS findings aside from cholelithiasis. METHODS: We performed a prospective, observational study of adult ED patients undergoing POCUS of the right upper quadrant (RUQ) and serum laboratory studies for suspected biliary pathology. The primary outcome was complicated biliary pathology occurring in the setting of normal laboratory values and a POCUS demonstrating the absence of gallbladder wall thickening (GWT), pericholecystic fluid (PCF) and sonographic Murphy's sign (SMS). The association between CBD dilation and complicated biliary pathology was assessed using logistic regression to control for other factors, including laboratory findings, cholelithiasis and other sonographic abnormalities. RESULTS: A total of 158 patients were included in the study. 76 (48.1%) received non-biliary diagnoses and 82 (51.9%) were diagnosed with biliary pathology. Complicated biliary pathology was diagnosed in 39 patients. Sensitivity of CBD dilation for complicated biliary pathology was 23.7% and specificity was 77.9%. CONCLUSION: Of patients diagnosed with biliary pathology, none had isolated CBD dilatation. In the absence of abnormal laboratory values and GWT, PCF or SMS on POCUS, obtaining a CBD measurement is unlikely to contribute to the evaluation of this patient population.
Assuntos
Coledocolitíase/diagnóstico , Ducto Colédoco/diagnóstico por imagem , Serviço Hospitalar de Emergência , Testes Imediatos , Ultrassonografia/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto JovemRESUMO
OBJECTIVES: The established benefits of point-of-care ultrasound have given rise to multiple new and innovative curriculums to incorporate ultrasound teaching into medical education. This study sought to measure the educational success of a comprehensive and integrated 4-year point-of-care ultrasound curriculum. METHODS: We integrated a curriculum consisting of traditional didactics combined with asynchronous learning modules and hands-on practice on live models with skilled sonographers into all 4 years of education at a Liaison Committee on Medical Education-accredited US Medical School. Each graduating student was administered an exit examination with 48 questions that corresponded to ultrasound milestones. RESULTS: Ninety-five percent (n = 84) of fourth-year medical students completed the exit examination. The mean score was 79.5% (SD, 10.2%), with mean scores on the ultrasound physics and anatomy subsections being 77.1% (SD, 11.0%) and 85.9% (SD, 21.0%), respectively. CONCLUSIONS: A comprehensive 4-year point-of-care ultrasound curriculum integrated into medical school may successfully equip graduating medical students with a fundamental understanding of ultrasound physics, anatomy, and disease recognition.
Assuntos
Currículo , Educação de Graduação em Medicina/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Faculdades de Medicina , Ultrassom/educação , Acreditação , Competência Clínica , Estudos Transversais , HumanosRESUMO
Introduction: Lectures are a standard aspect across all realms of medical education. Previous studies have shown that visual design of presentation slides can affect learner outcomes. The purpose of this study was to develop a slide design rubric grounded in evidence-based, multimedia principles to enable objective evaluation of slide design. Method: Using the principles described in Mayers' Principles of Multimedia Learning and Duarte's Slide:ology, the authors extracted nineteen items important for slide design. We developed an online, rank-item, survey tool to identify the importance of each item among medical educators. Respondents selected which slide design principles they felt were important when attending a lecture/didactic session and ranked their relative importance. Results: We received 225 responses to the survey. When asked to specifically rank elements from most important to least important, participants gave the most weight to "readability of figures and data" and "[lack of] busy-ness of slide." The lowest ranked elements were "transitions and animations" and "color schemes". Using the results of the survey, including the free response, we developed a rubric with relative weighting that followed our survey data. Conclusion: With this information we have applied values to the various aspects of the rubric for a total score of 100. We hope that this rubric can be used for self-assessment or to evaluate and improve slides for educators. Future research will be focused on implementing and validating the slide design survey and ensuring it is easily usable with a high inter-rater reliability and whether self-assessment with the rubric improves presentation design and education quality.
RESUMO
INTRODUCTION: Retinal detachment is an ocular emergency that commonly presents to the emergency department (ED). Ophthalmologists are able to accurately make this diagnosis with a dilated fundoscopic exam, scleral depression or ophthalmic ultrasound when a view to the retina is obstructed. Emergency physicians (EPs) are not trained to examine the peripheral retina, and thus ophthalmic ultrasound can be used to aid in diagnosis. We assessed the accuracy of ocular point-of-care ultrasound (POCUS) in diagnosing retinal detachment. METHODS: We retrospectively reviewed charts of ED patients with suspected retinal detachment who underwent ocular POCUS between July 2012 and May 2015. Charts were reviewed for patients presenting to the ED with ocular complaints and clinical concern for retinal detachment. We compared ocular POCUS performed by EPs against the criterion reference of the consulting ophthalmologist's diagnosis. RESULTS: We enrolled a total of 109 patients. Of the 34 patients diagnosed with retinal detachment by the ophthalmologists, 31 were correctly identified as having retinal detachment by the EP using ocular POCUS. Of the 75 patients who did not have retinal detachment, 72 were ruled out by ocular POCUS by the EP. This resulted in a POCUS sensitivity of 91% (95% CI [76-98]) and specificity of 96% (95% CI [89-99]). CONCLUSION: This retrospective study suggests that ocular POCUS performed by EPs can aid in the diagnosis of retinal detachment in ED.