Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Clin Infect Dis ; 73(12): 2306-2313, 2021 12 16.
Artigo em Inglês | MEDLINE | ID: mdl-33421068

RESUMO

BACKGROUND: Vancomycin-resistant enterococci (VRE) are a major cause of morbidity and mortality in immunocompromised patients. Tracking the dissemination of VRE strains is crucial to understand the dynamics of emergence and spread of VRE in the hospital setting. METHODS: Whole genome sequencing (WGS) and phylogenetic analyses were performed to identify dominant VRE strains and potential transmission networks between 35 patients with VRE-positive rectal swabs and their rooms (main rooms and bathrooms) on the leukemia (LKM) and the hematopoietic cell transplant (HCT) floors. Sequence types (STs), drug resistance genes, and patients' outcomes were also determined. RESULTS: A total of 89 VRE strains grouped into 10 different STs, of which newly described STs were isolated from both floors (ST736, ST494, ST772, and ST1516). We observed highly genetically related strains transmitted between rooms, floors, and time periods in an average period of 39 days (ranging from 3 to 90 days). Of 5 VRE bacteremia events, 3 strains were lacking the pili operon fms14-17-13 (ST203) and the remaining 2 were resistant to daptomycin (DAP; ST736, ST664). Of 10 patients harboring DAP-resistant strains, only 2 were exposed to DAP within 4 months before strain recovery. CONCLUSIONS: Our comparisons of VRE strains derived from the environment and immunocompromised patients confirmed horizontal transfer of highly related genetic lineages of multidrug-resistant (particularly to DAP) VRE strains between HCT and LKM patients and their room environment. Implementing WGS can be useful in distinguishing VRE reservoirs where interventions can be targeted to prevent and control the spread of highly resistant organisms.


Assuntos
Daptomicina , Infecções por Bactérias Gram-Positivas , Transplante de Células-Tronco Hematopoéticas , Enterococos Resistentes à Vancomicina , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico , Daptomicina/farmacologia , Daptomicina/uso terapêutico , Infecções por Bactérias Gram-Positivas/tratamento farmacológico , Infecções por Bactérias Gram-Positivas/epidemiologia , Hospitais , Humanos , Testes de Sensibilidade Microbiana , Filogenia , Enterococos Resistentes à Vancomicina/genética
2.
BMC Infect Dis ; 21(1): 1084, 2021 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-34670520

RESUMO

BACKGROUND: The role of the environment in hospital acquired infections is well established. We examined the impact on the infection rate for hospital onset Clostridioides difficile (HO-CDI) of an environmental hygiene intervention in 48 hospitals over a 5 year period using a pulsed xenon ultraviolet (PX-UV) disinfection system. METHODS: Utilization data was collected directly from the automated PX-UV system and uploaded in real time to a database. HO-CDI data was provided by each facility. Data was analyzed at the unit level to determine compliance to disinfection protocols. Final data set included 5 years of data aggregated to the facility level, resulting in a dataset of 48 hospitals and a date range of January 2015-December 2019. Negative binomial regression was used with an offset on patient days to convert infection count data and assess HO-CDI rates vs. intervention compliance rate, total successful disinfection cycles, and total rooms disinfected. The K-Nearest Neighbor (KNN) machine learning algorithm was used to compare intervention compliance and total intervention cycles to presence of infection. RESULTS: All regression models depict a statistically significant inverse association between the intervention and HO-CDI rates. The KNN model predicts the presence of infection (or whether an infection will be present or not) with greater than 98% accuracy when considering both intervention compliance and total intervention cycles. CONCLUSIONS: The findings of this study indicate a strong inverse relationship between the utilization of the pulsed xenon intervention and HO-CDI rates.


