Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Anal Bioanal Chem ; 405(29): 9571-7, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24081566

RESUMO

Coccidiostats are authorized in the European Union (EU) to be used as poultry feed additives. Maximum (residue) levels (M(R)Ls) have been set within the EU for consumer and animal protection against unintended carry-over, and monitoring is compulsory. This paper describes the single-laboratory validation of a previously developed multiplex flow cytometric immunoassay (FCIA) as screening method for coccidiostats in eggs and feed and provides and compares different approaches for the calculation of the cut-off levels which are not described in detail within Commission Decision 2002/657/EC. Comparable results were obtained between the statistical (reference) approach and the rapid approaches. With the most rapid approach, the cut-off levels for narasin/salinomycin, lasalocid, diclazuril, nicarbazin (DNC) and monensin in egg, calculated as percentages of inhibition (%B/B0), were 60, 32, 76, 80 and 84, respectively. In feed, the cut-off levels for narasin/salinomycin, lasalocid, nicarbazin (DNC) and monensin were 70, 64, 72 and 78, respectively, and could not be determined for diclazuril. For all analytes, except for diclazuril in feed, the rate of false positives (false non-compliant) in blank samples was lower than 1 %, and the rate of false negatives (false compliant) at the M(R)Ls was below 5 %. Additionally, very good correlations (r ranging from 0.994 to 0.9994) were observed between two different analysers, a sophisticated flow cytometer (FlexMAP 3D(®)) and a more cost-efficient and transportable planar imaging detector (MAGPIX(®)), hence demonstrating adequate transferability.


Assuntos
Ração Animal/análise , Coccidiostáticos/análise , Resíduos de Drogas/análise , Ovos/análise , Citometria de Fluxo/métodos , Imunoensaio/métodos , Animais , Galinhas
2.
Anal Bioanal Chem ; 397(5): 1955-63, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20431869

RESUMO

Chloramphenicol (CAP), a broad-spectrum antibiotic, was detected in several herb and grass samples from different geographic origins. Due to its suspected carcinogenicity and linkages with the development of aplastic anemia in humans, CAP is banned for use in food-producing animals in the European Union (EU) and many other countries. However, products of animal origin originating from Asian countries entering the European market are still found noncompliant (containing CAP) on a regular basis, even when there is no history of chloramphenicol use in these countries. A possible explanation for the continued detection of these residues is the natural occurrence of CAP in plant material which is used as animal feed, with the consequent transfer of the substance to the animal tissues. Approximately 110 samples were analyzed using liquid chromatography coupled with mass spectrometric detection. In 26 samples, the presence of CAP was confirmed using the criteria for banned substances defined by the EU. Among other plant materials, samples of the Artemisia family retrieved from Mongolia and from Utah, USA, and a therapeutic herb mixture obtained from local stores in the Netherlands proved to contain CAP at levels ranging from 0.1 to 450 microg/kg. These findings may have a major impact in relation to international trade and safety to the consumer. The results of this study demonstrate that noncompliant findings in animal-derived food products may in part be due to the natural occurrence of chloramphenicol in plant material. This has implications for the application of current EU, USA, and other legislation and the interpretation of analytical results with respect to the consideration of CAP as a xenobiotic veterinary drug residue and the regulatory actions taken upon its detection in food.


Assuntos
Antibacterianos/análise , Cloranfenicol/análise , Plantas Medicinais/química , Poaceae/química , Antibacterianos/metabolismo , Cloranfenicol/metabolismo , Cromatografia Líquida , Espectrometria de Massas , Plantas Medicinais/metabolismo , Poaceae/metabolismo
3.
Food Addit Contam Part B Surveill ; 13(2): 107-114, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32151232

RESUMO

Clenbuterol is a steroid-type drug used in respiratory treatments in both humans and animals. However, it has a secondary effect related to the hypertrophy process in muscle and fat reduction. The illegal or bad use of clenbuterol has been reported in several countries, but there is scarce information in South America, where the production and consumption of meat are considerable. In this sense, the present study aimed at evaluating the occurrence of clenbuterol in bovine muscle and liver samples from a high cattle production area of Ecuador in 2015 and 2018. For this purpose, 57-58 samples were evaluated in 2015 and 20 samples in 2018 using the Enzyme-Linked Inmuno Sorbent Assay and ultrahigh-performance liquid chromatography-tandem mass spectrometry. The results showed complained results for clenbuterol in meat samples from both years and 23% (2015) and 85% (2018) of the samples of meat complied the maximum residue level defined by CODEX.


Assuntos
Clembuterol/análise , Resíduos de Drogas/análise , Contaminação de Alimentos/análise , Fígado/química , Músculo Esquelético/química , Carne Vermelha/análise , Animais , Bovinos , Equador
4.
Foods ; 8(3)2019 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-30897757

RESUMO

Honey is one of the oldest sweetening foods and has economic importance, making this product attractive to adulteration with cheap sugars. This can cause a critical problem in the honey industry and a possible health risk. The present work has the aim of evaluating the authenticity of honey commercialized in two different provinces of Ecuador (Pichincha and Loja) by performing physicochemical and spectroscopic analyses. For this study 25 samples were collected from different places and markets and characterized by water, sucrose, reducing sugars and electric conductivity measurement. Also, their Raman and Infrared (IR) spectra were recorded and analysed using a Principal Component Analysis (PCA) in order to verify the quality of the honeys. In addition, a screening of several pesticides was performed in order to verify possible chemical threats to human health and honey bees. It was found that 8 samples have a deviation from the Standard established parameters. Two of them have a high difference in the content of sucrose and reducing sugars, which are located deviated from all the other samples in the PCA of the applied vibrational spectroscopy (IR/Raman), shaping two clear clusters. The results show that Raman and IR spectroscopy is appropriate techniques for the quality control of honey and correlates well with the physicochemical analyses.

5.
Talanta ; 132: 258-68, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25476307

RESUMO

The analysis of antibiotics in animal faeces is important to obtain more insight in the possible formation of bacterial resistance in the animals׳ gut, to learn about the dissemination of antibiotics to the environment, to monitor trends in antibiotic usage and to detect the illegal and off-label use of antibiotics. To facilitate these studies a comprehensive method for the analysis of trace levels of 44 antibiotic compounds including tetracyclines, quinolones, macrolides and sulfonamides in animal faeces by liquid chromatography in combination with tandem mass spectrometric (LC-MS/MS) detection is reported. The method is fully validated according to European regulation and showed satisfactory quantitative performance according to the stringent criteria adopted, with the exception of some of the macrolide compounds, which can be analysed with somewhat high measurement uncertainty. A large survey was carried out monitoring swine and cattle faeces and the outcomes were striking. In 55% of the swines, originating from 80% of the swine farms and in 75% of the calves, originating from 95% of the cattle farms, antibiotics were detected. Oxytetracycline, doxycycline and sulfadiazine were the most detected antibiotics, followed by tetracycline, flumequine, lincomycin and tylosin. Over 34% of the faeces samples contained two or more different antibiotics with a maximum of eight. Possible explanations for these findings are given and the effects are discussed.


Assuntos
Antibacterianos/isolamento & purificação , Fezes/química , Macrolídeos/isolamento & purificação , Quinolonas/isolamento & purificação , Sulfonamidas/isolamento & purificação , Tetraciclinas/isolamento & purificação , Criação de Animais Domésticos , Animais , Bovinos , Cromatografia Líquida , Europa (Continente) , Guias como Assunto , Suínos , Espectrometria de Massas em Tandem
6.
J Chromatogr A ; 1031(1-2): 1-9, 2004 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-15058562

RESUMO

We have investigated the potential of capillary-column-switching liquid chromatography coupled to tandem mass spectrometry (cLC-MS-MS) for the quantitative on-line trace analysis of target compounds in aqueous solutions. The technical design of the nano-scale cLC system developed at our Institute for peptide and protein identification has been tested and evaluated for the direct trace analysis of drugs in water samples. Sulphametoxazole, bezafibrate, metoprolol, carbamazepine and bisoprolol occurring frequently in Dutch waters, were selected as test compounds. Adequate conditions for trapping, elution and MS-MS detection were investigated by employing laboratory made 200 microm i.d. capillary columns packed with 5 microm aqua C18 material. In the final cLC-MS-MS conditions, a 1 cm length trapping column and a 4 cm length analytical column were selected. Under these conditions, the target compounds could be directly determined in water down to a level of around 50 ng/l employing only 25 microl of water sample. Validation was done by recovery experiments in ground-, surface- and drinking-water matrices as well as by the analysis of water samples with incurred residues and previously analyzed with a conventional procedure involving off-line solid-phase extraction and narrow-bore LC with MS-MS detection. The new methodology provided recoveries (50-500 ng/l level) between 50 and 114% with RSDs (n = 3, each level) below 20% for most of the compounds. Despite the somewhat less analytical performance in comparison to the conventional procedure, the on-line approach of the new methodology is very suitable for screening of drugs in aqueous samples.


Assuntos
Preparações Farmacêuticas/análise , Esgotos/análise , Poluentes Químicos da Água/análise , Cromatografia Líquida de Alta Pressão , Espectrometria de Massas , Sistemas On-Line , Solventes , Espectrofotometria Ultravioleta
7.
J Am Soc Mass Spectrom ; 24(1): 154-63, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23345060

RESUMO

We developed a procedure to determine the "identification power" of an LC-MS/MS method operated in the MRM acquisition mode, which is related to its selectivity. The probability of any compound showing the same precursor ion, product ions, and retention time as the compound of interest is used as a measure of selectivity. This is calculated based upon empirical models constructed from three very large compound databases. Based upon the final probability estimation, additional measures to assure unambiguous identification can be taken, like the selection of different or additional product ions. The reported procedure in combination with criteria for relative ion abundances results in a powerful technique to determine the (un)certainty of the selectivity of any LC-MS/MS analysis and thus the risk of false positive results. Furthermore, the procedure is very useful as a tool to validate method selectivity.


Assuntos
Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/normas , Bases de Dados Factuais , Íons/química , Peso Molecular , Preparações Farmacêuticas/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Incerteza
8.
J Agric Food Chem ; 61(17): 4004-10, 2013 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-23570678

RESUMO

Due to the unexpected findings of the banned antibiotic chloramphenicol in products of animal origin, feed, and straw, the hypothesis was studied that the drug is naturally present in soil, through production by soil bacteria, and subsequently can be transferred to crops. First, the stability of chloramphenicol in soil was studied. The fate of chloramphenicol highly depends on soil type and showed a half-life of approximately one day in nonsterile topsoil. It was found to be more stable in subsoil and sterile soils. Second, the production of chloramphenicol in soil was studied, and it was confirmed that Streptomyces venezuelae can produce chloramphenicol at appreciable amounts in nonsterile soil. Third, a transfer study was carried out using wheat and maize grown on three different soils that were weekly exposed to aqueous chloramphenicol solutions at different levels. Chloramphenicol was taken up by crops as determined by chiral liquid chromatography coupled to tandem mass spectrometric analysis, and the levels in crops were found to be bioavailability related. It was concluded that chloramphenicol residues can occur naturally in crops as a result of the production of chloramphenicol by soil bacteria in their natural environment and subsequent uptake by crops.


Assuntos
Cloranfenicol/química , Produtos Agrícolas/química , Microbiologia do Solo , Solo/química , Streptomyces/metabolismo , Cromatografia Líquida , Meia-Vida , Espectrometria de Massas em Tandem , Triticum/química , Zea mays/química
9.
Artigo em Inglês | MEDLINE | ID: mdl-22145799

RESUMO

The use of cephalosporin antibiotics in veterinary practice is likely to play an important role in the development of ß-lactam-resistant bacteria. To detect off-label cephalosporin antibiotic usage, an analytical method is needed that, besides the native compound, also detects their active metabolites. In this paper, the applicability of three approaches for the quantitative analysis of ceftiofur using LC-MS/MS is assessed, viz. (A) analysis of ceftiofur, desfuroylceftiofur and/or desfuroylceftiofur cystein disulfide, (B) derivatisation of ceftiofur metabolites to desfuroylceftiofur acetamide and (C) chemical hydrolysis using ammonia, to produce a marker compound for ceftiofur. We found that approach A was not suited for quantitative analysis of total ceftiofur concentration or for effectively detecting off-label use of ceftiofur. Approach B resulted in adequate quantitative results, but was considered a single compound method because it depends on cleavage of a thioester group, which is present in only a limited number of cephalosporin antibiotics. Approach C showed adequate quantitative results but, in contrast to approach B, it is applicable to a range of cephalosporin antibiotics. Therefore, it is applicable as a broad quantitative screening of cephalosporin compounds in poultry tissue samples to indicate off-label use of cephalosporins in poultry breeding. Based on this study, it was concluded that approach C is the most suitable to detect off-label use of a range of cephalosporin antibiotics.


Assuntos
Cefalosporinas/química , Galinhas , Cromatografia Líquida/métodos , Resíduos de Drogas/análise , Músculo Esquelético/química , Espectrometria de Massas em Tandem/métodos , Animais , Antibacterianos/química , Antibacterianos/metabolismo , Antibacterianos/farmacocinética , Cefalosporinas/metabolismo , Cefalosporinas/farmacocinética , Estrutura Molecular
10.
Anal Chim Acta ; 700(1-2): 114-25, 2011 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-21742124

RESUMO

The influence of natural organic matter on the screening of pharmaceuticals in water was determined by using high resolution liquid chromatography (HRLC) combined with full scan mass spectrometry (MS) techniques like time of flight (ToF) or Orbitrap MS. Water samples containing different amount of natural organic matter (NOM) and residues of a set of 11 pharmaceuticals were analyzed by using Exactive Orbitrap™ LC-MS. The samples were screened for residues of pharmaceuticals belonging to different classes like benzimidazoles, macrolides, penicillins, quinolones, sulfonamides, tetracyclines, tranquillizers, non-steroidal anti-inflammatory drugs (NSAIDs), anti-epileptics and lipid regulators. The method characteristics were established over a concentration range of 0.1-500 µg L(-1). The 11 pharmaceuticals were added to two effluent and two influent water samples. The NOM concentration within the samples ranged from 2 to 8 mg L(-1) of dissolved organic carbon. The HRLC-Exactive Orbitrap™ LC-MS system was set at a resolution of 50,000 (FWHM) and this selection was found sufficient for the detection of the list of pharmaceuticals. With this resolution setting, accurate mass measurements with errors below 2 ppm were found, despite of the NOM concentration of the different types of water samples. The linearities were acceptable with correlation coefficients greater than 0.95 for 30 of the 51 measured linearities. The limit of detection varies between 0.1 µg L(-1)and 100 µg L(-1). It was demonstrated that sensitivity could be affected by matrix constituents in both directions of signal reduction or enhancement. Finally it was concluded that with direct shoot method used (no sample pretreatment) all compounds, were detected but LODs depend on matrix-analyte-concentration combination. No direct relation was observed between NOM concentration and method characteristics. For accurate quantification the use of internal standards and/or sample clean-up is necessary. The direct shoot method is only applicable for qualitative screening purposes. The use of full scan MS makes it possible to search for unknown contaminants. With the use of adequate software and a database containing more than 50,000 entries a tool is available to search for unknowns.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas/métodos , Compostos Orgânicos/química , Preparações Farmacêuticas/análise , Poluentes Químicos da Água/análise , Bases de Dados Factuais , Espectrometria de Massas/instrumentação , Preparações Farmacêuticas/isolamento & purificação , Software , Poluentes Químicos da Água/isolamento & purificação
11.
Anal Chim Acta ; 685(2): 170-5, 2011 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-21168566

RESUMO

A proficiency test including the screening analysis of antibiotics in beef using cryogenicly minced materials was organized by RIKILT in 2009. The test included blank beef samples and beef samples spiked with either flumequine or a combination of lincomycin and spectinomycin around the maximum residue limits [1]. The suitability of the materials was demonstrated with a homogeneity and a stability study. This study showed that cryogenically minced spiked muscle material is suited for proficiency tests aiming at the screening and the confirmatory analysis. Of the 26 participants, 23 carried out their in-house screening approach involving microbial, biochemical or instrumental methods, or a combination of these to cover the broad range of antibiotic groups. The false negative rate was 73% for microbial methods, 50% for biochemical and 22% for instrumental methods. These results indicate that substantial effort is needed to improve screening approaches and that more regular proficiency tests are needed to reveal the shortcomings in the currently applied screening methods.


Assuntos
Antibacterianos/análise , Análise de Alimentos/métodos , Análise de Alimentos/normas , Contaminação de Alimentos/análise , Carne/análise , Controle de Qualidade
12.
J Chromatogr A ; 1218(41): 7331-40, 2011 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-21893319

RESUMO

Chloramphenicol is a broad-spectrum antibiotic with, apart from its human medicinal use, veterinary abuse in all major food-producing animals. Chloramphenicol occurs in four stereoisomers (all para-nitro substituted) and furthermore four meta-nitro analogs of chloramphenicol exist. In this paper these are referred to as eight chloramphenicol isomers. According to EU regulations an analytical method should be able to discriminate the analyte from interfering substances that might be present in the sample, including isomers. For the first time a quantitative method for the analysis of trace levels of eight chloramphenicol isomers in urine by chiral liquid chromatography in combination with tandem mass spectrometric detection is reported. The separation of the isomers on the analytical column, the clean-up of urine and the selectivity of the monitored product ions turned out to be critical parameters. To obtain reproducible retention isocratic elution on a chiral AGP column was applied. For urine samples matrix compounds present in the final extract caused decreased retention of the isomers on the chiral stationary phase and a lack of chromatographic resolution. Therefore an extended clean-up procedure that combines solid phase extraction and liquid-liquid extraction had to be developed. The final method was fully validated and showed satisfactory performance for all isomers with decision limits (CCα) ranging from 0.005 to 0.03 µg L(-1) and within-laboratory reproducibility of all isomers below 20% at the minimum required performance limit level of 0.3 µg L(-1).


Assuntos
Cloranfenicol/urina , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Cloranfenicol/química , Estabilidade de Medicamentos , Humanos , Análise dos Mínimos Quadrados , Extração Líquido-Líquido , Metanol/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Extração em Fase Sólida , Estereoisomerismo
13.
Anal Chim Acta ; 700(1-2): 78-85, 2011 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-21742120

RESUMO

This paper describes the discrimination of eight different isomers of chloramphenicol (CAP), an antibiotic banned for use in food producing animals, by reversed phase and chiral liquid chromatography in combination with tandem mass spectrometric detection. Previously, by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) the presence of CAP was confirmed in some grass and herb samples collected on Mongolian pastures up to concentrations of 450 µg kg(-1). It was not possible to establish the cause of CAP residues which has initiated research on the natural occurrence of this drug. CAP occurs in the para-configuration and in the meta-configuration and contains two chiral centers thus eight different isomeric configurations exist, namely four (RR, SS, RS, SR) meta-stereoisomers and four para-stereoisomers. It is known that only RR-p-CAP has antimicrobial properties. To find out if the CAP detected in the plant material samples is the active configuration, a high resolution reversed phase LC-MS/MS system was tested for its ability to separate the different isomers. This system proved to be able to discriminate between some isomers, but not between RR-p-CAP and SS-p-CAP, also called dextramycin. Despite a detailed elucidation of the product ions and the fragmentation patterns of all isomers, MS/MS did not add sufficient specificity for full discrimination of the isomers. Therefore a chiral liquid chromatographic separation with MS/MS detection that is able to distinguish all isomers was developed and finally the isomeric ratio of non-compliant plant material samples and some CAP formulations was determined using this system. This showed that Mongolian grass and herb samples only contain the biological active isomer of CAP as do the obtained formulations. Therefore the CAP present in the plant material might origin from the production by soil organisms or from a manufactured source.


Assuntos
Cloranfenicol/análise , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas em Tandem/métodos , Cromatografia de Fase Reversa/métodos , Poaceae/química , Estereoisomerismo
14.
J Chromatogr A ; 1216(46): 8177-86, 2009 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-19406407

RESUMO

This paper describes our research on the degradation of ceftiofur and cephapirin at physiological temperatures in kidney extract and in alkaline and acidic solution, conditions that regularly occur during sample preparation. Degradation products were identified using LC-ToF/MS, NMR and microbiological techniques. Additionally kinetics of the degradation processes were studied. A slight instability of cephapirin and desfuroylceftiofur was observed at elevated temperatures. Ceftiofur and cephapirin degraded immediately and completely in an alkaline environment, resulting in inactive degradation products. Ceftiofur and cephapirin also degraded immediately and completely in kidney extract resulting in both formerly reported metabolites as well as not previously reported products. Our research shows that conditions often occurring during the analysis of ceftiofur or cephapirin result in rapid degradation of both compounds. From this it is concluded that underestimation of the determined amounts of ceftiofur and cephapirin is likely to occur. Therefore, a new approach is needed for the analysis of both compounds newly identified degradation products.


Assuntos
Cefalosporinas/química , Cefapirina/química , Rim/química , Animais , Bovinos , Cefalosporinas/metabolismo , Cefapirina/metabolismo , Cromatografia Líquida , Rim/metabolismo , Cinética , Espectroscopia de Ressonância Magnética , Espectrometria de Massas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA