Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
1.
J Cardiothorac Vasc Anesth ; 29(5): 1155-61, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25998068

RESUMO

OBJECTIVE: Post-cardiopulmonary bypass biventricular pacing improves hemodynamics but without clearly defined predictors of response. Based on preclinical studies and prior observations, it was suspected that diastolic dysfunction or pulmonary hypertension is predictive of hemodynamic benefit. DESIGN: Randomized controlled study of temporary biventricular pacing after cardiopulmonary bypass. SETTING: Single-center study at university-affiliated tertiary care hospital. INTERVENTIONS: Patients who underwent bypass with preoperative ejection fraction ≤40% and QRS duration ≥100 ms or double-valve surgery were enrolled. At 3 time points between separation from bypass and postoperative day 1, pacing delays were varied to optimize hemodynamics. PARTICIPANTS: Data from 43 patients were analyzed. MEASUREMENTS AND MAIN RESULTS: Cardiac output and arterial pressure were measured under no pacing, atrial pacing, and biventricular pacing. Preoperative echocardiograms and pulmonary artery catheterizations were reviewed, and measures of both systolic and diastolic function were compared to hemodynamic response. Early after separation, improvement in cardiac output was positively correlated with pulmonary vascular resistance (R(2) = 0.97, p<0.001), ventricle wall thickness (R(2) = 0.72, p = 0.002)), and E/e', a measure of abnormal diastolic ventricular filling velocity (R(2) = 0.56, p = 0.04). Similar trends were seen with mean arterial pressure. QRS duration and ejection fraction did not correlate significantly with improvements in hemodynamics. CONCLUSIONS: There may be an effect of biventricular pacing related to amelioration of abnormal diastolic filling patterns rather than electrical resynchronization in the postoperative state.


Assuntos
Terapia de Ressincronização Cardíaca , Ventrículos do Coração/fisiopatologia , Hipertensão Pulmonar/complicações , Hipertensão Pulmonar/fisiopatologia , Complicações Pós-Operatórias/diagnóstico , Disfunção Ventricular/complicações , Idoso , Estudos Cross-Over , Diástole , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/fisiopatologia , Disfunção Ventricular/fisiopatologia
2.
J Cardiothorac Vasc Anesth ; 28(1): 31-35, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24055281

RESUMO

OBJECTIVES: Effects of temporary biventricular pacing after cardiopulmonary bypass are unpredictable, and the utility of speckle-tracking echocardiography in this setting is unclear. Accordingly, speckle-tracking analysis of transgastric echocardiograms taken during cardiac surgery was assessed as a potential tool to measure strain, synchrony, and twist as indices to predict response. DESIGN: Prospective observational study, in part, with a randomized controlled study of temporary permanent biventricular pacing after cardiopulmonary bypass. SETTING: Single-center study at university-affiliated tertiary care hospital. PARTICIPANTS: Twenty-one cardiac surgery candidates with ejection fraction ≤40% and QRS duration ≥100 ms or who were undergoing double-valve surgery. INTERVENTIONS: Transgastric views of the basal, midpapillary, and apical levels of the left ventricle were acquired before and after bypass. MEASUREMENTS AND MAIN RESULTS: Midpapillary sections were analyzable in 38% of patients. The remainder had epicardial borders extending beyond the field of view (24%) or inadequate image quality (38%). Only 9% of basal or apical sections were analyzable. Midpapillary radial strain and synchrony changed insignificantly after bypass. Variation in fractional area change correlated with changes in radial strain (p = 0.041) but not with synchrony. CONCLUSIONS: Intraoperative transgastric echocardiography is inadequate for speckle-tracking analysis with current techniques. Intraoperative predictors of temporary biventricular pacing response are lacking.


Assuntos
Ponte Cardiopulmonar/efeitos adversos , Ecocardiografia/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Idoso , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Disfunção Ventricular Esquerda/etiologia
3.
Pediatr Cardiol ; 35(7): 1213-9, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24827078

