J Hosp Infect ; 69(2): 148-55, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18448198

RESUMO

This study evaluated the prevalence of anti-legionella antibodies in workers at hospitals with a long-term history of legionella contamination. The hospitals are located in Milan and Turin, northern Italy, and in Naples and Bari, southern Italy. Antibody prevalence and titres of healthcare workers, medical and dental students and blood donors were assessed. In total 28.5% of subjects were antibody positive, most frequently to L. pneumophila serogroups 7-14. Major differences were observed in seroprevalence and type of legionella antibody in persons from different geographic areas. Healthcare workers had a significantly higher frequency of antibodies compared with blood donors in Milan (35.4 vs 15.9%, P<0.001), whereas in Naples both groups exhibited high antibody frequency (48.8 vs 44.0%) and had a higher proportion of antibodies to legionella serogroups 1-6. Dental workers had a higher seroprevalence than office staff in Bari, but not in Turin, where daily disinfecting procedures had been adopted to avoid contamination of dental unit water. No association was found between the presence of antibodies and the presence of risk factors for legionellosis, nor with the occurrence of pneumonia and/or flu-like symptoms. In conclusion, the presence of legionella antibodies may be associated with occupational exposure in the hospital environment, but there was no evidence of any association with disease.


Assuntos
Anticorpos Antibacterianos/sangue , Pessoal de Saúde , Legionella/imunologia , Legionelose/epidemiologia , Legionelose/imunologia , Adulto , Feminino , Geografia , Hospitais , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Exposição Ocupacional , Prevalência
2.
Euro Surveill ; 4(11): 118-120, 1999 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12631884

RESUMO

The incidence of legionella infection in Europe overall in 1997 was 3.9 cases per million population, with the lowest rates reported by Malta and Norway and the highest by Denmark. Ninety cases were reported in Italy (1.5 cases/million), 20% of which were

3.
Ann Ig ; 12(4): 287-96, 2000.
Artigo em Italiano | MEDLINE | ID: mdl-11140095

RESUMO

An outbreak of nosocomial legionnaires' disease in a hospital of Northern Italy is described, together with the epidemiological survey and the control measures adopted. Two patients developed Legionella pneumophila (serogroup 1) pneumonia, one (immunodepressed) died. The Task Group organised by the Health Service excluded other previous nosocomial infections, and made controls on patients and personnel of at risk units (all negative). An intensive programme of environmental sampling and educational activities on personnel have been carried out. The environmental surveillance revealed that the centralised hot water distribution system of the hospital was colonised with Legionella. Shock heating and hyperchlorination of water were applied, which reduced the number of contaminated sites short term, but recolonisation took place two months later. We underline the difficulties encountered to control Legionella by active surveillance of water quality; once the system is contamined, Legionella eradication may be difficult and expensive, and cases of hospital-acquired legionnaieres' disease are likely to occur.


Assuntos
Infecção Hospitalar/prevenção & controle , Surtos de Doenças , Microbiologia Ambiental , Doença dos Legionários/prevenção & controle , Microbiologia da Água , Poluição da Água , Purificação da Água/métodos , Abastecimento de Água , Adulto , Cloro , Infecção Hospitalar/epidemiologia , Infecção Hospitalar/transmissão , Desinfecção/métodos , Contaminação de Equipamentos , Evolução Fatal , Feminino , Pessoal de Saúde/educação , Calefação , Departamentos Hospitalares , Humanos , Itália/epidemiologia , Doença dos Legionários/epidemiologia , Doença dos Legionários/transmissão , Serviço Hospitalar de Engenharia e Manutenção , Masculino , Pessoa de Meia-Idade , Risco
4.
Ann Ig ; 15(6): 817-24, 2003.
Artigo em Italiano | MEDLINE | ID: mdl-15049538

RESUMO

Despite legionellosis surveillance is active in Italy since many years, the disease notification appears still undervalued. A multicentric survey was carried out among 5 big Italian hospitals. It examined 11,435 discharge forms (1999-2001), reporting pneumonia diagnosis. Legionellosis (II class of notify system for infectious disease) was studied among pneumonia diagnosis by discharge forms. According to the ICD9-CM, there's no specific code for legionellosis (this disease is included among "others gram-negative pneumonia"). So the presumed pneumonia imputable to Legionella spp were the 2.7% of the whole number of analyzed discharge forms. Besides, the data regarding the other pneumonia showed that the etiological agent was specified only in the 11.2% of the case. This situation could be rectified both introducing adequate discharge forms codes and promoting the etiological diagnosis during the hospital stay.


Assuntos
Legionelose , Alta do Paciente , Registros , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Humanos , Pessoa de Meia-Idade
5.
Ann Ig ; 15(5): 493-503, 2003.
Artigo em Italiano | MEDLINE | ID: mdl-14969302

RESUMO

A multicentric Italian investigation on legionnaires' disease is in course to clarify host factors as well as pathogen associated characteristics involved in the infection/disease. The main goal of the research plan is to account for some critical aspects concerning identification and prevention of legionellosis. To improve knowledge on factors associated with Legionella spp colonisation in hot waters, to detect cases and to characterize risk factors in subjects which develop pneumonia are specific objectives of the research programme. Preliminary results show that hot waters of houses and hotels are frequently contaminated (22.6% and 54.6%, respectively), mainly by L. pneumophila. Microbial concentrations were low in domestic waters (<1.000 ufc/l), but higher in samples from the hotels (geom. mean 1.85 x 10(3) ufc/l). Warming system, age of the plant, type of building were risk factors significantly associated with Legionella spp positivity. The active surveillance on patients affected by pneumonia with search for Legionella urinary antigen allowed the identification of 34 cases, 3 of which of nosocomial origin, corresponding to 4.2% of the screened pneumonia. After informed consent, 26 subjects were recruited for a case-control-study to clarify risk factors for the disease.


Assuntos
Legionella/isolamento & purificação , Legionelose/epidemiologia , Pneumonia Bacteriana/epidemiologia , Microbiologia da Água , Humanos , Itália/epidemiologia , Pneumonia Bacteriana/microbiologia
6.
Scand J Thorac Cardiovasc Surg ; 22(1): 87-91, 1988.
Artigo em Inglês | MEDLINE | ID: mdl-3387957

RESUMO

A case of coarctation of the abdominal aorta associated with multiple stenotic renal arteries is reported. The patient was operated upon with successful thoraco-abdominal aortic bypass and direct reimplantation of 3 renal arteries on the graft. Surgical techniques for treatment of coarctation are discussed.


Assuntos
Coartação Aórtica/complicações , Obstrução da Artéria Renal/complicações , Adulto , Aorta Abdominal/anormalidades , Coartação Aórtica/cirurgia , Humanos , Masculino , Obstrução da Artéria Renal/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA