1.
Clin Infect Dis ; 75(7): 1131-1139, 2022 09 30.
Artigo em Inglês | MEDLINE | ID: mdl-35271694

RESUMO

BACKGROUND: Coronavirus disease 2019 (COVID-19) testing policies for symptomatic children attending US schools or daycare vary, and whether isolated symptoms should prompt testing is unclear. We evaluated children presenting for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) testing to determine if the likelihood of having a positive SARS-CoV-2 test differed between participants with 1 symptom vs ≥2 symptoms, and to examine the predictive capability of isolated symptoms. METHODS: Participants aged <18 years presenting for clinical SARS-CoV-2 molecular testing in 6 sites in urban/suburban/rural Georgia (July-October, 2021; Delta variant predominant) were queried about individual symptoms. Participants were classified into 3 groups: asymptomatic, 1 symptom only, or ≥2 symptoms. SARS-CoV-2 test results and clinical characteristics of the 3 groups were compared. Sensitivity, specificity, positive predictive values (PPVs), and negative predictive values (NPVs) for isolated symptoms were calculated by fitting a saturated Poisson model. RESULTS: Of 602 participants, 21.8% tested positive and 48.7% had a known or suspected close contact. Children reporting 1 symptom (n = 82; odds ratio [OR], 6.00 [95% confidence interval {CI}, 2.70-13.33]) and children reporting ≥2 symptoms (n = 365; OR, 5.25 [95% CI, 2.66-10.38]) were significantly more likely to have a positive COVID-19 test than asymptomatic children (n = 155), but they were not significantly different from each other (OR, 0.88 [95% CI, .52-1.49]). Sensitivity and PPV were highest for isolated fever (33% and 57%, respectively), cough (25% and 32%), and sore throat (21% and 45%); headache had low sensitivity (8%) but higher PPV (33%). Sensitivity and PPV of isolated congestion/rhinorrhea were 8% and 9%, respectively. CONCLUSIONS: With high Delta variant prevalence, children with isolated symptoms were as likely as those with multiple symptoms to test positive for COVID-19. Isolated fever, cough, sore throat, or headache, but not congestion/rhinorrhea, offered the highest predictive value.


Assuntos
COVID-19 , Faringite , COVID-19/diagnóstico , COVID-19/epidemiologia , Teste para COVID-19 , Criança , Tosse/epidemiologia , Febre/diagnóstico , Febre/epidemiologia , Cefaleia , Humanos , Rinorreia , SARS-CoV-2/genética
2.
JAMA ; 328(10): 935-940, 2022 09 13.
Artigo em Inglês | MEDLINE | ID: mdl-36018570

RESUMO

Importance: Despite the expansion of SARS-CoV-2 testing, available tests have not received Emergency Use Authorization for performance with self-collected anterior nares (nasal) swabs from children younger than 14 years because the effect of pediatric self-swabbing on SARS-CoV-2 test sensitivity is unknown. Objective: To characterize the ability of school-aged children to self-collect nasal swabs for SARS-CoV-2 testing compared with collection by health care workers. Design, Setting, and Participants: Cross-sectional study of 197 symptomatic children and adolescents aged 4 to 14 years old. Individuals were recruited based on results of testing in the Children's Healthcare of Atlanta system from July to August 2021. Exposures: Children and adolescents were given instructional material consisting of a short instructional video and a handout with written and visual steps for self-swab collection. Participants first provided a self-collected nasal swab. Health care workers then collected a second specimen. Main Outcomes and Measures: The primary outcome was SARS-CoV-2 detection and relative quantitation by cycle threshold (Ct) in self- vs health care worker-collected nasal swabs when tested with a real-time reverse transcriptase-polymerase chain reaction test with Emergency Use Authorization. Results: Among the study participants, 108 of 194 (55.7%) were male and the median age was 9 years (IQR, 6-11). Of the 196 participants, 87 (44.4%) tested positive for SARS-CoV-2 and 105 (53.6%) tested negative by both self- and health care worker-collected swabs. Two children tested positive by self- or health care worker-collected swab alone; 1 child had an invalid health care worker swab. Compared with health care worker-collected swabs, self-collected swabs had 97.8% (95% CI, 94.7%-100.0%) and 98.1% (95% CI, 95.6%-100.0%) positive and negative percent agreement, respectively, and SARS-CoV-2 Ct values did not differ significantly between groups (mean [SD] Ct, self-swab: 26.7 [5.4] vs health care worker swab: 26.3 [6.0]; P = .65). Conclusions and Relevance: After hearing and seeing simple instructional materials, children and adolescents aged 4 to 14 years self-collected nasal swabs that closely agreed on SARS-CoV-2 detection with swabs collected by health care workers.


Assuntos
COVID-19 , SARS-CoV-2 , Adolescente , COVID-19/diagnóstico , Teste para COVID-19 , Criança , Pré-Escolar , Estudos Transversais , Feminino , Pessoal de Saúde , Humanos , Masculino , Manejo de Espécimes/métodos
3.
Arch Pathol Lab Med ; 146(9): 1056-1061, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35576234

RESUMO

CONTEXT.­: Diagnostic testing for SARS-CoV-2 in symptomatic and asymptomatic children remains integral to care, particularly for supporting return to and attendance in schools. The concordance of SARS-CoV-2 detection in children, using various specimen types, has not been widely studied. OBJECTIVE.­: To compare 3 sample types for SARS-CoV-2 polymerase chain reaction (PCR) testing in children, collected and tested at a single facility. DESIGN.­: We prospectively recruited 142 symptomatic and asymptomatic children/young adults into a sample comparison study performed in a single health care system. Each child provided self-collected saliva, and a trained health care provider collected a mid-turbinate nasal swab and nasopharyngeal (NP) swab. Specimens were assayed within 24 hours of collection by using reverse transcription-polymerase chain reaction (RT-PCR) to detect SARS-CoV-2 on a single testing platform. RESULTS.­: Concurrently collected saliva and mid-turbinate swabs had greater than 95% positive agreement with NP swabs when obtained within 10 days of symptom onset. Positive agreement of saliva and mid-turbinate samples collected from children with symptom onset >10 days prior, or without symptoms, was 82% compared to NP swab samples. Cycle threshold (Ct) values for mid-turbinate nasal samples more closely correlated with Ct values from NP samples than from saliva samples. CONCLUSIONS.­: These findings suggest that all 3 sample types from children are useful for SARS-CoV-2 diagnostic testing by RT-PCR, and that concordance is greatest when the child has had symptoms of COVID-19 within the past 10 days. This study provides scientific justification for using sample types other than the NP swab for SARS-CoV-2 testing in pediatric populations.


Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Teste para COVID-19 , Criança , Humanos , Nasofaringe , Pacientes Ambulatoriais , Reação em Cadeia da Polimerase , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Transcrição Reversa , SARS-CoV-2/genética , Saliva , Manejo de Espécimes/métodos , Conchas Nasais , Adulto Jovem
4.
Cell Rep Methods ; 2(5): 100222, 2022 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-35527805

RESUMO

During the COVID-19 pandemic, the development of point-of-care (POC) diagnostic testing accelerated in an unparalleled fashion. As a result, there has been an increased need for accurate, robust, and easy-to-use POC testing in a variety of non-traditional settings (i.e., pharmacies, drive-thru sites, schools). While stakeholders often express the desire for POC technologies that are "as simple as digital pregnancy tests," there is little discussion of what this means in regards to device design, development, and assessment. The design of POC technologies and systems should take into account the capabilities and limitations of the users and their environments. Such "human factors" are important tenets that can help technology developers create POC technologies that are effective for end-users in a multitude of settings. Here, we review the core principles of human factors and discuss lessons learned during the evaluation process of SARS-CoV-2 POC testing.


Assuntos
COVID-19 , Feminino , Humanos , COVID-19/diagnóstico , Pandemias , SARS-CoV-2/genética , Testes Imediatos , Sistemas Automatizados de Assistência Junto ao Leito
5.
Chest ; 160(3): 919-928, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33932465

RESUMO

BACKGROUND: The use of electronic clinical decision support (CDS) systems for pediatric critical care trials is rare. We sought to describe in detail the use of a CDS tool (Children's Hospital Euglycemia for Kids Spreadsheet [CHECKS]), for the management of hyperglycemia during the 32 multicenter Heart And Lung Failure-Pediatric Insulin Titration trial. RESEARCH QUESTION: In critically ill pediatric patients who were treated with CHECKS, how was user compliance associated with outcomes; and what patient and clinician factors might account for the observed differences in CHECKS compliance? STUDY DESIGN AND METHODS: During an observational retrospective study of compliance with a CDS tool used during a prospective randomized controlled trial, we compared patients with high and low CHECKS compliance. We investigated the association between compliance and blood glucose metrics. We describe CHECKS and use a computer interface analysis framework (the user, function, representation, and task analysis framework) to categorize user interactions. We discuss implications for future randomized controlled trials. RESULTS: Over a 4.5-year period, 658 of 698 children were treated with the CHECKS protocol for ≥24 hours with a median of 119 recommendations per patient. Compliance per patient was high (median, 99.5%), with only 30 patients having low compliance (<90%). Patients with low compliance were from 16 of 32 sites, younger (P = .02), and less likely to be on inotropic support (P = .04). They were more likely to be have been assigned randomly to the lower blood glucose target (80% vs 48%; P < .001) and to have spent a shorter time (53% vs 75%; P < .001) at the blood glucose target. Overrides (classified by the user, function, representation, and task analysis framework), were largely (89%) due to the user with patient factors contributing 29% of the time. INTERPRETATION: The use of CHECKS for the Heart And Lung Failure-Pediatric Insulin Titration trial resulted in a highly reproducible and explicit method for the management of hyperglycemia in critically ill children across varied environments. CDS systems represent an important mechanism for conducting explicit complex pediatric critical care trials. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT01565941, registered March 29 2012; https://clinicaltrials.gov/ct2/show/NCT01565941?term=HALF-PINT&draw=2&rank=1.


Assuntos
Glicemia/análise , Cuidados Críticos , Sistemas de Apoio a Decisões Clínicas , Quimioterapia Assistida por Computador/métodos , Hiperglicemia , Insulina/administração & dosagem , Criança , Cuidados Críticos/métodos , Cuidados Críticos/organização & administração , Resultados de Cuidados Críticos , Esquema de Medicação , Cálculos da Dosagem de Medicamento , Feminino , Fidelidade a Diretrizes , Humanos , Hiperglicemia/sangue , Hiperglicemia/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Masculino , Estudos Retrospectivos
6.
IEEE Open J Eng Med Biol ; 2: 152-157, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34192287

RESUMO

The National Institutes of Health (NIH) launched the Rapid Acceleration of Diagnostics (RADxSM) Tech initiative to support the development and commercialization of novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) point-of-care test devices. The primary objective of the Clinical Studies Core (CSC) was to perform SARS-CoV-2 device studies involving diverse populations and settings. Within a few months, the infrastructure for clinical studies was developed, including a master protocol, digital study platform, data management system, single IRB, and multi-site partnerships. Data from some studies are being used to support Emergency Use Authorization of novel SARS-CoV-2 test devices. The CSC reduced the typical time and cost of developing medical devices and highlighted the impactful role of academic and NIH partnership in addressing public health needs at a rapid pace during a global pandemic. The structure, deployment, and lessons learned from this experience are widely applicable to future in vitro diagnostic device clinical studies.

7.
Sci Rep ; 11(1): 14604, 2021 07 16.
Artigo em Inglês | MEDLINE | ID: mdl-34272449

RESUMO

While there has been significant progress in the development of rapid COVID-19 diagnostics, as the pandemic unfolds, new challenges have emerged, including whether these technologies can reliably detect the more infectious variants of concern and be viably deployed in non-clinical settings as "self-tests". Multidisciplinary evaluation of the Abbott BinaxNOW COVID-19 Ag Card (BinaxNOW, a widely used rapid antigen test, included limit of detection, variant detection, test performance across different age-groups, and usability with self/caregiver-administration. While BinaxNOW detected the highly infectious variants, B.1.1.7 (Alpha) first identified in the UK, B.1.351 (Beta) first identified in South Africa, P.1 (Gamma) first identified in Brazil, B.1.617.2 (Delta) first identified in India and B.1.2, a non-VOC, test sensitivity decreased with decreasing viral loads. Moreover, BinaxNOW sensitivity trended lower when devices were performed by patients/caregivers themselves compared to trained clinical staff, despite universally high usability assessments following self/caregiver-administration among different age groups. Overall, these data indicate that while BinaxNOW accurately detects the new viral variants, as rapid COVID-19 tests enter the home, their already lower sensitivities compared to RT-PCR may decrease even more due to user error.


Assuntos
Teste Sorológico para COVID-19 , COVID-19/diagnóstico , Sistemas Automatizados de Assistência Junto ao Leito , Autoteste , Humanos , Limite de Detecção , SARS-CoV-2 , Sensibilidade e Especificidade
8.
ASAIO J ; 65(3): 277-284, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-29746311

RESUMO

This study evaluates whether three commonly used pediatric intensive care unit (PICU) severity of illness scores, pediatric risk of mortality score (PRISM) III, pediatric index of mortality (PIM) 2, and pediatric logistic organ dysfunction (PELOD), are the appropriate tools to discriminate mortality risk in children receiving extracorporeal membrane oxygenation (ECMO) support for respiratory failure. This study also evaluates the ability of the Pediatric Risk Estimate Score for Children Using Extracorporeal Respiratory Support (Ped-RESCUERS) to discriminate mortality risk in the same population, and whether Ped-RESCUERS' discrimination of mortality is improved by additional clinical and laboratory measures of renal, hepatic, neurologic, and hematologic dysfunction. A multi-institutional retrospective cohort study was conducted on children aged 29 days to 17 years with respiratory failure requiring respiratory ECMO support. Discrimination of mortality was evaluated with the area under the receiver operating curve (AUC); model calibration was measured by the Hosmer-Lemeshow goodness of fit test and Brier score. Admission PRISM-III, PIM-2, and PELOD were found to have poor ability to discriminate mortality with an AUC of 0.56 [0.46-0.66], 0.53 [0.43-0.62], and 0.57 [0.47-0.67], respectively. Alternatively, Ped-RESCUERS performed better with an AUC of 0.68 [0.59-0.77]. Higher alanine aminotransferase, ratio of the arterial partial pressure of oxygen the fraction of inspired oxygen, and lactic acidosis were independently associated with mortality and, when added to Ped-RESCUERS, resulted in an AUC of 0.75 [0.66-0.82]. Admission PRISM-III, PIM-2, and PELOD should not be used for pre-ECMO risk adjustment because they do not discriminate death. Extracorporeal membrane oxygenation population-derived scores should be used to risk adjust ECMO populations as opposed to general PICU population-derived scores.


Assuntos
Oxigenação por Membrana Extracorpórea/mortalidade , Insuficiência Respiratória/mortalidade , Insuficiência Respiratória/terapia , Índice de Gravidade de Doença , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Insuficiência Respiratória/fisiopatologia , Estudos Retrospectivos , Risco Ajustado
9.
Mark Health Serv ; 28(3): 43, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19062448
10.
Matern Child Health J ; 10(5 Suppl): S67-72, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16721664

RESUMO

OBJECTIVE: To assess health care providers (HCP) knowledge and practices regarding folic acid (FA) use for neural tube defect (NTD) prevention. METHODS: Two identical surveys were conducted among 611 obstetricians/gynecologists (OB/GYNs) and family/general physicians (FAM/GENs) (2002), and 500 physician assistants (PAs), nurse practitioners (NPs), certified nurse midwives (CNMs), and registered nurses (2003) to ascertain knowledge and practices regarding FA. For analysis, T-tests, univariate and multivariate logistic regression modeling were used. RESULTS: Universally, providers knew that FA prevents birth defects. Over 88% knew when a woman should start taking folic acid for the prevention of NTDs; and over 85% knew FA supplementation beyond what is available in the diet is necessary. However, only half knew that 50% of all pregnancies in the United States are unplanned. Women heard information about multivitamins or FA most often during well woman visits in obstetrical/gynecology (ob/gyn) practice settings (65%), and about 50% of the time during well woman visits in family/general (fam/gen) practice settings and 50% of the time at gynecology visits (both settings). Among all providers, 42% did not know the correct FA dosage (400 mug daily). HCPs taking multivitamins were more than twice as likely to recommend multivitamins to their patients (Odds Ratio [OR] 2.27 95%, Confidence Interval [CI] 1.75-2.94). HCPs with lower income clients (OR 1.49, CI 1.22-1.81) and HCPs with practices having more than 10% minorities (OR 1.46, CI 1.11-1.92) were more likely to recommend supplements. NPs in ob/gyn settings were most likely and FAM/GENs were least likely to recommend supplements (OR 3.06, CL 1.36-6.90 and OR 0.64, CL 0.45-0.90 respectively). CONCLUSIONS: Knowledge about birth defects and the necessity of supplemental FA was high. Increasing knowledge about unintended pregnancy rates and correct dosages of FA is needed. The strongest predictor for recommending the use of FA supplements was whether the provider took a multivitamin.


Assuntos
Atitude do Pessoal de Saúde , Competência Clínica , Medicina de Família e Comunidade/educação , Ácido Fólico/uso terapêutico , Defeitos do Tubo Neural/prevenção & controle , Obstetrícia/educação , Padrões de Prática Médica/estatística & dados numéricos , Cuidado Pré-Natal/normas , Medicina de Família e Comunidade/normas , Feminino , Ácido Fólico/administração & dosagem , Pesquisas sobre Atenção à Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Obstetrícia/normas , Gravidez , Inquéritos e Questionários , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA