Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Sensors (Basel) ; 23(15)2023 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-37571442

RESUMO

This paper presents a novel method based on a convolutional neural network to recover thermal time constants from a temperature-time curve after thermal excitation. The thermal time constants are then used to detect the pathological states of the skin. The thermal system is modeled as a Foster Network consisting of R-C thermal elements. Each component is represented by a time constant and an amplitude that can be retrieved using the deep learning system. The presented method was verified on artificially generated training data and then tested on real, measured thermographic signals from a patient suffering from psoriasis. The results show proper estimation both in time constants and in temperature evaluation over time. The error of the recovered time constants is below 1% for noiseless input data, and it does not exceed 5% for noisy signals.


Assuntos
Redes Neurais de Computação , Pele , Humanos , Termografia/métodos , Temperatura
2.
Sensors (Basel) ; 21(22)2021 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-34833558

RESUMO

The aim of this study was to evaluate whether textural analysis could differentiate between the two common types of lytic lesions imaged with use of radiography. Sixty-two patients were enrolled in the study with intraoral radiograph images and a histological reference study. Full textural analysis was performed using MaZda software. For over 10,000 features, logistic regression models were applied. Fragments containing lesion edges were characterized by significant correlation of structural information. Although the input images were stored using lossy compression and their scale was not preserved, the obtained results confirmed the possibility of distinguishing between cysts and granulomas with use of textural analysis of intraoral radiographs. It was shown that the important information distinguishing the aforementioned types of lesions is located at the edges and not within the lesion.


Assuntos
Cistos , Diagnóstico Diferencial , Granuloma , Humanos , Radiografia
3.
Sensors (Basel) ; 21(19)2021 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-34640959

RESUMO

Melanoma is one of the most lethal and rapidly growing cancers, causing many deaths each year. This cancer can be treated effectively if it is detected quickly. For this reason, many algorithms and systems have been developed to support automatic or semiautomatic detection of neoplastic skin lesions based on the analysis of optical images of individual moles. Recently, full-body systems have gained attention because they enable the analysis of the patient's entire body based on a set of photos. This paper presents a prototype of such a system, focusing mainly on assessing the effectiveness of algorithms developed for the detection and segmentation of lesions. Three detection algorithms (and their fusion) were analyzed, one implementing deep learning methods and two classic approaches, using local brightness distribution and a correlation method. For fusion of algorithms, detection sensitivity = 0.95 and precision = 0.94 were obtained. Moreover, the values of the selected geometric parameters of segmented lesions were calculated and compared for all algorithms. The obtained results showed a high accuracy of the evaluated parameters (error of area estimation <10%), especially for lesions with dimensions greater than 3 mm, which are the most suspected of being neoplastic lesions.


Assuntos
Melanoma , Dermatopatias , Neoplasias Cutâneas , Algoritmos , Imagem Corporal , Humanos , Melanoma/diagnóstico por imagem , Neoplasias Cutâneas/diagnóstico por imagem
4.
Biomed Eng Online ; 18(1): 56, 2019 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-31088563

RESUMO

BACKGROUND: In clinical diagnostics, combination of different imaging techniques is applied to assess spatial configuration of the abdominal aortic aneurysm (AAA) and deformation of its wall. As deformation of aneurysm wall is crucial parameter in assessing wall rupture, we aimed to develop and validate a Non-Invasive Vision-Based System (NIVBS) for the analysis of 3D elastic artificial abdominal aortic models. 3D-printed elastic AAA models from four patients were applied for the reconstruction of real hemodynamic. During experiments, the inlet boundary conditions included the injection volume and frequency of pulsation averaged from electrocardiography traces. NIVBS system was equipped with nine cameras placed at a constant distance to record wall movement from 360o angle and a dedicated set of artificial lights providing coherent illumination. Additionally, self-prepared algorithms for image acquisition, processing, segmentation, and contour detection were used to analyze wall deformation. Finally, the shape deformation factor was applied to evaluate aorta's deformation. Experimental results were confronted with medical data from AngioCT and 2D speckle-tracking echocardiography (2DSTE). RESULTS: Image square analyses indicated that the optimal distance between the camera's lens and the investigated object was in the range of 0.30-0.35 m. There was approximately 1.44% difference observed in aneurysm diameters between NIVBS (86.57 ± 5.86 mm) and AngioCT (87.82 ± 6.04 mm) (p = 0.7764). The accuracy of developed algorithm for the reconstruction of the AAA deformation was equal to 98.56%. Bland-Altman analysis showed that the difference between clinical data (2DSTE) and predicted wall deformation (NIVBS) for all patients was 0.00 mm (confidence interval equal to 0.12 mm) for aneurysm size, 0.01 mm (confidence interval equal to 0.13 mm) and 0.00 mm (confidence interval equal to 0.09 mm) for the anterior and posterior side, as well as 0.01 mm (confidence interval equal to 0.18 mm) and 0.01 mm (confidence interval equal to 0.11 mm) for the left and right side. The optimal range of camera's lens did not affect acquired values. CONCLUSIONS: The NIVBS with proposed algorithm that reconstructs the pressure from surrounding organs is appropriate to analyze the AAAs in water environment. Moreover, NIVBS allowed detailed quantitative analysis of aneurysm sac wall deformation.


Assuntos
Aneurisma da Aorta Abdominal/patologia , Modelos Anatômicos , Algoritmos , Angiografia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Elasticidade , Humanos , Imageamento Tridimensional , Impressão Tridimensional , Tomografia Computadorizada por Raios X
5.
Biomed Eng Online ; 17(1): 41, 2018 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-29661193

RESUMO

BACKGROUND: With the development of versatile magnetic resonance acquisition techniques there arises a need for more advanced imaging simulation tools to enable adequate image appearance prediction, measurement sequence design and testing thereof. Recently, there is a growing interest in phase contrast angiography (PCA) sequence due to the capabilities of blood flow quantification that it offers. Moreover, as it is a non-contrast enhanced protocol, it has become an attractive option in areas, where usage of invasive contrast agents is not indifferent for the imaged tissue. Monitoring of the kidney function is an example of such an application. RESULTS: We present a computer framework for simulation of the PCA protocol, both conventional and accelerated with echo-planar imaging (EPI) readout, and its application to the numerical models of kidney vasculatures. Eight patient-specific renal arterial trees were reconstructed following vessel segmentation in real computed tomography angiograms. In addition, a synthetic model was designed using a vascular tree growth simulation algorithm. The results embrace a series of synthetic PCA images of the renal arterial trees giving insight into the image formation and quantification of kidney hemodynamics. CONCLUSIONS: The designed simulation framework enables quantification of the PCA measurement error in relation to ground-truth flow velocity data. The mean velocity measurement error for the reconstructed renal arterial trees range from 1.5 to 12.8% of the aliasing velocity value, depending on image resolution and flip angle. No statistically significant difference was observed between measurements obtained using EPI with a number of echos (NETL) = 4 and conventional PCA. In case of higher NETL factors peak velocity values can be underestimated up to 34%.


Assuntos
Angiografia , Artérias/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Rim/irrigação sanguínea , Modelos Biológicos , Humanos , Análise de Componente Principal
6.
Medicina (Kaunas) ; 54(3)2018 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-30344273

RESUMO

Background and objectives: Brain ischemic stroke is caused by impaired or absolutely blocked blood flow into the brain regions. Despite the large number of possible origins, there is no general strategy for preventive treatment. In this paper, we aimed to predict the hemodynamics in a patient who experienced a critical stenosis operation in the carotid artery. This is a unique study where we used medical data together with the computational fluid (CFD) technique not to plan the surgery, but to predict its outcome. Materials and Methods: AngioCT data and blood perfusion of brain tissue (CT-perfusion) together with CFD technique were applied for stroke formation reconstruction in different clinical conditions. With the use of self-made semiautomatic algorithm for image processing and 3DDoctror software, 3D-vascular geometries before and after surgical intervention were reconstructed. As the paper is focused on the analysis of stroke appearance, apparent stroke was simulated as higher and lower pressure values in the cranial part due to different outcomes of the surgical intervention. This allowed to investigate the influence of spatial configuration and pressure values on blood perfusion in the analyzed circulatory system. Results: Application of CFD simulations for blood flow reconstruction for clinical conditions in the circulatory system accomplished on average 98.5% and 98.7% accuracy for CFD results compared to US-Doppler before and after surgical intervention, respectively. Meanwhile, CFD results compared to CT-perfusion indicated an average 89.7% and 92.8% accuracy before and after surgical intervention, respectively. Thus, the CFD is a reliable approach for predicting the patient hemodynamics, as it was confirmed by postoperative data. Conclusions: Our study indicated that the application of CFD simulations for blood flow reconstruction for clinical conditions in circulatory system reached 98% and 90% accuracy for US-Doppler and CT-perfusion, respectively. Therefore, the proposed method might be used as a tool for reconstruction of specific patients' hemodynamics after operation of critical stenosis in the carotid artery. However, further studies are necessary to confirm its usefulness in clinical practice.


Assuntos
Angioplastia com Balão/métodos , Estenose das Carótidas/cirurgia , Hidrodinâmica , Avaliação de Resultados em Cuidados de Saúde/métodos , Modelagem Computacional Específica para o Paciente/estatística & dados numéricos , Idoso , Velocidade do Fluxo Sanguíneo , Artérias Carótidas/fisiopatologia , Estenose das Carótidas/complicações , Estenose das Carótidas/fisiopatologia , Feminino , Hemodinâmica , Humanos , Ataque Isquêmico Transitório/etiologia , Ataque Isquêmico Transitório/fisiopatologia , Ataque Isquêmico Transitório/cirurgia , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Resultado do Tratamento , Ultrassonografia Doppler/estatística & dados numéricos
7.
Cancers (Basel) ; 16(10)2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38791949

RESUMO

Artificial intelligence (AI) is currently becoming a leading field in data processing [...].

8.
Math Ann ; 388(4): 3463-3527, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39131115

RESUMO

For m , n ∈ N , let X = ( X ij ) i ≤ m , j ≤ n be a random matrix, A = ( a ij ) i ≤ m , j ≤ n a real deterministic matrix, and X A = ( a ij X ij ) i ≤ m , j ≤ n the corresponding structured random matrix. We study the expected operator norm of X A considered as a random operator between ℓ p n and ℓ q m for 1 ≤ p , q ≤ ∞ . We prove optimal bounds up to logarithmic terms when the underlying random matrix X has i.i.d. Gaussian entries, independent mean-zero bounded entries, or independent mean-zero ψ r ( r ∈ ( 0 , 2 ] ) entries. In certain cases, we determine the precise order of the expected norm up to constants. Our results are expressed through a sum of operator norms of Hadamard products A ∘ A and ( A ∘ A ) T .

9.
Clin Dermatol ; 42(3): 280-295, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38181888

RESUMO

The incidence of melanoma is increasing rapidly. This cancer has a good prognosis if detected early. For this reason, various systems of skin lesion image analysis, which support imaging diagnostics of this neoplasm, are developing very dynamically. To detect and recognize neoplastic lesions, such systems use various artificial intelligence (AI) algorithms. This area of computer science applications has recently undergone dynamic development, abounding in several solutions that are effective tools supporting diagnosticians in many medical specialties. In this contribution, a number of applications of different classes of AI algorithms for the detection of this skin melanoma are presented and evaluated. Both classic systems based on the analysis of dermatoscopic images as well as total body systems, enabling the analysis of the patient's whole body to detect moles and pathologic changes, are discussed. These increasingly popular applications that allow the analysis of lesion images using smartphones are also described. The quantitative evaluation of the discussed systems with particular emphasis on the method of validation of the implemented algorithms is presented. The advantages and limitations of AI in the analysis of lesion images are also discussed, and problems requiring a solution for more effective use of AI in dermatology are identified.


Assuntos
Algoritmos , Inteligência Artificial , Dermoscopia , Melanoma , Neoplasias Cutâneas , Humanos , Neoplasias Cutâneas/diagnóstico , Neoplasias Cutâneas/diagnóstico por imagem , Neoplasias Cutâneas/patologia , Melanoma/diagnóstico , Melanoma/diagnóstico por imagem , Smartphone
10.
Cardiol J ; 31(5): 699-707, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38742717

RESUMO

BACKGROUND: Evaluation of standard echocardiographic examination with artificial intelligence may help in the diagnosis of myocardial viability and function recovery after acute coronary syndrome. METHODS: Sixty-one consecutive patients with acute coronary syndrome were enrolled in the present study (43 men, mean age 61 ± 9 years). All patients underwent percutaneous coronary intervention (PCI). 533 segments of the heart echo images were used. After 12 ± 1 months of follow-up, patients had an echocardiographic evaluation. After PCI each patient underwent cardiac magnetic resonance (CMR) with late enhancement and low-dose dobutamine echocardiographic examination. For texture analysis, custom software was used (MaZda 5.20, Institute of Electronics).Linear and non-linear (neural network) discriminative analyses were performed to identify the optimal analytic method correlating with CMR regarding the necrosis extent and viability prediction after follow-up. Texture parameters were analyzed using machine learning techniques: Artificial Neural Networks, Namely Multilayer Perceptron, Nonlinear Discriminant Analysis, Support Vector Machine, and Adaboost algorithm. RESULTS: The mean concordance between the CMR definition of viability and three classification models in Artificial Neural Networks varied from 42% to 76%. Echo-based detection of non-viable tissue was more sensitive in the segments with the highest relative transmural scar thickness: 51-75% and 76-99%. The best results have been obtained for images with contrast for red and grey components (74% of proper classification). In dobutamine echocardiography, the results of appropriate prediction were 67% for monochromatic images. CONCLUSIONS: Detection and semi-quantification of scar transmurality are feasible in echocardiographic images analyzed with artificial intelligence. Selected analytic methods yielded similar accuracy, and contrast enhancement contributed to the prediction accuracy of myocardial viability after myocardial infarction in 12 months of follow-up.


Assuntos
Inteligência Artificial , Infarto do Miocárdio , Miocárdio , Valor Preditivo dos Testes , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Miocárdio/patologia , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/diagnóstico por imagem , Intervenção Coronária Percutânea , Idoso , Sobrevivência de Tecidos , Imagem Cinética por Ressonância Magnética/métodos , Ecocardiografia sob Estresse/métodos , Redes Neurais de Computação , Seguimentos , Síndrome Coronariana Aguda/fisiopatologia , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/diagnóstico , Fatores de Tempo , Reprodutibilidade dos Testes
11.
J Clin Med ; 13(7)2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38610669

RESUMO

Objectives: The purpose of this paper is to assess the determination of male and female sex from trabecular bone structures in the pelvic region. The study involved analyzing digital radiographs for 343 patients and identifying fourteen areas of interest based on their medical significance, with seven regions on each side of the body for symmetry. Methods: Textural parameters for each region were obtained using various methods, and a thorough investigation of data normalization was conducted. Feature selection approaches were then evaluated to determine a small set of the most representative features, which were input into several classification machine learning models. Results: The findings revealed a sex-dependent correlation in the bone structure observed in X-ray images, with the degree of dependency varying based on the anatomical location. Notably, the femoral neck and ischium regions exhibited distinctive characteristics between sexes. Conclusions: This insight is crucial for medical professionals seeking to estimate sex dependencies from such image data. For these four specific areas, the balanced accuracy exceeded 70%. The results demonstrated symmetry, confirming the genuine dependencies in the trabecular bone structures.

12.
Pol J Radiol ; 78(1): 50-6, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23493465

RESUMO

BACKGROUND: Susceptibility weighted imaging (SWI) is a novel MRI sequence which demonstrates the susceptibility differences between adjacent tissues and it is promising to be a sequence useful in the assessment of brain tumors vascularity. The aim of our study was to demonstrate usefulness of SWI in evaluation of intratumoral vessels in comparison to CET1 sequence in a standardized, objective manner. MATERIAL/METHODS: 10 patients with supratentorial brain tumors were included in the study. All of them underwent conventional MRI examination with a 1,5 T scanner. SWI sequence was additionally performed using the following parameters: TR 49 ms,TE 40 ms. We used authors' personal computer software - Vessels View, to assess the vessels number. RESULTS: Comparison of SWI and CET1 sequences was performed using our program. Analysis of all 26 ROIs demonstrated predominance of SWI in the amount of white pixels (vessel cross-sectional) and a similar number of elongated structures (blood vessels). CONCLUSIONS: To conclude, the results of this study are encouraging; they confirm the added value of SWI as an appropriate and useful sequence in the process of evaluation of intratumoral vascularity. Using our program significantly improved visualization of blood vessels in cerebral tumors. The Vessel View application assists radiologists in demonstrating the vessels and facilitates distinguishing them from adjacent tissues in the image.

13.
J Clin Med ; 12(20)2023 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-37892722

RESUMO

Modern medical imaging systems provide ever-more information about the patient's health condition [...].

14.
J Clin Med ; 12(8)2023 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-37109098

RESUMO

Currently, bone age is assessed by X-rays. It enables the evaluation of the child's development and is an important diagnostic factor. However, it is not sufficient to diagnose a specific disease because the diagnoses and prognoses may arise depending on how much the given case differs from the norms of bone age. BACKGROUND: The use of magnetic resonance images (MRI) to assess the age of the patient would extend diagnostic possibilities. The bone age test could then become a routine screening test. Changing the method of determining the bone age would also prevent the patient from taking a dose of ionizing radiation, making the test less invasive. METHODS: The regions of interest containing the wrist area and the epiphyses of the radius are marked on the magnetic resonance imaging of the non-dominant hand of boys aged 9 to 17 years. Textural features are computed for these regions, as it is assumed that the texture of the wrist image contains information about bone age. RESULTS: The regression analysis revealed that there is a high correlation between the bone age of a patient and the MRI-derived textural features derived from MRI. For DICOM T1-weighted data, the best scores reached 0.94 R2, 0.46 RMSE, 0.21 MSE, and 0.33 MAE. CONCLUSIONS: The experiments performed have shown that using the MRI images gives reliable results in the assessment of bone age while not exposing the patient to ionizing radiation.

15.
J Clin Med ; 11(9)2022 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-35566657

RESUMO

The selection of the matrix size is an important element of the magnetic resonance imaging (MRI) process, and has a significant impact on the acquired image quality. Signal to noise ratio, often used to assess MR image quality, has its limitations. Thus, for this purpose we propose a novel approach: the use of texture analysis as an index of the image quality that is sensitive for the change of matrix size. Image texture in biomedical images represents tissue and organ structures visualized via medical imaging modalities such as MRI. The correlation between texture parameters determined for the same tissues visualized in images acquired with different matrix sizes is analyzed to aid in the assessment of the selection of the optimal matrix size. T2-weighted coronal images of shoulders were acquired using five different matrix sizes while maintaining the same field of view; three regions of interest (bone, fat, and muscle) were considered. Lin's correlation coefficients were calculated for all possible pairs of the 310-element texture feature vectors evaluated for each matrix. The obtained results are discussed considering the image noise and blurring effect visible in images acquired with smaller matrices. Taking these phenomena into account, recommendations for the selection of the matrix size used for the MRI imaging were proposed.

16.
Sensors (Basel) ; 11(4): 3401-17, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22163803

RESUMO

We present an application-specific integrated circuit (ASIC) CMOS chip that implements a synchronized oscillator cellular neural network with a matrix size of 32 × 32 for object sensing and labeling in binary images. Networks of synchronized oscillators are a recently developed tool for image segmentation and analysis. Its parallel network operation is based on a "temporary correlation" theory that attempts to describe scene recognition as if performed by the human brain. The synchronized oscillations of neuron groups attract a person's attention if he or she is focused on a coherent stimulus (image object). For more than one perceived stimulus, these synchronized patterns switch in time between different neuron groups, thus forming temporal maps that code several features of the analyzed scene. In this paper, a new oscillator circuit based on a mathematical model is proposed, and the network architecture and chip functional blocks are presented and discussed. The proposed chip is implemented in AMIS 0.35 µm C035M-D 5M/1P technology. An application of the proposed network chip for the segmentation of insulin-producing pancreatic islets in magnetic resonance liver images is presented.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Modelos Neurológicos , Modelos Teóricos , Redes Neurais de Computação , Humanos , Ilhotas Pancreáticas/diagnóstico por imagem , Fígado/diagnóstico por imagem , Radiografia
17.
Diagnostics (Basel) ; 11(10)2021 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-34679564

RESUMO

Using computer tomography angiography (CTA) and computational structural analysis, we present a non-invasive method of mass flow rate/velocity and wall stress analysis in type B aortic dissection. Three-dimensional (3D) computer models of the aorta were calculated using pre-operative (baseline) and post-operative CT data from 12 male patients (aged from 51 to 64 years) who were treated for acute type B dissection. A computational fluid dynamics (CFD) technique was used to quantify the displacement forces acting on the aortic wall in the areas of endografts placement. The mass flow rate and wall stress were measured and quantified using the CFD technique. The CFD model indicated the places with a lower value of blood velocity and shear rate, which corelated with higher blood viscosity and a probability of thrombus appearance. Moreover, with the increase in Hct, blood viscosity also increased, while the intensity of blood flow provoked changing viscosity values in these areas. Furthermore, the velocity gradient near the tear surface caused high wall WSS; this could lead to a decreased resistance in the aorta's wall with further implications to a patient.

18.
Comput Med Imaging Graph ; 81: 101716, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32222685

RESUMO

Image texture is a very important component in many types of images, including medical images. Medical images are often corrupted by noise and affected by artifacts. Some of the texture-based features that should describe the structure of the tissue under examination may also reflect, for example, the uneven sensitivity of the scanner within the tissue region. This in turn may lead to an inappropriate description of the tissue or incorrect classification. To limit these phenomena, the analyzed regions of interest are normalized. In texture analysis methods, image intensity normalization is usually followed by a reduction in the number of levels coding the intensity. The aim of this work was to analyze the impact of different image normalization methods and the number of intensity levels on texture classification, taking into account noise and artifacts related to uneven background brightness distribution. Analyses were performed on four sets of images: modified Brodatz textures, kidney images obtained by means of dynamic contrast-enhanced magnetic resonance imaging, shoulder images acquired as T2-weighted magnetic resonance images and CT heart and thorax images. The results will be of use for choosing a particular method of image normalization, based on the types of noise and distortion present in the images.


Assuntos
Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Artefatos , Humanos
19.
Diagnostics (Basel) ; 10(10)2020 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-32977588

RESUMO

The aim of this study was to prepare a self-made mathematical algorithm for the estimation of risk of stent-graft migration with the use of data on abdominal aortic aneurysm (AAA) size and geometry of blood flow through aneurysm sac before or after stent-graft implantation. AngioCT data from 20 patients aged 50-60 years, before and after stent-graft placement in the AAA was analyzed. In order to estimate the risk of stent-graft migration for each patient we prepared an opposite spatial configuration of virtually reconstructed stent-graft with long body or short body. Thus, three groups of 3D geometries were analyzed: 20 geometries representing 3D models of aneurysm, 20 geometries representing 3D models of long body stent-grafts, and 20 geometries representing 3D models of short body stent-graft. The proposed self-made algorithm demonstrated its efficiency and usefulness in estimating wall shear stress (WSS) values. Comparison of the long or short type of stent-graft with AAA geometries allowed to analyze the implants' spatial configuration. Our study indicated that short stent-graft, after placement in the AAA sac, generated lower drug forces compare to the long stent-graft. Each time shape factor was higher for short stent-graft compare to long stent-graft.

20.
J Clin Med ; 9(5)2020 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-32370301

RESUMO

The aim of this study was to create a mathematical approach for blood hemodynamic description with the use of brightness analysis. Medical data was collected from three male patients aged from 45 to 65 years with acute type IIIb aortic dissection that started proximal to the left subclavian artery and involved the renal arteries. For the recognition of wall dissection areas Digital Imaging and Communications in Medicine (DICOM) data were applied. The distance from descending aorta to the diaphragm was analyzed. Each time Feret (DF) and Hydraulic (DHy) diameter were calculated. Moreover, an average brightness (BAV) was analyzed. Finally, to describe blood hemodynamic in the area of aortic wall dissection, mathematical function combining difference in brightness value and diameter for each computed tomography (CT) scan was calculated. The results indicated that DF described common duct more accurately compare to DHy. While, DHy described more accurately true and false ducts. Each time when connection of true and false duct appeared, true duct had lower brightness compare to common duct and false duct. Moreover, false duct characterized with higher brightness compare to common duct. In summary, the proposed algorithm mimics changes in brightness value for patients with acute type IIIb aortic dissection.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA