Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Sports Health ; 14(1): 111-118, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34693813

RESUMO

BACKGROUND: In young tennis players, high loads on the spine and high training volumes in relation to age are associated with a high lifetime prevalence of back pain. The primary aim of this study was to investigate if accumulated external workload "spikes" in the acute:chronic workload ratio (ACWR) of tennis training, match play, and fitness training, and if high or low workload/age ratio were associated with back pain events in competitive adolescent tennis players. Additional aims were to report the incidence of back pain stratified by sex and level of play and to describe the characteristics of players with back pain. HYPOTHESIS: Rapid increases in external workload are associated with the incidence of back pain. STUDY DESIGN: Cohort study of 198 competitive tennis players, 13 to 19 years, with a weekly follow-up for 52 consecutive weeks. LEVEL OF EVIDENCE: Level 3. METHODS: Accumulated external workload spikes (uncoupled ACWR >1.3), and the workload/age ratio, were time-varying exposures in Cox regression analyses with the outcome back pain (pain intensity ≥2/10 in the lower back and/or in the upper back/neck with a pain-related disability). RESULTS: For each additional workload spike in tennis training/match play, the hazard rate ratio (HRR) was 1.17 (95% CI, 1.06-1.28) for back pain. The corresponding HRR for fitness training was 1.13 (95% CI, 1.05-1.22). Training workload/age ratio was not related to back pain. CONCLUSION: Accumulated external workload spikes of tennis training, match play, and/or fitness training are associated with a higher rate of back pain events in competitive adolescent tennis players. CLINICAL RELEVANCE: Back pain is a troublesome clinical problem that may affect the performance of talented young tennis players. Structuring the training schedule to minimize rapid increases (ie, spikes) of training load on a weekly basis may enhance performance and reduce back pain in adolescent tennis players.


Assuntos
Tênis , Adolescente , Dor nas Costas/epidemiologia , Estudos de Coortes , Humanos , Incidência , Estudos Prospectivos
2.
Acta Radiol ; 52(10): 1128-37, 2011 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-22006984

RESUMO

BACKGROUND: Cervical total disc replacement (CTDR) is an alternative to anterior fusion. Therefore, it is desirable to have an accurate in vivo measurement of prosthetic kinematics and assessment of implant stability relative to the adjacent vertebrae. PURPOSE: To devise an in vivo CT-based method to analyze the kinematics of cervical total disc replacements (CTDR), specifically of two prosthetic components between two CT scans obtained under different conditions. MATERIAL AND METHODS: Nine patients with CTDR were scanned in flexion and extension of the cervical spine using a clinical CT scanner with a routine low-dose protocol. The flexion and extension CT volume data were spatially registered, and the prosthetic kinematics of two prosthetic components, an upper and a lower, was calculated and expressed in Euler angles and orthogonal linear translations relative to the upper component. For accuracy analysis, a cervical spine model incorporating the same disc replacement as used in the patients was also scanned and processed in the same manner. RESULTS: Analysis of both the model and patients showed good repeatability, i.e. within 2 standard deviations of the mean using the 95% limits of agreement with no overlapping confidence intervals. The accuracy analysis showed that the median error was close to zero. CONCLUSION: The mobility of the cervical spine after total disc replacement can be effectively measured in vivo using CT. This method requires an appropriate patient positioning and scan parameters to achieve suitable image quality.


Assuntos
Disco Intervertebral/diagnóstico por imagem , Disco Intervertebral/cirurgia , Modelos Biológicos , Amplitude de Movimento Articular , Tomografia Computadorizada por Raios X/métodos , Substituição Total de Disco , Adulto , Análise de Variância , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Prótese Articular , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Implantação de Prótese , Reprodutibilidade dos Testes
3.
Eur J Epidemiol ; 25(6): 431-7, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20449637

RESUMO

National Longitudinal data of thoracolumbar fracture incidence, trends or mortality rates are lacking. The correlation between admissions and operations of thoracolumbar vertebral fractures has not been investigated. The aim of our nationwide population-based epidemiological study was to analyse the incidence, admissions, operations, and case fatality rate among patients with thoracolumbar vertebral fractures admitted to hospital in Sweden. The Swedish Hospital Discharge Register (SHDR) and the Cause of Death Register (CDR) were linked to determine the incidence of surgical interventions, trends, characteristics of the patients, and case fatality rate for thoracolumbar vertebral fractures based on comprehensive national data. The annual incidence of thoracolumbar fractures was on average 30 per 100,000 inhabitants and did not change considerably during the study period. Among patients younger than 60 years of age the annual incidence was 13 per 100,000 and was twice as high in men compared to women. The proportion operated on was 15%. In the age-group 60 years and older the majority were women. In this group two percent were operated on. However, males were operated on twice as often as women. The 90-day case-fatality rate after surgery was 1.4%. This information may assist health care providers in health care planning. Moreover, these data can also be used for power calculations when planning future clinical studies.


Assuntos
Vértebras Lombares/lesões , Fraturas da Coluna Vertebral/epidemiologia , Vértebras Torácicas/lesões , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Incidência , Lactente , Recém-Nascido , Estudos Longitudinais , Vértebras Lombares/cirurgia , Masculino , Pessoa de Meia-Idade , Admissão do Paciente/estatística & dados numéricos , Fraturas da Coluna Vertebral/etiologia , Fraturas da Coluna Vertebral/cirurgia , Análise de Sobrevida , Suécia/epidemiologia , Vértebras Torácicas/cirurgia , Adulto Jovem
4.
Clin Spine Surg ; 31(8): E397-E402, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29939843

RESUMO

STUDY DESIGN: This was a randomized radiologic biomechanical pilot study in vivo. OBJECTIVE: The objectives of this study was to evaluate if 3-dimensional computed tomography is a feasible tool in motion analyses of the lumbar spine and to study if preservation of segmental midline structures offers less postoperative instability compared with central decompression in patients with lumbar spinal stenosis with degenerative spondylolisthesis. SUMMARY OF BACKGROUND DATA: The role of segmental instability after decompression is controversial. Validated techniques for biomechanical evaluation of segmental motion in human live subjects are lacking. METHODS: In total, 23 patients (mean age, 68 y) with typical symptoms and magnetic resonance imaging findings of spinal stenosis with degenerative spondylolisthesis (>3 mm) in 1 or 2 adjacent lumbar levels from L3 to L5 were included. They were randomized to either laminectomy (LE) or bilateral laminotomy (LT) (preservation of the midline structures). Documentation of segmental motion was made preoperatively and 6 months postoperatively with CT in provoked flexion and extension. Analyses of movements were performed with validated software. The accuracy for this method is 0.6 mm in translation and 1 degree in rotation. Patient-reported outcome measures were collected from the Swespine register preoperatively and 2-year postoperatively. RESULTS: The mean preoperative values for 3D rotation and translation were 6.2 degrees and 1.8 mm. The mean increase in 3D rotation 6 months after surgery was 0.25 degrees after LT and 0.7 degrees after LE (P=0.79) while the mean increase in 3D translation was 0.15 mm after LT and 1.1 mm after LE (P=0.42). Both surgeries demonstrated significant improvement in patient-reported outcome measures 2 years postoperatively. CONCLUSIONS: The 3D computed tomography technique proved to be a feasible tool in the evaluation of segmental motion in this group of older patients. There was negligible increase in segmental motion after decompressive surgery. LE with removal of the midline structures did not create a greater instability compared with when these structures were preserved.


Assuntos
Imageamento Tridimensional , Laminectomia , Vértebras Lombares/cirurgia , Movimento (Física) , Estenose Espinal/diagnóstico por imagem , Estenose Espinal/cirurgia , Espondilolistese/cirurgia , Tomografia Computadorizada por Raios X , Idoso , Estudos de Viabilidade , Humanos , Vértebras Lombares/diagnóstico por imagem , Pessoa de Meia-Idade , Medidas de Resultados Relatados pelo Paciente , Projetos Piloto , Estenose Espinal/complicações , Espondilolistese/complicações , Espondilolistese/diagnóstico por imagem
5.
J Neurosurg Spine ; 23(3): 383-9, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26047344

RESUMO

OBJECT: Artificial disc replacement (ADR) devices are unlike implants used in cervical fusion in that they are continuously exposed to stress not only within the implant site but also at their site of attachment to the adjacent vertebra. An imaging technique with higher accuracy than plain radiography and with the possibility of 3D visualization would provide more detailed information about the motion quality and stability of the implant in relation to the vertebrae. Such high-accuracy studies have previously been conducted with radiostereometric analysis (RSA), which requires implantation of tantalum markers in the adjacent vertebrae. The aim of this study was to evaluate in vivo motion and stability of implanted artificial discs. A noninvasive analysis was performed with CT, with an accuracy higher than that of plain radiographs and almost as high as RSA in cervical spine. METHODS: Twenty-eight patients with ADR were included from a larger cohort of a randomized controlled trial comparing treatment of cervical radiculopathy with ADR or anterior cervical decompression and fusion. Surgical levels included C4-7; 18 patients had 1-level surgery and 10 patients had 2-level surgery. Follow-up time ranged from 19 to 50 months, with an average of 40 months. Two CT volumes of the cervical spine, 1 in flexion and 1 in extension, were obtained in each patient and then spatially registered using a customized imaging tool, previously used and validated for the cervical spine. Motion between the components in the artificial disc, as well as motion between the components and adjacent vertebrae, were calculated in 3 planes. Intraclass correlation (ICC) between independent observers and repeatability of the method were also calculated. RESULTS: Intrinsic motion, expressed as degrees in rotation and millimeters in translation, was detectable in a majority of the ADRs. In the sagittal plane, in which the flexion/extension was performed, sagittal rotation ranged between 0.2° and 15.8° and translation between 0.0 and 5.5 mm. Eight percent of the ADRs were classified as unstable, as motion between at least 1 of the components and the adjacent vertebra was detected. Five percent were classified as ankylotic, with no detectable motion, and another 8% showed very limited motion due to heterotopic ossification. Repeatability for the motion in the sagittal plane was calculated to be 1.30° for rotation and 1.29 mm for translation (95% confidence level), ICC 0.99 and 0.84, respectively. All 3 patients with unstable devices had undergone 1-level ADRs at C5-6. They all underwent revision surgery due to increased neck pain, and instability was established during the surgery. CONCLUSIONS: The majority of the artificial discs in this study showed intrinsic mobility several years after implantation and were also shown to be properly attached. Implant instability was detected in 8% of patients and, as all of these patients underwent revision surgery due to increasing neck pain, this might be a more serious problem than heterotopic bone formation.


Assuntos
Degeneração do Disco Intervertebral/cirurgia , Disco Intervertebral/cirurgia , Próteses e Implantes , Amplitude de Movimento Articular/fisiologia , Substituição Total de Disco , Adulto , Fenômenos Biomecânicos/fisiologia , Feminino , Humanos , Disco Intervertebral/fisiopatologia , Degeneração do Disco Intervertebral/fisiopatologia , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
6.
Biomed Res Int ; 2015: 260703, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26587533

RESUMO

This study describes a 3D-CT method for analyzing facet joint motion and vertebral rotation in the lumbar spine after TDR. Ten patients were examined before and then three years after surgery, each time with two CT scans: provoked flexion and provoked extension. After 3D registration, the facet joint 3D translation and segmental vertebral 3D rotation were analyzed at the operated level (L5-S1) and adjacent level (L4-L5). Pain was evaluated using VAS. The median (±SD) 3D movement in the operated level for the left facet joint was 3.2 mm (±1.9 mm) before and 3.5 mm (±1.7 mm) after surgery and for the right facet joint was 3.0 mm (±1.0 mm) before and 3.6 mm (±1.4 mm) after surgery. The median vertebral rotation in the sagittal plane at the operated level was 5.4° (±2.3°) before surgery and 6.8° (±1.7°) after surgery and in the adjacent level was 7.7° (±4.0°) before and 9.2° (±2.7°) after surgery. The median VAS was reduced from 6 (range 5-8) to 3 (range 2-8) in extension and from 4 (range 2-6) to 2 (range 1-3) in flexion.


Assuntos
Dor Crônica , Degeneração do Disco Intervertebral , Dor Lombar , Vértebras Lombares , Movimento , Tomografia Computadorizada por Raios X/métodos , Substituição Total de Disco , Adulto , Dor Crônica/diagnóstico por imagem , Dor Crônica/fisiopatologia , Dor Crônica/cirurgia , Feminino , Seguimentos , Humanos , Degeneração do Disco Intervertebral/diagnóstico por imagem , Degeneração do Disco Intervertebral/fisiopatologia , Degeneração do Disco Intervertebral/cirurgia , Dor Lombar/diagnóstico por imagem , Dor Lombar/fisiopatologia , Dor Lombar/cirurgia , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/fisiopatologia , Vértebras Lombares/cirurgia , Masculino , Pessoa de Meia-Idade
7.
Acta Orthop Scand ; 73(4): 407-8, 2002 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12358113

RESUMO

We used the Hardinger occluder plug in 51 consecutive total hip arthroplasties. In 34 hips, 1 or more of the 12 polyethylene wings fractured and could be washed out from the canal. As many as 7 wings were loose in 2 arthroplasties. Although numerous wings were broken, no failure occurred in occlusion. The placement of loose wings in the femoral canal was studied by cementing a Charnley prosthesis in a saw-bone prepared with loose wings. The model was cut into slices. We found that the plastic wings could come into contact with both the bone and prosthesis.


Assuntos
Prótese de Quadril , Falha de Prótese , Humanos , Osteoartrite do Quadril/cirurgia , Polietilenos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA