Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
J Vasc Interv Radiol ; 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38670527

RESUMO

PURPOSE: To evaluate the safety and effectiveness of track cauterization for lung cryoablation through comparison of postprocedural adverse event (AE) rates. MATERIALS AND METHODS: Fifty-nine patients who underwent 164 percutaneous lung cryoablation procedures between 2013 and 2018 were included in this retrospective study. The study cohort was subdivided by whether track cauterization was conducted or not at the end of the procedure. The study cohort was also subdivided by the number of probes (1-2 probes vs 3-4 probes). Postablation AE rates were assessed by immediate and delayed (at 1 month or later) AEs, pneumothorax, hemothorax, pleural effusion, and whether intervention was required. Univariate and multivariate logistic regression analyses were used to compare differences in AE rates. RESULTS: Patients who underwent procedures with track cautery were 2.6 times less likely to exhibit pleural effusion (P = .017). Patients who underwent procedures conducted with a higher number of probes were 3.8 times more likely to receive interventions (P < .001), 1.6 times more likely to experience pneumothorax (P = .037), and 2.1 times more likely to experience pleural effusion (P = .003). History of lung surgery, increased number of probes, size of the probe, and absence of track cautery were noted to be significant predictors of AEs and need for interventions (all P < .05). CONCLUSIONS: Track cauterization in lung cryoablation was proven to reduce pleural effusion, but no difference in pneumothorax or delayed AEs was noted. The use of fewer probes was associated with a lower rate of AEs.

2.
AJR Am J Roentgenol ; 222(2): e2330300, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37966037

RESUMO

BACKGROUND. Treatment options for patients with interstitial lung disease (ILD) who develop stage I-II non-small cell lung cancer (NSCLC) are severely limited, given that surgical resection, radiation, and systemic therapy are associated with significant morbidity and mortality. OBJECTIVE. The aim of this study was to evaluate the safety and efficacy of percutaneous ablation of stage I-II NSCLC in patients with ILD. METHODS. This retrospective study included patients with ILD and stage I-II NSCLC treated with percutaneous ablation in three health systems between October 2004 and February 2023. At each site, a single thoracic radiologist, blinded to clinical outcomes, reviewed preprocedural chest CT examinations for the presence and type of ILD according to 2018 criteria proposed by the American Thoracic Society, European Respiratory Society, Japanese Respiratory Society, and Latin American Thoracic Society. The primary outcome was 90-day major (grade ≥ 3) adverse events, based on Common Terminology Criteria for Adverse Events (CTCAE) version 5.0. Secondary outcomes were hospital length of stay (HLOS), local tumor control, and overall survival (OS). RESULTS. The study included 33 patients (19 men, 14 women; median age, 78 years; 16 patients with Eastern Cooperative Oncology Group performance status ≤ 1) with ILD who underwent 42 percutaneous ablation sessions (21 cryoablations, 11 radiofrequency ablations, 10 microwave ablations) of 43 NSCLC tumors ((median tumor size, 1.6 cm; IQR, 1.4-2.5 cm; range, 0.7-5.4 cm; 37 stage I, six stage II). The extent of lung fibrosis was 20% or less in 24 patients; 17 patients had imaging findings of definite or probable usual interstitial pneumonia. The 90-day major adverse event rate was 14% (6/42), including one CTCAE grade 4 event. No acute ILD exacerbation or death occurred within 90 days after ablation. The median HLOS was 1 day (IQR, 0-2 days). Median imaging follow-up for local tumor control was 17 months (IQR, 11-32 months). Median imaging or clinical follow-up for OS was 16 months (IQR, 6-26 months). Local tumor control and OS were 78% and 77%, respectively, at 1 year and 73% and 46% at 2 years. CONCLUSION. Percutaneous ablation appears to be a safe and effective treatment option for stage I-II NSCLC in the setting of ILD after multidisciplinary selection. CLINICAL IMPACT. Patients with ILD and stage I-II NSCLC should be considered for percutaneous ablation given that they are frequently ineligible for surgical resection, radiation, and systemic therapy.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Doenças Pulmonares Intersticiais , Neoplasias Pulmonares , Masculino , Humanos , Feminino , Idoso , Carcinoma Pulmonar de Células não Pequenas/complicações , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Neoplasias Pulmonares/complicações , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/cirurgia , Estudos Retrospectivos , Doenças Pulmonares Intersticiais/complicações , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Doenças Pulmonares Intersticiais/cirurgia , Resultado do Tratamento
3.
J Vasc Interv Radiol ; 33(8): 964-971.e2, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35490932

RESUMO

PURPOSE: To assess the cost effectiveness of microwave ablation (MWA) and stereotactic body radiotherapy (SBRT) for patients with inoperable stage I non-small cell lung cancer (NSCLC). MATERIALS AND METHODS: A literature search was performed in MEDLINE with broad search clusters. A decision-analytic model was constructed over a 5-year period. The model incorporated treatment-related complications and long-term recurrence. All clinical parameters were derived from the literature with preference to long-term prospective trials. A healthcare payers' perspective was adopted. Outcomes were measured in quality-adjusted life years (QALYs) extracted from prior studies and U.S. dollars from Medicare reimbursements and prior studies. Base case calculations, probabilistic sensitivity analysis with 10,000 Monte Carlo simulations, and multiple 1- and 2-way sensitivity analyses were performed. RESULTS: MWA yielded a health benefit of 2.31 QALYs at a cost of $195,331, whereas SBRT yielded a health benefit of 2.33 QALYs at a cost of $225,271. The incremental cost-effectiveness ratio was $1,480,597/QALY, indicating that MWA is the more cost-effective strategy. The conclusion remains unchanged in probabilistic sensitivity analysis with MWA being the optimal cost strategy in 99.84% simulations. One-way sensitivity analyses revealed that MWA remains cost effective when its annual recurrence risk is <18.4% averaged over 5 years, when the SBRT annual recurrence risk is >1.44% averaged over 5 years, or when MWA is at least $7,500 cheaper than SBRT. CONCLUSIONS: MWA appears to be more cost effective than SBRT for patients with inoperable stage I NSCLC.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Radiocirurgia , Idoso , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Análise Custo-Benefício , Humanos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirurgia , Cadeias de Markov , Medicare , Micro-Ondas/efeitos adversos , Estudos Prospectivos , Anos de Vida Ajustados por Qualidade de Vida , Radiocirurgia/efeitos adversos , Estados Unidos
4.
J Vasc Interv Radiol ; 32(5): 729-738, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33608192

RESUMO

PURPOSE: To assess the safety, feasibility, and efficacy of percutaneous thermal ablation (TA) in the treatment of metastatic gynecologic (GYN) tumors. MATERIALS AND METHODS: A study cohort of 42 consecutive women (mean age, 59. years; range, 25-78 years) with metastatic GYN tumors (119 metastatic tumors) treated with radiofrequency (n = 47 tumors), microwave (n = 47 tumors), or cryogenic (n = 30 tumors) ablation from over 2,800 ablations performed from January 2001 to January 2019 was identified. The primary GYN neoplasms consisted of ovarian (27 patients; 77 tumors; mean tumor diameter [MTD], 2.50 cm), uterine (7 patients; 26 tumors; MTD, 1.89 cm), endometrial (5 patients; 10 tumors; MTD, 2.8 cm), vaginal (2 patients; 5 tumors; MTD, 2.40 cm), and cervical (1 patient; 1 tumor; MTD, 1.90 cm) cancers. In order of descending frequency, metastatic tumors treated by TA were located in the liver or liver capsule (74%), lungs (13%), and peritoneal implants (9%). Single tumors were also treated in the kidneys, rectus muscle, perirectal soft tissue (2.5%), and retroperitoneal lymph nodes (1.6%). All efficacy parameters of TA and definitions of major and minor adverse events are categorized by the latest Society of Interventional Radiology reporting standards. RESULTS: The median follow-up of treated patients was 10 months. After the initial ablation, 95.6% of the patients achieved a complete tumor response confirmed by contrast-enhanced magnetic resonance imaging or computed tomography. On surveillance imaging, 8.5% of the ablated tumors developed local progression over a median follow-up period of 4.1 months. Five of 8 tumors with local recurrence underwent repeated treatment over a mean follow-up period of 18 months, and 4 of 5 tumors achieved complete eradication after 1 additional treatment session that resulted in a secondary efficacy of 80%. The overall technique efficacy of TA was 96.2% over a median follow-up period of 10 months. CONCLUSIONS: TA was safe and effective for the local control of metastatic GYN tumors in the lungs, abdomen, and pelvis, with an overall survival rate of 37.5 months and a local progression-free survival rate of 16.5 months, with only 4.8% of treated patients experiencing a major adverse event.


Assuntos
Técnicas de Ablação , Neoplasias dos Genitais Femininos/cirurgia , Cirurgia Assistida por Computador , Técnicas de Ablação/efeitos adversos , Técnicas de Ablação/mortalidade , Adulto , Idoso , Progressão da Doença , Estudos de Viabilidade , Feminino , Neoplasias dos Genitais Femininos/diagnóstico por imagem , Neoplasias dos Genitais Femininos/mortalidade , Neoplasias dos Genitais Femininos/patologia , Humanos , Pessoa de Meia-Idade , Metástase Neoplásica , Recidiva Local de Neoplasia , Intervalo Livre de Progressão , Estudos Retrospectivos , Cirurgia Assistida por Computador/efeitos adversos , Cirurgia Assistida por Computador/mortalidade , Fatores de Tempo
5.
J Vasc Interv Radiol ; 32(8): 1242.e1-1242.e10, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34000388

RESUMO

PURPOSE: To provide guidance on quality improvement thresholds for outcomes and complications of image-guided thermal ablation for the treatment of early stage non-small cell lung cancer, recurrent lung cancer, and metastatic disease. MATERIALS AND METHODS: A multidisciplinary writing group conducted a comprehensive literature search to identify studies on the topic of interest. Data were extracted from relevant studies and thresholds were derived from a calculation of 2 standard deviations from the weighted mean of each outcome. A modified Delphi technique was used to achieve consensus agreement on the thresholds. RESULTS: Data from 29 studies, including systematic reviews and meta-analyses, retrospective cohort studies, and single-arm trials were extracted for calculation of the thresholds. The expert writing group agreed on thresholds for local control, overall survival and adverse events associated with image-guided thermal ablation. CONCLUSION: SIR recommends utilizing the indicator thresholds to review and assess the efficacy of ongoing quality improvement programs. When performance falls above or below specific thresholds, consideration of a review of policies and procedures to assess for potential causes, and to implement changes in practices, may be warranted.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Ablação por Cateter , Neoplasias Pulmonares , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Humanos , Pulmão , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/cirurgia , Recidiva Local de Neoplasia , Melhoria de Qualidade , Radiologia Intervencionista , Estudos Retrospectivos
6.
J Vasc Interv Radiol ; 32(8): 1241.e1-1241.e12, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34332724

RESUMO

PURPOSE: To state the Society of Interventional Radiology's position on the use of image-guided thermal ablation for the treatment of early stage non-small cell lung cancer, recurrent lung cancer, and metastatic disease to the lung. MATERIALS AND METHODS: A multidisciplinary writing group, with expertise in treating lung cancer, conducted a comprehensive literature search to identify studies on the topic of interest. Recommendations were drafted and graded according to the updated SIR evidence grading system. A modified Delphi technique was used to achieve consensus agreement on the recommendation statements. RESULTS: A total of 63 studies, including existing systematic reviews and meta-analysis, retrospective cohort studies, and single-arm trials were identified. The expert writing group developed and agreed on 7 recommendations on the use of image-guided thermal ablation in the lung. CONCLUSION: SIR considers image-guided thermal ablation to be an acceptable treatment option for patients with inoperable Stage I NSCLC, those with recurrent NSCLC, as well as patients with metastatic lung disease.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Ablação por Cateter , Neoplasias Pulmonares , Canadá , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Humanos , Pulmão , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/cirurgia , Recidiva Local de Neoplasia , Radiologia Intervencionista , Estudos Retrospectivos
7.
J Vasc Interv Radiol ; 29(5): 722-728, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29506902

RESUMO

PURPOSE: To determine size of ablation zone and pulmonary hemorrhage in double-freeze (DF) vs modified triple-freeze (mTF) cryoablation protocols with different probe sizes in porcine lung. MATERIALS AND METHODS: In 10 healthy adult pigs, 20 pulmonary cryoablations were performed using either a 2.4-mm or a 1.7-mm probe. Either conventional DF or mTF protocol was used. Serial noncontrast CT scans were performed during ablations. Ablation iceball and hemorrhage volumes were measured and compared between protocols and probe sizes. RESULTS: With 1.7-mm probe, greater peak iceball volume was observed with DF compared with mTF, although difference was not statistically significant (16.1 mL ± 1.9 vs 8.8 mL ± 3.6, P = .07). With 2.4-mm probe, DF and mTF produced similar peak iceball volumes (14.0 mL ± 2.8 vs 14.6 mL ± 2.7, P = .88). Midcycle hemorrhage was significantly larger with DF with the 1.7-mm probe (94.3 mL ± 22.2 vs 19.6 mL ± 2.1, P = .02) and with both sizes combined (93.2 mL ± 17.5 vs. 50.9 mL ± 12.6, P = .048). Rate of hemorrhage increase was significantly higher in DF (10.4 mL/min vs 5.1 mL/min, P = .003). End-cycle hemorrhage was visibly larger in DF compared with mTF across probe sizes, although differences were not statistically significant (P = .14 for 1.7 mm probe, P = .18 for 2.4 mm probe, and P = .07 for both probes combined). Rate of increase in hemorrhage during the last thaw period was not statistically different between DF and mTF (3.0 mL/min vs 2.8 mL/min, P = .992). CONCLUSIONS: mTF reduced rate of midcycle hemorrhage compared with DF. With mTF, midcycle hemorrhage was significantly smaller with 1.7-mm probe; although noticeably smaller with 2.4-mm probe, statistical significance was not achieved. Iceball size was not significantly different across both protocols and probe types.


Assuntos
Criocirurgia/métodos , Hemorragia/etiologia , Pulmão/cirurgia , Animais , Pulmão/diagnóstico por imagem , Modelos Animais , Medição de Risco , Fatores de Risco , Suínos , Tomografia Computadorizada por Raios X
8.
Radiology ; 282(3): 903-912, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27755912

RESUMO

Purpose To identify the variables and factors that affect the quantity and quality of nucleic acid yields from imaging-guided core needle biopsy. Materials and Methods This study was approved by the institutional review board and compliant with HIPAA. The authors prospectively obtained 232 biopsy specimens from 74 patients (177 ex vivo biopsy samples from surgically resected masses were obtained from 49 patients and 55 in vivo lung biopsy samples from computed tomographic [CT]-guided lung biopsies were obtained from 25 patients) and quantitatively measured DNA and RNA yields with respect to needle gauge, number of needle passes, and percentage of the needle core. RNA quality was also assessed. Significance of correlations among variables was assessed with analysis of variance followed by linear regression. Conditional probabilities were calculated for projected sample yields. Results The total nucleic acid yield increased with an increase in the number of needle passes or a decrease in needle gauge (two-way analysis of variance, P < .0001 for both). However, contrary to calculated differences in volume yields, the effect of needle gauge was markedly greater than the number of passes. For example, the use of an 18-gauge versus a 20-gauge biopsy needle resulted in a 4.8-5.7 times greater yield, whereas a double versus a single pass resulted in a 2.4-2.8 times greater yield for 18- versus 20-gauge needles, respectively. Ninety-eight of 184 samples (53%) had an RNA integrity number of at least 7 (out of a possible score of 10). Conclusion With regard to optimizing nucleic acid yields in CT-guided lung core needle biopsies used for genomic analysis, there should be a preference for using lower gauge needles over higher gauge needles with more passes. ©RSNA, 2016 Online supplemental material is available for this article. An earlier incorrect version of this article appeared online. This article was corrected on October 21, 2016.


Assuntos
Genômica , Neoplasias Pulmonares/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha , Feminino , Humanos , Pulmão/patologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
9.
J Vasc Interv Radiol ; 28(2): 213-221, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27979596

RESUMO

PURPOSE: To determine safety and early-term efficacy of CT-guided cryoablation for treatment of recurrent mesothelioma and assess risk factors for local recurrence. MATERIALS AND METHODS: During the period 2008-2012, 24 patients underwent 110 cryoablations for recurrent mesothelioma tumors in 89 sessions. Median patient age was 69 years (range, 48-82 y). Median tumor size was 30 mm (range, 9-113 mm). Complications were graded using Common Terminology Criteria for Adverse Events version 4.0 (CTCAE v4.0). Recurrence was diagnosed on CT or positron emission tomography/CT by increasing size, nodular enhancement, or hypermetabolic activity and analyzed using the Kaplan-Meier method. Cox proportional hazards model was used to determine covariates associated with local tumor recurrence. RESULTS: Median duration of follow-up was 14.5 months. Complications occurred in 8 of 110 cryoablations (7.3%). All but 1 complication were graded CTCAE v4.0 1 or 2. No procedure-related deaths occurred. Freedom from local recurrence was observed in 100% of cases at 30 days, 92.5% at 6 months, 90.8% at 1 year, 87.3% at 2 years, and 73.7% at 3 years. Tumor recurrence was diagnosed 4.5-24.5 months after cryoablation (mean 5.7 months). Risk of tumor recurrence was associated with a smaller ablative margin from the edge of tumor to iceball ablation margin (multivariate hazard ratio 0.68, CI 0.48-0.95, P = .024). CONCLUSIONS: CT-guided cryoablation is safe for local control of recurrent mesothelioma, with a low rate of complications and promising early-term efficacy. A smaller ablative margin may predispose to tumor recurrence.


Assuntos
Criocirurgia/métodos , Neoplasias Pulmonares/cirurgia , Mesotelioma/cirurgia , Recidiva Local de Neoplasia , Neoplasias Pleurais/cirurgia , Idoso , Idoso de 80 Anos ou mais , Criocirurgia/efeitos adversos , Intervalo Livre de Doença , Estudos de Viabilidade , Feminino , Humanos , Estimativa de Kaplan-Meier , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Masculino , Margens de Excisão , Mesotelioma/diagnóstico por imagem , Mesotelioma/patologia , Mesotelioma Maligno , Pessoa de Meia-Idade , Análise Multivariada , Neoplasia Residual , Neoplasias Pleurais/diagnóstico por imagem , Neoplasias Pleurais/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Complicações Pós-Operatórias/etiologia , Modelos de Riscos Proporcionais , Radiografia Intervencionista/métodos , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Carga Tumoral
10.
J Vasc Interv Radiol ; 27(9): 1380-1386, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27566426

RESUMO

PURPOSE: To investigate pulmonary microwave ablation metrics including ablation work, ablation resistance score, and involution. MATERIALS AND METHODS: Retrospective review was performed of 98 pulmonary tumor ablations using the NeuWave Certus Microwave Ablation System (NeuWave Medical, Madison, Wisconsin) in 71 patients (32 men and 39 women; mean age, 64.7 y ± 11.5). Ablation work was defined as sum of (power) * (time) * (number of antennas) for all phases during an ablation procedure. Ablation zone was measured on CT at 3 time points: after procedure, 1-3 months (mean 47 d), and 3-12 months (mean 292 d). Ablation zones were scored based on location for pulmonary lobe (upper = 1, middle/lingula = 2, lower = 3) and region (peripheral = 1, parenchymal = 2, central = 3), and the 2 were summed for ablation resistance score. RESULTS: Ablation zone on CT at 1-3 months was significantly smaller in regions with higher ablation resistance score (P < .05). There was a significant correlation between ablation work and ablation zone measured on CT performed after procedure (P < .001), at 1-3 months (P < .001), and at 3-12 months (P < .05). Ablation zone significantly decreased from after procedure to 1-3 months (P < .001) and from 1-3 months to 3-12 months (P < .001), with change from after procedure to 1-3 months significantly greater (P < .01). CONCLUSIONS: Pulmonary microwave ablation zone is significantly smaller in regions with higher ablation resistance score. Ablation work correlates to ablation zone with a nonlinear involution pattern in the first year and may be useful for planning before the procedure.


Assuntos
Técnicas de Ablação , Neoplasias Pulmonares/cirurgia , Micro-Ondas/uso terapêutico , Técnicas de Ablação/efeitos adversos , Idoso , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/mortalidade , Neoplasias Pulmonares/patologia , Masculino , Micro-Ondas/efeitos adversos , Pessoa de Meia-Idade , Neoplasia Residual , Dinâmica não Linear , Seleção de Pacientes , Valor Preditivo dos Testes , Radiografia Intervencionista/métodos , Estudos Retrospectivos , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Carga Tumoral
11.
J Vasc Interv Radiol ; 26(5): 709-14, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25921453

RESUMO

Thymoma is the most common primary tumor of the anterior mediastinum and often recurs after initial surgical resection. In this case series, percutaneous cryoablation, a locally ablative technique, was used to treat 25 mediastinal and pleural recurrent thymoma lesions in five patients. Safety and short-term efficacy data were collected. In 23 percutaneous cryoablations (92%), there were no or minimal complications. One serious complication, myasthenia gravis flare, occurred. Over the duration of follow-up (median, 331 d), 18 of 20 ablated lesions (90%) showed no evidence of local recurrence. Percutaneous cryoablation shows promise as a safe and effective treatment modality for recurrent thymoma.


Assuntos
Criocirurgia/métodos , Recidiva Local de Neoplasia/cirurgia , Timoma/cirurgia , Neoplasias do Timo/cirurgia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
12.
AJR Am J Roentgenol ; 199(6): 1247-51, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23169715

RESUMO

OBJECTIVE: The objective of our study was to determine whether vascular enhancement and image quality can be preserved in pulmonary CT angiography (CTA) performed on a 64-MDCT scanner with 30 mL of IV contrast material. MATERIALS AND METHODS: This retrospective matched-cohort study compared image quality of pulmonary CTA performed using 30 mL of IV contrast material versus 100 mL of IV contrast material. CT images of 50 patients (46 men, four women; mean age, 66 years) who underwent pulmonary CTA on a 64-MDCT scanner using a low dose (30 mL) of iodixanol 320 and another 50 patients (49 men, one woman; mean age, 65 years) who underwent pulmonary CTA using a regular dose (100 mL) of contrast material during the same time period were selected for review. The 30- and 100-mL pulmonary CTA studies were retrospectively evaluated by two thoracic radiologists in random order. Attenuation values were recorded over the main, right main, selected lobar, segmental, and subsegmental pulmonary arteries. Image quality was also subjectively assessed using visual scores on a scale from 1 (nondiagnostic) to 5 (excellent). RESULTS: The average attenuation measurements of the main, right main, selected lobar, segmental, and subsegmental pulmonary arteries were 260, 262, 280, 316, and 338 HU, respectively, on the 30-mL studies and 313, 301, 316, 344, and 349 HU, respectively, on the 100-mL studies. The average visual score was 4.0 for both the 30- and 100-mL groups. A visual score of 4 or 5 was given to 82% of studies in the 30-mL group and 78% of studies in the 100-mL group. CONCLUSION: Contrast agent dose for pulmonary CTA using a 64-MDCT scanner can be significantly reduced without compromising diagnostic image quality.


Assuntos
Angiografia/métodos , Meios de Contraste/administração & dosagem , Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Ácidos Tri-Iodobenzoicos/administração & dosagem , Idoso , Algoritmos , Feminino , Humanos , Masculino , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Estatísticas não Paramétricas
13.
Radiographics ; 32(4): 947-69, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22786987

RESUMO

Radiofrequency ablation (RFA) is used to treat pulmonary malignancies. Although preliminary results are suggestive of a survival benefit, local progression rates are appreciable. Because a patient can undergo repeat treatment if recurrence is detected early, reliable post-RFA imaging follow-up is critical. The purpose of this article is to describe (a) an algorithm for post-RFA imaging surveillance; (b) the computed tomographic (CT) appearance, size, enhancement, and positron emission tomographic (PET) metabolic activity of the ablation zone; and (c) CT, PET, and dual-modality imaging with PET and CT (PET/CT) features suggestive of partial ablation or tumor recurrence and progression. CT is routinely used for post-RFA follow-up. PET and PET/CT have emerged as auxiliary follow-up techniques. CT with nodule densitometry may be used to supplement standard CT. Post-RFA follow-up was divided into three phases: early (immediately after to 1 week after RFA), intermediate (>1 week to 2 months), and late (>2 months). CT and PET imaging features suggestive of residual or recurrent disease include (a) increasing contrast material uptake in the ablation zone (>180 seconds on dynamic images), nodular enhancement measuring more than 10 mm, any central enhancement greater than 15 HU, and enhancement greater than baseline anytime after ablation; (b) growth of the RFA zone after 3 months (compared with baseline) and definitely after 6 months, peripheral nodular growth and change from ground-glass opacity to solid opacity, regional or distant lymph node enlargement, and new intrathoracic or extrathoracic disease; and (c) increased metabolic activity beyond 2 months, residual activity centrally or at the ablated tumor, and development of nodular activity.


Assuntos
Ablação por Cateter/métodos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/cirurgia , Pneumonectomia/métodos , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Prognóstico , Resultado do Tratamento
14.
Acad Radiol ; 29(9): 1413-1416, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35094948

RESUMO

RATIONALE AND OBJECTIVES: Promotion is an important milestone in the career of academic radiologists. Appointments, Promotion and Tenure (APT) committees require multiple letters of support from both internal and external referees. Traditional narrative letters are highly subjective, have high inter-reader variability, are time-intensive, and vulnerable to gender and other biases. The Alliance of Directors and Vice Chairs of Education in Radiology (ADVICER) recognized the need for a standardized template to assist academic faculty, letter writers, and APT committees. MATERIALS AND METHODS: An ADVICER ad hoc committee of six educators with experience serving as external referees was convened to create a standardized template. Committee members performed a search of the relevant literature and internet sites, spoke with stakeholders such as APT chairs, and ultimately developed a template for faculty reviewer letters using the common clinician-educator pathway as a focal point. RESULTS: An open source, modifiable, standardized, template was produced. The template has been made available to ADVICER members and is available on the Association of University Radiologists (AUR) website at: https://www.aur.org/resources/Template-for-Faculty-Reviewer-Letters-for-Promotion-and-Appointment CONCLUSION: This external referee template has the potential to reduce subjectivity, eliminate bias, and provide a flexible, modifiable, comprehensive faculty review letter template which will be useful for academic faculty, letter writers, and promotions committees.


Assuntos
Docentes , Radiologia , Mobilidade Ocupacional , Docentes de Medicina , Humanos , Radiologia/educação
15.
Transl Lung Cancer Res ; 11(2): 150-164, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35280317

RESUMO

Background: Transbronchial microwave ablation (MWA) is a promising novel therapy. Despite advances in bronchoscopy and virtual navigation, real time image guidance of probe delivery is lacking, and distal maneuverability is limited. Cone-beam computed tomography (CBCT) based augmented fluoroscopy guidance using steerable sheaths may help overcome these shortcomings. The aim of this study was to evaluate feasibility and accuracy of augmented fluoroscopy guided transbronchial MWA with a steerable sheath and without a bronchoscope. Methods: In this prospective study, procedures were performed under general anesthesia. Extra-bronchial lung synthetic targets were placed percutaneously. Target and airways extracted from CBCT, with planned bronchial parking point close to the target were overlaid on live fluoroscopy. Endobronchial navigation was solely performed under augmented fluoroscopy guidance. A 6.5 Fr steerable sheath was parked in the bronchus per plan, and a flexible MWA probe was inserted coaxially then advanced through the bronchus wall towards the target. Final in-target position was confirmed by CBCT. Only one ablation of 100 W-5 min was performed per target. Animals were euthanized and pathology analysis of the lungs was performed. Results: Eighteen targets with a median largest diameter of 9 mm (interquartile range, 7-11 mm) were ablated in 9 pigs. Median needle-target center distance was 2 mm (interquartile range, 0-4 mm), and was higher for lower/middle than for upper lobes [0 mm (interquartile range, 0-4 mm) vs. 4 mm (interquartile range, 3-8 mm), P=0.04]. No severe complications or pneumothorax occurred. Two cases of rib fractures in the ablation zone resolved after medical treatment. Median longest axis of the ablation zone on post-ablation computed tomography was 38 mm (interquartile range, 30-40 mm). Histology showed coagulation necrosis of ablated tissue. Conclusions: Transbronchial MWA under augmented fluoroscopy guidance using a steerable sheath is feasible and accurate.

16.
Radiographics ; 30(5): 1163-81, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20833843

RESUMO

Lung cancer is the leading cause of cancer-related deaths worldwide, with a dismal 5-year survival rate of 15%. The TNM (tumor-node-metastasis) classification system for lung cancer is a vital guide for determining treatment and prognosis. Despite the importance of accuracy in lung cancer staging, however, correct staging remains a challenging task for many radiologists. The new 7th edition of the TNM classification system features a number of revisions, including subdivision of tumor categories on the basis of size, differentiation between local intrathoracic and distant metastatic disease, recategorization of malignant pleural or pericardial disease from stage III to stage IV, reclassification of separate tumor nodules in the same lung and lobe as the primary tumor from T4 to T3, and reclassification of separate tumor nodules in the same lung but not the same lobe as the primary tumor from M1 to T4. Radiologists must understand the details set forth in the TNM classification system and be familiar with the changes in the 7th edition, which attempts to better correlate disease with prognostic value and treatment strategy. By recognizing the relevant radiologic appearances of lung cancer, understanding the appropriateness of staging disease with the TNM classification system, and being familiar with potential imaging pitfalls, radiologists can make a significant contribution to treatment and outcome in patients with lung cancer.


Assuntos
Diagnóstico por Imagem/métodos , Neoplasias Pulmonares/classificação , Neoplasias Pulmonares/patologia , Estadiamento de Neoplasias/métodos , Humanos
17.
J Clin Oncol ; 38(14): 1633-1640, 2020 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-32134701

RESUMO

PURPOSE: National Cancer Institute (NCI)-sponsored clinical trial network studies frequently require biopsy specimens for pharmacodynamic and molecular biomarker analyses, including paired pre- and post-treatment samples. The purpose of this meeting of NCI-sponsored investigators was to identify local institutional standard procedures found to ensure quantitative and qualitative specimen adequacy. METHODS: NCI convened a conference on best biopsy practices, focusing on the clinical research community. Topics discussed were (1) criteria for specimen adequacy in the personalized medicine era, (2) team-based approaches to ensure specimen adequacy and quality control, and (3) risk considerations relevant to academic and community practitioners and their patients. RESULTS AND RECOMMENDATIONS: Key recommendations from the convened consensus panel included (1) establishment of infrastructure for multidisciplinary biopsy teams with a formalized information capture process, (2) maintenance of standard operating procedures with regular team review, (3) optimization of tissue collection and yield methodology, (4) incorporation of needle aspiration and other newer techniques, and (5) commitment of stakeholders to use of guideline documents to increase awareness of best biopsy practices, with the goal of universally improving tumor biopsy practices.


Assuntos
Biópsia/métodos , Ensaios Clínicos como Assunto/métodos , Neoplasias Hepáticas/cirurgia , Neoplasias Pulmonares/cirurgia , Humanos , National Cancer Institute (U.S.) , Resultado do Tratamento , Estados Unidos
18.
J Thorac Oncol ; 15(7): 1200-1209, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32151777

RESUMO

OBJECTIVE: To assess the safety and local recurrence-free survival in patients after cryoablation for treatment of pulmonary metastases. METHODS: This multicenter, prospective, single-arm, phase 2 study included 128 patients with 224 lung metastases treated with percutaneous cryoablation, with 12 and 24 months of follow-up. The patients were enrolled on the basis of the outlined key inclusion criteria, which include one to six metastases from extrapulmonary cancers with a maximal diameter of 3.5 cm. Time to progression of the index tumor(s), metastatic disease, and overall survival rates were estimated using the Kaplan-Meier method. Complications were captured for 30 days after the procedure, and changes in performance status and quality of life were also evaluated. RESULTS: Median size of metastases was 1.0 plus or minus 0.6 cm (0.2-4.5) with a median number of tumors of 1.0 plus or minus 1.2 cm (one to six). Local recurrence-free response (local tumor efficacy) of the treated tumor was 172 of 202 (85.1%) at 12 months and 139 of 180 (77.2%) at 24 months after the initial treatment. After a second cryoablation treatment for recurrent tumor, secondary local recurrence-free response (local tumor efficacy) was 184 of 202 (91.1%) at 12 months and 152 of 180 (84.4%) at 24 months. Kaplan-Meier estimates of 12- and 24-month overall survival rates were 97.6% (95% confidence interval: 92.6-99.2) and 86.6% (95% confidence interval: 78.7-91.7), respectively. Rate of pneumothorax that required pleural catheter placement was 26% (44/169). There were eight grade 3 complication events in 169 procedures (4.7%) and one (0.6%) grade 4 event. CONCLUSION: Percutaneous cryoablation is a safe and effective treatment for pulmonary metastases.


Assuntos
Criocirurgia , Neoplasias Renais , Neoplasias Pulmonares , Humanos , Neoplasias Renais/cirurgia , Neoplasias Pulmonares/cirurgia , Recidiva Local de Neoplasia/cirurgia , Estudos Prospectivos , Qualidade de Vida , Estudos Retrospectivos , Resultado do Tratamento
19.
Radiology ; 252(2): 468-76, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19703884

RESUMO

PURPOSE: To evaluate the increase in cardiac x-ray computed tomographic (CT) research and the relative contributions of radiologists and cardiologists. MATERIALS AND METHODS: This observational study of public data was exempt from institutional review board approval. The National Library of Medicine MEDLINE database was searched for articles published between 1996 and 2006 in which CT was used to acquire images of the heart. The date and journal of publication, authors' specialty and country, and article type were recorded. Trends were evaluated by using regression analysis, with P < or = .05 indicating a significant difference. RESULTS: A total of 1270 articles were identified. Basic science research articles, review articles, case reports, and reports of clinical trials constituted 38%, 19%, 11%, and 7% of the total, respectively. The number of journal articles increased 15.4-fold and increased exponentially at a rate of 28% per year (P < .001). An exponential increase was seen in the number of basic science articles (P < .001), review articles (P < .001), case reports (P < .001), and reports of clinical trials (P < .001). Articles from the United States (n = 464), Germany (n = 260), Japan (n = 125), and The Netherlands (n = 76) constituted 72.8% of the world total. Radiologists published more articles (378 vs 319) and more general research articles (143 vs 100) than did cardiologists; however, cardiologists published more case reports (50 vs 29) and clinical trials (22 vs 18) than did radiologists. Cardiologists wrote more articles than did radiologists in the United States (112 vs 95) and Japan (31 vs 22), whereas radiologists wrote more articles than did cardiologists in Germany (126 vs 53) and The Netherlands (34 vs 31). CONCLUSION: Cardiac CT research is increasing exponentially and is conducted primarily in four countries. Both radiologists and cardiologists make important contributions; however, contributions vary according to the research method used and the country in which the study was conducted. Both factors may influence future clinical adoption patterns.


Assuntos
Pesquisa Biomédica/estatística & dados numéricos , Pesquisa Biomédica/tendências , Cardiologia/estatística & dados numéricos , Cardiologia/tendências , Publicações Periódicas como Assunto/estatística & dados numéricos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Tomografia Computadorizada por Raios X/tendências , Bibliometria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA