Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 154
Filtrar
1.
J Cardiovasc Electrophysiol ; 35(10): 1997-2005, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39135364

RESUMO

INTRODUCTION: Thermal atrial fibrillation (AF) ablation exerts an additive treatment effect on the cardiac autonomic nervous system (CANS). This effect is mainly reported during ablation of the right superior pulmonary vein (RSPV), modulating the right anterior ganglionated plexus (RAGP), which contains parasympathetic innervation to the sinoatrial node in the epicardial fat pad between RSPV and superior vena cava (SVC). However, a variable response to neuromodulation after ablation is observed, with little to no effect in some patients. Our objective was to assess clinical and anatomic predictors of thermal ablation-induced CANS changes, as assessed via variations in heart rate (HR) postablation. METHODS: Consecutive paroxysmal AF patients undergoing first-time PV isolation by the cryoballoon (CB) or radiofrequency balloon (RFB) within a 12-month time frame and with preprocedural cardiac computed tomography (CT), were evaluated. Preablation and 24-h postablation electrocardiograms in sinus rhythm were collected and analyzed to assess HR. Anatomic evaluation by CT included the measurement of the shortest distance between the SVC and RSPV ostium (RSPV-SVC distance). RESULTS: A total of 97 patients (CB, n = 50 vs. RFB, n = 47) were included, with similar baseline characteristics between both groups. A significant HR increase postablation (ΔHR ≥ 15 bpm) occurred in a total of 37 patients (38.1%), without difference in number of patients between both thermal ablation technologies (CB, 19 [51%]), RFB, 18 [49%]). Independent predictors for increased HR were RSPV-SVC distance (odds ratio [OR]: 0.49, CI: 0.34-0.71, p value < .001), and age (OR: 0.94, CI: 0.89-0.98, p value = .003). CONCLUSIONS: Thermal balloon-based PV isolation influences the CANS through its effect on the RAGP, especially in younger patients and patients with shorter RSPV-SVC distance.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Frequência Cardíaca , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Criocirurgia/efeitos adversos , Ablação por Cateter/efeitos adversos , Fatores de Tempo , Potenciais de Ação , Veia Cava Superior/cirurgia , Veia Cava Superior/fisiopatologia , Sistema Nervoso Autônomo/fisiopatologia , Sistema Nervoso Autônomo/cirurgia , Estudos Retrospectivos , Fatores de Risco
2.
Europace ; 26(10)2024 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-39351961

RESUMO

AIMS: Rhythm control of non-paroxysmal atrial fibrillation (AF) is significantly more challenging, as a result of arrhythmia perpetuation promoting atrial substrate changes and AF maintenance. We describe a tailored ablation strategy targeting multiple left atrial (LA) sites via a pentaspline pulsed field ablation (PFA) catheter in persistent AF sustained beyond 6 months (PerAF > 6 m) and long-standing persistent AF (LSPAF). METHODS AND RESULTS: The ablation protocol included the following stages: pulmonary vein antral and posterior wall isolation plus anterior roof line ablation (Stage 1); electrogram-guided substrate ablation (Stage 2); atrial tachyarrhythmia regionalization and ablation (Stage 3). Seventy-two [age:68 ± 10years, 61.1%males; AF history: 25 (18-45) months] patients with PerAF > 6 m (52.8%) and LSPAF (47.2%) underwent their first PFA via the FarapulseTM system. LA substrate ablation (Stage 1 and 2) led to AF termination in 95.8% of patients. AF organized into a left-sided atrial flutter (AFlu) in 46 (74.2%) patients. The PFA catheter was used to identify LA sites showing diastolic, low-voltage electrograms and entrainment from its splines was performed to confirm the pacing site was inside the AFlu circuit. Left AFlu termination was achieved in all cases via PFA delivery. Total procedural and LA dwell times were 112 ± 25 min and 59 ± 22 min, respectively. Major complications occurred in 2 (2.8%) patients. Single-procedure success rate was 74.6% after 14.9 ± 2.7 months of follow-up; AF-free survival was 89.2%. CONCLUSION: In our cohort, PFA-based AF substrate ablation led to AF termination in 95.8% of cases. Very favourable clinical outcomes were observed during >1 year of follow-up.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Humanos , Masculino , Ablação por Cateter/métodos , Feminino , Idoso , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Resultado do Tratamento , Recidiva , Fatores de Tempo , Cateteres Cardíacos , Frequência Cardíaca , Potenciais de Ação
3.
J Cardiovasc Electrophysiol ; 34(11): 2393-2397, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37792572

RESUMO

INTRODUCTION: Pulmonary vein isolation (PVI) with thermal energy is characterized by concomitant ablation of the surrounding ganglionated plexi (GP). Pulsed-field ablation (PFA) selectively targets the myocardium and seems associated with only negligible effects on the autonomic nervous system (ANS). However, little is known about the dynamic effects of PFA on the GP immediately after PVI. This study sought to investigate the degree and acute vagal modulation induced by the FarapulseTM PFA system during PVI compared with single-shot thermal ablation. METHODS: A total of 76 patients underwent first-time PVI with either FarapulseTM PFA (PFA group, n = 40) or cryoballoon ablation (thermal ablation group, n = 36) for paroxysmal atrial fibrillation (AF). The effect on the ANS in the two groups was assessed before and after PVI with extracardiac vagal stimulation (ECVS). To capture any transient effects of PFA on the ANS, in a subgroup of PFA patients ECVS was repeated at three predefined timepoints: (1) before PVI (T0); (2) immediately after PVI (T1); and (3) 10 min after the last energy application (T2). RESULTS: Despite similar baseline values, the vagal response induced by ECVS after PVI almost disappeared in the thermal ablation group but persisted in the PFA group (thermal group: 840 [706-1090] ms, p < .001 compared to baseline; PFA group: 11 466 [8720-12 293] ms, p = .70 compared to baseline). Intraprocedural vagal reactions (defined as RR increase >50%, transitory asystole, or atrioventricular block) occurred more frequently with PFA than thermal ablation (70% vs. 28%, p = .001). Moreover, heart rate 24 h post-PVI increased more with thermal ablation than with PFA (16.5 ± 9.0 vs. 2.6 ± 6.1 beats/min, p < .001). In the subgroup of PFA patients undergoing repeated ANS modulation assessment (n = 11), ECVS demonstrated that PFA determined a significant acute suppression of the vagal response immediately after PVI (p < .001 compared to baseline), which recovered almost completely within 10 min. CONCLUSION: PVI with the FarapulseTM PFA system is associated with only transitory and short-lasting vagal effects on the ANS which recover almost completely within a few minutes after ablation. The impact of this phenomenon on AF outcome needs to be further investigated.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Sistema Nervoso Autônomo/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Nervo Vago/cirurgia , Frequência Cardíaca , Ablação por Cateter/efeitos adversos , Resultado do Tratamento
4.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37671682

RESUMO

AIMS: Cryoballoon (CB) ablation is the mainstay of single-shot pulmonary vein isolation (PVI). A radiofrequency balloon (RFB) catheter has recently emerged as an alternative. However, these two technologies have not been compared. This study aims to evaluate the freedom from atrial tachyarrhythmias (ATas) at 1 year: procedural characteristics, efficacy, and safety of the novel RFB compared with CB for PVI in patients with paroxysmal atrial fibrillation (AF). METHODS AND RESULTS: This prospective multi-centre study included consecutive patients with symptomatic drug-resistant paroxysmal AF who underwent PVI with RFB or CB between July 2021 and January 2022 from three European centres. A total of 375 consecutive patients were included, 125 in the RFB group and 250 in the CB. Both groups had comparable clinical characteristics. At 12.33 ± 4.91 months, ATas-free rates were 83.20% and 82.00% in the RFB and CB groups, respectively (P > 0.05). Compared with the CB group, the RFB group showed a shorter procedure time [59.91 (45.80-77.12) vs. 77.0 (35.13-122.71) min (P < 0.001)], dwell time [19.59 (14.41-30.24) vs. 27.03 (17.11-57.21) min (P = 0.04)], time to isolation, and thermal energy delivery in all pulmonary veins (P < 0.001). First-pass isolation was comparable. No major complications occurred in either group, with no stroke, atrio-oesophageal fistula, or permanent phrenic nerve injury. Transient phrenic nerve palsy occurred more frequently with CB than RFB (7.20% vs. 3.20%; P = 0.02). Oesophageal temperature rise occurred in 21 (16.8%) patients in the RFB group, and gastroscopy showed erythema in two of them with complete recovery after 30 days. CONCLUSIONS: The RFB appears to have a safety and efficacy profile similar to that of the CB for PVI. Shorter procedural times appear to be driven by shorter left atrial dwell and thermal delivery times.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Fístula Esofágica , Veias Pulmonares , Humanos , Estudos Prospectivos
5.
Europace ; 25(3): 896-904, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36738245

RESUMO

AIMS: The multielectrode radiofrequency balloon catheter (RFB) has been developed to achieve safe and effective pulmonary vein isolation (PVI) for atrial fibrillation (AF) ablation. This single-centre study aimed to evaluate the midterm clinical outcome and predictors of single-shot PVI with the novel RFB. METHODS AND RESULTS: All consecutive patients with symptomatic paroxysmal or persistent AF undergoing first-time PVI with the RFB were prospectively included. Clinical and procedural parameters were systematically collected. The primary safety endpoint was defined as any major periprocedural complications. The primary efficacy endpoint consisted of freedom from any atrial tachyarrhythmias (ATas) lasting >30 s during the follow-up after a 3-month blanking period. Persistent single-shot PVI was defined as PVI achieved with a single RFB application without acute reconnection. A total of 104 consecutive patients (mean age 64.3 ± 11.4 years, 56.7% males) were included. 15 patients (14.4%) presented with persistent AF. The procedure time was 59.0 min with a dwell time of 20.0 min. One major complication occurred in one patient. At a mean follow-up of 10.1 ± 5.3 months, freedom from ATas was 82.9%. ATas occurred in 14 patients, 11/69 patients (15.9%) with paroxysmal AF and 3/13 (23.1%) with persistent AF. The best cut-offs to predict persistent single-shot PVI were impedance drop >19.2 Ω [area under the receiver operator characteristic curve (AUC) 0.74] and temperature rise >11.1° C (AUC 0.77). CONCLUSION: In a large cohort of patients undergoing PVI with the RFB, the complication rate was 1%. At a mid-term follow-up of 10.1 ± 5.3 months, freedom from ATas was 82.9%. Specific cut-offs of impedance drop and temperature rise may be useful to predict persistent single-shot isolation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Resultado do Tratamento , Seguimentos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Taquicardia/cirurgia , Catéteres , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
6.
Europace ; 25(12)2023 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-38064697

RESUMO

AIMS: Catheter ablation (CA) is an established treatment for atrial fibrillation (AF). A computed tomography (CT) may be performed before ablation to evaluate the anatomy of pulmonary veins. The aim of this study is to investigate the prevalence of patients with coronary artery disease (CAD) detected by cardiac CT scan pre-ablation and to evaluate the impact of CAD and revascularization on outcomes after AF ablation. METHODS AND RESULTS: All consecutive patients with AF diagnosis, hospitalized at Universitair Ziekenhuis Brussel, Belgium, between 2015 and 2019, were prospectively screened for enrolment in the study. Inclusion criteria were (i) AF diagnosis, (ii) first procedure of AF ablation with cryoballoon CA, and (iii) contrast CT scan performed pre-ablation. A total of 576 consecutive patients were prospectively included and analysed in this study. At CT scan, 122 patients (21.2%) were diagnosed with CAD, of whom 41 patients (7.1%) with critical CAD. At survival analysis, critical CAD at CT scan was a predictor of atrial tachyarrhythmia (AT) recurrence during the follow-up, only in Cox univariate analysis [hazard ratio (HR) = 1.79] but was not an independent predictor in Cox multivariate analysis. At Cox multivariate analysis, independent predictors of AT recurrence were as follows: persistent AF (HR = 2.93) and left atrium volume index (HR = 1.04). CONCLUSION: In patients undergoing CT scan before AF ablation, critical CAD was diagnosed in 7.1% of patients. Coronary artery disease and revascularization were not independent predictors of recurrence; thus, in this patient population, AF ablation should not be denied and can be performed together with CAD treatment.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Doença da Artéria Coronariana , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/cirurgia , Resultado do Tratamento , Átrios do Coração , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva
7.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37246904

RESUMO

AIMS: Hybrid atrial fibrillation (AF) ablation is a promising approach in non-paroxysmal AF. The aim of this study is to assess the long-term outcomes of hybrid ablation in a large cohort of patients after both an initial and as a redo procedure. METHODS AND RESULTS: All consecutive patients undergoing hybrid AF ablation at UZ Brussel from 2010 to 2020 were retrospectively evaluated. Hybrid AF ablation was performed in a one-step procedure: (i) thoracoscopic ablation followed by (ii) endocardial mapping and eventual ablation. All patients received PVI and posterior wall isolation. Additional lesions were performed based on clinical indication and physician judgement. Primary endpoint was freedom from atrial tachyarrhythmias (ATas). A total of 120 consecutive patients were included, 85 patients (70.8%) underwent hybrid AF ablation as first procedure (non-paroxysmal AF 100%), 20 patients (16.7%) as second procedure (non-paroxysmal AF 30%), and 15 patients (12.5%) as third procedure (non-paroxysmal AF 33.3%). After a mean follow-up of 62.3 months ± 20.3, a total of 63 patients (52.5%) experienced ATas recurrence. Complications occurred in 12.5% of patients. There was no difference in ATas between patients undergoing hybrid as first vs. redo procedure (P = 0.53). Left atrial volume index and recurrence during blanking period were independent predictors of ATas recurrence. CONCLUSION: In a large cohort of patients undergoing hybrid AF ablation, the survival from ATas recurrence was 47.5% at ≈5 years follow-up. There was no difference in clinical outcomes between patients undergoing hybrid AF ablation as first procedure or as a redo.


Assuntos
Técnicas de Ablação , Fibrilação Atrial , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Seguimentos , Átrios do Coração , Estudos Retrospectivos , Taquicardia , Resultado do Tratamento
8.
Europace ; 26(1)2023 12 28.
Artigo em Inglês | MEDLINE | ID: mdl-38155611

RESUMO

AIMS: A novel sinus node (SN) sparing hybrid ablation for inappropriate sinus node tachycardia (IST)/postural orthostatic tachycardia syndrome (POTS) has been demonstrated to be an effective and safe therapeutic option in patients with symptomatic drug-resistant IST/POTS. The aim of this study was to evaluate the long-term rate of redo procedures after hybrid IST ablation and procedural strategy, outcomes and safety of redo procedures. METHODS AND RESULTS: All consecutive patients from 2015 to 2023 were prospectively enrolled in the UZ Brussel monocentric IST/POTS registry. They were analysed if the following inclusion criteria were fulfilled: 1) diagnosis of IST or POTS, 2) symptomatic IST/POTS refractory or intolerant to drugs, and 3) hybrid SN sparing ablation performed. The primary endpoint was redo procedure. The primary safety endpoint was pacemaker (PM) implantation. A total of 220 patients undergone to hybrid IST ablation were included, 185 patients (84.1%) were treated for IST and 61 patients (27.7%) for POTS.After a follow-up of 73.3 ± 16.2 months, 34 patients (15.4%) underwent a redo. A total of 23 patients (67.6%) had a redo for IST recurrence and 11 patients (32.4%) for other arrhythmias. Pacemaker implantation was performed in 21 patients (9.5%). Nine patients (4.1%) had no redo procedure and experienced sick sinus syndrome requiring a PM. Twelve patients (5.4%) received a PM as a shared therapeutic choice combined with SN ablation procedure. CONCLUSION: In a large cohort of patients the long-term free survival from redo procedure after hybrid IST ablation was 84.6% with a low PM implantation rate.


Assuntos
Ablação por Cateter , Taquicardia Sinusal , Humanos , Taquicardia Sinusal/diagnóstico , Taquicardia Sinusal/cirurgia , Taquicardia Sinusal/tratamento farmacológico , Nó Sinoatrial , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Frequência Cardíaca
9.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37061847

RESUMO

AIMS: A pathogenic/likely pathogenic (P/LP) variant in SCN5A is found in 20-25% of patients with Brugada syndrome (BrS). However, the diagnostic yield and prognosis of gene panel testing in paediatric BrS is unclear. The aim of this study is to define the diagnostic yield and outcomes of SCN5A gene testing with ACMG variant classification in paediatric BrS patients compared with adults. METHODS AND RESULTS: All consecutive patients diagnosed with BrS, between 1992 and 2022, were prospectively enrolled in the UZ Brussel BrS registry. Inclusion criteria were: (i) BrS diagnosis; (ii) genetic analysis performed with a large gene panel; and (iii) classification of gene variants following ACMG guidelines. Paediatric patients were defined as ≤16 years of age. The primary endpoint was ventricular arrhythmias (VAs). A total of 500 BrS patients were included, with 63 paediatric patients and 437 adult patients. Among children with BrS, 29 patients (46%) had a P/LP variant (P+) in SCN5A and no variants were found in 34 (54%) patients (P-). After a mean follow-up of 125.9 months, 8 children (12.7%) experienced a VA, treated with implanted cardioverter defibrillator shock. At survival analysis, P- paediatric patients had higher VA-free survival during the follow-up, compared with P+ paediatric patients. P+ status was an independent predictor of VA. There was no difference in VA-free survival between paediatric and adult BrS patients for both P- and P+. CONCLUSION: In a large BrS cohort, the diagnostic yield for P/LP variants in the paediatric population is 46%. P+ children with BrS have a worse arrhythmic prognosis.


Assuntos
Síndrome de Brugada , Adulto , Humanos , Criança , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/genética , Síndrome de Brugada/terapia , Testes Genéticos , Arritmias Cardíacas/genética , Cardioversão Elétrica , Prognóstico , Eletrocardiografia/métodos , Canal de Sódio Disparado por Voltagem NAV1.5/genética
10.
Europace ; 26(1)2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-38245007

RESUMO

AIMS: Pulsed field ablation (PFA) has emerged as a novel, non-thermal energy source to selectively ablate cardiac tissue. We describe a multicentre experience on pulmonary vein isolation (PVI) via the pentaspline Farapulse™ PFA system vs. thermal-based technologies in a propensity score-matched population of paroxysmal atrial fibrillation (PAF) patients. METHODS AND RESULTS: Propensity score matching was adopted to compare PVI-only ablation outcomes via the Farawave™ system (Group PFA), cryoballoon (Group CRYO), or focal radiofrequency (Group RF) (PFA:CRYO:RF ratio = 1:2:2). Among 1572 (mean age: 62.4 ± 11.3 years; 42.5% females) PAF patients undergoing first time PVI with either PFA (n = 174), CRYO (n = 655), or RF (n = 743), propensity score matching yielded 174 PFA, 348 CRYO, and 348 RF patients. First-pass isolation was achieved in 98.8% of pulmonary veins (PVs) with PFA, 81.5% with CRYO, and 73.1% with RF (P < 0.001). Procedural and dwell times were significantly shorter with PFA, whereas the availability of a 3D mapping system led to a significant reduction in X-ray exposure with RF. Overall complication rates were 3.4% (n = 6) with PFA, 8.6% (n = 30) with CRYO, and 5.5% (n = 19) with RF (P = 0.052). The 1-year Kaplan-Meier estimated freedom from any atrial tachyarrhythmia was 79.3% with PFA, 74.7% with CRYO, and 72.4% with RF (log-rank P-value: 0.24). Among 145 repeat ablation procedures, PV reconnection rate was 19.1% after PFA, 27.5% after CRYO, and 34.8% after RF (P = 0.01). CONCLUSION: Pulsed field ablation contributed to significantly shorter procedural times. Follow-up data showed a similar arrhythmia freedom, although a higher rate of PV reconnection was documented in post-CRYO and post-RF redo procedures.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Pontuação de Propensão , Resultado do Tratamento , Átrios do Coração , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
11.
Clin Auton Res ; 33(1): 51-62, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36645559

RESUMO

PURPOSE: Drug-induced type I Brugada syndrome (BrS) is associated with a ventricular arrhythmia (VA) rate of 1 case per 100 person-years. This study aims to evaluate changes in electrocardiographic (ECG) parameters such as microvolt T wave alternans (mTWA) and heart rate variability (HRV) at baseline and during ajmaline testing for BrS diagnosis. METHODS: Consecutive patients diagnosed with BrS during ajmaline testing with 5-year follow-up were included in this study. For comparison, a negative ajmaline control group and an isoproterenol control group were also included. ECG recordings during ajmaline or isoproterenol test were divided in two timeframes from which ECG parameters were calculated: a 5-min baseline timeframe and a 5-min drug timeframe. RESULTS: A total of 308 patients with BrS were included, 22 (0.7%) of which suffered VAs during follow-up. One hundred patients were included in both isoproterenol and negative ajmaline control groups. At baseline, there was no difference in ECG parameters between control groups and patients with BrS, nor between BrS with and without VAs. During ajmaline testing, BrS with VAs presented longer QRS duration [159 ± 34 ms versus 138 (122-155) ms, p = 0.006], higher maximum mTWA [33.8 (14.0-114) µV versus 8.00 (3.67-28.2) µV, p = 0.001], and lower power in low frequency band [25.6 (5.8-53.8) ms2 versus 129.5 (52.7-286) ms2, p < 0.0001] when compared to BrS without VAs. CONCLUSIONS: Ajmaline induced important HRV changes similar to those observed during isoproterenol. Increased mTWA was observed only in patients with BrS. BrS with VAs during follow-up presented worse changes during ajmaline test, including lower LF power and higher maximum mTWA which were independent predictors of events.


Assuntos
Ajmalina , Síndrome de Brugada , Humanos , Ajmalina/farmacologia , Síndrome de Brugada/diagnóstico , Frequência Cardíaca , Isoproterenol , Arritmias Cardíacas , Eletrocardiografia , Prognóstico
12.
Heart Vessels ; 38(6): 757-763, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36607386

RESUMO

To evaluate coronary artery disease (CAD) with computed tomography coronary angiography (CTCA)-derived fractional flow reserve (FFR) in patients with atrial fibrillation (AF) requiring ablation. The study population consisted of 151 patients who underwent CTCA before AF ablation (AF group), and a control group of 151 patients from the outpatient clinic who underwent CTCA without any history of AF (non-AF group), matched for age, sex, BMI, and angina symptomatology. All study patients underwent CTCA with subdivision of coronary lesion type into severe (≥ 70% luminal narrowing), moderate (50% ≤ luminal narrowing < 70%), and mild stenosis (< 50% luminal narrowing). In patients with ≥ 1 moderate or severe stenosis, non-invasive FFR was calculated from CTCA (FFRCT). Baseline characteristics and CAD risk factors were similar between the 2 groups. During CTCA, 38% of the patients in the AF group were in ongoing atrial arrhythmia (either AF or regular atrial tachycardia). The number of patients with severe (10 (6.6%) vs 10 (6.6%), P = 1.00), moderate (14 (9.5%) vs 10 (6.7%), P = 0.4), and mild stenosis (43 (28.5%) vs 56 (37.1%), P = 0.11) was not significantly different between the 2 groups. Performance of FFRCT was feasible in 32/44 patients (73%), and failed in 27% of the patients (7 and 5 patients in the AF and non-AF group, respectively, P = 0.74). No difference was observed in the prevalence of hemodynamically significant stenosis (FFRCT ≤ 0.80) (15 (9.9%) vs 12 (7.9%), P = 0.85). Our study showed technical feasibility of CTCA in all patients of both groups, including the patients with AF as presenting rhythm. The FFRCT add-on analysis failed equally frequent in patients of the AF versus non-AF group. An equal rate of CAD was observed in the AF group and non-AF group, favoring the concept of shared associated risk factors for CAD and AF.


Assuntos
Fibrilação Atrial , Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Constrição Patológica , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X/métodos , Angiografia por Tomografia Computadorizada/métodos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/cirurgia , Valor Preditivo dos Testes , Vasos Coronários
13.
Pacing Clin Electrophysiol ; 45(5): 605-611, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35352363

RESUMO

BACKGROUND: Left atrial posterior wall isolation (LAPWI) is often performed in addition to pulmonary vein isolation (PVI) in the setting of persistent atrial fibrillation (AF) ablation. The aim of this study was to evaluate the feasibility and safety of a new cryoballoon ablation system in achieving PVI + LAPWI isolation. METHODS: The study was a prospective, non-randomized, single center study. Forty consecutive patients, undergoing PVI + LAPWI with the novel POLARx™, were compared to 40 consecutive patients who underwent the same procedure with the established Arctic Front Advance PRO™. RESULTS: Acute isolation was achieved in all PVs in both groups and left posterior wall isolation (LAPWI) was achieved in 38 patients (95%) in the POLARx group and in 36 patients (90%) in Arctic Front group. Procedural outcomes were similar between both groups, except for lower temperatures during cryoenergy in the POLARx group, for both pulmonary vein isolation (PVI) and LAPWI. CONCLUSION: LAPWI + PVI with the novel POLARx™ Cryoballoon is feasible and safe; the results are comparable with the Arctic Front Advance PRO™ system.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Estudos de Viabilidade , Humanos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Tecnologia , Resultado do Tratamento
14.
Pacing Clin Electrophysiol ; 44(12): 2075-2083, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34773413

RESUMO

BACKGROUND: Pulmonary vein (PV) isolation is an established treatment for paroxysmal drug-refractory atrial fibrillation (AF). High parasympathetic tone and reconnection of PVs have demonstrated to be possible culprits of AF recurrence after ablation. Our aim was to investigate the association between parasympathetic tone and reconnected PVs in patients with paroxysmal AF. METHODS: Consecutive patients who underwent a redo catheter ablation procedure for atrial tachyarrhythmia recurrence by means of 3D electroanatomic mapping with documentation of presence or absence of PVs reconnection following an initial procedure of cryoballoon (CB) ablation for symptomatic drug-refractory paroxysmal AF were screened for the study. RESULTS: A total of 92 patients were included, of whom 50 (54.35%) were males. Reconnected PVs were found in 64 (69%) patients. PVs reconnection could be predicted by DC (C-statistic = .770), by SDNNI (C-statistic = .714) and by absolute VLF power (C-statistic = .722), while right-sided PVs reconnection could be better predicted by DC (C-statistic = .848) and by SDNNI (C-statistic = .761). In multivariate binary logistic regression analysis, a DC value ≥6.45 ms and an absolute VLF power value ≥160 ms2 were associated with three times and five times higher odds of PVs reconnection, respectively. On a vein-per-vein analysis, absolute VLF power ≥160 ms2 was associated with three times higher odds, while reaching of -40°C within 60 s was associated with three times lower odds of PVs reconnection. CONCLUSION: High parasympathetic tonus accurately predicts PVs reconnection. On a vein-per-vein analysis, parasympathetic markers along with biophysical parameters predicted PVs reconnection. On a case-by-case analysis, parasympathetic markers were the only predictors of PVs reconnection, thus being a robust PVs reconnection prediction tool.


Assuntos
Fibrilação Atrial/cirurgia , Sistema Nervoso Autônomo/fisiopatologia , Criocirurgia/métodos , Veias Pulmonares/cirurgia , Nervo Vago/fisiopatologia , Adulto , Mapeamento Epicárdico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Reoperação
15.
J Cardiovasc Electrophysiol ; 31(1): 128-136, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31749209

RESUMO

AIM: The aim of this study is to assess specific per-vein procedural predictors of pulmonary vein (PV) late reconnection in cryoballoon ablation (CbA) METHODS AND RESULTS: We enrolled 148 consecutive patients undergoing a redo procedure after a previous index CbA in our center. A reconnection in at least one PV was found in 80 patients (54.1%) and the most frequently reconnected PV was the right inferior pulmonary vein (RIPV). Overall, pulmonary vein reconnection (PVr) was associated with longer time to -40°C (Tt-40°C) (54.4 ± 21.7 vs 67.6 ± 27.6 seconds; P < .001), warmer nadir temperature (NT) (-49.7°C ± 5.4°C vs -46.5°C ± 5.8°C; P < .001) and temperature at 60 seconds (-41.8°C ± 4.5°C vs -39.8°C ± 4.2°C; P < .001). The performance of these predictors differed between the veins. In particular, a comparable behavior was observed for left superior pulmonary vein (LSPV) and right superior pulmonary vein (RSPV), where NT ≤ -48°C showed a sensibility and a specificity, respectively, of 62% and 65% and 71% and 72% in predicting durable PV isolation. For RIPV, NT ≤ -48°C showed a sensitivity of 74% but low specificity (53%). Tt -40°C less than 60 seconds showed good negative predictive values, respectively, 83.9% for LSPV, 94.9% for left inferior pulmonary vein (LIPV), 90.2% for RSPV, and 82.7% for RIPV. Previous predictors cannot be used for LIPV. CONCLUSIONS: Freezing behavior and reconnection rates differ significantly among the four PVs. Freezing temperature parameters strongly predict late PVr in superior PVs and are slightly different in RIPV but can be applied as well. LIPV freezing behavior is the most different. Its reconnection is uncommon even in the subset of worse freezing temperatures and specific CB predictors cannot be identified.


Assuntos
Potenciais de Ação , Fibrilação Atrial/cirurgia , Criocirurgia/instrumentação , Veias Pulmonares/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Criocirurgia/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Veias Pulmonares/fisiopatologia , Recidiva , Reoperação , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
16.
J Cardiovasc Electrophysiol ; 31(3): 629-637, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31943519

RESUMO

AIM: The aim of the study was to investigate the role of anatomical characteristics of the pulmonary veins (PVs) determining cooling kinetics during second-generation cryoballoon ablation (CbA). METHODS AND RESULTS: we enrolled all consecutive patients who underwent CbA for symptomatic atrial fibrillation in our center from January 2019 to March 2019. All patients had complete computed tomography scans of the heart before the ablation. Anatomical characteristics were tested for prediction of a nadir temperature (NT) ≤ -48°C. Significant differences were noted among PV max diameter (20.8 ± 2.8 vs 18.5 ± 2.5 mm; P < .001); PV minimum diameter (15.2 ± 3.0 vs 13.0 ± 3.1 mm; P < .001); PV area (268.1 ± 71.9 vs 206.2 ± 58.7 mm2 ; P < .001); PV ovality (1.4 ± 0.3 vs 1.5 ± 0.3; P = .005); and PV trunk length (27.4 ± 7.4 vs 21.3 ± 6.5 mm; P < .001). A scoring system was created by assigning one point each ranging from 0 (best anatomical combination) to 5. In the group with a score of 0, 94.0% of the CbA could reach a NT ≤ -48°C whereas with a score of 5, only 29.0% (P < .001). Left superior pulmonary vein with short trunk length and acute angle of PV branch was significantly associated with warmer NT (11.8% satisfactory CbA; P = .003). Regarding right inferior pulmonary vein, trunk length (P = .004), maximum diameter (P = .044), and transverse angle (P = .008) were independently associated with good NT. CONCLUSION: Anatomical PV features are associated with cooling kinetics and an anatomical score could predict lower NT during second-generation CbA. Specific characteristics were identified for inferior PV. Although heart imaging is not mandatory prior CbA, it can be a useful tool to predict cooling kinetics.


Assuntos
Fibrilação Atrial/cirurgia , Temperatura Baixa , Criocirurgia , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Temperatura Baixa/efeitos adversos , Angiografia por Tomografia Computadorizada , Criocirurgia/efeitos adversos , Feminino , Humanos , Cinética , Masculino , Pessoa de Meia-Idade , Flebografia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Estudos Retrospectivos , Resultado do Tratamento
17.
Indian Pacing Electrophysiol J ; 20(4): 154-159, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32224089

RESUMO

BACKGROUND: Clinical management of vaso-vagal syncope (VVS) remains challenging since no therapy has proven to completely prevent VVS recurrence. OBJECTIVE: The purpose of this study was to analyze the mid-term outcome of cryoballoon (CB) cardioneuroablation achieved by pulmonary vein isolation (PVI) in patients with VVS. METHODS: Patients who underwent CB cardioneuroablation in our centers between January 2014 to June 2018 were included. All patients had a history of VVS or pre-syncope despite therapeutic attempts with medical and/or pacing treatments. Patients were excluded in case of structural heart diseases, cerebrovascular diseases or suspected drug-related syncope. Both heart rate (HR) and atrio-ventricular (AV) interval were analyzed on the 12-lead electrocardiogram (ECG) the day before the procedure, the day after, and in the follow-up. RESULTS: In total, 26 patients (76.9% males, 37.5 ± 9.0 years old) were included. All patients underwent a successful procedure with the 28 mm second-generation Arctic Front Advance CB. No major complication occurred. At a mean follow-up of 20.1 ± 11.6 months the freedom from VVS or reflex pre-syncope was 83,7%, with 22 patients free from any clinical recurrence. Basal HR significantly increased the day after the procedure (57.2 bpm vs 78.3 bpm, p < 0.001), while at the final follow-up it stabilized at a value halfway between the 2 previous ones (69.8 bpm, p = 0.0086). The AV interval didn't modify significantly after the procedure. CONCLUSION: Endocardial autonomic denervation achieved by CB PVI appears to be an effective and safe treatment option for patients with refractory VVS and reflex pre-syncope.

18.
J Cardiovasc Electrophysiol ; 30(11): 2294-2301, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31535750

RESUMO

INTRODUCTION: The right inferior pulmonary vein (RIPV) accounts as the most frequently reconnected vein after pulmonary vein isolation using second-generation cryoballoon ablation (CB-A). Our objective was to assess anatomic predictors of late RIPV reconnection based on preprocedural computed tomography scan. METHODS: Patients with a repeat procedure for atrial tachyarrhythmia recurrence after index CB-A procedure were included. A total of 129 RIPVs were evaluated for ostial diameters, ostial area, and branching pattern. Interior angle between RIPV and horizontal line in the frontal/transversal plane was used to measure the RIPV orientation: RIPV frontal/transversal angle, respectively. In addition, interior angle between RIPV and the line perpendicular on the septal intersection line at the level of the fossa ovalis, estimated as trans-septal (TS) puncture site, was measured in the frontal/transversal view: RIPV-TS frontal/transversal angle, respectively. RESULTS: Late vein reconnection was present in 36/129 RIPVs (28%). Warmer balloon nadir temperature (P = .01), more inferior (P < .001) and posterior (P < .01) RIPV orientation (ie, more positive RIPV frontal and RIPV transversal angle, respectively), and sharper RIPV-TS frontal angle (P < .001) were associated with late RIPV reconnection on univariate analysis. Independent variables after multivariate analysis were nadir temperature (odds ratio [OR], 1.12; 95% confidence interval [CI], 1.03-1.23; P = .013) and RIPV frontal angle (OR, 1.13, CI, 1.07-1.19; P < .001). CONCLUSION: Frontal RIPV orientation could significantly predict late RIPV electrical reconnection after CB-A. Therefore, preprocedural anatomic assessment of the RIPV might be useful to plan the correct ablation strategy.


Assuntos
Criocirurgia/efeitos adversos , Veias Pulmonares/cirurgia , Taquicardia Supraventricular/cirurgia , Potenciais de Ação , Idoso , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Recidiva , Fatores de Risco , Taquicardia Supraventricular/diagnóstico por imagem , Taquicardia Supraventricular/fisiopatologia , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
19.
Europace ; 21(3): 434-439, 2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30010776

RESUMO

AIMS: Vascular complications are the most common complications of atrial fibrillation (AF) ablation. Cryoballoon (CB) ablation for AF needs the insertion of a large 15 Fr sheath in the femoral vein. Our aim was to investigate the impact of vascular ultrasound (US) in guiding access and evaluating post-procedural subclinical complications in a large, multi-centre patient cohort that underwent CB ablation. METHODS AND RESULTS: A total cohort of 1435 consecutive patients were subdivided in 870 US -/-, 265 US -/+, and 300 US +/+ patients depending on US performance for: venipuncture guidance/post-procedural evaluation. Major clinical complications (requiring intervention and/or prolonged stay) were assessed. Irrespective of the clinical status, major US events were systematically determined in the subgroups with US evaluation 1 day post-procedure, if evidence of inadvertent artery puncture/cannulation (communication between artery and collection or artery-vein, regardless of the thrombosis state). Major clinical events were encountered in 1.7% (15/870), 1.1% (3/265), and 0% of patients in US -/-, US -/+, and US +/+ group, respectively (P = 0.02 between US -/- and US +/+ group). In the US -/- group, 5/10 (50%) of pseudo-aneurysms were diagnosed during readmission after a mean of 24 ± 11 days post-procedure. No delayed presentation was seen in the US -/+ group. Major US events during the US protocol post-procedure were seen in 3.8% (10/265) vs. 0.3% (1/300) of patients in US -/+ vs. US +/+ group, respectively, P = 0.004. CONCLUSION: US-guided venipuncture was associated with a near-to-zero risk of vascular complications in our patients undergoing CB ablation.


Assuntos
Fibrilação Atrial/cirurgia , Cateterismo Periférico , Criocirurgia , Veia Femoral/diagnóstico por imagem , Ultrassonografia de Intervenção , Doenças Vasculares/prevenção & controle , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Bélgica , Cateterismo Periférico/efeitos adversos , Criocirurgia/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Punções , Medição de Risco , Fatores de Risco , Resultado do Tratamento , Doenças Vasculares/diagnóstico por imagem , Doenças Vasculares/etiologia
20.
Pacing Clin Electrophysiol ; 42(7): 868-873, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31037747

RESUMO

BACKGROUND: In the setting of second-generation cryoballoon (CB2) ablation, left atrial (LA) access is generally achieved using a standard sheath (SS) that is exchanged for the 15Fr cryoballoon delivery sheath (CBS) and dilator over a long wire (CBS over-the-wire technique, CBS-W). Our objective was to evaluate the direct use of the CBS to gain LA access, by advancing the latter over the trans-septal needle (CBS over-the-needle technique, CBS-N), under transesophageal echocardiographic (TEE) guidance. METHODS: Consecutive patients who underwent CB2 ablation with the CBS-N technique were evaluated for feasibility of gaining LA access using TEE guidance and fluoroscopy views. Complications related to the LA access were compared with a matched CBS-W control group. Subanalysis (30 CBS-W vs 30 CBS-N patients) evaluated time-to-LA of the CBS: time from superior vena cava (with SS vs CBS) to LA insertion of the CBS, after exchange or directly, respectively. RESULTS: LA access could be achieved in all 505 patients of the CBS-N group, without technique modification or additional equipment. Challenging interatrial septa were noted in 13% of these patients: previous atrial septal defect repair (1%), hypermobile (10%), aneurysmal (1%), and abnormally thickened/fibrotic (1%). Incidence of complications was similar to the CBS-W group. Subanalysis showed a shorter time-to-LA in the CBS-N versus CBS-W group, 72 ± 46 seconds versus 293 ± 180 seconds, P < .001. CONCLUSIONS: Our study showed that the CBS-N technique is feasible and safe under echocardiographic guidance. Without sheath exchange, it simplifies the CB2 procedure, is less costly, time sparing, and might reduce the risk of air embolism.


Assuntos
Fibrilação Atrial/cirurgia , Septo Interatrial/cirurgia , Oclusão com Balão/instrumentação , Criocirurgia/instrumentação , Agulhas , Veias Pulmonares/cirurgia , Bélgica , Ecocardiografia , Estudos de Viabilidade , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA