Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Electrophoresis ; 36(3): 428-32, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25043750

RESUMO

We report a simple protocol for fabrication of shape-anchored porous polymer monoliths (PPMs) for on-chip SPE prior to online microchip electrophoresis (ME) separation and on-chip (ESI/MS). The chip design comprises a standard ME separation channel with simple cross injector and a fully integrated ESI emitter featuring coaxial sheath liquid channel. The monolith zone was prepared in situ at the injection cross by laser-initiated photopolymerization through the microchip cover layer. The use of high-power laser allowed not only maskless patterning of a precisely defined monolith zone, but also faster exposure time (here, 7 min) compared with flood exposure UV lamps. The size of the monolith pattern was defined by the diameter of the laser output (∅500 µm) and the porosity was geared toward high through-flow to allow electrokinetic actuation and thus avoid coupling to external pumps. Placing the monolith at the injection cross enabled firm anchoring based on its cross-shape so that no surface premodification with anchoring linkers was needed. In addition, sample loading and subsequent injection (elution) to the separation channel could be performed similar to standard ME setup. As a result, 15- to 23-fold enrichment factors were obtained already at loading (preconcentration) times as short as 25 s without sacrificing the throughput of ME analysis. The performance of the SPE-ME-ESI/MS chip was repeatable within 3.1% and 11.5% RSD (n = 3) in terms of migration time and peak height, respectively, and linear correlation was observed between the loading time and peak area.


Assuntos
Eletroforese em Microchip/instrumentação , Polímeros/química , Extração em Fase Sólida/instrumentação , Espectrometria de Massas por Ionização por Electrospray/instrumentação , Eletroforese em Microchip/métodos , Desenho de Equipamento , Interações Hidrofóbicas e Hidrofílicas , Preparações Farmacêuticas/análise , Preparações Farmacêuticas/isolamento & purificação , Porosidade , Reprodutibilidade dos Testes , Extração em Fase Sólida/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos
2.
J Biomed Mater Res A ; 101(3): 842-52, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22968914

RESUMO

We hypothesized that when compared with conventional two-dimensional (2D) cultures, substrates containing 3D micropillars would allow cells to grow at levels, activating their cytoskeleton to promote osteogenesis. Fibroblasts, osteoblast-like cells, and mesenchymal stem cells (MSCs) were studied. Planar substrates were compared with 200-nm-, 5-µm-, and 20-µm-high pillars of Ormocomp®, Si, diamond-like carbon, or TiO(2). Scanning electron microscopy and staining of actin cytoskeleton showed 7.5-h adhesion to pillar edges and 5-day stretching between adhesion contacts > 100-µm distances of fibroblast and MSC in 3D networks, whereas SaOS-2 cells adhered flatly and individually on horizontal and vertical surfaces. ERK and ROCK immunostaining at 14 and 21 days confirmed activation of the cytoskeleton. In contrast to expectations, success to induce osteogenesis was dominated by the cytocompatibility of the substrate over the 3D structure. This was shown using early alkaline phosphatase, intermediate osteopontin, and late mineralization markers, together with bone nodule formation, which were seen in planar substrates and low-profile TiO(2) pillars, but were poor in the 20-µm landscape. The lack of intercellular contacts seems to halt the osteogenesis-promoting effects of cytoskeletal organization and tension described earlier.


Assuntos
Diferenciação Celular , Fibroblastos/metabolismo , Células-Tronco Mesenquimais/metabolismo , Osteoblastos/metabolismo , Osteogênese , Alicerces Teciduais/química , Titânio/química , Antígenos de Diferenciação/biossíntese , Calcificação Fisiológica , Adesão Celular , Linhagem Celular , Citoesqueleto/metabolismo , Fibroblastos/citologia , Humanos , Células-Tronco Mesenquimais/citologia , Osteoblastos/citologia
3.
J Neurosci Methods ; 212(2): 276-82, 2013 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-23124090

RESUMO

A microfluidic chip for culturing neurons and spatially isolating axons from somas is presented for use with visually guided whole-cell electrophysiological measurements. A modular design consisting of detachable and re-sealable layers is used to satisfy the requirements of both long-term neuron culturing as well as electrophysiological measurements. Whole cell patch clamp recordings indicate functional viability of neurons with isolated axons. Fluidic isolation was used to achieve asymmetric lentiviral infection of neurons on a single side reservoir. Neurons were asymmetrically infected with lentiviruses expressing the light-activated cationic channel channelrhodopsin-2. Light-evoked excitatory postsynaptic responses were detected by whole cell recordings of neurons on the uninfected side showing functional synaptic connectivity between the two isolated but axonally connected sides of the device.


Assuntos
Axônios/fisiologia , Eletrofisiologia/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Animais , Imuno-Histoquímica , Microscopia Confocal , Ratos
4.
Biomicrofluidics ; 6(1): 16501-1650110, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22685510

RESUMO

PLASMA HYDROPHILIZATION AND SUBSEQUENT HYDROPHOBIC RECOVERY ARE STUDIED FOR TEN DIFFERENT POLYMERS OF MICROFABRICATION INTEREST: polydimethylsiloxane (PDMS), polymethylmethacrylate, polycarbonate, polyethylene, polypropylene, polystyrene, epoxy polymer SU-8, hybrid polymer ORMOCOMP, polycaprolactone, and polycaprolactone/D,L-lactide (P(CL/DLLA)). All polymers are treated identically with oxygen and nitrogen plasmas, in order to make comparisons between polymers as easy as possible. The primary measured parameter is the contact angle, which was measured on all polymers for more than 100 days in order to determine the kinetics of the hydrophobic recovery for both dry stored and rewashed samples. Clear differences and trends are observed both between different polymers and between different plasma parameters.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA