Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
J Appl Clin Med Phys ; 24(10): e14130, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37646429

RESUMO

Concept inventories are multiple choice exams designed with the intention to test core concepts on specific subjects and evaluate common misconceptions. These tests serve as a useful tool in the classroom to assess value added by the instructor's educational methods and to better understand how students learn. They can provide educators with a method to evaluate their current teaching strategies and to make modifications that enhance student learning and ultimately elevate the quality of medical physics education. The use of concept inventories in introductory college physics courses revealed important gaps in conceptual understanding of physics by undergraduate students and motivated a shift of physics teaching towards more effective methods, such as active learning techniques. The goal of this review is to introduce medical physicists to concept inventories as educational evaluation tools and discuss potential applications to medical physics education by development through multi-institutional collaboration.

5.
J Appl Clin Med Phys ; 17(4): 3-14, 2016 07 08.
Artigo em Inglês | MEDLINE | ID: mdl-27455473

RESUMO

The goal of this report is to provide a framework from which an institution can develop a competency and credentialing program. It is not intended to be adopted as written, but rather as a list of suggestions from which the institution develops their program. A clear distinction should be made between the initial evaluation of the competency of new staff (credentialing) and the ongoing verification of the competency of existing staff. Furthermore, whenever new technologies are imple-mented, the entire staff would be subject to the credentialing process. Competencies involve the ongoing verification of the performance of a procedure according to the established policies and procedures at a facility. This can be done by audits of work product, direct observation of performance, self-evaluation, or testing. PACS number(s): 87.10.-e, 87.90.+y


Assuntos
Competência Clínica/normas , Estudos de Avaliação como Assunto , Física Médica/normas , Guias de Prática Clínica como Assunto/normas , Garantia da Qualidade dos Cuidados de Saúde/normas , Radioterapia (Especialidade) , Humanos , Estados Unidos
6.
Med Phys ; 48(6): e86-e114, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33780010

RESUMO

With the advancement of data-intensive technologies, such as image-guided radiation therapy (IGRT) and intensity-modulated radiation therapy (IMRT), the amount and complexity of data to be transferred between clinical subsystems have increased beyond the reach of manual checking. As a result, unintended treatment deviations (e.g., dose errors) may occur if the treatment system is not closely monitored by a comprehensive data transfer quality management program (QM). This report summarizes the findings and recommendations from the task group (TG) on quality assurance (QA) of external beam treatment data transfer (TG-201), with the aim to assist medical physicists in designing their own data transfer QM. As a background, a section of this report describes various models of data flow (distributed data repositories and single data base systems) and general data test characteristics (data integrity, interpretation, and consistency). Recommended tests are suggested based on the collective experience of TG-201 members. These tests are for the acceptance of, commissioning of, and upgrades to subsystems that store and/or modify clinical treatment data. As treatment complexity continues to evolve, we will need to do and know more about ensuring the quality of data transfers. The report concludes with the recommendation to move toward data transfer open standards compatibility and to develop tools that automate data transfer QA.


Assuntos
Radioterapia Guiada por Imagem , Radioterapia de Intensidade Modulada , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Relatório de Pesquisa , Estados Unidos
7.
Med Phys ; 48(11): e927-e968, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34287961

RESUMO

While most Radiation Oncology clinics have adopted electronic charting in one form or another, no consensus document exists that provides guidelines for safe and effective use of the Radiation Oncology electronic medical records (RO-EMR). Task Group 262 was formed to provide these guidelines as well as to provide recommendations to vendors for improving electronic charting functionality in future. Guidelines are provided in the following areas: Implementation and training for the RO-EMR, acceptance testing and quality assurance (QA) of the RO-EMR, use of the RO-EMR as an information repository, use of the RO-EMR as a workflow manager, electronic charting for brachytherapy and nonstandard treatments, and information technology (IT) considerations associated with the RO-EMR. The report was based on a literature search by the task group, an extensive survey of task group members on their respective RO-EMR practices, an AAPM membership survey on electronic charting, as well as group consensus.


Assuntos
Braquiterapia , Radioterapia (Especialidade) , Registros Eletrônicos de Saúde , Eletrônica , Planejamento da Radioterapia Assistida por Computador , Relatório de Pesquisa
8.
Med Dosim ; 45(4): 393-399, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32807611

RESUMO

The purpose of this study was to develop and implement a custom-designed electronic workflow management tool created by Medlever, Inc, in order to improve efficiency, leverage interoperability and maximize overall labor resources. Administrators and clinicians from five Banner MD Anderson Cancer Center, Department of Radiation Oncology clinics utilized Medlever, Inc. to track and analyze clinical workflow. Real-time data were collected for the duration of 3 months. Time and process data were compared month-to-month from each of the five Banner MD Anderson facilities. The data were quantified based on efficiency scores, where efficiency score was defined by measured timelines for work completion, which was defined by average measured times to complete clinical process steps. The overall average efficiency score for the clinical process steps were as follows: simulation - 66%, define target volume - 69%, creating a treatment plan - 71%, plan review - 76%, finalizing plan - 81%, physics review - 73%, IMRT QA - 72%, approving treatment plan - 69%, and therapy chart check - 66%. The combined average efficiency scores for facility A through E were approximately 72%, 77%, 82%, 66%, and 60%, respectively. Overall, the average sum of all clinical efficiency scores for the radiation oncology service line for all five facilities was approximately 73%. The results set the base line for efficiency and can be evaluated in future studies. In conclusion, a workflow management tool is an effective system to provide results for real-time data tracking, opportunities of improved efficiency, and evidence-based approaches to workflow decision making.


Assuntos
Radioterapia (Especialidade) , Humanos , Planejamento da Radioterapia Assistida por Computador , Fluxo de Trabalho
9.
Med Phys ; 35(12): 5471-89, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19175107

RESUMO

While ultrasound guided prostate brachytherapy has gained wide acceptance as a primary treatment tool for prostate cancer, quality assurance of the ultrasound guidance system has received very little attention. Task Group 128 of the American Association of Physicists in Medicine was created to address quality assurance requirements specific to transrectal ultrasound used for guidance of prostate brachytherapy. Accurate imaging guidance and dosimetry calculation depend upon the quality and accuracy of the ultrasound image. Therefore, a robust quality assurance program for the ultrasound system is essential. A brief review of prostate brachytherapy and ultrasound physics is provided, followed by a recommendation for elements to be included in a comprehensive test phantom. Specific test recommendations are presented, covering grayscale visibility, depth of penetration, axial and lateral resolution, distance measurement, area measurement, volume measurement, needle template/electronic grid alignment, and geometric consistency with the treatment planning computer.


Assuntos
Braquiterapia/métodos , Braquiterapia/normas , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Ultrassonografia/métodos , Ultrassonografia/normas , Artefatos , Desenho de Equipamento , Humanos , Masculino , Imagens de Fantasmas , Próstata/diagnóstico por imagem , Garantia da Qualidade dos Cuidados de Saúde , Controle de Qualidade , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Reprodutibilidade dos Testes , Software
10.
Int J Radiat Oncol Biol Phys ; 67(2): 342-6, 2007 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-17236959

RESUMO

PURPOSE: To analyze the role of dosimetric quality parameters in maximizing cancer eradication in higher risk prostate cancer patients treated with palladium (Pd)-103 and supplemental beam radiation. METHODS: One-hundred-seventy-nine patients treated with Pd-103 and supplemental beam radiation, with minimum 2 years follow-up prostate-specific antigen (PSA) values and posttreatment computed tomography scans were analyzed. Dosimetric parameters included the V100 (percent of the postimplant volume covered by the prescription dose), the D90 (the minimum dose that covered 90% of the post implant volume), and the treatment margins (the radial distance between the prostatic edge and the prescription isodose). Treatment margins (TMs) were calculated using premarket software. RESULTS: Freedom from biochemical failure was 79% at 3 years, with 92 of the 179 patients (51%) followed beyond 3 years. In comparing patients who did or did not achieve biochemical control, the most striking differences were in biologic factors of pretreatment PSA and Gleason score. The V100, D90, and average TM all showed nonsignificant trends to higher values in patients with biochemical control. In multivariate analysis of each of the three dosimetric parameters against PSA and Gleason score, TM showed the strongest correlation with biochemical control (p = 0.19). CONCLUSIONS: For patients with intermediate and high-risk prostate cancer treated with Pd-103 brachytherapy and external beam radiation, biologic factors (PSA and Gleason score) were the most important determinants of cancer eradication. However, there is a trend to better outcomes among patients with higher quality implant parameters, suggesting that attention to implant quality will maximize the likelihood of cure.


Assuntos
Braquiterapia/métodos , Paládio/uso terapêutico , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/radioterapia , Radioisótopos/uso terapêutico , Braquiterapia/normas , Intervalo Livre de Doença , Humanos , Masculino , Análise Multivariada , Neoplasias da Próstata/sangue , Neoplasias da Próstata/mortalidade , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X
11.
Brachytherapy ; 15(5): 570-7, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27364873

RESUMO

PURPOSE: There is a lack of prescriptive, practical information for those doing the work of commissioning high-dose-rate (HDR) gynecologic (GYN) treatment equipment. The purpose of this work is to develop a vendor-neutral, consensus-based, commissioning template to improve standardization of the commissioning process. METHODS AND MATERIALS: A series of commissioning procedures and tests specific to HDR GYN treatments were compiled within one institution. The list of procedures and tests was then sent to five external reviewers at clinics engaged in HDR GYN treatments. External reviewers were asked to (1) suggest deletions, additions, and improvements/modifications to descriptions, (2) link the procedures and tests to common, severe failure modes based on their effectiveness at mitigating those failure modes, and (3) rank the procedures and tests based on perceived level of importance. RESULTS: External reviewers suggested the addition of 14 procedures and tests. The final template consists of 67 procedures and tests. "Treatment process" and "staff training" sections were identified as mitigating the highest number of commonly reported failure modes. The mean perceived importance for all procedures and tests was 4.4 of 5, and the mean for each section ranged from 3.6 to 4.8. Sections of the template that were identified as mitigating the highest number of commonly reported failure modes were not assigned the highest perceived importance. CONCLUSION: The commissioning template developed here provides a standardized approach to process and equipment commissioning. The discord between perceived importance and mitigation of the highest number of failure modes suggests that increased focus should be placed on procedures and tests in "treatment process" and "staff training" sections.


Assuntos
Braquiterapia/normas , Consenso , Neoplasias dos Genitais Femininos/radioterapia , Braquiterapia/instrumentação , Braquiterapia/métodos , Feminino , Pessoal de Saúde/educação , Humanos
12.
Int J Radiat Oncol Biol Phys ; 95(4): 1298-303, 2016 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-27354135

RESUMO

PURPOSE: The American Society for Radiation Oncology (ASTRO) Physics Core Curriculum Subcommittee (PCCSC) has updated the recommended physics curriculum for radiation oncology resident education to improve consistency in teaching, intensity, and subject matter. METHODS AND MATERIALS: The ASTRO PCCSC is composed of physicists and physicians involved in radiation oncology residency education. The PCCSC updated existing sections within the curriculum, created new sections, and attempted to provide additional clinical context to the curricular material through creation of practical clinical experiences. Finally, we reviewed the American Board of Radiology (ABR) blueprint of examination topics for correlation with this curriculum. RESULTS: The new curriculum represents 56 hours of resident physics didactic education, including a 4-hour initial orientation. The committee recommends completion of this curriculum at least twice to assure both timely presentation of material and re-emphasis after clinical experience. In addition, practical clinical physics and treatment planning modules were created as a supplement to the didactic training. Major changes to the curriculum include addition of Fundamental Physics, Stereotactic Radiosurgery/Stereotactic Body Radiation Therapy, and Safety and Incidents sections, and elimination of the Radiopharmaceutical Physics and Dosimetry and Hyperthermia sections. Simulation and Treatment Verification and optional Research and Development in Radiation Oncology sections were also added. A feedback loop was established with the ABR to help assure that the physics component of the ABR radiation oncology initial certification examination remains consistent with this curriculum. CONCLUSIONS: The ASTRO physics core curriculum for radiation oncology residents has been updated in an effort to identify the most important physics topics for preparing residents for careers in radiation oncology, to reflect changes in technology and practice since the publication of previous recommended curricula, and to provide practical training modules in clinical radiation oncology physics and treatment planning. The PCCSC is committed to keeping the curriculum current and consistent with the ABR examination blueprint.


Assuntos
Currículo , Internato e Residência , Física/educação , Radioterapia (Especialidade)/educação , Humanos , Sociedades Médicas
13.
Int J Radiat Oncol Biol Phys ; 62(1): 170-4, 2005 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-15850918

RESUMO

PURPOSE: To analyze the effect of high-dose regions on biochemical cancer control rates after prostate brachytherapy. METHODS AND MATERIALS: Patients with 1997 American Joint Committee on Cancer clinical Stage T1c-T2a prostate carcinoma (Gleason grade 5-6, prostate-specific antigen level 4-10 ng/mL) were randomized to implantation with 125I (144 Gy) vs. 103Pd (125 Gy, National Institute of Standards and Technology 1999). Isotope implantation was performed by standard techniques, using a modified peripheral loading pattern. Of the 313 patients entered in the protocol, 270 were included in this analysis. The 125I source strength ranged from 0.4 to 0.89 mCi (median, 0.55 mCi), and the 103Pd source strength ranged from 1.3 to 1.6 mCi (median, 1.5 mCi). CT was performed within 4 h after implantation. The dosimetric parameters analyzed included the percentage of the postimplant prostate volume covered by the 100%, 150%, 200%, and 300% prescription dose (V100, V150, V200, and V300, respectively). The median time to the last follow-up for patients without failure was 2.7 years. Freedom from biochemical failure was defined as a serum prostate-specific antigen level of < or =0.5 ng/mL at last follow-up. Patients were censored at last follow-up if their serum prostate-specific antigen level was still decreasing. RESULTS: The mean V100, V150, V200, and V300 value was 90% (+/-8%), 63% (+/-14), 35% (+/-13%), and 14% (+/-7%), respectively. Patients with a V100 of > or =90% had a 3-year freedom from biochemical failure rate of 96% vs. 87% for those with a V100 of <90% (p=0.0029). Overall, patients with more high-dose regions had a greater chance of biochemical control. However, when only patients with a V100 of > or =90% were analyzed, no relationship was found between higher dose regions and the likelihood of cancer control. This lack of effect on biochemical control was apparent for both isotopes. CONCLUSION: High-dose regions do not appear to affect cancer control rates, as long as >90% of the prostate volume is covered by the prescription dose.


Assuntos
Braquiterapia , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/radioterapia , Humanos , Radioisótopos do Iodo/uso terapêutico , Masculino , Paládio/uso terapêutico , Neoplasias da Próstata/sangue , Radioisótopos/uso terapêutico , Dosagem Radioterapêutica , Falha de Tratamento
14.
Int J Radiat Oncol Biol Phys ; 63(5): 1469-73, 2005 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-16137839

RESUMO

PURPOSE: To determine if postimplant prostate brachytherapy treatment margins calculated on Day 0 differ substantially from those calculated on Day 30. METHODS: Thirty patients with 1997 American Joint Commission on Cancer clinical stage T1-T2 prostatic carcinoma underwent prostate brachytherapy with I-125 prescribed to 144 Gy. Treatment planning methods included using loose seeds in a modified peripheral loading pattern and treatment margins (TMs) of 5-8 mm. Postimplant plain radiographs, computed tomography scans, and magnetic resonance scans were obtained 1-4 hours after implantation (Day 0). A second set of imaging studies was obtained at 30 days after implantation (Day 30) and similarly analyzed. Treatment margins were measured as the radial distance in millimeters from the prostate edge to the 100% isodose line. The TMs were measured and tabulated at 90 degrees intervals around the prostate periphery at 0.6-cm intervals. Each direction was averaged to obtain the mean anterior, posterior, left, and right margins. RESULTS: The mean overall TM increased from 2.6 mm (+/-2.3) on Day 0 to 3.5 mm (+/-2.4) on Day 30. The mean anterior margin increased from 1.2 mm on Day 0 to 1.8 mm on Day 30. The posterior margin increased from 1.2 mm on Day 0 to 2.8 mm on Day 30. The lateral treatment margins increased most over time, with mean right treatment margin increasing from 3.9 mm on Day 0 to 4.7 mm on Day 30. CONCLUSION: Treatment margins appear to be durable in the postimplant period, with a clinically insignificant increase from Day 0 to Day 30.


Assuntos
Braquiterapia/efeitos adversos , Edema/patologia , Doenças Prostáticas/patologia , Neoplasias da Próstata/radioterapia , Edema/etiologia , Humanos , Masculino , Próstata/patologia , Doenças Prostáticas/etiologia , Neoplasias da Próstata/patologia , Dosagem Radioterapêutica
15.
Radiother Oncol ; 75(3): 307-10, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16086912

RESUMO

BACKGROUND AND PURPOSE: While favorable results are achieved with combined modality irradiation, there has never been a rigorous study of the need for supplemental beam. The study reported here compares clinical outcomes with substantially different external beam radiation doses. Similar to classic randomized Wilm's tumor studies from the 1980s, the intention of the trial design was to decrementally test the need for beam radiation. PATIENTS AND METHODS: As of June 2000, 165 of a planned 600 patients with 1997 AJC clinical stage T1c-T2a prostatic carcinoma, Gleason grade 7-10 and/or PSA 10-20 ng/ml, were treated on a randomized protocol comparing 44 versus 20 Gy pre-implant supplemental beam radiation, combined with Pd-103, 90 versus 115 Gy, respectively (NIST-1999). Freedom from biochemical failure was defined as a serum PSA0.5 ng/ml were scored as failures at the time at which their PSA nadired. The follow-up period for non-failing patients ranged from 0.5 to 4.9 years (median: 2.9 years). Accrual of 566 patients was achieved in October 2004. The study was closed at that time because of slowing accrual, due in part to the findings reported here. RESULTS: The overall actuarial freedom from biochemical progression at 3 years is 85%, with 59 patients followed beyond 3 years. A total of 21 patients have developed biochemical failure, 12 treated with 20 Gy and nine treated with 44 Gy. There were no clinically evident local failures. The actuarial biochemical freedom-from-failure rate at 3 years was 83% for 20 Gy patients versus 88% for 44 Gy patients (P=0.64). For 112 patients with a pre-treatment PSA<10 ng/ml, the 3-year freedom from progression was 84% in patients receiving 20 Gy beam radiation versus 94% in those who received 44 Gy beam (P=0.16). For 47 patients with a pre-treatment PSA>10 ng/ml, the 3-year freedom from progression was 82% in patients receiving 20 Gy beam radiation versus 72% in those who received 44 Gy beam (P=0.38). CONCLUSIONS: The randomized data presented here suggests that the likelihood of biochemical cure is similar with standard (44 Gy) or lower dose (20 Gy) supplemental beam radiation. Since the biological effect of 20 Gy external beam radiation is likely to be small, we interpret these preliminary results to suggest that supplemental beam radiation is unnecessary, in the setting of a high degree of prostate coverage by the brachytherapy prescription dose. With closure of this study, we have begun treating intermediate and high risk patients on a prospective randomized comparison of Pd-103 with 20 versus 0 Gy supplemental beam radiation.


Assuntos
Braquiterapia , Paládio/uso terapêutico , Neoplasias da Próstata/radioterapia , Radioisótopos/uso terapêutico , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/sangue , Dosagem Radioterapêutica
16.
Health Phys ; 108(2): 224-41, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25551506

RESUMO

In radiation therapy, unlike most other applications involving radiation, the intention is to deliver high doses of radiation to diseased tissue, constrained by the effects of radiation to healthy tissue. With regard to patient exposure, the radiation protection framework of justification, optimization, and limitation is a direct part of the prescription process of radiation therapy. Staff and public exposures are typically far below occupational maximum permissible exposures. However, a number of other issues arise in radiation therapy that fall into the category of radiation protection. After an historical review, this paper discusses several contemporary and emerging concerns within radiation therapy, including fetal dose, secondary malignancies, and dose to implantable devices, all of which involve accurate dose assessment outside the intended treatment volume. Other concerns include quality and safety, molecularly based disease assessment and treatment, and other novel treatment strategies. The paper ends with a discussion of the interplay between best practices and regulatory oversight.


Assuntos
Neoplasias/radioterapia , Proteção Radiológica/métodos , Radioterapia/métodos , Braquiterapia/métodos , Exposição Ambiental/prevenção & controle , Feminino , Feto/efeitos da radiação , Órgãos Governamentais , Humanos , Erros Médicos , Neoplasias Induzidas por Radiação/prevenção & controle , Exposição Ocupacional , Gravidez , Complicações na Gravidez , Controle de Qualidade , Radiação , Doses de Radiação , Medição de Risco , Resultado do Tratamento , Estados Unidos
17.
Pract Radiat Oncol ; 5(5): e423-e429, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26231597

RESUMO

PURPOSE: The purpose of this study is to report an overview of the patterns of practice for safety-critical processes in radiation oncology clinics in the United States. METHODS AND MATERIALS: The Safety Profile Assessment (spa.aapm.org), developed by the American Association of Physicists in Medicine, was released in July 2013. It consists of 92 indicator questions designed to assess the safety and quality of radiation oncology operations. By December 2014, 114 surveys had been completed by clinics within the United States. This database was analyzed to identify those indicators of safety and quality performance with which there was the highest degree of compliance and those indicators with which there was the least. Additionally, we assessed the extent to which key clinical activities were supported by formal policies. Voluntary post assessment surveys were completed by 86 respondents (75%). RESULTS: The mean number of patients treated per day on external beam radiation therapy devices was 64 (range, 8-600) in the clinics that responded to the survey. The average overall score for the 92 SPA indicator questions was 1.45 (range, 1.00-2.78) on a 5-point scale, with 1 being the most positive. Those indicators that were associated with the highest levels of compliance are dominated by activities that are either strongly recommended, regulated, or associated with revenue generation. Surprisingly, several of those indicators for which there was the least compliance relate to activities that are known to have contributed to serious radiation therapy misadministrations in the past. Formal policies, which are widely regarded as a backbone of a safe clinical system, were reported as lacking for some safety-critical procedures. CONCLUSIONS: Although overall this analysis demonstrated reasonable performance across participating departments, several important areas for improvement were identified. The results may guide the allocation of resources both at the level of individual departments and at the professional society level.


Assuntos
Pesquisas sobre Atenção à Saúde/métodos , Radioterapia (Especialidade)/normas , Feminino , Humanos , Masculino , Estados Unidos
18.
Pract Radiat Oncol ; 5(2): 127-34, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25748005

RESUMO

PURPOSE: It is challenging for the radiation oncology practitioner to manage and implement the plethora of recently generated recommendations on quality and safety improvement. The online Safety Profile Assessment (SPA) tool uses an easy-to-use question-and-answer format to assess safety/quality within a clinic, provide a way to benchmark against peers, and facilitate improvement. This report describes the design and development of the SPA and experience from the first year of use. METHODS: Performance indicators for the SPA were derived from 4 foundations: the Agency for Healthcare Research and Quality, a review of 7 recent authoritative documents specific to radiation oncology, a recent American Association of Physicists in Medicine report on incident learning, and the American College of Radiology-American Society for Radiation Oncology accreditation system as of 2011. After pilot testing, the free-access tool was launched through the American Association of Physicists in Medicine website (http://spa.aapm.org) in July 2013. Questionnaire data were collected to assess the experience of users. RESULTS: The SPA tool consists of 92 indicators designed to probe safety and quality. A clinic's performance is benchmarked against all other responses in the database, and aided by a downloadable log, quality/safety improvement strategies can be developed and tracked over time. At the time this paper was written, 279 individuals had registered, and 107 had completed the SPA. On average, the SPA required 1.3 hours to complete. The majority of respondents to the questionnaire (56%) completed the SPA with a multidisciplinary group of 4 people on average. Respondents noted that the SPA was easy or very easy to use (70%) and that they would definitely or very probably complete it again (63%). CONCLUSIONS: SPA provides a straightforward means of gauging a clinic's performance in key safety-critical areas and has been evaluated favorably by the first cohort of users. The tool has been qualified by the American Board of Radiology (ABR) as meeting the criteria for Practice Quality Improvement requirements of the ABR Maintenance of Certification Program.


Assuntos
Competência Clínica/normas , Radioterapia (Especialidade)/normas , Humanos , Segurança do Paciente , Melhoria de Qualidade
19.
J Immunol Methods ; 292(1-2): 25-34, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15350509

RESUMO

To determine the time required to repopulate mouse lungs with donor alveolar macrophages following total body irradiation (TBI) and bone marrow transplantation (BMT), C57Bl/6 mice were subjected to TBI with 900 cGy, followed by transplantation of bone marrow cells from mice expressing green fluorescent protein (GFP) in their somatic cells. The mice were euthanized at either 30 (n=5), 60 (n=5) or 90 (n=5) days following BMT. Thirty days following transplantation, 87.8 +/- 3.9% (mean +/- S.E.M.) circulating leukocytes in recipient mice were derived from the donor, as determined by fluorescence activated cell sorting (FACS) analysis for GFP. However, only 46.9 +/- 7.4% of the resident alveolar cells expressed GFP, indicating incomplete repopulation. By day 60 post-transplantation, the percentage of bronchoalveolar lavage fluid (BALF) cells expressing GFP reached 74.5 +/- 2.4%, remaining stable 90 days after transplantation (80.4 +/- 1.9%). We conclude that 60 days after TBI with 900 cGy and bone marrow transplantation, the majority of the lung resident alveolar macrophages is of donor origin. This study provides useful information regarding the time of reconstitution with donor alveolar macrophages in the pulmonary airspaces of recipient mice following marrow transplantation.


Assuntos
Transplante de Medula Óssea , Macrófagos Alveolares/citologia , Irradiação Corporal Total , Transferência Adotiva , Animais , Proteínas de Fluorescência Verde , Proteínas Luminescentes/metabolismo , Camundongos , Camundongos Endogâmicos C57BL , Fatores de Tempo
20.
Int J Radiat Oncol Biol Phys ; 55(5): 1288-93, 2003 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-12654439

RESUMO

PURPOSE: To detail the effect of supplemental beam radiation on prostate brachytherapy-related morbidity. METHODS AND MATERIALS: The 220 patients reported here were a subgroup randomized on two treatment protocols, with a planned total accrual of 1200. Low-risk patients, with Gleason Grade 2-6, prostate-specific antigen (PSA) 4-10 ng/mL, were randomized to implantation with I-125 (144 Gy, TG-43) vs. Pd-103 (125 Gy, NIST-99). Intermediate-risk patients, with Gleason Grade 7 or higher or PSA of 10-20 ng/mL, were randomized to implantation with Pd-103, delivering 90 vs. 115 Gy (NIST-1999), with 44 vs. 20 Gy external beam irradiation (EBRT), respectively. Beam radiation was delivered with a four-field arrangement, designed to cover the prostate and seminal vesicles with a 2-cm margin (reduced to 1.0 cm posteriorly). Treatment-related morbidity was monitored by mailed questionnaires, using standard American Urologic Association (AUA) and Radiation Therapy Oncology Group criteria at 1, 3, 6, 12 and 24 months. Use of alpha-blockers to relieve obstructive symptoms was not controlled for, but was noted at each follow-up time. RESULTS: AUA score increases were highest at 1 month in the patients treated with higher prescription doses of Pd-103 (125 Gy Pd-103 alone or 115 Gy Pd-103 with 20 Gy EBRT), consistent with prior reports. By 6 months, most Pd-103 patients had returned to baseline, whereas I-125 patient scores were still declining. Patients treated with lower dose Pd-103 combined with EBRT had lesser elevations of their AUA scores at 1 and 6 months, but differences between those receiving 20 vs. 44 Gy beam radiation were inconsistent. At no point did beam radiation significantly affect postimplant AUA scores or urinary morbidity scores. Rectal morbidity scores were remarkably similar between groups, apart from higher scores at 1 month in patients treated with full dose Pd-103. Rectal morbidity consisted primarily of increased frequency and mucous passage. There have been no instances of rectal ulceration or fistula. The addition of beam radiation significantly increased postimplant rectal morbidity scores only at the 1-month time point. CONCLUSION: The addition of supplemental beam radiation had little effect on morbidity. We do not believe that morbidity per se should influence the decision of whether or not to use supplemental beam radiation.


Assuntos
Adenocarcinoma/radioterapia , Braquiterapia/efeitos adversos , Neoplasias da Próstata/radioterapia , Lesões por Radiação/prevenção & controle , Radioterapia de Alta Energia/efeitos adversos , Doenças Retais/etiologia , Incontinência Urinária/etiologia , Retenção Urinária/etiologia , Antagonistas Adrenérgicos alfa/uso terapêutico , Idoso , Diarreia/epidemiologia , Diarreia/etiologia , Fracionamento da Dose de Radiação , Seguimentos , Hemorragia/epidemiologia , Hemorragia/etiologia , Humanos , Radioisótopos do Iodo/uso terapêutico , Masculino , Pessoa de Meia-Idade , Paládio/uso terapêutico , Lesões por Radiação/etiologia , Radioisótopos/uso terapêutico , Doenças Retais/epidemiologia , Incontinência Urinária/epidemiologia , Retenção Urinária/tratamento farmacológico , Retenção Urinária/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA