1.
Pract Radiat Oncol ; 14(3): e173-e179, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38176466

RESUMO

PURPOSE: With expansion of academic cancer center networks across geographically-dispersed sites, ensuring high-quality delivery of care across all network affiliates is essential. We report on the characteristics and efficacy of a radiation oncology peer-review quality assurance (QA) system implemented across a large-scale multinational cancer network. METHODS AND MATERIALS: Since 2014, weekly case-based peer-review QA meetings have been standard for network radiation oncologists with radiation oncology faculty at a major academic center. This radiotherapy (RT) QA program involves pre-treatment peer-review of cases by disease site, with disease-site subspecialized main campus faculty members. This virtual QA platform involves direct review of the proposed RT plan as well as supporting data, including relevant pathology and imaging studies for each patient. Network RT plans were scored as being concordant or nonconcordant based on national guidelines, institutional recommendations, and/or expert judgment when considering individual patient-specific factors for a given case. Data from January 1, 2014, through December 31, 2019, were aggregated for analysis. RESULTS: Between 2014 and 2019, across 8 network centers, a total of 16,601 RT plans underwent peer-review. The network-based peer-review case volume increased over the study period, from 958 cases in 2014 to 4,487 in 2019. A combined global nonconcordance rate of 4.5% was noted, with the highest nonconcordance rates among head-and-neck cases (11.0%). For centers that joined the network during the study period, we observed a significant decrease in the nonconcordance rate over time (3.1% average annual decrease in nonconcordance, P = 0.01); among centers that joined the network prior to the study period, nonconcordance rates remained stable over time. CONCLUSIONS: Through a standardized QA platform, network-based multinational peer-review of RT plans can be achieved. Improved concordance rates among newly added network affiliates over time are noted, suggesting a positive impact of network membership on the quality of delivered cancer care.


Assuntos
Garantia da Qualidade dos Cuidados de Saúde , Radioterapia (Especialidade) , Humanos , Radioterapia (Especialidade)/normas , Garantia da Qualidade dos Cuidados de Saúde/normas , Revisão por Pares/métodos , Neoplasias/radioterapia
2.
J Oncol Pract ; 12(4): e476-86, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26931402

RESUMO

PURPOSE: Academic centers increasingly find a need to define a comprehensive peer-review program that can translate high-quality radiation therapy (RT) to community network sites. In this study, we describe the initial results of a quarterly quality audit program that aims to improve RT peer-review and provider educational processes across community sites. MATERIALS AND METHODS: An electronic tool was used by community-based certified member (CM) sites to enter clinical treatment information about patients undergoing peer review. At least 10% of the patient load for each CM physician was selected for audit on a quarterly basis by expert academic faculty. Quality metrics included the review of the management plan, technical plan, and other indicators. RT was scored as being concordant or nonconcordant with institutional guidelines, national standards, or expert judgment. RESULTS: A total of 719 patients were entered into the peer-review database by the first four CM sites. Of 14% of patients audited, 17% (18 of 104) were deemed nonconcordant. Nonconcordance rates were lowest in prevalent disease sites, such as breast (16%), colorectal (14%), and lung (12%), whereas rates were highest in lymphoma (50%), brain (44%), and gynecology (27%). Deficiencies included incomplete staging work-up, incorrect target and normal tissue delineation, and nonadherence to accepted dose-volume constraints. CONCLUSION: Given the high rate of nonconcordance, we recommend prospective, pre-RT peer review of all patients, and, in particular, expert review of patients that are from low-volume or complex disease sites. An integrated approach to peer review holds a promise of improving the quality, safety, and value of cancer therapy in the community setting.


Assuntos
Centros Médicos Acadêmicos/normas , Institutos de Câncer/normas , Revisão dos Cuidados de Saúde por Pares , Qualidade da Assistência à Saúde , Radioterapia (Especialidade)/normas , Humanos , Auditoria Médica/métodos , Revisão dos Cuidados de Saúde por Pares/métodos