Assuntos
Clostridioides , Desinfecção , Hospitais , Humanos , Raios Ultravioleta , Xenônio
3.
Comput Inform Nurs ; 39(12): 1035-1040, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34723870

RESUMO

As part of the development and testing of an innovative technology for tracking disinfection of portable medical equipment, end-user feedback was obtained during an initial trial on two acute care hospital units. The disinfection tracking device was installed on the computers-on-wheels and vital signs machines. Each device had the capability of detecting a cleaning event, reporting the event to an online database, and displaying the time since last cleaning event on a visual display. End-user feedback regarding functionality, usefulness of information provided, and impact on workflow was obtained by survey and facilitated group discussions. Seventeen frontline nurses completed the anonymous survey, and 22 participated in the facilitated group discussions. End users found the system functionally easy to use and the information about time since last cleaning useful and reported minimum disruption of workflow. Functionality of the system was confirmed by consistency between recorded and self-reported cleaning patterns. Managers found the data on cleaning of portable medical equipment helpful in validating compliance with hospital equipment cleaning policy. Frontline staff expressed appreciation for technology that helps them and improves outcomes but also discussed concerns about the potential for technology that creates extra work and disruption in the busy frontline nursing care delivery environment. Nurses were appreciative of opportunities to provide feedback and input into efforts to develop and introduce technology. Recorded cleaning events coincided with self-reported equipment cleaning patterns and illustrated that the device efficiently collects information deemed useful by the end user.


Assuntos
Desinfecção , Cuidados de Enfermagem , Retroalimentação , Humanos , Inquéritos e Questionários , Fluxo de Trabalho
4.
Clin Infect Dis ; 69(1): 167-178, 2019 06 18.
Artigo em Inglês | MEDLINE | ID: mdl-30395179

RESUMO

Bacteriophages (phages) may constitute a natural, safe, and effective strategy to prevent and control multidrug-resistant organisms (MDROs), and ESKAPE (Enterococcus faecium, Staphylococcus aureus, Klebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas aeruginosa, and Enterobacter species) pathogens in particular. Few clinical studies have assessed the safety and efficacy of phages in patients infected with MDROs. This systematic review summarizes and critically evaluates published studies of phages in clinical practice and presents the appropriate phage selection criteria, as well as recommendations for clinicians and scientists for a successful therapy. Articles were identified through a search of the PubMed, Ovid, EMBASE, and Cochrane Library databases. Among 1102 articles and abstracts, 30 studies were selected and evaluated using selective inclusion criteria, phage criteria, and study characteristics. Most studies showed efficacy (87%) and safety (67%) of the tested phages, but few studies examined phage resistance (35%). Clinical studies and regulatory changes are needed to determine the safety and efficacy of phages and to advance their use in patients with MDRO infections.


Assuntos
Antibacterianos/uso terapêutico , Infecções Bacterianas/terapia , Farmacorresistência Bacteriana Múltipla , Terapia por Fagos , Infecções por Acinetobacter/prevenção & controle , Infecções por Acinetobacter/terapia , Antibacterianos/farmacologia , Bactérias/efeitos dos fármacos , Ensaios Clínicos como Assunto , Infecções por Bactérias Gram-Positivas/prevenção & controle , Infecções por Bactérias Gram-Positivas/terapia , Humanos , Infecções por Klebsiella/prevenção & controle , Infecções por Klebsiella/terapia , Infecções por Pseudomonas/prevenção & controle , Infecções por Pseudomonas/terapia , Infecções Estafilocócicas/prevenção & controle , Infecções Estafilocócicas/terapia
5.
BMC Infect Dis ; 19(1): 575, 2019 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-31269912

RESUMO

BACKGROUND: Hospital environment in patient care has been linked on healthcare-associated infections (HAI). No touch disinfection technologies that utilize pulsed xenon ultraviolet light has been recognized to prevent infection in contaminated environments. The purpose of this study was: 1) to evaluate the effectiveness of pulsed-xenon ultraviolet light (PX-UV) disinfection for the reduction of bacteria on environmental surfaces of Hospital General Enrique Garcés, and 2) to evaluate the in-vitro efficacy against multi-drug resistance microorganisms. METHODS: This was a quality-improvement study looking at cleaning and disinfection of patient areas. During the study, a total of 146 surfaces from 17 rooms were sampled in a secondary 329-bed public medical center. Microbiological samples of high-touch surfaces were taken after terminal manual cleaning and after pulsed xenon ultraviolet disinfection. Cleaning staff were blinded to the study purpose and told clean following their usual protocols. For positive cultures PCR identification for carbapenemase-resistance genes (blaKPC, blaIMP, blaVIM, and blaNDM) were analyzed and confirmed by sequencing. The total number of colony forming units (CFU) were obtained and statistical analyses were conducted using Wilcoxon Rank Sum tests to evaluate the difference in CFU between terminal manual cleaning and after pulsed xenon ultraviolet disinfection. RESULTS: After manual disinfection of 124 surfaces showed a total of 3569 CFU which dropped to 889 CFU in 80 surfaces after pulsed xenon disinfection (p < 0.001). Overall, the surface and environmental contamination was reduced by 75% after PX-UV compared to manual cleaning and disinfection. There were statistically significant decreases in CFU counts of high touch surfaces in OR 87% (p < 0.001) and patient rooms 76% (p < 0.001). Four rooms presented serine carbapenemases blaKPC, and metallo beta-lactamases blaNDM, blaVIM, blaIMP. confirmed by PCR and sequencing. The in-vitro testing with endemic strains found that after five minutes of pulsed xenon ultraviolet exposure an 8-log reduction was achieved in all cases. CONCLUSION: This study is one of the first of its kind in an Ecuador Hospital. We found that pulsed-xenon ultraviolet disinfection technology is an efficacious complement to the established manual cleaning protocols and guidelines in the significant reduction of MDRO.


Assuntos
Desinfecção/métodos , Hospitais , Bactérias/genética , Proteínas de Bactérias/genética , Contagem de Colônia Microbiana , Infecção Hospitalar/prevenção & controle , Desinfecção/instrumentação , Farmacorresistência Bacteriana/genética , Equador , Humanos , Quartos de Pacientes , Raios Ultravioleta , Xenônio , beta-Lactamases/genética
6.
BMC Infect Dis ; 17(1): 800, 2017 12 28.
Artigo em Inglês | MEDLINE | ID: mdl-29281998

RESUMO

BACKGROUND: While research has demonstrated the importance of a clean health care environment, there is a lack of research on the role portable medical equipment (PME) play in the transmission cycle of healthcare-acquired infections (HAIs). This study investigated the patterns and sequence of contact events among health care workers, patients, surfaces, and medical equipment in a hospital environment. METHODS: Research staff observed patient care events over six different 24 h periods on six different hospital units. Each encounter was recorded as a sequence of events and analyzed using sequence analysis and visually represented by network plots. In addition, a point prevalence microbial sample was taken from the computer on wheels (COW). RESULTS: The most touched items during patient care was the individual patient (850), bedrail (375), bed-surface (302), and bed side Table (223). Three of the top ten most common subsequences included touching PME and the patient: computer on wheels ➔ patient (62 of 274 total sequences, 22.6%, contained this sequence), patient ➔ COW (20.4%), and patient ➔ IV pump (16.1%). The network plots revealed large interconnectedness among objects in the room, the patient, PME, and the healthcare worker. CONCLUSIONS: Our results demonstrated that PME such as COW and IV pump were two of the most highly-touched items during patient care. Even with proper hand sanitization and personal protective equipment, this sequence analysis reveals the potential for contamination from the patient and environment, to a vector such as portable medical equipment, and ultimately to another patient in the hospital.


Assuntos
Infecção Hospitalar/transmissão , Modelos Teóricos , Equipamentos e Provisões , Mãos , Pessoal de Saúde , Hospitais , Humanos , Unidades de Terapia Intensiva
7.
BMC Infect Dis ; 17(1): 672, 2017 10 10.
Artigo em Inglês | MEDLINE | ID: mdl-29017457

RESUMO

BACKGROUND: Environmental cleanliness is one of the contributing factors for surgical site infections in the operating rooms (ORs). To decrease environmental contamination, pulsed xenon ultraviolet (PX-UV), an easy and safe no-touch disinfection system, is employed in several hospital environments. The positive effect of this technology on environmental decontamination has been observed in patient rooms and ORs during the end-of-day cleaning but so far, no study explored its feasibility between surgical cases in the OR. METHODS: In this study, 5 high-touch surfaces in 30 ORs were sampled after manual cleaning and after PX-UV intervention mimicking between-case cleaning to avoid the disruption of the ORs' normal flow. The efficacy of a 1-min, 2-min, and 8-min cycle were tested by measuring the surfaces' contaminants by quantitative cultures using Tryptic Soy Agar contact plates. RESULTS: We showed that combining standard between-case manual cleaning of surfaces with a 2-min cycle of disinfection using a portable xenon pulsed ultraviolet light germicidal device eliminated at least 70% more bacterial load after manual cleaning. CONCLUSIONS: This study showed the proof of efficacy of a 2-min cycle of PX-UV in ORs in eliminating bacterial contaminants. This method will allow a short time for room turnover and a potential reduction of pathogen transmission to patients and possibly surgical site infections.


Assuntos
Desinfecção/métodos , Salas Cirúrgicas , Carga Bacteriana/efeitos da radiação , Desinfecção/instrumentação , Humanos , Salas Cirúrgicas/métodos , Raios Ultravioleta , Xenônio
8.
Adv Exp Med Biol ; 996: 255-266, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29124706

RESUMO

The role of the environment in surgical site infections is surprisingly understudied. UV disinfection holds promise for reducing the level of contamination in operating rooms and thereby lowering the risk of infection for patients. Issues such as the frequency, amount and locations for UV disinfection to have an impact on the risk of surgical site infection are recently emerging in the literature. As technologies and knowledge improve, UV disinfection will have a role to play in operating rooms in the future.


Assuntos
Infecção Hospitalar/prevenção & controle , Desinfecção/métodos , Ambiente Controlado , Contaminação de Equipamentos/prevenção & controle , Salas Cirúrgicas , Infecção da Ferida Cirúrgica/prevenção & controle , Raios Ultravioleta , Infecção Hospitalar/microbiologia , Humanos , Segurança do Paciente , Fatores de Proteção , Fatores de Risco , Infecção da Ferida Cirúrgica/microbiologia
9.
SAGE Open Med ; 11: 20503121231162290, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37026103

RESUMO

Objectives: Although routine disinfection of portable medical equipment is required in most hospitals, frontline staff may not be able to disinfect portable medical equipment at a rate that adequately maintains low bioburden on high-use equipment. This study quantified bioburden over an extended time period for two types of portable medical equipment, workstations on wheels and vitals machines, across three hospital wards. Methods: Bioburden was quantified via press plate samples taken from high touch surfaces on 10 workstations on wheels and 5 vitals machines on each of 3 medical surgical units. The samples were taken at three timepoints each day over a 4-week period, with random rotation of timepoints and portable medical equipment, such that frontline staff were not aware at which timepoint their portable medical equipment would be sampled. The mean bioburden from the different locations and portable medical equipment was estimated and compared with Bayesian multilevel negative binomial regression models. Results: Model estimated mean colony counts (95% credible interval) were 14.4 (7.7-26.7) for vitals machines and 29.2 (16.1-51.1) for workstations on wheels. For the workstations on wheel, colony counts were lower on the mouse, 0.22 (0.16-0.29), tray, 0.29 (0.22, 0.38), and keyboard, 0.43 (0.32-0.55), when compared to the arm, as assessed by incident rate ratios. Conclusions: Although routine disinfection is required, bioburden is still present across portable medical equipment on a variety of surfaces. The difference in bioburden levels among surfaces likely reflects differences in touch patterns for the different portable medical equipment and surfaces on the portable medical equipment. Although the association of portable medical equipment bioburden to healthcare-associated infection transmission was not assessed, this study provides evidence for the potential of portable medical equipment as a vector for healthcare-associated infection transmission despite hospital disinfection requirements.

10.
Pharmaceutics ; 14(8)2022 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-36015218

RESUMO

Phages are naturally occurring viruses that selectively kill bacterial species without disturbing the individual's normal flora, averting the collateral damage of antimicrobial usage. The safety and the effectiveness of phages have been mainly confirmed in the food industry as well as in animal models. In this study, we report on the successful isolation of phages specific to Vancomycin-resistant Enterococci, including Enterococcus faecium (VREfm) and Enterococcus faecalis from sewage samples, and demonstrate their efficacy and safety for VREfm infection in the greater wax moth Galleria mellonella model. No virulence-associated genes, antibiotic resistance genes or integrases were detected in the phages' genomes, rendering them safe to be used in an in vivo model. Phages may be considered as potential agents for therapy for bacterial infections secondary to multidrug-resistant organisms such as VREfm.

11.
Am J Infect Control ; 50(12): 1322-1326, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35081426

RESUMO

BACKGROUND: Portable medical equipment (PME) may contribute to transmission of multidrug-resistant organisms without proper disinfection. We studied whether a Disinfection Tracking System (DTS) with feedback prompt, attached to PME, can increase the frequency of PME disinfection. METHODS: DTS devices were placed on 10 workstations-on-wheels (WOWs) and 5 vitals machine (VM). After a 25 day "screen-off" period, the DTS device screens were turned on to display the number of hours since the last recorded disinfection event for a 42 day period. We used a Bayesian multilevel zero-inflated negative binomial model to compare the number of events in the display "screen-off" to the "screen-on" period. RESULTS: During the "screen-off" period, there were 1.26 and 0.49 mean disinfection events and during the "screen-on" period, there were 1.76 and 0.50 mean disinfection events for WOWs and VM, respectively, per day. The model estimated mean events per device per day in the the "screen-on" period for WOW's were 1.32 (1.10 - 1.57) times greater than those in the "screen-off" period and the "screen-on" period for VM devices was 1.37 (0.89 - 2.01) times greater than those in the "screen-off" period. CONCLUSIONS: The rate of disinfection events for WOWs increased following the implementation of the DTS feedback prompt.


Assuntos
Infecção Hospitalar , Desinfecção , Humanos , Retroalimentação , Teorema de Bayes , Infecção Hospitalar/prevenção & controle
12.
AIDS Behav ; 15(2): 454-68, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21110078

RESUMO

Contraceptive choice and discontinuation are poorly understood among HIV-positive women, and HIV disease and culture may influence decisions. We assessed factors influencing contraceptive decision-making among HIV-positive women in three countries. This qualitative assessment of 108 HIV-positive women (36/site, selected by age and parity strata) was conducted in Rio de Janeiro, Brazil; Kericho, Kenya; and Soweto, South Africa. Freelist interviews assessed knowledge and attitudes towards contraception and were analyzed enumerating frequency and saliency of mentions. There was intersite consensus around list items but priority and themes varied. Site-specific factors influencing contraceptive choice were male partner wishes and fertility desire (Brazil), side-effects (South Africa), and impact on health and HIV progression (Kenya). Age, parity, and taking antiretroviral therapy (ART) impacted some themes. Contraceptive use among HIV-positive women is substantially influenced by culture and other factors. Counseling efforts should consider individual factors in method selection and offer method variety to accommodate changing needs.


Assuntos
Comportamento Contraceptivo/psicologia , Anticoncepção/estatística & dados numéricos , Cultura , Fertilidade , Infecções por HIV/psicologia , Adolescente , Adulto , Brasil , Comportamento Contraceptivo/etnologia , Comparação Transcultural , Feminino , Infecções por HIV/tratamento farmacológico , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Entrevistas como Assunto , Quênia , Masculino , Menstruação/psicologia , Pessoa de Meia-Idade , Gravidez , Pesquisa Qualitativa , Parceiros Sexuais , África do Sul , Adulto Jovem
13.
Am J Infect Control ; 49(10): 1287-1291, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34565497

RESUMO

BACKGROUND: Portable Medical Equipment (PME) such as workstations-on-wheels (WOWs) and vital signs machines (VMs) have been linked to healthcare-associated infections. Routine visual monitoring of PME disinfection is difficult. An automated Disinfection Tracking System (DTS) was used to record and report the number of disinfection events of PME in a hospital setting. METHODS: The study was conducted in 2 acute-care units for 25-days to determine the pattern of recorded events from DTS on PME. Devices record disinfection events as moisture events and automatically store on a central database. DTS devices with "screen-on" feedback and "screen-off" devices with no display were placed on 10 WOWs and 5 VMs on separate units. RESULTS: A total of 421 moisture events were recorded for the "screen-on" and 345 for the "screen-off", during the 25-day implementation period on the 2 different hospital units. The highest number of events occurred between 6:00am-7:00am, with 69 & 75 moisture events recorded for Units 1 and 2, respectively. CONCLUSIONS: The pattern of disinfection events for WOWs and VMs demonstrated that most events occurred regularly at the times corresponding with nursing shift change. The DTS has the potential to continuously record, and report data related to PME disinfection.


Assuntos
Infecção Hospitalar , Desinfecção , Infecção Hospitalar/prevenção & controle , Contaminação de Equipamentos , Hospitais , Humanos
14.
Infect Control Hosp Epidemiol ; 42(2): 127-130, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32741425

RESUMO

OBJECTIVES: Prolonged survival of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) on environmental surfaces and personal protective equipment may lead to these surfaces transmitting this pathogen to others. We sought to determine the effectiveness of a pulsed-xenon ultraviolet (PX-UV) disinfection system in reducing the load of SARS-CoV-2 on hard surfaces and N95 respirators. METHODS: Chamber slides and N95 respirator material were directly inoculated with SARS-CoV-2 and were exposed to different durations of PX-UV. RESULTS: For hard surfaces, disinfection for 1, 2, and 5 minutes resulted in 3.53 log10, >4.54 log10, and >4.12 log10 reductions in viral load, respectively. For N95 respirators, disinfection for 5 minutes resulted in >4.79 log10 reduction in viral load. PX-UV significantly reduced SARS-CoV-2 on hard surfaces and N95 respirators. CONCLUSION: With the potential to rapidly disinfectant environmental surfaces and N95 respirators, PX-UV devices are a promising technology to reduce environmental and personal protective equipment bioburden and to enhance both healthcare worker and patient safety by reducing the risk of exposure to SARS-CoV-2.


Assuntos
COVID-19/prevenção & controle , Desinfecção/métodos , SARS-CoV-2/efeitos da radiação , Raios Ultravioleta , Animais , COVID-19/transmissão , COVID-19/virologia , Chlorocebus aethiops , Desinfecção/instrumentação , Reutilização de Equipamento/normas , Humanos , Respiradores N95 , Equipamento de Proteção Individual , SARS-CoV-2/fisiologia , Fatores de Tempo , Células Vero , Xenônio
15.
AIDS Care ; 22(1): 112-8, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20390488

RESUMO

The Russian federation has been undergoing a concentrated epidemic of HIV-1 with high rates of infection among injecting drug users. Less is known about the relative risk and contribution to the country's HIV epidemic by other at-risk populations including sex workers and men who have sex with men. The goals of this project were to explore demographic characteristics, substance use patterns, and estimate the prevalence of sexually transmitted infections (STIs) and high-risk behaviors among male sex workers (MSW) in Moscow and to assess the feasibility of prospective cohort recruitment and retention among this population. Research design was a longitudinal study of 50 men with a six-month follow-up period. Participants were recruited through venue-based and snowball sampling methods. Results revealed an HIV prevalence at baseline of 16%; one MSW seroconverted during the follow-up period, yielding an incidence estimate of 4.8/100PY (95%CI 0.0-11.2). Twenty-four percentage were diagnosed with at least one STI: 12% had syphilis; 8% had Human Papilloma Virus (HPV); and 4% had Herpes Simplex Virus (HSV)-2. Three (6%) of the study participants had evidence of previous Hepatitis C Virus (HCV) exposure at baseline. Retention rates were poor with higher retention significantly associated with older men (OR: 13.1, 95% CI 3.3-52.5). This was the first study to evaluate baseline demographics, substance use patterns, and prevalence of infectious disease among MSW in Moscow. Identification and recruitment of this population appears to be feasible, but retention a challenge. While the sample size in the current study was small, the results also suggested that this is a population at considerable high risk for HIV. MSW in Moscow may be an important at-risk population in the Russian HIV epidemic and further research is urgently required to address their needs and explore prevention strategies.


Assuntos
Trabalho Sexual/estatística & dados numéricos , Infecções Sexualmente Transmissíveis/epidemiologia , Transtornos Relacionados ao Uso de Substâncias/epidemiologia , Adolescente , Adulto , Fatores Etários , Preservativos/estatística & dados numéricos , Métodos Epidemiológicos , Infecções por HIV/epidemiologia , HIV-1 , Humanos , Masculino , Moscou/epidemiologia , Assunção de Riscos , Adulto Jovem
16.
Afr J Reprod Health ; 14(4 Spec no.): 98-109, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21812203

RESUMO

This study explored perceptions towards and utilization of contraception among HIV-positive, reproduction-age women in Kericho, Kenya, an area with high HIV and low contraceptive prevalence rates. Qualitative methods were used in three focus group discussions and 15 in-depth interviews to gather data from 46 HIV-positive women ages 18 to 45, purposively selected by age strata. Analysis was performed using ATLAS-ti (ATLAS-ti Center, Berlin). Most participants reported familiarity with modern contraceptives. Participants generally perceived that men opposed contraception. Some women indicated that their HIV status dictated contraceptive decisions, particularly with regard to abstinence. Women reported method discontinuation because of side effects, having met desired parity, and menstrual changes. Findings suggested that perceptions about side effects, opinions of the male partner, and HIV disease progression play important roles in contraceptive decisions. Counseling can dispel incorrect information and optimize contraceptive practice in this setting.


Assuntos
Comportamento de Escolha , Anticoncepção/estatística & dados numéricos , Soropositividade para HIV/psicologia , Adolescente , Adulto , Feminino , Grupos Focais , Soropositividade para HIV/epidemiologia , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Entrevistas como Assunto , Quênia/epidemiologia , Pessoa de Meia-Idade , Aceitação pelo Paciente de Cuidados de Saúde , Prevalência , Inquéritos e Questionários
17.
Am J Infect Control ; 48(1): 103-105, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31493936

RESUMO

Portable medical equipment (PME) can be an important reservoir of pathogens causing health care-associated infections. To address this, a novel, portable ultraviolet disinfection pod (UVDP) that allows for full 360-degree disinfection was developed. This investigation examined efficacy of the UVDP against microorganisms on clean, patient-ready PME. We found that the UVDP significantly reduced the number of recoverable bacteria on PME.


Assuntos
Anti-Infecciosos/administração & dosagem , Infecção Hospitalar/prevenção & controle , Desinfecção/instrumentação , Equipamentos e Provisões Hospitalares/microbiologia , Sistemas Automatizados de Assistência Junto ao Leito , Carga Bacteriana , Infecção Hospitalar/microbiologia , Desenho de Equipamento , Humanos , Raios Ultravioleta
18.
AIDS Behav ; 13 Suppl 1: 47-54, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19308719

RESUMO

The HIV epidemic in sub-Saharan Africa disproportionately affects women of reproductive age. The increasing provision of Highly Active Anti-Retroviral Therapy (HAART) with improved prognosis and maternal-fetal outcomes calls for an understanding of fertility planning for HIV-positive women. We describe the effect of HIV and HAART on pregnancy desires and contraceptive use among HIV-positive women in Soweto, South Africa. Focus group discussions and in-depth interviews were conducted with 42 HIV-positive women of reproductive age. Analysis was performed using ATLAS-ti (ATLAS-ti Center, Berlin). Emergent themes were impact of HIV diagnosis on pregnancy intentions; factors affecting contraceptive uptake including real and normative side effects, body image, and perceived vaginal wetness; and the mitigating influence of partnership on both pregnancy intentions and contraceptive use. Routine counseling about pregnancy desires and contraception should be offered to HIV-positive women.


Assuntos
Comportamento Contraceptivo , Tomada de Decisões , Fertilidade , Infecções por HIV/psicologia , Intenção , Adulto , Terapia Antirretroviral de Alta Atividade , Feminino , Grupos Focais , Infecções por HIV/tratamento farmacológico , Humanos , Entrevistas como Assunto , Gravidez , Pesquisa Qualitativa , África do Sul , Saúde da Mulher
19.
Am J Infect Control ; 46(9): 1003-1008, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29661632

RESUMO

BACKGROUND: Manual cleaning and disinfection of the operating room (OR) environment may be inadequate due to human error. No-touch technologies, such as pulsed-xenon ultraviolet light (PX-UV), can be used as an adjunct to manual cleaning processes to reduce surface contamination in the OR. This article reports the cumulative results from 23 hospitals across the United States that performed microbiologic validation of PX-UV disinfection after manual cleaning. METHODS: We obtained samples from 732 high-touch surfaces in 136 ORs at 23 hospitals, after manual terminal cleaning, and again after PX-UV disinfection (n = 1464 surface samples). Samples were enumerated after incubation, and the results are reported as total colony-forming units (CFU). RESULTS: The average CFU after manual cleaning ranged from 5.8 to 34.37, and after PX-UV, from 0.69 to 6.43. With manual cleaning alone, 67% of surfaces were still positive for CFUs; after PX-UV disinfection, that number decreased to 38% of all sampled surfaces-a 44% reduction. When comparing manual cleaning to PX-UV, the reduction in CFU count was statistically significant. CONCLUSION: When used after the manual cleaning process, the PX-UV device significantly reduced contamination on high-touch surfaces in the OR.


Assuntos
Descontaminação/métodos , Desinfecção/métodos , Microbiologia Ambiental , Salas Cirúrgicas , Raios Ultravioleta , Xenônio , Contagem de Colônia Microbiana , Hospitais , Humanos , Estados Unidos
20.
Drug Alcohol Depend ; 82 Suppl 1: S7-14, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16769449

RESUMO

OBJECTIVE: To examine differences by ethnicity of HIV prevalence and correlates among injection drug users (IDUs) in Dushanbe, Tajikistan. METHODS: The researchers enrolled 489 active adult IDUs in a cross-sectional risk factor study of HIV infection. Participants were provided HIV pre-and posttest counseling and risk reduction counseling and answered an interviewer-administered questionnaire. HIV-1 status was determined with rapid tests and confirmed with ELISA. RESULTS: Participants included four ethnicities: 204 Tajiks (49.1%), 145 Russians (29.7%), 58 Uzbeks (11.9%), and 46 participants of other nationalities (9.4%). Overall prevalence of HIV-1 infection was 12% and varied significantly by ethnicity: it was highest among ethnic Tajiks, at 19.2%; lowest among Russians and Uzbeks, at 3.4%; and 13% among other nationalities. Ethnic groups differed significantly in years injecting, receiving a needle from a needle exchange program (NEP), injecting in groups, having undergone drug treatment, reported condom use, and arrest history. Among Tajiks, HIV infection was significantly associated with daily injecting (OR 2.16); reporting that narcotics were very easy to obtain (OR 2.46); having undergone drug treatment (OR 2.75), and injecting "alone" (OR 3.12). CONCLUSIONS: Ethnic differences were strongly associated with HIV prevalence and risk behaviors in this multiethnic study, and prevention efforts might need to be targeted by ethnicity.


Assuntos
Etnicidade/estatística & dados numéricos , Infecções por HIV/etnologia , Assunção de Riscos , Abuso de Substâncias por Via Intravenosa/etnologia , Adulto , Área Programática de Saúde , Aconselhamento , Estudos Transversais , Demografia , Feminino , Infecções por HIV/epidemiologia , Humanos , Masculino , Prevalência , Características de Residência , Fatores de Risco , Abuso de Substâncias por Via Intravenosa/epidemiologia , Tadjiquistão/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA