Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Europace ; 26(7)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38988256

RESUMO

AIMS: A pulsed electric field (PF) energy source is a novel potential option for catheter ablation of ventricular arrhythmias (VAs) as it can create deeper lesions, particularly in scarred tissue. However, very limited data exist on its efficacy and safety. This prospective observational study reports the initial experience with VA ablation using focal PF. METHODS AND RESULTS: The study population consisted of 44 patients (16 women, aged 61 ± 14years) with either frequent ventricular premature complexes (VPCs, 48%) or scar-related ventricular tachycardia (VT, 52%). Ablation was performed using an irrigated 4 mm tip catheter and a commercially available PF generator. On average, 16 ± 15 PF applications (25 A) were delivered per patient. Acute success was achieved in 84% of patients as assessed by elimination of VPC or reaching non-inducibility of VT. In three cases (7%), a transient conduction system block was observed during PF applications remotely from the septum. Root analysis revealed that this event was caused by current leakage from the proximal shaft electrodes in contact with the basal interventricular septum. Acute elimination of VPC was achieved in 81% patients and non-inducibility of VT in 83% patients. At the 3-month follow-up, persistent suppression of the VPC was confirmed on Holter monitoring in 81% patients. In the VT group, the mean follow-up was 116 ± 75 days and a total of 52% patients remained free of any VA. CONCLUSION: Pulsed electric field catheter ablation of a broad spectrum of VA is feasible with acute high efficacy; however, the short-term follow-up is less satisfactory for patients with scar-related VT.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/fisiopatologia , Ablação por Cateter/métodos , Ablação por Cateter/efeitos adversos , Resultado do Tratamento , Idoso , Complexos Ventriculares Prematuros/cirurgia , Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/diagnóstico , Estudos Prospectivos , Cicatriz/etiologia , Técnicas Eletrofisiológicas Cardíacas
2.
Clin Transplant ; 34(2): e13773, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31859379

RESUMO

INTRODUCTION: Heart rate slowing agents are frequently prescribed to manage heart transplant (HTx) patients with the assumption that higher heart rate is a risk factor in cardiovascular disease. PATIENTS AND METHODS: This prospective two-center study investigated early progression of cardiac allograft vasculopathy (CAV) in 116 HTx patients. Examinations by coronary optical coherence tomography and 24-hour ambulatory ECG monitoring were performed both at baseline (1 month after HTx) and during follow-up (12 months after HTx). RESULTS: During the first post-HTx year, we observed a significant reduction in the mean coronary luminal area from 9.0 ± 2.5 to 8.0 ± 2.4 mm2 (P < .001), and progression in mean intimal thickness (IT) from 106.5 ± 40.4 to 130.1 ± 53.0 µm (P < .001). No significant relationship was observed between baseline and follow-up mean heart rates and IT progression (R = .02, P = .83; R = -.13, P = .18). We found a mild inverse association between beta-blocker dosage at 12 months and IT progression (R = -.20, P = .035). CONCLUSION: Our study did not confirm a direct association between mean heart rate and progression of CAV. The role of beta blockers warrants further investigation, with our results indicating that they may play a protective role in early CAV development.


Assuntos
Doença da Artéria Coronariana , Transplante de Coração , Aloenxertos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/etiologia , Frequência Cardíaca , Transplante de Coração/efeitos adversos , Humanos , Estudos Prospectivos , Tomografia de Coerência Óptica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA