Pacing Clin Electrophysiol ; 47(7): 893-901, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38884620

RESUMO

BACKGROUND: To preserve the benefit of atrial sensing without the implantation of an additional lead, a single-lead ICD system with a floating atrial dipole (DX ICD) has been developed. The purpose of this nationwide survey was to provide an overview of the current key influences of device selection focusing on DX ICD and to test the applicability of a previously published decision-making flowchart of ICD-type selection. METHODS: An online questionnaire was sent to all implanting centers in Hungary. Eleven centers reported data from 361 DX ICD and 10 CRT-DX systems implantations between February 2021 and May 2023. RESULTS: The most important influencing clinical factors indicated by the participating doctors were elevated risk of atrial fibrillation (AF)/stroke (56%), risk of sinus/supraventricular tachycardias (SVT) (42%), and a potential need for CRT upgrade in the future (36%). The DX ICD was considered in the majority of cases instead of the VVI system (87%), and only in a small proportion instead of a DDD ICD (13%). 60% of the patients with DX ICDs were also included into remote monitoring-based follow-up. In 83% of the cases, good (>2 mV) or excellent (>5) atrial signal amplitude was recorded within 6 weeks after the implantation. CONCLUSION: In the current national survey, the most important influencing factors indicated by the implanters for selecting a DX ICD were the elevated risk of stroke or sinus/SVT and a potential need for CRT upgrade in the future. These findings support the use of a previously published decision-making flowchart.


Assuntos
Desfibriladores Implantáveis , Humanos , Estudos Prospectivos , Inquéritos e Questionários , Masculino , Feminino , Hungria , Fibrilação Atrial , Idoso , Pessoa de Meia-Idade
2.
J Cardiovasc Electrophysiol ; 34(12): 2472-2483, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37767745

RESUMO

INTRODUCTION: Pulmonary vein isolation (PVI) is a pivotal part of ablative therapy for atrial fibrillation (AF). Currently, there are multiple techniques available to realize PVI, including: manual-guided cryoballoon (MAN-CB), manual-guided radiofrequency (MAN-RF), and robotic magnetic navigation-guided radiofrequency ablation (RMN-RF). There is a lack of large prospective trials comparing contemporary RMN-RF with the more conventional ablation techniques. This study prospectively compared three catheter ablation techniques as treatment of paroxysmal AF. METHODS: This multicenter, prospective study included patients with paroxysmal AF who underwent their first ablation procedure. Procedural parameters (including procedural efficiency), complication rates, and freedom of AF during 12-month follow-up, were compared between three study groups which were defined by the utilized ablation technique. RESULTS: A total of 221 patients were included in this study. Total procedure time was significantly shorter in MAN-CB (78 ± 21 min) compared to MAN-RF (115 ± 41 min; p < .001) and compared to RMN-RF (129 ± 32 min; p < .001), whereas it was comparable between the two radiofrequency (RF) groups (p = .062). A 3% complication rate was observed, which was comparable between all groups. At 12-month follow-up, AF recurrence was observed in 40 patients (19%) and was significantly lower in the robotic group (MAN-CB 19 [24%], MAN-RF 16 [23%], RMN-RF 5 [8%] AF recurrences, p = .045) (multivariate hazard ratio of RMN-RF on AF recurrence 0.32, 95% confidence interval: 0.12-0.87, p = .026). CONCLUSION: RMN-guided PVI results in high freedom of AF in patients with paroxysmal AF, when compared to cryoablation and manual RF ablation. Cryoablation remains the most time-efficient ablation technique, whereas RMN nowadays has comparable efficiency with manual RF ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Procedimentos Cirúrgicos Robóticos , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Fenômenos Magnéticos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
3.
Europace ; 25(1): 74-82, 2023 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-36056882

RESUMO

AIMS: REDO-FIRM evaluated safety and effectiveness of conventional vs. focal impulse and rotor modulation (FIRM)-guided ablation of recurrent persistent or paroxysmal atrial fibrillation (AF) after an initial AF ablation procedure. METHODS AND RESULTS: This prospective, multicentre, randomized study included patients with a single prior AF ablation, but with recurrent AF and reconnected pulmonary veins (PVs). Conventional ablation generally included PV re-isolation; however, additional ablation was permitted per physician discretion. In the FIRM arm, beyond PV re-isolation, basket catheter-based FIRM mapping created dynamic animations of putative rotors, which were targeted for ablation. Between May 2016 and July 2019, 269 subjects were randomized, with 243 subjects completing 12-month follow-up. Ablation beyond re-pulmonary vein isolation, the FIRM vs. Conventional arms did not differ significantly: cavo-tricuspid isthmus -9.0% vs. 15.3%, caval vein isolation -1.5% vs. 0.8%, non-PV trigger -2.2% vs. 3.8%, other -11.9% vs. 13.0%. Single procedure 12-month freedom from AF/atrial tachycardia/atrial flutter-recurrence was 63.3% (76/120) vs. 59.0% (72/122) in the FIRM and Conventional arms (P = 0.3503). Efficacy was similar in the paroxysmal and persistent AF subgroups (P = 0.22 and P = 0.48). The 10-day and 12-month safety endpoints were achieved in 93.3% vs. 93.8% (P = 0.89) and 88.4% vs. 93.4% (P = 0.22) in the FIRM and Conventional arms, respectively. CONCLUSIONS: In REDO-FIRM, as compared to standard ablation, FIRM-guided ablation did not provide additional efficacy in redo ablation procedures, but FIRM-guided ablation was equally safe. Additional studies are necessary to identify any potential population able to benefit from FIRM-guided ablation.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Estudos Prospectivos , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
4.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37072340

RESUMO

AIMS: RECOVER AF evaluated the performance of whole-chamber non-contact charge-density mapping to guide the ablation of non-pulmonary vein (PV) targets in persistent atrial fibrillation (AF) patients following either a first or second failed procedure. METHODS AND RESULTS: RECOVER AF was a prospective, non-randomized trial that enrolled patients scheduled for a first or second ablation retreatment for recurrent AF. The PVs were assessed and re-isolated if necessary. The AF maps were used to guide the ablation of non-PV targets through elimination of pathologic conduction patterns (PCPs). Primary endpoint was freedom from AF on or off antiarrhythmic drugs (AADs) at 12 months. Patients undergoing retreatment with the AcQMap System (n = 103) were 76% AF-free at 12 months [67% after single procedure (SP)] on or off AADs (80% free from AF on AADs). Patients who had only received a pulmonary vein isolation (PVI) prior to study treatment of non-PV targets with the AcQMap System were 91% AF-free at 12 months (83% SP). No major adverse events were reported. CONCLUSION: Non-contact mapping can be used to target and guide the ablation of PCPs beyond the PVs in persistent AF patients returning for a first or second retreatment with 76% freedom from AF at 12 months. The AF freedom was particularly high, 91% (43/47), for patients enrolled having only a prior de novo PVI, and freedom from all atrial arrhythmias for this cohort was 74% (35/47). These early results are encouraging and suggest that guiding individualized targeted ablation of PCPs may therefore be advantageous to target at the earliest opportunity in patients with persistent AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Estudos Prospectivos , Veias Pulmonares/cirurgia , Retratamento , Antiarrítmicos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento , Recidiva
5.
Pacing Clin Electrophysiol ; 46(7): 771-781, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37260105

RESUMO

BACKGROUND: Catheter ablation (CA) remains challenging due to suboptimal success rates in persistent atrial fibrillation (AF). Existing mapping technologies cannot reliably distinguish sources in this patient population. Recently, the novel electrographic flow (EGF) mapping system was developed using a modified Horn-Schunk optical flow algorithm to detect and quantify patterns of electrical wavefront propagation in the atria. OBJECTIVES: To test the hypothesis that targeted source ablation based on EGF mapping is superior to empiric AF ablation. METHODS: We included all consecutive patients undergoing EGF guided ablation for persistent AF. All patients underwent pulmonary vein isolation (PVI) and were treated with the same EAM system (CARTO). The outcome of PVI+EGF guided CA was compared with data of PVI-only procedures (PVI-only group) and PVI plus additional empiric adjunctive linear and substrate ablations (PVI+LINES group). 12-months outcome as freedom from AF and atrial tachycardia/flutter (AT/AFL), procedural safety and efficiency characterized by procedure duration, fluoroscopy use, radiofrequency applications and duration, were analyzed. Both intention-to-treat and per protocol analysis were conducted. RESULTS: A total number of 70 patients (39 in PVI+EGF, 16 in PVI-only and 15 patients in PVI+LINES group) were enrolled. Intention-to-treat analysis showed fewer AF recurrences in PVI+EGF as compared with the PVI-only or PVI+LINES groups at 12 months (25.6% vs. 62.5% vs. 53.3%, p = .02). There were no differences in AT/AFL recurrence (17.9% vs. 37.5% vs. 20.0%, p = .37). Procedure times were longer in PVI+EGF group (p < .01), and there were no differences in fluoroscopy use (p = .67). CONCLUSION: Our data suggest that patients treated with EGF-guided CA developed fewer AF recurrences. Although the procedure times are longer, it seems to be safe and offers a more targeted, patient-specific ablation strategy beyond PVI than adjunctive empiric lines and substrate ablation in this complex group of patients.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Taquicardia Supraventricular , Humanos , Fator de Crescimento Epidérmico , Resultado do Tratamento , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Recidiva
6.
Cardiovasc Diabetol ; 21(1): 111, 2022 06 18.
Artigo em Inglês | MEDLINE | ID: mdl-35717188

RESUMO

BACKGROUND: Type 2 diabetes is increasing worldwide. Traditionally, only hypertriglyceridemia is considered a risk factor. We investigated whether also normal triglycerides prospectively associate with incident type 2 diabetes in healthy subjects. METHODS: Incident type 2 diabetes was determined in healthy individuals with normal triglyceride levels from a prospective longitudinal cohort study (PREVEND, n = 2085, 11.4-year median follow-up). RESULTS: Type 2 diabetes incidence was 3.8%. In linear regression analysis baseline insulin, HOMA-IR, total cholesterol, HDL cholesterol, eGFR, systolic blood pressure (all p < 0.001), glucose, age and creatinine (all p < 0.01) independently associated with triglycerides within the normal range, comparable to what would be expected from associations with increased triglycerides. In Kaplan-Meier analysis sex-stratified tertiles of normal triglycerides prospectively associated with de novo type 2 diabetes (p < 0.001). Cox regression confirmed a significant prospective association independent of HOMA-IR [HR (95% CI), 1.39 (1.12, 1.74), p = 0.002] and several other recognized risk factors. CONCLUSIONS: Even in healthy subjects without metabolic syndrome increasing triglyceride levels within the normal range confer a continuous increase in type 2 diabetes incidence. These data indicate that virtually everyone could potentially benefit from triglyceride lowering, further encouraging implementation of lifestyle changes in the general population.


Assuntos
Diabetes Mellitus Tipo 2 , Hiperlipidemias , Hipertrigliceridemia , Resistência à Insulina , Glicemia/metabolismo , HDL-Colesterol , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/epidemiologia , Jejum , Humanos , Estudos Longitudinais , Fatores de Risco , Triglicerídeos
7.
Cardiovasc Diabetol ; 21(1): 41, 2022 03 16.
Artigo em Inglês | MEDLINE | ID: mdl-35296331

RESUMO

BACKGROUND: New onset diabetes after transplantation (NODAT) is a frequent and serious complication of renal transplantation resulting in worse graft and patient outcomes. The pathophysiology of NODAT is incompletely understood, and no prospective biomarkers have been established to predict NODAT risk in renal transplant recipients (RTR). The present work aimed to determine whether remnant lipoprotein (RLP) cholesterol could serve as such a biomarker that would also provide a novel target for therapeutic intervention. METHODS: This longitudinal cohort study included 480 RTR free of diabetes at baseline. 53 patients (11%) were diagnosed with NODAT during a median [interquartile range, IQR] follow-up of 5.2 [4.1-5.8] years. RLP cholesterol was calculated by subtracting HDL and LDL cholesterol from total cholesterol values (all directly measured). RESULTS: Baseline remnant cholesterol values were significantly higher in RTR who subsequently developed NODAT (0.9 [0.5-1.2] mmol/L vs. 0.6 [0.4-0.9] mmol/L, p = 0.001). Kaplan-Meier analysis showed that higher RLP cholesterol values were associated with an increased risk of incident NODAT (log rank test, p < 0.001). Cox regression demonstrated a significant longitudinal association between baseline RLP cholesterol levels and NODAT (HR, 2.27 [1.64-3.14] per 1 SD increase, p < 0.001) that remained after adjusting for plasma glucose and HbA1c (p = 0.002), HDL and LDL cholesterol (p = 0.008) and use of immunosuppressive medication (p < 0.001), among others. Adding baseline remnant cholesterol to the Framingham Diabetes Risk Score significantly improved NODAT prediction (change in C-statistic, p = 0.01). CONCLUSIONS: This study demonstrates that baseline RLP cholesterol levels strongly associate with incident NODAT independent of several other recognized risk factors.


Assuntos
Diabetes Mellitus , Transplante de Rim , Bancos de Espécimes Biológicos , Colesterol , LDL-Colesterol , Estudos de Coortes , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Humanos , Transplante de Rim/efeitos adversos , Lipoproteínas , Estudos Longitudinais , Estudos Prospectivos , Fatores de Risco
8.
Ann Noninvasive Electrocardiol ; 27(3): e12960, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35481956

RESUMO

BACKGROUND: Insertable cardiac monitors (ICMs) are increasingly used to evaluate the atrial fibrillation (AF) burden after catheter ablation of AF. BioMonitor III (BM3) is an ICM with a long sensing vector, which enhances sensing capabilities. The AF detection algorithm of the BM3 is based on R-R interval variability. OBJECTIVE: To evaluate the performance of the AF detection algorithm of BM3 in patients before and after catheter ablation of AF using simultaneous Holter recordings. METHODS: In this prospective study, we enrolled patients scheduled for catheter ablation of paroxysmal or persistent AF. After BM3 implantation, patients had a 4 days Holter registration before and 3 months after ablation. All true AF episodes ≥2 min on the Holter were annotated and matched with BM3 detected AF detections. RESULTS: Thirty-one patients were enrolled (mean age 60 ± 8, 74% male, 68% paroxysmal AF). Fifty-six Holter registrations were performed in 30 patients. Twelve patients demonstrated at least one true AF episode with a total AF duration of 570 h. The AF burden accuracy of BM3 before catheter ablation was 99.6%, with a duration sensitivity of 98.6% and a duration specificity of 99.9%. The AF burden accuracy of BM3 after catheter ablation was 99.8%, with a duration sensitivity of 90.2% and a duration specificity of 99.9%. Overall, the AF burden detected on the Holter and BM3 demonstrated a high Pearson correlation coefficient of 0.996. CONCLUSION: BM3 accurately detects AF burden in patients before and after catheter ablation of AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Eletrocardiografia , Eletrocardiografia Ambulatorial/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
9.
Pediatr Cardiol ; 43(8): 1695-1703, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35486130

RESUMO

Catheter ablation (CA) is an important treatment option for ventricular arrhythmias (VA) in pediatric cardiology. Currently, various CA techniques are available, including remote magnetic navigation (RMN)-guided radiofrequency (RF) ablation. However, no studies evaluate RMN-guided ablative therapy outcomes in children with VA yet. This study aimed to compare procedural and long-term outcomes between RMN-guided and manual (MAN)-guided VA ablation in children. This single-center, retrospective study included all CA procedures for VA performed in children with or without structural heart disease from 2008 until 2020. Two study groups were defined by CA technique: RMN or MAN. Primary outcome was recurrence of VA. Baseline clinical, procedural and safety data were also evaluated. This study included 22 patients, who underwent 30 procedures, with a median age of 15 (IQR 14-17; range 1-17) years and a mean weight of 57 ± 20 kg. In total, 14 procedures were performed using RMN and 16 using MAN (22 first and 8 redo procedures). Regarding first procedures, recurrence rates were significantly lower in RMN compared to MAN (20% versus 67%, P = 0.029), at a mean follow-up of 5.2 ± 3.0 years. Moreover, fluoroscopy dosages were significantly lower in RMN compared to MAN [20 (IQR 14-54) versus 48 (IQR 38-62) mGy, P = 0.043]. In total, 20 patients (91%) were free of VA following their final ablation procedure. This is the first study to investigate the use of RMN in pediatric VA ablation. RMN showed improved outcomes compared to MAN, resulting in lower VA recurrence and reduced fluoroscopy exposure.


Assuntos
Ablação por Cateter , Cirurgia Assistida por Computador , Humanos , Criança , Estudos Retrospectivos , Cirurgia Assistida por Computador/métodos , Resultado do Tratamento , Ablação por Cateter/métodos , Magnetismo/métodos , Arritmias Cardíacas , Fenômenos Magnéticos
10.
J Cardiovasc Electrophysiol ; 32(9): 2424-2431, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34289198

RESUMO

INTRODUCTION: In May 2020, a novel cryoballoon system (POLARx; Boston Scientific) became available for catheter ablation of atrial fibrillation (AF). The design of the cryoballoon is comparable to the Arctic Front Advance Pro (AFA-Pro; Medtronic), but it is more compliant during freezing. We compared the procedural efficacy, biophysical parameters, and risk of phrenic nerve palsy (PNP) between the two cryoballoons. METHODS: Embase, MEDLINE, Web of Science, Cochrane, and Google Scholar databases were searched until June 1, 2021 for relevant studies comparing POLARx versus AFA-Pro in patients undergoing pulmonary vein isolation (PVI) for AF. RESULTS: A total of four studies, involving 310 patients were included. There was no difference between the two groups for outcomes regarding procedural efficacy: acute PVI (odds ratio [OR]: 0.43; 95% confidence interval [CI]: 0.06 to 3.03; p = .40), procedure time (mean difference [MD]: 8.15 min; 95% CI: -8.09 to 24.39; p = .33), fluoroscopy time (MD: 1.32 min; 95% CI: -1.61 to 4.25; p = .38) and ablation time (MD: 1.00 min; 95% CI: -0.20 to 2.20; p = .10). The balloon nadir temperature was lower for all individual pulmonary veins (PV) in POLARx compared with AFA-Pro (MD: -9.74°C, -9.98°C, -6.72°C, -7.76°C, for left superior PV, left inferior PV, right superior PV, and right inferior PV, respectively; all p < .001). The incidence of PNP was similar between groups (OR: 0.79; 95% CI: 0.22 to 2.85; p = .72). CONCLUSION: In AF patients undergoing PVI, POLARx and AFA-Pro had a similar procedural efficacy. Balloon nadir temperatures were lower with POLARx, however, the incidence of PNP was similar.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Humanos , Incidência , Paralisia/diagnóstico , Paralisia/epidemiologia , Paralisia/etiologia , Nervo Frênico , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Temperatura , Resultado do Tratamento
11.
J Cardiovasc Electrophysiol ; 32(3): 580-587, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33492749

RESUMO

INTRODUCTION: Recently a novel cryoballoon system (POLARx, Boston Scientific) became available for the treatment of atrial fibrillation. This cryoballoon is comparable with Arctic Front Advance Pro (AFA-Pro, Medtronic), however, it maintains a constant balloon pressure. We compared the procedural efficacy and biophysical characteristics of both systems. METHODS: One hundred and ten consecutive patients who underwent first-time cryoballoon ablation (POLARx: n = 57; AFA-Pro: n = 53) were included in this prospective cohort study. RESULTS: Acute isolation was achieved in 99.8% of all pulmonary veins (POLARx: 99.5% vs. AFA-Pro: 100%, p = 1.00). Total procedure time (81 vs. 67 min, p < .001) and balloon in body time (51 vs. 35 min, p < .001) were longer with POLARx. After a learning curve, these times were similar. Cryoablation with POLARx was associated with shorter time to balloon temperature -30°C (27 vs. 31 s, p < .001) and -40°C (32 vs. 54 s, p < .001), lower balloon nadir temperature (-55°C vs. -47°C, p < .001), and longer thawing time till 0°C (16 vs. 9 s, p < .001). There were no differences in time-to-isolation (TTI; POLARx: 45 s vs. AFA-Pro 43 s, p = .441), however, POLARx was associated with a lower balloon temperature at TTI (-46°C vs. -37°C, p < .001). Factors associated with acute isolation differed between groups. The incidence of phrenic nerve palsy was comparable (POLARx: 3.5% vs. AFA-Pro: 3.7%). CONCLUSION: The novel cryoballoon is comparable to AFA-Pro and requires only a short learning curve to get used to the slightly different handling. It was associated with faster cooling rates and lower balloon temperatures but TTI was similar to AFA-Pro.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Boston , Criocirurgia/efeitos adversos , Humanos , Estudos Prospectivos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Resultado do Tratamento
12.
J Cardiovasc Electrophysiol ; 32(8): 2148-2158, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34041824

RESUMO

AIMS: Electrographic flow (EGF) mapping is a method to detect action potential sources within the atria. In a double-blinded retrospective study we evaluated whether sources detected by EGF are related to procedural outcome. METHODS: EGF maps were retrospectively generated using the Ablamap® software from unipolar data recorded with a 64-pole basket catheter from patients who previously underwent focal impulse and rotor modulation-guided ablation. We analyzed patient outcomes based on source activity (SAC) and variability. Freedom from atrial fibrillation (AF) was defined as no recurrence of AF, atypical flutter or atrial tachycardia at the follow-up visits. RESULTS: EGF maps were from 123 atria in 64 patients with persistent or long-standing persistent AF. Procedural outcome correlation with SAC peaked at >26%. S-type EGF signature (source-dependent AF) is characterized by stable sources with SAC > 26% and C-type (source-independent AF) is characterized by sources with SAC ≤ 26%. Cases with AF recurrence at 3-, 6-, or 12-month follow-up showed a median final SAC 34%; while AF-free patients had sources with significantly lower median final SAC 21% (p = .0006). Patients with final SAC and Variability above both thresholds had 94% recurrence, while recurrence was only 36% for patients with leading source SAC and variability below threshold (p = .0001). S-type EGF signature post-ablation was associated with an AF recurrence rate 88.5% versus 38.1% with C-type EGF signature. CONCLUSIONS: EGF mapping enables the visualization of active AF sources. Sources with SAC > 26% appear relevant and their presence post-ablation correlates with high rates of AF recurrence.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Átrios do Coração , Humanos , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
13.
Cardiology ; 146(2): 207-212, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33477163

RESUMO

AIMS: The aim of the present study was to compare the rate of actionable arrhythmic events between patients with hypertrophic cardiomyopathy (HCM) who are monitored with an insertable cardiac monitor (ICM) or Holter monitoring. METHODS: We studied 50 patients (mean age 52 years, 72% men) with HCM at low or intermediate risk for sudden cardiac death (SCD), of whom 25 patients received an ICM between November 2014 and February 2019. We retrospectively identified a control group of 25 patients who were matched on age, sex, and HCM Risk-SCD score category. The mean HCM Risk-SCD score was 3.41 ± 1.31 and 3.31 ± 1.43 for the ICM and Holter groups, respectively. The primary endpoint was an actionable event which was defined as an arrhythmic event resulting in a change in patient management. The secondary endpoint was the occurrence of ventricular tachycardia (VT). RESULTS: The cumulative actionable event rate at 30 months was higher in the ICM group (51 vs. 27%, log-rank p value <0.01). De novo atrial fibrillation requiring oral anticoagulation occurred only in the ICM group (n = 3). Overall, 4 implantable cardioverter-defibrillators were implanted for primary prevention (n = 2 in each group). The cumulative rate of VT episodes at 30 months was similar between groups (23% [ICM group] vs. 42% [Holter group], log-rank p value = 0.71). Furthermore, the characteristics of VT were similar between groups with regard to the number of beats and rate. CONCLUSIONS: In adults with HCM, an ICM will detect more arrhythmic events requiring an intervention than a conventional Holter strategy. In contrast, the diagnostic yield of detecting VT seems similar for both groups.


Assuntos
Fibrilação Atrial , Cardiomiopatia Hipertrófica , Desfibriladores Implantáveis , Taquicardia Ventricular , Adulto , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco
14.
Europace ; 22(2): 225-231, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31665276

RESUMO

AIMS: Clinical practice guidelines do not recommend discontinuation of long-term oral anticoagulation in patients with a high stroke risk after catheter ablation for atrial fibrillation (AF). Left atrial appendage closure (LAAC) with Watchman has emerged as an alternative to long-term anticoagulation for patients accepting of the procedural risks. We report on the long-term outcomes of combining catheter ablation procedures for AF and LAAC from multicentre registries. METHODS AND RESULTS: Data were pooled from two prospective, real-world Watchman LAAC registries running in parallel in Europe/Middle-East/Russia (EWOLUTION) and Asia/Australia (WASP) between 2013 and 2015. Of the 1140 patients, 142 subjects at 11 centres underwent a concomitant AF ablation and LAAC procedure. The mean CHA2DS2-VASc score was 3.4 ± 1.4 and HAS-BLED score 1.5 ± 0.9. Successful LAAC was achieved in 99.3% of patients. The 30-day device and/or procedure-related serious adverse event rate was 2.1%. After a mean follow-up time of 726 ± 91 days, 92% of patients remained off oral anticoagulation. The rates of the composite endpoint of ischaemic stroke/transient ischaemic attack/systemic thromboembolism were 1.09 per 100 patient-years (100-PY); and for non-procedural major bleeding were 1.09 per 100-PY. These represent relative reductions of 84% and 70% vs. expected rates per risk scores. CONCLUSION: The long-term outcomes from these international, multicentre registries show efficacy for all-cause stroke prevention and a significant reduction in late bleeding events in a population of high stroke risk post-ablation patients who have been withdrawn from oral anticoagulation.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Isquemia Encefálica , Ablação por Cateter , Acidente Vascular Cerebral , Anticoagulantes , Ásia/epidemiologia , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Austrália , Europa (Continente) , Humanos , Oriente Médio , Estudos Prospectivos , Sistema de Registros , Federação Russa , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
15.
Europace ; 22(4): 584-587, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32003803

RESUMO

AIMS: To investigate the prevalence of electromagnetic interference (EMI) between left ventricular assist devices (LVADs) and implantable cardioverter-defibrillators (ICDs)/pacemakers (PMs). METHODS AND RESULTS: A retrospective single-centre study was conducted, including all patients undergoing HeartMate II (HMII) and HeartMate 3 (HM3) LVAD implantation (n = 106). Electromagnetic interference was determined by the inability to interrogate the ICD/PM. Overall, 85 (mean age 59 ± 8, 79% male) patients had an ICD/PM at the time of LVAD implantation; 46 patients with HMII and 40 patients with HM3. Among the 85 LVAD patients with an ICD's/PM's, 11 patients (13%) experienced EMI; 6 patients (15%) with an HMII and 5 patients (11%) with an HM3 (P = 0.59). Electromagnetic interference from the HMII LVADs was only present in patients with a St Jude/Abbott device; 6 of the 23 St Jude/Abbott devices. However, in the HM3 patients, EMI was mainly present in patients with Biotronik devices: 4 of the 18 with only one (1/25) patient with a Medtronic device. While initial interrogation of these devices was not successful, none of the 11 cases experienced pacing inhibition or inappropriate shocks. CONCLUSION: In summary, the prevalence of EMI between ICDs in the older and newer type of LVAD's remains rather high. While HMII patients experienced EMI with a St Jude/Abbott device (which was already known), HM3 LVAD patients experience EMI mainly with Biotronik devices. Prospective follow-up, preferably in large registries, is warranted to investigate the overall prevalence and impact of EMI in LVAD patients.


Assuntos
Desfibriladores Implantáveis , Coração Auxiliar , Idoso , Desfibriladores Implantáveis/efeitos adversos , Fenômenos Eletromagnéticos , Feminino , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos
16.
Cardiology ; 145(7): 413-420, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32320984

RESUMO

INTRODUCTION: There is limited data on the experience with insertable cardiac monitors (ICMs) in patients with Brugada syndrome. OBJECTIVE: To evaluate the outcome of ICM in symptomatic patients with Brugada syndrome who are at suspected low risk of sudden cardiac death (SCD). METHODS: We conducted a prospective single-center cohort study including all symptomatic patients with Brugada syndrome who received an ICM (Reveal LINQ) between July 2014 and October 2019. The main indication for monitoring was to exclude ventricular arrhythmias as the cause of symptoms and to establish a symptom-rhythm relationship. RESULTS: A total of 20 patients (mean age, 39 ± 12 years; 55% male) received an ICM during the study period. Nine patients (45%) had a history of syncope (presumed nonarrhythmogenic), and 5 patients had a recent syncope (<6 months). During a median follow-up of 32 months (interquartile range, 11-36 months), 3 patients (15%) experienced an episode of nonsustained ventricular arrhythmia. No patient died suddenly or experienced a sustained ventricular arrhythmia, and no patient had a recurrence of syncope. Overall, 17 patients (85%) experienced symptoms during follow-up, of whom 10 patients had an ICM-detected arrhythmia. In 4 patients (20%), the ICM-detected arrhythmia was an actionable event. ICM-guided management included antiarrhythmic drug therapy for symptomatic ectopic beats (n = 3), pulmonary vein isolation, and oral anticoagulation for atrial fibrillation (n = 1), electrophysiological study for risk stratification (n = 1), and pacemaker implantation for atrioventricular block (n = 1). CONCLUSIONS: An ICM can be used to exclude ventricular arrhythmias in symptomatic patients with Brugada syndrome at low risk of SCD. Furthermore, an ICM-detected arrhythmia changed clinical management in 20% of patients.


Assuntos
Bloqueio Atrioventricular/diagnóstico , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/terapia , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Adulto , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Bloqueio Atrioventricular/terapia , Desfibriladores Implantáveis , Eletrocardiografia Ambulatorial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Medição de Risco , Adulto Jovem
17.
Cardiology ; 145(12): 795-801, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32841937

RESUMO

BACKGROUND: Symptomatic idiopathic ventricular arrhythmias (VA), including premature beats (VPB) and nonsustained ventricular tachycardia (VT) are commonly encountered arrhythmias. Although these VA are usually benign, their treatment can be a challenge to primary and secondary health care providers. Mainstay treatment is comprised of antiarrhythmic drugs (AAD) and, in case of drug intolerance or failure, patients are referred for catheter ablation to tertiary health care centers. These patients require extensive medical attention and drug regimens usually have disappointing results. A direct comparison between the efficacy of the most potent AAD and primary catheter ablation in these patients is lacking. The ECTOPIA trial will evaluate the efficacy of 2 pharmacological strategies and 1 interventional approach to: suppress the VA burden, improve the quality of life (QoL), and safety. HYPOTHESIS: We hypothesize that flecainide/verapamil combination and catheter ablation are both superior to sotalol in suppressing VA in patients with symptomatic idiopathic VA. STUDY DESIGN: The Elimination of Ventricular Premature Beats with Catheter Ablation versus Optimal Antiarrhythmic Drug Treatment (ECTOPIA) trial is a randomized, multicenter, prospective clinical trial to compare the efficacy of catheter ablation versus optimal AAD treatment with sotalol or flecainide/verapamil. One hundred eighty patients with frequent symptomatic VA in the absence of structural heart disease or underlying cardiac ischemia who are eligible for catheter ablation with an identifiable monomorphic VA origin with a burden ≥5% on 24-h ambulatory rhythm monitoring will be included. Patients will be randomized in a 1:1:1 fashion. The primary endpoint is defined as >80% reduction of the VA burden on 24-h ambulatory Holter monitoring. After reaching the primary endpoint, patients randomized to one of the 2 AAD arms will undergo a cross-over to the other AAD treatment arm to explore differences in drug efficacy and QoL in individual patients. Due to the use of different AAD (with and without ß-blocking characteristics) we will be able to explore the influence of alterations in sympathetic tone on VA burden reduction in different subgroups. Finally, this study will assess the safety of treatment with 2 different AAD and ablation of VA.


Assuntos
Antiarrítmicos , Ablação por Cateter , Flecainida , Sotalol , Taquicardia Ventricular , Verapamil , Antiarrítmicos/uso terapêutico , Complexos Cardíacos Prematuros/tratamento farmacológico , Complexos Cardíacos Prematuros/cirurgia , Flecainida/uso terapêutico , Humanos , Estudos Prospectivos , Qualidade de Vida , Sotalol/uso terapêutico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento , Verapamil/uso terapêutico
18.
Cardiol Young ; 30(9): 1231-1237, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32698928

RESUMO

BACKGROUND: Catheter ablation is an important therapeutic option for atrial tachycardias in patients with CHD. As a result of extensive scarring and surgical repair, multiple intra-atrial re-entrant tachycardia circuits develop and serve as a substrate for arrhythmias. The best ablation approach for patients with multiple intra-atrial re-entrant tachycardias has not been investigated. Here, we compared substrate-based ablation using extensive scar modification to conventional ablation. METHODS: The present study included patients with surgically corrected CHD that underwent intra-atrial re-entrant tachycardia ablation. Extensive scar modification was defined as substrate ablation based on a dense voltage map, aimed to eliminate all potentials in the scar region. The control group had activation mapping-based ablation. A clinical composite endpoint was assessed. Points were given for type, number, and treatment of intra-atrial re-entrant tachycardia recurrence. RESULTS: In 40 patients, 63 (extensive scar modification 13) procedures were performed. Acute procedural success was achieved in 78%. Procedural duration was similar in both groups. Forty-nine percent had a recurrence within 1 year. During a 5-year follow-up (2.5-7.5 years), 46% required repeat catheter ablation. Compared to baseline, clinical composite endpoint significantly decreased by 46% after 12 months (p = 0.001). Acute procedural success, procedural parameters, recurrence and repeat ablation were similar between extensive scar modification and activation mapping-based ablation. CONCLUSION: Catheter ablation using extensive scar modification for intra-atrial re-entrant tachycardias occurring after surgically corrected CHD illustrated similar short- and long-term outcomes and procedural efficiency compared to catheter ablation using activation mapping-based ablation. The choice of ablation approach for multiple intra-atrial re-entrant tachycardia should remain at the discretion of the operator.


Assuntos
Ablação por Cateter , Cardiopatias Congênitas , Taquicardia Supraventricular , Cicatriz/etiologia , Cicatriz/cirurgia , Cardiopatias Congênitas/cirurgia , Humanos , Taquicardia/cirurgia , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento
19.
Echocardiography ; 36(5): 980-986, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30905087

RESUMO

Both transesophageal echocardiography (TEE) and intracardiac echocardiography have been used to assist transvenous lead extractions. The clinical utility of continuous echocardiographic monitoring during the procedure is still debated, with different reports supporting opposite findings. In cases where the procedure is expected to be difficult, we propose adding a continuous TEE monitoring using a static 3D/multiplane probe in mid-esophageal position, with digital remote manipulation of the field of view. This approach may improve the chances of a successful extraction, increase safety, or even guide the entire intervention. We present here a short case series where continuous monitoring by TEE played an important role.


Assuntos
Remoção de Dispositivo/métodos , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Coração/diagnóstico por imagem , Monitorização Intraoperatória/métodos , Adulto , Idoso , Desfibriladores Implantáveis , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Radiologia Intervencionista/métodos