RESUMO

Ventricular dyssynchrony is associated with morbidity and mortality after palliation of a single ventricle. The authors hypothesized that resynchronization with optimized temporary multisite pacing postoperatively would be safe, feasible, and effective. Pacing was assessed in the intensive care unit within the first 24 h after surgery. Two unipolar atrial pacing leads and four bipolar ventricular pacing leads were placed at standardized sites intraoperatively. Pacing was optimized to maximize mean arterial pressure. The protocol tested 11 combinations of the 4 different ventricular lead sites, 6 atrioventricular delays (50-150 ms), and 14 intraventricular delays. Optimal pacing settings were thus determined and ultimately compared in four configurations: bipolar, unipolar, single-site atrioventricular pacing, and intrinsic rhythm. Each patient was his or her own control, and all pacing comparisons were implemented in random sequence. Single-ventricle palliation was performed for 17 children ages 0-21 years. Pacing increased mean arterial pressure (MAP) versus intrinsic rhythm, with the following configurations: bipolar multisite pacing increased MAP by 2.2 % (67.7 ± 2.4 to 69.2 ± 2.4 mmHg; p = 0.013) and unipolar multisite pacing increased MAP by 2.8 % (67.7 ± 2.4 to 69.6 ± 2.7 mmHg; p = 0.002). Atrioventricular single-site pacing increased MAP by 2.1 % (67.7 ± 2.4 to 69.1 ± 2.5 mmHg: p = 0.02, insignificant difference under Bonferroni correction). The echocardiographic fractional area change in nine patients increased significantly only with unipolar pacing (32 ± 3.1 to 36 ± 4.2 %; p = 0.02). No study-related adverse events occurred. Multisite pacing optimization is safe and feasible in the early postoperative period after single-ventricle palliation, with improvements in mean arterial pressure and fractional area shortening. Further study to evaluate clinical benefits is required.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Sistema de Condução Cardíaco/fisiopatologia , Cardiopatias Congênitas/cirurgia , Ventrículos do Coração/anormalidades , Cuidados Pós-Operatórios/métodos , Taquicardia Ventricular/terapia , Adolescente , Criança , Pré-Escolar , Ecocardiografia , Eletrocardiografia , Feminino , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Lactente , Recém-Nascido , Masculino , Cuidados Paliativos , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Adulto Jovem
4.
J Surg Res ; 185(2): 645-52, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23890399

RESUMO

BACKGROUND: Biventricular pacing (BiVP) improves cardiac output (CO) in selected cardiac surgery patients, but response remains variable, necessitating a better understanding of the mechanism. Accordingly, we used speckle tracking echocardiography (STE) to analyze BiVP during acute right ventricular pressure overload (RVPO). MATERIALS AND METHODS: In nine pigs, the inferior vena cava (IVC) was snared to decrease CO and establish a control model. Heart block was induced, the pulmonary artery snared, and BiVP initiated. Echocardiograms of the left ventricular midpapillary level were taken at varying atrioventricular delay (AVD) and interventricular delay (VVD) for STE analysis of regional circumferential strain (CS) and radial strain (RS). Echocardiograms were taken of the left ventricular base, midpapillary, and apex during baseline, IVC occlusion, and each BiVP setting for STE analysis of twist, apical and basal rotations, CS, RS, and synchrony. Indices were correlated against CO with mixed linear models. RESULTS: During IVC occlusion, CO correlated with twist, apical rotation, RS, RS synchrony, and CS (P < 0.05). During RVPO with BiVP, CO only correlated with RS synchrony and CS (P < 0.05). During AVD and VVD variations, CO was associated with free wall RS (P < 0.008). CO correlated with septal wall CS during AVD variation and free wall CS during VVD variation (P < 0.008). CONCLUSIONS: In an open chest model, twist, RS, RS synchrony, and CS analyzed by STE may be noninvasive surrogates for changes in CO. During RVPO, changes in RS synchrony and CS with varying regional strain contributions may be the primary mechanism in which BiVP improves CO. Lack of correlation of remaining indices may reflect postsystolic function.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Bloqueio Cardíaco/fisiopatologia , Bloqueio Cardíaco/terapia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Animais , Débito Cardíaco/fisiologia , Modelos Animais de Doenças , Ecocardiografia/métodos , Bloqueio Cardíaco/diagnóstico por imagem , Insuficiência Cardíaca/diagnóstico por imagem , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/fisiopatologia , Hipertensão Pulmonar/terapia , Masculino , Contração Miocárdica/fisiologia , Suínos , Torção Mecânica , Veia Cava Inferior/fisiopatologia , Pressão Ventricular/fisiologia
5.
Pacing Clin Electrophysiol ; 36(6): 684-7, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23510059

RESUMO

BACKGROUND: Transtelephonic monitoring (TTM) of pediatric patients with cardiac pacemakers (PMs) has been shown to have high sensitivity and specificity in identifying PM malfunction. The objective of this study is to determine if there is a difference in the rate of abnormal TTM findings in transvenous versus epicardial PM systems. METHODS: Our TTM database was reviewed. Patients younger than 21 years of age enrolled for TTM between 1990 and 2010 were included. The abnormal TTM recordings (not including elective replacement indicator) were identified. Logistic regression was used for statistical analysis. Note that P < 0.05 was considered significant. RESULTS: We identified 186 patients. There were 75 (40%) epicardial systems. The mean age at TTM enrollment was 6.8 ± 5.9 years (2 months-20.2 years). There were 41 (22%) patients with abnormal TTM findings. The abnormalities were found in 23/75 (31%) epicardial and 18/111 (16%) transvenous systems (odds ratio [OR]: 2.3, 95% confidence interval [CI]: 1.13-4.62, P = 0.02). When controlling for age and presence of heart disease the OR for abnormal transmission in epicardial systems compared with transvenous was 2.1 (95% CI: 1.03-4.43, P = 0.04). Patients with epicardial systems were more likely to have capture abnormalities on TTM than transvenous systems (OR: 6.1, 95% CI: 1.9-19.5, P = 0.002). CONCLUSION: Pediatric patients with epicardial PM systems are more likely to have abnormal TTM test (particularly capture problems) than patients with transvenous systems regardless of age or presence of heart disease. Consequently, patients with epicardial PM systems should be followed closely with TTM.


Assuntos
Análise de Falha de Equipamento/estatística & dados numéricos , Falha de Equipamento/estatística & dados numéricos , Marca-Passo Artificial/estatística & dados numéricos , Telemedicina/estatística & dados numéricos , Adolescente , Criança , Pré-Escolar , Análise de Falha de Equipamento/métodos , Feminino , Humanos , Lactente , Masculino , New York/epidemiologia , Prevalência , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
6.
J Ultrasound Med ; 32(4): 675-82, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23525394

RESUMO

OBJECTIVES: Biventricular pacing may ameliorate symptoms of acute heart failure. Speckle-tracking echocardiography can assess cardiac function to elucidate mechanisms of benefit. Accordingly, radial and circumferential strain and radial and circumferential strain synchrony were measured with speckle-tracking echocardiography during biventricular pacing in a model of left ventricular (LV) volume overload. METHODS: Heart block was established in 4 open-chest anesthetized pigs. Left ventricular volume overload was induced with an ascending aorta-LV apex conduit. Measurements included cardiac output by an aortic flow probe, the maximum derivative of LV pressure versus time (dP/dtmax), and transseptal pressure synchrony. Biventricular pacing was performed for combinations of 3 interventricular delays and 3 LV pacing sites. Speckle-tracking echocardiographic analysis was applied to short-axis images at the midpapillary LV for 9 pacing combinations. Strain and synchrony parameters were correlated with hemodynamics. RESULTS: Increased cardiac output correlated with improved global circumferential strain (P = .002) but not changes in global radial strain or radial strain synchrony. Increased LV dP/dtmax was associated with improved circumferential strain in the septum (P < .001) and radial strain in the lateral wall (P = .046). Improved transseptal pressure synchrony was associated with improved global circumferential strain, but primarily in the septum (P < .001). Aortic valve closure occurred before peak radial strain in 62% of beats and before peak circumferential strain in 6%. CONCLUSIONS: During acute LV volume overload, hemodynamic improvement with biventricular pacing was associated with improved circumferential strain primarily in the septum. Radial strain and radial strain synchrony did not correlate with improvement, possibly due to delayed systolic contraction. An increase in circumferential strain in the septum associated with optimum transseptal pressure synchrony suggested improvement by interventricular assist from the right ventricle.


Assuntos
Terapia de Ressincronização Cardíaca , Modelos Animais de Doenças , Ecocardiografia/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia , Animais , Débito Cardíaco , Septos Cardíacos/fisiopatologia , Masculino , Suínos , Pressão Ventricular
7.
J Surg Res ; 178(2): 571-7, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22748597

RESUMO

BACKGROUND: We used speckle-tracking echocardiography to test the hypothesis that regional left ventricular (LV) strain would improve during optimized biventricular pacing (BiVP) in acute right ventricular (RV) pressure overload (PO). MATERIALS AND METHODS: Complete heart block and RVPO were induced in five open-chest fully anesthetized pigs. BiVP was optimized by adjusting atrioventricular and interventricular delays to maximize cardiac output derived from an aortic flow probe. LV short axis views were obtained during atrio-RV pacing (RVP), atrio-LV pacing (LVP), and BiVP. Intraventricular synchrony was assessed by comparing speckle-tracking echocardiography-derived time to peak (TTP) strain in the anterior septal (AS) and posterior wall segments. Segmental function was assessed using radial strain. RESULTS: Cardiac output was higher with optimized (RV first) BiVP than with LVP (0.96 ± 0.26 L/min versus 0.89 ± 0.27 L/min; P = 0.05). AS TTP strain (502 ± 19 ms) during LVP was prolonged versus BiVP (392 ± 58 ms) and versus RVP (390 ± 53 ms) (P = 0.0018). AS TTP strain during LVP was prolonged versus posterior (502 ± 19 ms versus 396 ± 72 ms, P = 0.0011). No significant difference in TTP strain in these segments was seen with BiVP or RVP. Posterior strain (20% ± 5%) increased 66% versus AS strain (12% ± 6%) during BiVP (P = 0.0029). A similar increase occurred during RVP (posterior 20% ± 3% versus AS 12% ± 7%, P = 0.0002). Posterior strain did not increase during LVP. CONCLUSIONS: BiVP and RVP restore intraventricular LV synchrony and increase regional function versus LVP during RVPO. RV pre-excitation unloads the RV and reduces the duration of AS contraction, facilitating synchrony of all LV segments and increasing free wall LV contraction.


Assuntos
Terapia de Ressincronização Cardíaca , Disfunção Ventricular Direita/terapia , Função Ventricular Esquerda , Animais , Débito Cardíaco , Masculino , Contração Miocárdica , Suínos , Disfunção Ventricular Direita/fisiopatologia
8.
J Cardiothorac Vasc Anesth ; 26(2): 209-16, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22000982

RESUMO

OBJECTIVES: Atrioventricular conduction prolongation (AVCP) in cardiac pacing is measurable and results primarily from delayed atrial conduction. Noninvasive methods for measuring atrial conduction are lacking. Accordingly, AVCP was used to estimate atrial conduction and investigate its role on the paced atrioventricular delay (pAVD) during biventricular pacing (BiVP) optimization. DESIGN: Retrospective analysis of data collected as part of a randomized controlled study of temporary BiVP after cardiopulmonary bypass. SETTING: Single-center study at university-affiliated tertiary care hospital. PARTICIPANTS: Cardiac surgical patients at risk of left ventricular failure after cardiopulmonary bypass. INTERVENTIONS: Temporary BiVP was optimized immediately after cardiopulmonary bypass. Vasoactive medication and fluid infusion rates were held constant during optimization. MEASUREMENTS AND MAIN RESULTS: For each patient the AVCP and the pAVD producing the optimum (highest) cardiac output (OptCO) and mean arterial pressure (OptMAP) were determined. Patients were stratified into long- and short-AVCP groups. Overall AVCP (mean ± standard deviation) was 64 ± 28 ms. For the short-AVCP group (<64 ms, n = 3), AVCP, OptCO, and OptMAP were 40 ± 11, 120 ± 0, and 150 ± 30 ms, respectively, and for the long-AVCP group (>64 ms, n = 4), these same parameters were 89 ± 10, 218 ± 44, and 218 ± 29 ms. OptCO and OptMAP were significantly less in the short-AVCP group (p = 0.015 and p = 0.029, respectively). CONCLUSIONS: AVCP varies widely after cardiopulmonary bypass, affecting optimum pAVD. Failure to correct for this can result in the selection of inappropriately short and potentially deleterious pAVDs, especially when nominal pAVD is used, causing BiVP to appear ineffective.


Assuntos
Nó Atrioventricular/fisiologia , Terapia de Ressincronização Cardíaca/métodos , Ponte Cardiopulmonar/efeitos adversos , Sistema de Condução Cardíaco/fisiologia , Idoso , Idoso de 80 Anos ou mais , Terapia de Ressincronização Cardíaca/normas , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
9.
J Card Surg ; 27(6): 771-3, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23173865

RESUMO

Increased thresholds in permanent epicardial leads pose a special challenge in the postoperative period. We present a case of complete heart block after surgical correction of a congenital heart defect that required conversion of an axial bipolar lead to unipolar lead to avoid lead replacement. We review the options for repair and describe our approach to this patient.


Assuntos
Bloqueio Cardíaco/terapia , Marca-Passo Artificial , Complicações Pós-Operatórias/terapia , Cardiopatias Congênitas/cirurgia , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/cirurgia , Reoperação , Insuficiência da Valva Tricúspide/cirurgia
10.
J Surg Res ; 171(1): 170-4, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20605592

RESUMO

BACKGROUND: Pulmonary artery (PA)-left atrial (LA) shunt models in piglets have been described, but technical details critical to limit morbidity/mortality and promote study of chronic cyanosis are lacking. Accordingly, we describe our experience with an optimized technique. MATERIALS AND METHODS: In 25 6- to 8-wk-old Yorkshire piglets, a beveled, 8 mm, polytetrafluoroethylene tube graft was anastomosed to the PA and LA. Systemic pressure was maintained at >60 mmHg. Saturation targets were met by adjusting a Teflon band on the graft and distal PA. The target oxygen saturation (SO(2)) was 85% on a 50% fraction of inspired oxygen (FiO(2)). If the SO(2) was <75% on a 50% FiO(2), the graft was constricted to achieve a SO(2) ≥ 90% on a 100% FiO(2) and 75%-80% on a 21% FiO(2). Complications affecting mortality were neutralized with a stepwise strategy to minimize risk. RESULTS: Thrombosis, blood loss, and arrhythmia were determinants of survival. Protocol optimization over time increased survival while assuring chronic cyanosis. Survival approached 90%, with a SO(2) of 80% to 90%, 3 to 5 wk postoperatively. Complications included bleeding, excessive hypoxemia, uncontrolled shunt flow, arrhythmias, and thrombosis. CONCLUSIONS: Refinement of surgical technique, shunt adjustment via graft banding, and thrombotic and arrhythmia prophylaxis are the keys to success with this model.


Assuntos
Cianose/patologia , Modelos Animais de Doenças , Cardiopatias Congênitas/patologia , Sus scrofa , Anastomose Cirúrgica , Animais , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/patologia , Materiais Biocompatíveis , Doença Crônica , Cianose/mortalidade , Átrios do Coração/patologia , Cardiopatias Congênitas/mortalidade , Hipóxia/patologia , Politetrafluoretileno , Artéria Pulmonar/patologia , Trombose/patologia
11.
J Cardiothorac Vasc Anesth ; 25(2): 238-42, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20638864

RESUMO

OBJECTIVE: To assess the stability of cardiac output, mean arterial pressure, and systemic vascular resistance during biventricular pacing (BiVP) optimization. DESIGN: Substudy analysis of data collected as part of a randomized controlled study examining the effects of optimized temporary BiVP after cardiopulmonary bypass (CPB). SETTING: A single-center study at a university-affiliated tertiary care hospital. PARTICIPANTS: Cardiac surgery patients at risk of left ventricular failure after CPB. INTERVENTIONS: BiVP was optimized immediately after CPB. Atrioventricular delay (7 unique settings) was optimized first, followed by the left ventricular pacing site (3 unique settings) and then the interventricular delay (9 unique settings). Each setting was tested twice for 10 seconds each time. Vasoactive medication and fluid infusion rates were held constant. MEASUREMENTS AND MAIN RESULTS: Aortic flow velocity and radial artery pressure were digitized, recorded, and averaged over single respiratory cycles. Least squares and linear regression/Wilcoxon analyses were applied to the first 7 patients studied. Subsequently, curvilinear analysis was applied to 15 patients. Changes in mean arterial pressure and systemic vascular resistance were statistically insignificant or too small to be meaningful by least squares analysis. During interventricular synchrony optimization, cardiac output and mean arterial pressure decreased (mean changes -5.7% and -2.5%, respectively; with standard errors 2.3% and 1.5%, respectively), whereas SVR increased (mean change 3.1% with standard error 3.4%). Only the change in cardiac output was statistically significant (p = 0.043). Curvilinear fits to data for 15 patients demonstrated progressive hemodynamic stability over the total testing period. CONCLUSION: BiVP optimization may be done safely in patients after CPB. With continuous monitoring of mean arterial pressure and cardiac output, the procedure results in no harmful hemodynamic perturbation.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Ponte Cardiopulmonar/métodos , Hemodinâmica/fisiologia , Idoso , Débito Cardíaco/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/prevenção & controle
12.
Europace ; 12(9): 1270-4, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20525728

RESUMO

AIMS: We investigated the utility of real-time stroke volume (SV) monitoring via the arterial pulse power technique to optimize cardiac resynchronization therapy (CRT) parameters at implant and prospectively evaluated the clinical and echocardiographic results. METHODS AND RESULTS: Fifteen patients with ischaemic or non-ischaemic dilated cardiomyopathy, sinus rhythm, Class III congestive heart failure, and QRS >150 ms underwent baseline 2D echocardiogram (echo), 6 min walk distance, and quality of life (QOL) questionnaire within 1 week of implant. Following implant, 0.3 mmol lithium chloride was injected to calibrate SV via dilution curve. Atrioventricular (AV) delay (90, 120, 200 ms, baseline: atrial pacing only) and V-V delay (-80 to 80 ms in 20 ms increments) were varied every 60 s. The radial artery pulse power autocorrelation method (PulseCO algorithm, LiDCO, Ltd.) was used to monitor SV on a beat-to-beat basis (LiDCO, Ltd.). Optimal parameters were programmed and echo, 6 min walk, and QOL were repeated at 6-8 weeks post-implant. Nine patients had >5% increase in SV after optimization (Group A). Six patients had <5% improvement in SV (Group B). Compared with Group B, Group A had significant improvements in left ventricular ejection fraction (LVEF) (11.0 +/- 8.5 vs. 0.8 +/- 2.0%) and decrease in left ventricular end-diastolic dimension (LVEDD) (-0.6 +/- 0.4 vs. -0.2 +/- 0.2 cm) and 6 min walk (346 +/- 226 vs. 32 +/-271 ft, P < or = 0.05). Group A patients also tended to have greater improvement in the septal-to-posterior wall motion delay on M-mode echo (P = 0.07). CONCLUSION: Real-time SV measurements can be used to optimize CRT at the time of implant. Improvement in SV correlates with improvement in LVEF, LVEDD, and 6 min walk, and improvement in echocardiographic dyssynchrony.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Volume Sistólico , Dispositivos de Terapia de Ressincronização Cardíaca , Cardiomiopatia Dilatada/diagnóstico por imagem , Cardiomiopatia Dilatada/terapia , Desfibriladores Implantáveis , Teste de Esforço , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Estudos Prospectivos , Qualidade de Vida , Ultrassonografia
13.
Pacing Clin Electrophysiol ; 33(2): 186-91, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20002886

RESUMO

BACKGROUND: In adults, transvenous implantable cardioverter defibrillator (ICD) lead failure rates are significant, and their occurrence increases with time from implant. There are limited data in children. The goal of this study was to assess lead survival in young patients undergoing ICD implantation at a single center. METHODS: Records of patients under 21 years old with transvenous ICD leads implanted at our center from June 1997 to August 2007 were retrospectively reviewed. Age, weight, height, diagnosis, lead and generator model, venous access technique, generator position, pacing thresholds, lead impedance, and R wave size were recorded. "Lead failure" was defined as any lead problem requiring surgical intervention to restore proper function to the ICD system. RESULTS: Seventy-one transvenous leads were included (70 patients). Average age at implant was 14.8 years (range 5.7-19.5). All the devices were implanted by a single operator (HMS). Venous access was obtained via cephalic cutdown in 66/71. Mean follow-up time was 2.8 years (range 0.2-7.8 years, median 2.3 years). There were no infections requiring explantation. There were four lead failures. Three were lead fractures, occurring 12, 13, and 19 months after implant. The fourth lead failed when an arrhythmia was not appropriately detected, and a second dedicated rate-sensing lead was thus implanted. Univariate analysis did not identify any variable to be a significant predictor of lead failure. Kaplan-Meier survival analysis demonstrated 5-year lead survival at 89.6%. CONCLUSIONS: ICD lead survival in children, when performed by an experienced operator, is similar to that found in adults.


Assuntos
Desfibriladores Implantáveis , Falha de Equipamento , Adolescente , Arritmias Cardíacas/diagnóstico , Criança , Pré-Escolar , Eletrodos Implantados , Feminino , Humanos , Masculino , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
14.
World J Surg ; 34(4): 669-74, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19921328

RESUMO

BACKGROUND The history of measuring myocardial edema by two-dimensional echocardiography and the pathophysiology of myocardial edema are reviewed. METHODS The relevance of this subject to management of children undergoing corrective surgery for single ventricle physiology and tetralogy of Fallot is reviewed. RESULTS Evidence is presented that myocardial edema is an ongoing clinical problem with relevance to management and outcomes. Methods for measuring mass increases noninvasively in the range of 10-25% with increases in myocardial water content on the order of 2-4% are now well established. CONCLUSIONS These methods and advanced animal models replicating conditions of surgery for cyanotic congenital heart disease set the stage for clinical advances in this important area.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Cardiopatias Congênitas/cirurgia , Ventrículos do Coração/anormalidades , Ventrículos do Coração/cirurgia , Disfunção Ventricular Esquerda/cirurgia , Animais , Modelos Animais de Doenças , Ecocardiografia , Edema/diagnóstico por imagem , Edema/fisiopatologia , Técnica de Fontan , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Papio , Suínos , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/fisiopatologia , Tetralogia de Fallot/cirurgia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia
15.
Circulation ; 118(23): 2338-44, 2008 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-19015406

RESUMO

BACKGROUND: Tetralogy of Fallot (TOF) typically results in clinical cyanosis or volume overload of the left ventricle (LV), depending on the direction and magnitude of shunting across the ventricular septal defect (VSD). The present study examines the effects of surgical TOF repair on LV mechanics and compares these changes between patients with VSD shunts that are predominantly right-to-left (R-L; "blue TOF") and those with VSD shunts that are predominantly left-to-right (L-R; "pink TOF"). METHODS AND RESULTS: Eleven patients (6 R-L and 5 L-R) 4.3 to 18.4 months old (median 7.1 months old) were studied. LV end-diastolic area (EDA) was calculated from transesophageal echocardiograms obtained during initiation and weaning of cardiopulmonary bypass. LV end-diastolic pressure was measured by micromanometer. Compliance was assessed by end-diastolic pressure-area curves. Contractility was assessed from preload recruitable stroke work by the stroke work-versus-LV EDA relation. VSD shunt direction was determined by preoperative Doppler echocardiography. Changes in LV function at the conclusion of cardiopulmonary bypass included decreased stroke area (from 6.6 +/- 0.9 to 4.1 +/- 0.4 cm(2)/m(2), P=0.012) and ejection fraction (from 55 +/- 2% to 41 +/- 3%, P<0.001). LV EDA at a common pressure in 8 patients decreased (from 10.4 +/- 1.4 to 7.6 +/- 1.2 cm(2)/m(2), P=0.003), which suggests a decrease in ventricular compliance. Additionally, the end-diastolic pressure-area curves shifted to the left in all patients. Preload recruitable stroke work decreased (from 34.8 +/- 2.4 to 21.8 +/- 2.6 mm Hg, P=0.007), which demonstrates a decrease in ventricular contractility. When separated by preoperative shunt direction, LV EDA increased in R-L patients by 0.9+/-0.5 cm(2)/m(2) postoperatively but decreased in L-R patients by 4.3 +/- 0.8 cm(2)/m(2) (P<0.001). Area ejection fraction decreased in all patients independent of shunting or change in LV EDA. CONCLUSIONS: LV diastolic and systolic function are depressed after TOF repair. Mechanical effects of the VSD patch and myocardial depressant effects of ischemia and reperfusion during surgery probably contribute to the observed changes in LV mechanics. Different effects of surgical repair on LV preload in pink and blue TOF also contribute to the spectrum of clinical results observed after surgery.


Assuntos
Disfunção Ventricular Esquerda/fisiopatologia , Fenômenos Biomecânicos , Ponte Cardiopulmonar , Eletrocardiografia , Testes de Função Cardíaca , Comunicação Interventricular/fisiopatologia , Comunicação Interventricular/cirurgia , Humanos , Lactente , Complicações Intraoperatórias , Traumatismo por Reperfusão Miocárdica , Disfunção Ventricular Esquerda/cirurgia
16.
Am J Physiol Heart Circ Physiol ; 297(6): H2220-6, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19855057

RESUMO

The goal of this work was to investigate the hemodynamic effects of simultaneous left ventricular (LV) pacing site (LVPS) and interventricular pacing delay (VVD) variation with biventricular pacing (BiVP) during acute LV failure. Simultaneously varying LVPS and VVD with BiVP has been shown to improve hemodynamics during acute right ventricular (RV) failure. However, effects during acute LV failure have not been reported. In six open-chest pigs, acute LV volume overload was induced by regurgitant flow via an aortic-LV conduit. Epicardial BiVP was implemented with right atrial and ventricular leads and a custom LV pacing array. Fifty-four LVPS-VVD combinations were tested in random order. Cardiac output was evaluated by aortic flow probe, ventricular systolic function by maximum rate of ventricular pressure change, and mechanical interventricular synchrony by normalized RV-LV pressure diagram area. Simultaneous LVPS-VVD variation improved all measures of cardiac function. The observed effect was different for each functional index, with evidence of LVPS-VVD interaction. Compared with effects of LVPS-VVD variation in a model of acute RV failure, hemodynamic changes were markedly different. However, in both models, maximum rate of ventricular pressure change of the failing ventricle was improved with synchronous interventricular contraction, suggesting that, in acute ventricular failure, BiVP can recruit the unstressed ventricle to support systolic function of the failing one. Thus simultaneously varying LVPS and VVD with BiVP during acute ventricular failure can improve cardiac function by "interventricular assist", with hemodynamic effects dependent on the type of failure. This supports the potential utility of temporary BiVP for the treatment of acute ventricular failure commonly seen after cardiac surgery.


Assuntos
Estimulação Cardíaca Artificial/métodos , Insuficiência Cardíaca/terapia , Disfunção Ventricular Esquerda/terapia , Disfunção Ventricular Direita/terapia , Função Ventricular Esquerda , Função Ventricular Direita , Doença Aguda , Animais , Pressão Sanguínea , Débito Cardíaco , Modelos Animais de Doenças , Técnicas Eletrofisiológicas Cardíacas , Insuficiência Cardíaca/patologia , Insuficiência Cardíaca/fisiopatologia , Masculino , Contração Miocárdica , Suínos , Fatores de Tempo , Disfunção Ventricular Esquerda/patologia , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Direita/patologia , Disfunção Ventricular Direita/fisiopatologia , Pressão Ventricular
17.
PLoS One ; 13(8): e0202275, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30096188

RESUMO

Drug-resistant bacteria such as methicillin-resistant Staphylococcus aureus (MRSA) are a target for new antimicrobial technologies. Far-UVC technology is an emerging disinfection method that directly kills microorganisms using light. In contrast with conventional UV sterilization, far-UVC light has antimicrobial capabilities without apparent harm to mammalian cells. This study examines the application of 224 nm far-UVC light delivered from a laser using an optical diffuser towards the goal of protecting against bacterial invasion around skin penetrating devices. Delivery of far-UVC using a laser and optical fibers enables exposure to unique geometries that would otherwise be shielded when using a lamp. Testing of the bactericidal potential of diffusing the far-UVC laser output over a large area was tested and yielded qualitative area killing results. The killing of MRSA using this method was also examined using an in vitro survival assay. Results followed a classic log-linear disinfection model with a rate constant of k = 0.51 cm2/mJ, which corresponds to an inactivation cross section of D90 = 4.5 mJ/cm2. This study establishes far-UVC delivered from a laser through an optical diffuser as a viable solution for disinfection of susceptible regions such as around catheters, drivelines, or other skin penetrating medical devices.


Assuntos
Desinfecção/instrumentação , Desinfecção/métodos , Lasers , Staphylococcus aureus Resistente à Meticilina/efeitos da radiação , Fibras Ópticas , Raios Ultravioleta , Tecnologia de Fibra Óptica , Técnicas In Vitro
18.
Circulation ; 114(1 Suppl): I56-61, 2006 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-16820638

RESUMO

BACKGROUND: We validated the clinical relevance of ventricular stiffness by examining surgical morbidity in children with univentricular hearts undergoing Fontan operation. We hypothesized that ventricular stiffness affects Fontan morbidity, particularly duration of pleural effusions. METHODS AND RESULTS: Sixteen children with right ventricular (RV) (n =11) or left ventricular (LV) (n =5) dominance were studied intraoperatively at a median age of 3.3 years (1.8 to 5.1). Transesophageal long-axis echocardiograms and ventricular pressure by micromanometer provided end-diastolic pressure (P) area (A) relations during initiation and conclusion of cardiopulmonary bypass. Curve fitting to the equation P=alphae(betaA) defined the ventricular stiffness constant, beta. Changes in beta and clinical correlations were examined. Ventricular stiffness increased after bypass in patients with complete pre-bypass and post-bypass data (n =11, P=0.023, mixed models methodology). Pre-bypass beta correlated well with duration of chest tube (CT) drainage (r=0.90, n =16), net perioperative fluid balance (r=0.71, n=14), and length of stay (LOS) (r=0.81, n =16). CT duration and LOS also correlated significantly with post-bypass beta (r=0.77 for both, n=11), but insignificantly with preoperative catheterization pressures. CONCLUSIONS: Intraoperative beta predicts duration of CT drainage, net perioperative fluid balance, and LOS after the Fontan operation. These observations could improve risk stratification and clinical management of children at high-risk undergoing the Fontan operation.


Assuntos
Técnica de Fontan , Ventrículos do Coração/patologia , Derrame Pleural/etiologia , Complicações Pós-Operatórias/etiologia , Tubos Torácicos , Pré-Escolar , Complacência (Medida de Distensibilidade) , Diástole , Procedimentos Cirúrgicos Eletivos , Feminino , Ventrículos do Coração/cirurgia , Humanos , Lactente , Tempo de Internação/estatística & dados numéricos , Masculino , Derrame Pleural/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Resultado do Tratamento , Equilíbrio Hidroeletrolítico
20.
Photochem Photobiol ; 93(6): 1509-1512, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28574149

RESUMO

Analysis of the emission pattern from optical diffuser tips is vital to their usage in biomedical applications, especially as they find growing functionality beyond established phototherapy techniques. The use of ultraviolet radiation with diffuser tips increases the need to accurately characterize these devices, both for effective application and to avoid potentially dangerous exposure conditions. This study presents a new method to capture the diffusion pattern at a high resolution through the use of radiochromic film. The film is positioned in a cylinder around the diffuser, light is emitted from the diffuser onto the film and the film expresses a color change relative to the exposure amount. The resulting emission map shows the distribution of power from the diffuser in all direction. This method, which is both quick and inexpensive, generates high-resolution data much simpler than previously published works which required precise goniometric positioning.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA