Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Pharmacokinet Pharmacodyn ; 43(3): 315-24, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27221375

RESUMO

The purpose of this study was to assess the pharmacokinetics of dexmedetomidine in the ICU settings during the prolonged infusion and to compare it with the existing literature data using the Bayesian population modeling with literature-based informative priors. Thirty-eight patients were included in the analysis with concentration measurements obtained at two occasions: first from 0 to 24 h after infusion initiation and second from 0 to 8 h after infusion end. Data analysis was conducted using WinBUGS software. The prior information on dexmedetomidine pharmacokinetics was elicited from the literature study pooling results from a relatively large group of 95 children. A two compartment PK model, with allometrically scaled parameters, maturation of clearance and t-student residual distribution on a log-scale was used to describe the data. The incorporation of time-dependent (different between two occasions) PK parameters improved the model. It was observed that volume of distribution is 1.5-fold higher during the second occasion. There was also an evidence of increased (1.3-fold) clearance for the second occasion with posterior probability equal to 62 %. This work demonstrated the usefulness of Bayesian modeling with informative priors in analyzing pharmacokinetic data and comparing it with existing literature knowledge.


Assuntos
Teorema de Bayes , Dexmedetomidina/administração & dosagem , Dexmedetomidina/farmacocinética , Hipnóticos e Sedativos/administração & dosagem , Hipnóticos e Sedativos/farmacocinética , Modelos Biológicos , Algoritmos , Criança , Pré-Escolar , Estado Terminal , Dexmedetomidina/sangue , Dexmedetomidina/uso terapêutico , Relação Dose-Resposta a Droga , Feminino , Humanos , Hipnóticos e Sedativos/sangue , Hipnóticos e Sedativos/uso terapêutico , Lactente , Infusões Intravenosas , Masculino , Software , Fatores de Tempo
2.
Biomed Chromatogr ; 28(6): 802-9, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24861747

RESUMO

The aim of the study was to develop and validate a simple and rapid method for the determination of cyclosporine A (CsA) in ocular rabbit tissues using reversed-phase ultra-high-performance liquid chromatography (UHPLC) with UV detection. Previous publications on chromatographic methods of CsA determination in ocular tissues involved only reversed-phase HPLC separation, usually in combination with such detection techniques as radio-immunoassay and mass spectrometry. The application of the UHPLC technique allowed us to significantly decrease the analysis time. Cyclosporine D (CsD) was applied as the internal standard. Satisfactory separation was achieved on an XB-C18 Kinetex column at 60°C with the use of gradient elution mode. The retention times of CsA and CsD were found to be 4.5 and 5.1 min, respectively. The developed assay is specific, sensitive (limit of detection = 6 ng/mL and limit of quantitation = 18 ng/mL) and linear within the analyte concentration range of 0.018-5 µg/mL, with a correlation coefficient of 0.999. High sensitivity, low injection volume (10 µL), short time of analysis (6.5 min) and simplicity make this method useful for the fast analysis of CsA in rabbit ocular tissues and fluids: lacrimal fluid, aqueous humor, cornea, conjunctiva and eye globe.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Ciclosporina/análise , Imunossupressores/análise , Animais , Humor Aquoso/química , Cromatografia de Fase Reversa/métodos , Olho/química , Aparelho Lacrimal/química , Masculino , Coelhos
3.
Pharmaceuticals (Basel) ; 16(12)2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-38139839

RESUMO

Among the currently available commercial eye drops with cyclosporine A (Cs) there is a lack of long-acting dosage forms and products with a concentration of the drug substance higher than 0.1%, although Cs is widely used in ophthalmology. The aim of the research was to conduct the microscopic and biopharmaceutical evaluation of two formulations, an emulsion (EM) and a self-emulsifying oil (SEO), both with 0.5% of Cs, proposed for use in eye drops, and the comparison of both. SEO eye drops with Cs or any other drug substance are currently not available as marketed products, and the highest concentration of Cs in the ocular emulsion is only 0.1%. The microscopic evaluation of the emulsion and the SEO after emulsification with water was carried out using a high-resolution digital microscopy. The properties of both preparations were compared using the high dynamic range function or optical shadow effect mode. Images in the 3D composition mode were also recorded. The in vivo study of the Cs formulations was performed on male albino rabbits. The eye tolerance of the preparations was assessed using the ocular irritation test, which is a modified Draize test. Placebo carriers (without the drug substance) were also subjected to irritation testing. The concentration of Cs in the tissues (cornea and conjunctiva) and fluids (tear fluid and aqueous humor) of the rabbit eye was determined after multiple instillations of Cs-EM or Cs-SEO. The tested preparations were compared using the digital microscopy technique, which highlights the features of the formulations and eliminates the risk of unnoticeable properties that are difficult to observe in classical optical microscopy. Both tested Cs-loaded formulations are classified as practically non-irritating. There were also no significant differences when testing the placebo carriers. After a topical administration, Cs was widely distributed in all tissues (e.g., in cornea 1.3 ng/mg and 1.0 ng/mg) and fluids of the eye (e.g., in tear fluid 11.6 µg/mL and 4.3 µg/mL), after the administration of Cs-SEO and Cs-EM, respectively. The obtained results allow us to recognize both tested formulations, the emulsion and the self-emulsifying oil with 0.5% Cs content, as carriers safe for ophthalmic use and effective in delivering the drug substance to the structures of the eye.

4.
Eur J Pharm Sci ; 121: 95-105, 2018 08 30.
Artigo em Inglês | MEDLINE | ID: mdl-29777856

RESUMO

The aim of this study was to investigate the in vivo effect of Solid Lipid Microparticles (SLM), proposed for topical ocular administration of cyclosporine, on the rabbit eye. SLM carrier is an aqueous dispersion of lipid microparticles (20% w/w) with a size up to 15 µm. Cyclosporine was dissolved in the formulation in the concentration of 0.5 or 2.0% (w/w). Ocular tolerance of microsphere dispersion was assessed in rabbit model by the Draize eye test (SLM was compared with emulsion and oily solution), and cyclosporine distribution in ocular tissues was evaluated after multiple application of tested formulations (SLM dispersions, emulsions and oily solution) for 7 days. Good tolerance of cyclosporine-SLM formulation was demonstrated in the rabbit model. Concentration of cyclosporine in the precorneal tissues, such as cornea and conjunctiva, was much higher than the therapeutic value (8.4 ng/mg and 3.2 ng/mg, respectively). After SLM administration, the cyclosporine concentrations determined in the anterior ocular tissues, were also significantly higher compared to those obtained after the application of other tested carriers (emulsions and oily solution). The obtained results prove that the recognized SLM dispersions are safe formulations for ophthalmic use. It can be concluded that lipid microparticles are highly promising for an efficient ophthalmic drug delivery, when compared to other conventional dosage forms.


Assuntos
Ciclosporina/administração & dosagem , Portadores de Fármacos/administração & dosagem , Olho/efeitos dos fármacos , Imunossupressores/administração & dosagem , Microesferas , Animais , Ciclosporina/química , Ciclosporina/farmacocinética , Ciclosporina/toxicidade , Portadores de Fármacos/química , Portadores de Fármacos/farmacocinética , Portadores de Fármacos/toxicidade , Liberação Controlada de Fármacos , Olho/metabolismo , Imunossupressores/química , Imunossupressores/farmacocinética , Imunossupressores/toxicidade , Lipídeos/administração & dosagem , Lipídeos/química , Lipídeos/farmacocinética , Lipídeos/toxicidade , Masculino , Coelhos , Testes de Toxicidade Aguda
5.
Anal Chim Acta ; 1037: 188-199, 2018 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-30292293

RESUMO

Bladder cancer constitutes the ninth most common cancer worldwide and, despite continuous development of new diagnostic approaches, the thirteenth leading cause of global cancer mortality. In our previous untargeted urine metabolomic investigation, seventeen metabolites were found to be statistically differentiating bladder cancer patients and healthy volunteers. Therefore, the main goal of this study was to develop and validate an analytical method for simultaneous quantitative determination of those metabolites using reversed phase high-performance liquid chromatography coupled with triple quadrupole mass spectrometry technique (RP-HPLC-QQQ/MS). Different chromatographic conditions, as well as various sample treatment procedures were tested in order to provide the best separation and the lowest limit of quantification (LOQ) values for studied compounds. The validation was performed according to the Food and Drug Administration guidelines (FDA). The limit of determination (LOD) and the LOQ values were in the range of 0.21-10.51 ng/ml and 0.69-35.02 ng/ml, respectively. The concentration range of compounds was developed between 2.5 and 12500 ng/ml. Only one compound (trimethyllysine) showed a significant matrix effect (61%) and consequently low process efficiency (64%). Overall, developed method presented recovery and precision values within the ranges proposed by FDA guidelines. The optimized and validated method was applied to urine samples obtained from 40 patients with bladder cancer and 40 healthy volunteers matched according to ones of the most important risk factors for developing urinary bladder tumors, e.i. age, gender and BMI. Afterwards, statistical analysis was provided by the use of Student's t-test or U-Mann Whitney test. The developed method was sensitive, selective and reproducible to be applied for the quantification of metabolites in the investigation of urine samples. As a consequence, ten out of previously chosen seventeen compounds, participating in different metabolites' pathways (gut floral metabolism, RNA degradation, purine metabolism, etc.), were found to be statistically significantly different in the urine concentration (p < 0.05) between cancer and control groups.


Assuntos
Metabolômica , Neoplasias da Bexiga Urinária/metabolismo , Idoso , Idoso de 80 Anos ou mais , Cromatografia Líquida de Alta Pressão , Feminino , Humanos , Masculino , Espectrometria de Massas , Pessoa de Meia-Idade , Espectrofotometria Ultravioleta , Neoplasias da Bexiga Urinária/diagnóstico , Neoplasias da Bexiga Urinária/urina
6.
Bioanalysis ; 9(4): 395-406, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28105858

RESUMO

AIM: The purpose of this work was to develop and validate a rapid and robust LC-MS/MS method for the determination of dexmedetomidine (DEX) in plasma, suitable for analysis of a large number of samples. METHOD: Systematic approach, Design of Experiments, was applied to optimize ESI source parameters and to evaluate method robustness, therefore, a rapid, stable and cost-effective assay was developed. The method was validated according to US FDA guidelines. LLOQ was determined at 5 pg/ml. The assay was linear over the examined concentration range (5-2500 pg/ml), Results: Experimental design approach was applied for optimization of ESI source parameters and evaluation of method robustness. The method was validated according to the US FDA guidelines. LLOQ was determined at 5 pg/ml. The assay was linear over the examined concentration range (R2 > 0.98). The accuracies, intra- and interday precisions were less than 15%. The stability data confirmed reliable behavior of DEX under tested conditions. CONCLUSION: Application of Design of Experiments approach allowed for fast and efficient analytical method development and validation as well as for reduced usage of chemicals necessary for regular method optimization. The proposed technique was applied to determination of DEX pharmacokinetics in pediatric patients undergoing long-term sedation in the intensive care unit.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Dexmedetomidina/sangue , Dexmedetomidina/farmacocinética , Espectrometria de Massas em Tandem/métodos , Calibragem , Criança , Análise Custo-Benefício , Cuidados Críticos , Humanos , Limite de Detecção , Modelos Lineares , Pediatria , Controle de Qualidade , Reprodutibilidade dos Testes , Projetos de Pesquisa , Espectrometria de Massas por Ionização por Electrospray , Estados Unidos , United States Food and Drug Administration
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA