1.
Clin Chem ; 68(4): 511-520, 2022 03 31.
Artigo em Inglês | MEDLINE | ID: mdl-34918062

RESUMO

Recognizing that race is a social and not a biological construct, healthcare professionals and the public have called for removal of race in clinical algorithms. In response, the National Kidney Foundation and the American Society of Nephrology created the Task Force on Reassessing the Inclusion of Race in Diagnosing Kidney Diseases to examine the issue and provide recommendations. The final report from the Task Force recommends calculating estimated glomerular filtration rate (eGFR) without a race coefficient using the recently published CKD-EPI 2021 creatinine (cr) and creatinine-cystatin C (cr-cys) equations. The Task Force recommends immediately replacing older eGFRcr equations (MDRD Study and CKD-EPI 2009) with the new CKD-EPI 2021 equation. In a 2019 survey by the College of American Pathologists, 23% of 6200 laboratories reporting eGFRcr used an incorrect equation that is not suitable for use with standardized creatinine measurements, 34% used the CKD-EPI 2009 equation and 43% used the MDRD Study 2006 equation re-expressed for standardized creatinine measurement. Rapid transition to using the CKD-EPI 2021 equation is an opportunity for laboratories to standardize to a single equation to eliminate differences in eGFRcr due to different equations used by different laboratories, and to report eGFR without use of race. We provide guidance to laboratories for implementing the CKD-EPI 2021 equations for both eGFRcr and eGFRcr-cys.


Assuntos
Laboratórios , Insuficiência Renal Crônica , Creatinina , Taxa de Filtração Glomerular/fisiologia , Humanos , Rim , Laboratórios Clínicos , Insuficiência Renal Crônica/diagnóstico
2.
Clin Chem ; 65(11): 1397-1404, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31570632

RESUMO

BACKGROUND: Measurement of plasma adrenocorticotropic hormone (ACTH) is key in the differential diagnosis of hypothalamic-pituitary-adrenal disorders. Two-site sandwich immunoassays dominate clinical testing of ACTH in North America; however, discordant results between manufacturers have been repeatedly reported. To resolve the discrepancy, we developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for the intended measurand, biologically active intact ACTH (iACTH). METHODS: The multiple reaction monitoring LC-MS/MS assay was designed to selectively measure full-length iACTH, as well as ACTH analogs and fragments (i.e., ACTH1-24 and ACTH18-39). Epitope assignment of the Roche Elecsys antibodies was performed by MALDI-TOF mass spectrometry. A method comparison between Roche Elecsys and Siemens Immulite ACTH immunoassays was performed and clinically concordant/discordant results identified. In a subset of these samples, the iACTH concentration was determined using the LC-MS/MS method. RESULTS: The lower limit of the measuring interval of the iACTH LC-MS/MS assay was 9 pg/mL (2 pmol/L). The assay was linear from 9 to 1938 pg/mL (2 to 427 pmol/L). Epitope mapping revealed that the Roche capture and detection antibodies bound residues 9-12 and 36-39 of ACTH, respectively. The iACTH LC-MS/MS analysis demonstrated that for discordant results between 2 immunoassays studied, only the Roche results were highly positively correlated with the iACTH concentration. CONCLUSIONS: Immunoprecipitation of biologically active ACTH molecules followed by LC-MS/MS analysis enabled selective detection of iACTH and relevant biologically active fragments in plasma. Applied to the investigation of clinically discrepant results, this method can act as an arbiter of the concentration of iACTH present.


Assuntos
Hormônio Adrenocorticotrópico/sangue , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Hormônio Adrenocorticotrópico/química , Hormônio Adrenocorticotrópico/imunologia , Sequência de Aminoácidos , Anticorpos Monoclonais/imunologia , Humanos , Imunoensaio/estatística & dados numéricos , Imunoprecipitação , Alinhamento de Sequência
4.
Clin Chem ; 62(1): 218-26, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26578690

RESUMO

INTRODUCTION: Parathyroid hormone-related peptide (PTHrP) is involved in activating pathways, allowing tumor cells to form bone metastases. Measurement of PTHrP is used for the diagnosis and clinical management of patients suspected of hypercalcemia of malignancy. We developed an LC-MS/MS method for measuring PTHrP, established sex-specific reference intervals, and assessed the method's performance. METHODS: PTHrP was enriched from plasma samples with rabbit polyclonal anti-PTHrP antibody conjugated to magnetic beads. Enriched PTHrP was digested with trypsin, and PTHrP-specific tryptic peptide was analyzed with 2-dimensional LC-MS/MS in multiple reaction monitoring mode. RESULTS: The lower limit of quantification was 0.6 pmol/L, and the upper limit of linearity was 600 pmol/L. Total imprecision was <10%. Very poor agreement was observed with the RIA (n = 207; Deming regression RIA = 0.059 × LC-MS/MS - 1.8, r = 0.483; Sy|x = 3.9). Evaluation of the clinical performance of the assay using samples from patients with and without hypercalcemia (n = 199) resulted in an area under the ROC curve of 0.874. In sets of consecutively analyzed routine samples of patients assessed for hypercalcemia, the PTHrP positivity rate by RIA (n = 1376) was 1.9%, and 26.6% by LC-MS/MS (n = 1705). Concentrations were below the lower limit of quantification in 95.6% of the samples by RIA and 2.0% by LC-MS/MS. CONCLUSIONS: PTHrP is a normal constituent in circulating blood and its concentrations are substantially underestimated by commercial RIAs, causing false-negative results in samples from patients suspected of hypercalcemia. Our observations suggest a link between increased concentrations of PTHrP in postmenopausal women with low body mass index and increased incidence of osteoporosis.


Assuntos
Proteína Relacionada ao Hormônio Paratireóideo/sangue , Espectrometria de Massas em Tandem , Adulto , Idoso , Cromatografia Líquida de Alta Pressão , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
5.
Clin Lab ; 61(3-4): 283-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25974994

RESUMO

BACKGROUND: Vitamin B12 (cobalamin) is a necessary cofactor in methionine and succinyl-CoA metabolism. Studies estimate the deficiency prevalence as high as 30% in the elderly population. Ten to thirty percent of circulating cobalamin is bound to transcobalamin (holotranscobalamin, holoTC) which can readily enter cells and is therefore considered the bioactive form. The objective of our study was to evaluate the analytical performance of a high-throughput, automated holoTC assay (ARCHITECT i2000(SR) Active-B12 (Holotranscobalamin)) and compare it to other available methods. METHODS: Manufacturer-specified limits of blank (LoB), detection (LoD), and quantitation (LoQ), imprecision, interference, and linearity were evaluated for the ARCHITECT HoloTC assay. Residual de-identified serum samples were used to compare the ARCHITECT HoloTC assay with the automated AxSYM Active-B12 (Holotranscobalamin) assay (Abbott Diagnostics) and the manual Active-B12 (Holotranscobalamin) Enzyme Immunoassay (EIA) (Axis-Shield Diagnostics, Dundee, Scotland, UK). RESULTS: Manufacturer's claims of LoB, LoD, LoQ, imprecision, interference, and linearity to the highest point tested (113.4 pmol/L) were verified for the ARCHITECT HoloTC assay. Method comparison of the ARCHITECT HoloTC to the AxSYM HoloTC produced the following Deming regression statistics: (ARCHITECT(HoloTc)) = 0.941 (AxSYM(HoloTC)) + 1.2 pmol/L, S(y/x) = 6.4, r = 0.947 (n = 98). Comparison to the Active-B12 EIA produced: (ARCHITECT(HoloTC)) = 1.105 (EIA(Active-B12)) - 6.8 pmol/L, S(y/x) = 11.0, r = 0.950 (n = 221). CONCLUSIONS: This assay performed acceptably for LoB, LoD, LoQ, imprecision, interference, linearity and method comparison to the predicate device (AxSYM). An additional comparison to a manual Active-B12 EIA method performed similarly, with minor exceptions. This study determined that the ARCHITECT HoloTC assay is suitable for routine clinical use, which provides a high-throughput alternative for automated testing of this emerging marker of cobalamin deficiency.


Assuntos
Ensaios de Triagem em Larga Escala/métodos , Deficiência de Vitamina B 12/sangue , Acil Coenzima A/química , Automação , Biomarcadores/sangue , Humanos , Técnicas Imunoenzimáticas/métodos , Limite de Detecção , Metionina/química , Reprodutibilidade dos Testes , Transcobalaminas/química , Complexo Vitamínico B/sangue
7.
J Endocr Soc ; 8(6): bvae069, 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38698869

RESUMO

Context: The Roche prolactin immunoassay is used throughout the world. It reports higher values than the Siemens immunoassay but the manufacturer-defined reference intervals are similar. Patient results are often above the Roche upper limit but within the Siemens interval, causing diagnostic confusion. Objective: Establish new reference intervals for the Roche and Siemens prolactin immunoassays. Methods: We established new reference intervals for the Roche and Siemens immunoassays using 374 specimens from healthy outpatients. We performed chart review for unnecessary testing and treatment for 298 patients in a 6-month period with at least 1 Roche prolactin value above the manufacturer-defined upper limit and below our new upper limit. Results: The new upper limit for the Roche assay was 37.8 ng/mL (females) and 22.8 ng/mL (males). The manufacturer-defined limits were 23.3 ng/mL and 15.2 ng/mL, respectively. New intervals for the Siemens assay matched the manufacturer. No cases of clinically significant pathophysiologic prolactin excess were identified in patients with values between the manufacturer-defined upper reference limit and our new Roche upper limit. Unnecessary further evaluation in these patients included 459 repeat prolactin measurements, 57 macroprolactin measurements, 39 magnetic resonance imaging studies, and 28 endocrine referrals. Eleven patients received dopamine agonists. The minimum cost of excess care using Medicare reimbursement rates was $34 134, with substantially higher amounts billed to patients and their insurance providers. Conclusion: Adoption of new upper reference limits for the Roche prolactin assay of 37.8 ng/mL (females) and 22.8 ng/mL (males) would not delay diagnosis or necessary intervention in patients with clinically significant pituitary tumors but would reduce unnecessary evaluation in patients without pathophysiologic prolactin excess.

8.
J Appl Lab Med ; 7(1): 206-220, 2022 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-34996091

RESUMO

BACKGROUND: Autoimmune endocrine diseases can be thought of as a case of mistaken identity. The immune system mistakenly attacks one's own cells, as if they were foreign, which typically results in endocrine gland hypofunction and inadequate hormone production. Type 1 diabetes mellitus and autoimmune thyroid disorders (Hashimoto and Graves diseases) are the most common autoimmune endocrine disorders, while conditions such as Addison disease are encountered less frequently. Autoantibody production can precede clinical presentation, and their measurement may aid verification of an autoimmune process and guide appropriate treatment modalities. CONTENT: In this review, we discuss type 1 diabetes mellitus, autoimmune thyroid disorders, and Addison disease, emphasizing their associated autoantibodies and methods for clinical detection. We will also discuss efforts to standardize measurement of autoantibodies. CONCLUSIONS: Autoimmune endocrine disease progression may take months to years and detection of associated autoantibodies may precede clinical onset of disease. Although detection of autoantibodies is not necessary for diagnosis, they may be useful to verify an autoimmune process.


Assuntos
Doenças Autoimunes , Diabetes Mellitus Tipo 1 , Doenças do Sistema Endócrino , Doença de Graves , Autoanticorpos , Doenças Autoimunes/diagnóstico , Doenças do Sistema Endócrino/diagnóstico , Doença de Graves/diagnóstico , Humanos
9.
Ann Surg ; 253(4): 672-83, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21475006

RESUMO

OBJECTIVE: The goal of this study was to assess the immunogenicity and antigenicity of StrataGraft skin tissue in a randomized phase I/II clinical trial for the temporary management of full-thickness skin loss. BACKGROUND: StrataGraft skin tissue consists of a dermal equivalent containing human dermal fibroblasts and a fully stratified, biologically active epidermis derived from Near-diploid Immortalized Keratinocyte S (NIKS) cells, a pathogen-free, long-lived, consistent, human keratinocyte progenitor. METHODS: Traumatic skin wounds often require temporary allograft coverage to stabilize the wound bed until autografting is possible. StrataGraft and cadaveric allograft were placed side by side on 15 patients with full-thickness skin defects for 1 week before autografting. Allografts were removed from the wound bed and examined for allogeneic immune responses. Immunohistochemistry and indirect immunofluorescence were used to assess tissue structure and cellular composition of allografts. In vitro lymphocyte proliferation assays, chromium-release assays, and development of antibodies were used to examine allogeneic responses. RESULTS: One week after patient exposure to allografts, there were no differences in the numbers of T or B lymphocytes or Langerhans cells present in StrataGraft skin substitute compared to cadaver allograft, the standard of care. Importantly, exposure to StrataGraft skin substitute did not induce the proliferation of patient peripheral blood mononuclear cells to NIKS keratinocytes or enhance cell-mediated lysis of NIKS keratinocytes in vitro. Similarly, no evidence of antibody generation targeted to the NIKS keratinocytes was seen. CONCLUSIONS: These findings indicate that StrataGraft tissue is well-tolerated and not acutely immunogenic in patients with traumatic skin wounds. Notably, exposure to StrataGraft did not increase patient sensitivity toward or elicit immune responses against the NIKS keratinocytes. We envision that this novel skin tissue technology will be widely used to facilitate the healing of traumatic cutaneous wounds.This study was registered at www.clinicaltrials.gov (NCT00618839).


Assuntos
Transplante de Pele/métodos , Pele Artificial , Pele/lesões , Lesões dos Tecidos Moles/cirurgia , Cicatrização/fisiologia , Adulto , Idoso , Cadáver , Procedimentos Cirúrgicos Dermatológicos , Feminino , Seguimentos , Rejeição de Enxerto , Sobrevivência de Enxerto , Humanos , Escala de Gravidade do Ferimento , Queratinócitos/transplante , Masculino , Dose Máxima Tolerável , Pessoa de Meia-Idade , Estudos Prospectivos , Transplante de Pele/imunologia , Lesões dos Tecidos Moles/imunologia , Imunologia de Transplantes/fisiologia , Transplante Autólogo , Transplante Homólogo
10.
Clin Chem ; 57(11): 1566-73, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21920914

RESUMO

BACKGROUND: Although measurement of whole-blood creatinine at the point of care offers rapid assessment of renal function, agreement of point-of-care (POC) results with central laboratory methods continues to be a concern. We assessed the influence of several potential interferents on POC whole-blood creatinine measurements. METHODS: We compared POC creatinine (Nova StatSensor) measurements with plasma enzymatic (Roche Modular) and isotope dilution mass spectrometry (IDMS) assays in 119 hospital inpatients. We assessed assay interference by hematocrit, pH, pO(2), total and direct bilirubin, creatine, prescribed drugs, diagnosis, red blood cell water fraction, and plasma water fraction. RESULTS: CVs for POC creatinine were 1.5- to 6-fold greater than those for plasma methods, in part due to meter-to-meter variation. Regressioncomparison of POC creatinine to IDMS results gave a standard error (S(y|x)) of 0.61 mg/dL (54 µmol/L), whereas regression of plasma enzymatic creatinine to IDMS was S(y|x) 0.16 mg/dL (14 µmol/L). By univariate analysis, bilirubin, creatine, drugs, pO(2), pH,plasma water fraction, and hematocrit were not found to contribute to method differences. However, multivariate analysis revealed that IDMS creatinine, red blood cell and plasma water fractions, and hematocrit explained 91.8% of variance in POC creatinine results. CONCLUSIONS: These data suggest that whole-blood POC creatinine measurements should be used with caution. Negative interferences observed with these measurements could erroneously suggest adequate renal function near the decision threshold, particularly if estimated glomerular filtration rate is determined. Disparity between whole-blood and plasma matrices partially explains the discordance between whole-blood and plasma creatinine methods.


Assuntos
Creatinina/sangue , Sistemas Automatizados de Assistência Junto ao Leito , Enzimas , Reações Falso-Negativas , Feminino , Taxa de Filtração Glomerular , Humanos , Técnicas de Diluição do Indicador , Indicadores e Reagentes , Pacientes Internados , Unidades de Terapia Intensiva , Nefropatias/sangue , Nefropatias/diagnóstico , Modelos Lineares , Masculino , Espectrometria de Massas , Pessoa de Meia-Idade , Análise Multivariada , Serviço Hospitalar de Oncologia , Sistemas Automatizados de Assistência Junto ao Leito/normas , Padrões de Referência
11.
J Appl Lab Med ; 6(3): 614-624, 2021 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-33064790

RESUMO

BACKGROUND: As serologic assays for SARS-CoV-2 become more widely utilized, it is important to understand their performance characteristics and correlation with neutralizing antibodies. We evaluated 3 commonly used SARS-CoV-2 IgG assays (Abbott, DiaSorin, and EUROIMMUN) for clinical sensitivity, specificity, and correlation with neutralizing antibodies, and then compared antibody kinetics during the acute phase of infection. METHODS: Three panels of samples were tested on every assay. Sensitivity was assessed using a panel of 35 specimens serially collected from 7 patients with RT-PCR-confirmed COVID-19. Specificity was determined using 100 sera samples collected in 2018 from healthy individuals prior to the outbreak. Analytical specificity was determined using a panel of 37 samples from individuals with respiratory illnesses other than COVID-19. RESULTS: Clinical sensitivity was 91.43% (95% CI 76.94-98.20%) for Abbott, and 88.57% (95% CI 73.26-96.80%) for both DiaSorin and EUROIMMUN. Clinical specificity was 99.00% (95% CI 94.55-99.97%) for Abbott and DiaSorin and 94.00% (95% CI 87.40-97.77%) for EUROIMMUN. The IgG assays demonstrated good qualitative agreement (minimum of 94%) and good correlation between the quantitative result for each combination of assays (r2 ≥ 0.90). The neutralizing antibody response did not necessarily follow the same temporal kinetics as the IgG response and did not necessarily correlate with IgG values. CONCLUSION: The 3 IgG antibody assays demonstrated comparable performance characteristics. Importantly, a qualitative positive IgG result obtained with any of the assays was associated with the presence of neutralizing antibodies; however, neutralizing antibody concentrations did not correlate well with signal to cutoff ratios.


Assuntos
Anticorpos Neutralizantes/imunologia , Anticorpos Antivirais/imunologia , COVID-19/imunologia , Imunoglobulina G/imunologia , SARS-CoV-2/imunologia , Adolescente , Adulto , Idoso , Anticorpos Antivirais/sangue , COVID-19/diagnóstico , Teste Sorológico para COVID-19/métodos , Criança , Pré-Escolar , Ensaio de Imunoadsorção Enzimática , Feminino , Ensaios de Triagem em Larga Escala , Humanos , Imunoglobulina G/sangue , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Adulto Jovem
12.
Fertil Steril ; 116(2): 575-582, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33812650

RESUMO

OBJECTIVE: To evaluate the diagnostic performance of the antimüllerian hormone (AMH) level determined using the Access AMH assay for predicting poor ovarian response (POR) defined as ≤4 oocytes retrieved, including the validation of the predefined AMH cutoff of 0.93 ng/mL in both serum and plasma. DESIGN: Prospective cohort study. SETTING: Fifteen private and academic fertility centers (14 in the United States and 1 in Canada). PATIENT(S): Women aged 21-45 years planning controlled ovarian stimulation for in vitro fertilization. INTERVENTION(S): None. MAIN OUTCOME MEASURE(S): Number of oocytes retrieved, categorized as POR and normal-to-high ovarian response (non-POR). The correlation of AMH level and antral follicle count. RESULT(S): Data were available for 472 participants who completed the study (74 with POR and 398 non-POR). The mean AMH serum level among those with POR was 0.99 ng/mL (median 0.76 ng/mL) compared with 2.83 ng/mL (median 2.36 ng/mL) among the normal-to-high responders. For confirmation of the 0.93 ng/mL AMH level cutoff as a predictor of POR, a receiver operating characteristic analysis gave an area under the curve of 0.852, with corresponding sensitivity and specificity of 63.5% and 89.2%, respectively. The associated positive predictive value was 52.2% and the negative predictive value was 92.9%. The AMH plasma values demonstrated a strong correlation with AMH serum values with an r value = 0.9980. The previously established AMH cutoff of 1.77 ng/mL for antral follicle count >15 resulted in a sensitivity of 83.8% (95% confidence interval [CI] 77.7-88.5) and a specificity of 59.9% (95% CI 54.2-65.4). CONCLUSION(S): This study validated the previously established AMH cut-point for the prediction of POR. Because this cut-point may vary depending on the assay used, the specific AMH assay should be reported in the literature whenever possible.


Assuntos
Hormônio Antimülleriano/sangue , Recuperação de Oócitos , Indução da Ovulação , Adulto , Feminino , Fertilização in vitro , Humanos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Adulto Jovem
13.
Microsc Microanal ; 16(2): 117-31, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20199713

RESUMO

We present an in vitro model of human skin that, together with nonlinear optical microscopy, provides a useful system for characterizing morphological and structural changes in a living skin tissue microenvironment due to changes in oxygen status and proteolytic balance. We describe for the first time the effects of chronic oxygen deprivation on a bioengineered model of human interfollicular epidermis. Histological analysis and multiphoton imaging revealed a progressively degenerating ballooning phenotype of the keratinocytes that manifested after 48 h of hypoxic exposure. Multiphoton images of the dermal compartment revealed a decrease in collagen structural order. Immunofluorescence analysis showed changes in matrix metalloproteinase (MMP)-2 protein spatial localization in the epidermis with a shift to the basal layer, and loss of Ki67 expression in proliferative basal cells after 192 h of hypoxic exposure. Upon reoxygenation MMP-2 mRNA levels showed a biphasic response, with restoration of MMP-2 levels and localization. These results indicate that chronic oxygen deprivation causes an overall degeneration in tissue architecture, combined with an imbalance in proteolytic expression and a decrease in proliferative capacity. We propose that these tissue changes are representative of the ischemic condition and that our experimental model system is appropriate for addressing mechanisms of susceptibility to chronic wounds.


Assuntos
Epiderme/patologia , Isquemia/patologia , Adulto , Humanos , Queratinócitos/patologia , Metaloproteinase 2 da Matriz/biossíntese , Microscopia de Fluorescência , Microscopia de Fluorescência por Excitação Multifotônica , Técnicas de Cultura de Órgãos , Oxigênio/metabolismo
15.
Wound Repair Regen ; 17(4): 606-16, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19614926

RESUMO

It is generally accepted that hypoxia and recovery from oxygen deprivation contribute to the breakdown and ulceration of human skin. The effects of these stresses on proliferation, differentiation and expression of cell-cell adhesion molecules were investigated for the first time in an organotypic model of human skin. Fully stratified tissues were exposed to a time course of oxygen deprivation and subsequent reoxygenation. Regional changes in keratinocyte morphology, glycogen stores and cellular junctions were observed, with more differentiated layers of the epidermis exhibiting the first evidence of oxygen deprivation. Cellular swelling within the granular layer was concurrent with aquaporin-3 depletion. The keratinocyte adherens junction proteins E-cadherin and beta-catenin were dramatically decreased in a regio-specific manner throughout the epidermis following oxygen deprivation. In contrast, P-cadherin and the desmosomal proteins desmoplakin and desmoglein-1 were refractory to oxygen deprivation. Relative to normoxic controls, hypoxic tissues exhibited increased mRNA levels of the transcriptional repressor Slug; however, mRNA levels of the related transcriptional factor Snail were unaffected. All cellular and molecular changes were reversible upon reoxygenation. These results show that oxygen deprivation and reoxygenation exert differential effects on epidermal adhesion proteins and suggest a novel role for cadherins, beta-catenin, and Slug in hypoxia-induced junctional changes occurring in stratified squamous epithelium.


Assuntos
Junções Aderentes/fisiologia , Aquaporina 3/metabolismo , Glicogênio/metabolismo , Hipóxia/fisiopatologia , Queratinócitos/fisiologia , Animais , Proliferação de Células , Humanos , Camundongos , Análise de Sequência com Séries de Oligonucleotídeos , Técnicas de Cultura de Órgãos , Cicatrização/fisiologia
16.
Lab Med ; 50(2): 145-149, 2019 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-30169773

RESUMO

BACKGROUND: Chemistry testing is requested for body fluid (BF) specimens despite the lack of assays approved by the US Food and Drug Administration (FDA). The criteria for categorizing fluids as transudate or exudate are not validated across analyzers. OBJECTIVE: To compare BF chemical analysis and classification by different analyzers. METHODS: We analyzed 10 pleural and 18 peritoneal fluids with corresponding plasma specimens using the Vitros 5,1 FS; Abbott ARCHITECT ci8200; and Roche Modular P platforms. Total protein (TP) and lactate dehydrogenase (LDH) were measured for pleural fluids. Light's criteria were applied. Albumin was measured for peritoneal specimens, and the plasma-ascites-albumin gradient was calculated. RESULTS: TP results showed agreement. The Vitros LDH assay produced higher fluid:plasma ratios. Classification by Light's criteria resulted in 1 discrepancy (ARCHITECT). Albumin results showed agreement. There were 2 discrepant gradient interpretations (Vitros). CONCLUSIONS: These data suggest that analyses of pleural and peritoneal fluids using these platforms are diagnostically interchangeable.


Assuntos
Líquido Ascítico/química , Testes de Química Clínica/métodos , Testes de Química Clínica/normas , Derrame Pleural/metabolismo , Albuminas/análise , Humanos , Valores de Referência , Reprodutibilidade dos Testes , Albumina Sérica/análise
17.
Clin Biochem ; 62: 11-23, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29800559

RESUMO

The measurement of estrogens is important for diagnosing and monitoring the health of women, men, and children. For example, for postmenopausal women or women undergoing treatment for breast cancer with aromatase inhibitors, the measurement of extremely low concentrations of estrogens in serum, especially estradiol, is problematic but essential for proper medical care. Achieving superb analytical sensitivity and specificity has been and continues to be a challenge for the clinical laboratory, but is a challenge that is being taken seriously. Focusing on publications from 2012 to 2017, this review will provide an overview of recent research in the development of methods to accurately and precisely measure estrogens, including a variety of estrogen metabolites. Additionally, the latest in clinical research involving estrogen measurement in women, men, and children will be presented to provide an update on the association of estrogens with diseases or conditions such as breast cancer, precocious puberty, infertility, and pregnancy. This research update will provide context as to why estrogen measurement is important and why laboratories are working hard to support the recommendations made by the Endocrine Society regarding estrogen measurement.


Assuntos
Glândulas Endócrinas/fisiologia , Doenças do Sistema Endócrino/sangue , Endocrinologia/métodos , Estrogênios/sangue , Medicina Baseada em Evidências , Biomarcadores/sangue , Neoplasias da Mama/sangue , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/fisiopatologia , Neoplasias da Mama/terapia , Criança , Glândulas Endócrinas/fisiopatologia , Doenças do Sistema Endócrino/diagnóstico , Doenças do Sistema Endócrino/fisiopatologia , Doenças do Sistema Endócrino/terapia , Endocrinologia/tendências , Estradiol/sangue , Estrogênios/fisiologia , Feminino , Humanos , Infertilidade Feminina/sangue , Infertilidade Feminina/diagnóstico , Infertilidade Feminina/fisiopatologia , Infertilidade Feminina/terapia , Infertilidade Masculina/sangue , Infertilidade Masculina/diagnóstico , Infertilidade Masculina/fisiopatologia , Infertilidade Masculina/terapia , Masculino , Guias de Prática Clínica como Assunto , Gravidez , Complicações na Gravidez/sangue , Complicações na Gravidez/diagnóstico , Complicações na Gravidez/fisiopatologia , Complicações na Gravidez/terapia , Prognóstico , Neoplasias da Próstata/sangue , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/fisiopatologia , Neoplasias da Próstata/terapia , Sociedades Científicas
18.
Clin Biochem ; 58: 64-71, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29763574

RESUMO

BACKGROUND: Testosterone is commonly measured using immunoassays, yet concerns with the accuracy and quality of testing by these methods exist, particularly for low testosterone concentrations. Study objectives were to evaluate selective performance characteristics, including functional sensitivity (FS), of 5 automated immunoassays for total testosterone. METHODS: FS, imprecision, assay interference, limit of blank, linearity, and accuracy were assessed using the Abbott ARCHITECT i2000SR, SIEMENS ADVIA Centaur and IMMULITE 2000, Beckman Coulter DxI 800, and Roche MODULAR E170. Comparisons to an in-house liquid chromatography-tandem mass spectrometry (LC-MS/MS) method were performed using patient samples from men, women, boys, and girls. RESULTS: FS at 20% coefficient of variation (CV) for the ARCHITECT, Centaur, DxI, E170 and IMMULITE assays were 0.14, 1.23, 0.36, 0.77, 3.49 nmol/L, respectively. Total CVs for the 5-day imprecision study were ≤ 9.0% for all methods. All assays met manufacturer's claims for hemolysis, icterus, and lipemia interference and limit of blank. Dilution linearity studies had deviations from the target recoveries ranging from 3.4% (ARCHITECT) to 14.3% (DxI). Using National Institute of Standards and Technology Standard Reference Material 971, recoveries ranged from 79.2-149.2% (DxI, male and female, respectively). When compared to LC-MS/MS, more immunoassays under-recovered in men and women and over-recovered in boys and girls. Slopes ranged from 0.71 (IMMULITE, women) to 1.35 (DxI, boys). The combined average for percent bias was higher in boys (28.0%) than men (11.6%), women (22.8%), and girls (25.7%). CONCLUSIONS: Challenges with accurately measuring testosterone appear to remain for some immunoassays, but not all. While most immunoassays remain optimized for concentrations observed in healthy men, some showed acceptable performance when challenged at lower concentrations.


Assuntos
Automação Laboratorial , Testosterona/sangue , Adolescente , Adulto , Criança , Feminino , Humanos , Imunoensaio/instrumentação , Imunoensaio/métodos , Masculino , Sensibilidade e Especificidade
19.
Thyroid ; 28(7): 842-848, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29756541

RESUMO

BACKGROUND: Clinical laboratories are under pressure to increase value by improving test utilization. The clinical utility of reverse triiodothyronine (rT3) is controversial. A study was conducted to identify order patterns that might suggest inappropriate utilization of rT3. METHODS: All orders for thyroid tests placed over a period of one year at a national reference laboratory were reviewed. Order patterns by client (hospital) and by provider were analyzed. A Pareto analysis was conducted to determine the percentage of orders placed as a function of the percentage of providers. A systematic review of the indexed literature and an informal review of the web were conducted to identify indications for rT3 testing. RESULTS: There were 402,386 orders for 447,664 thyroid tests, including 91,767 orders for rT3. These orders were placed by 60,733 providers located at 1139 different organizations. Only 20% of providers who ordered thyroid tests placed an order for rT3. Of those who placed an order for rT3, 95% placed two orders or fewer for rT3. One hundred providers (0.1% of the 60,733 providers who placed orders for thyroid tests) accounted for 29.5% of the orders for rT3. Of the 100 providers, 60 with the highest order volumes for rT3 were classified as practitioners of functional medicine. A systematic review of Medline found little evidence to support the high volumes of orders for rT3. A survey of Web sites for functional medicine suggests that rT3 is useful for the diagnosis of rT3 dominance and can be used to direct triiodothyronine replacement therapy. CONCLUSIONS: There is wide practice variation in rT3 testing. A high proportion of tests are ordered by a relatively small proportion of providers. There is little evidence to support high volumes of rT3 testing placed by some practitioners.


Assuntos
Testes de Função Tireóidea , Tri-Iodotironina Reversa/sangue , Tri-Iodotironina/sangue , Humanos
20.
Fertil Steril ; 110(3): 506-513.e3, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29960708

RESUMO

OBJECTIVE: To evaluate a new fully automated antimüllerian hormone (AMH) assay for prediction of poor ovarian response (POR) to ovarian stimulation defined as four or fewer oocytes retrieved. DESIGN: Prospective cohort study. SETTING: Thirteen private and academic fertility centers in the United States. PATIENTS(S): A total of 178 women undergoing their first in vitro fertilization (IVF) cycle eligible for the study were consented and enrolled, with data available from 160 women for prediction of POR and 164 women for AMH correlation with antral follicle count (AFC). INTERVENTION(S): None. MAIN OUTCOME MEASURE(S): Cutoff point for AMH that predicts POR. Correlation of AMH with AFC, and cutoff point for AMH that correlates with antral follicle count >15. RESULT(S): The mean AMH among the poor responders was 0.74 ng/mL, compared with 3.20 ng/mL for normal to high responders. The AMH cutoff at 90% specificity for predicting POR with the use of the receiver operating characteristic (ROC) curve was 0.93 ng/mL, with an associated sensitivity of 74.1%. For prediction of POR, ROC analysis showed that AMH (area under the ROC curve [AUC] = 0.929) was significantly better than FSH (AUC = 0.615; P<.0001). AMH was positively correlated with AFC (Spearman rho = 0.756). The AMH at 90% sensitivity for AFC >15 was 1.75, with specificity of 59.1%. CONCLUSION(S): A fully automated AMH assay can be a useful biomarker for predicting POR in IVF cycles. Because AMH cutoff points vary depending on the assay used, future studies should continue to calibrate test results to clinically important outcomes.


Assuntos
Hormônio Antimülleriano/sangue , Recuperação de Oócitos/métodos , Folículo Ovariano/fisiologia , Indução da Ovulação/métodos , Adulto , Biomarcadores/sangue , Estudos Transversais , Feminino , Humanos , Pessoa de Meia-Idade , Recuperação de Oócitos/tendências , Folículo Ovariano/citologia , Indução da Ovulação/tendências , Valor Preditivo dos Testes , Estudos Prospectivos , Adulto Jovem