Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Clin Spine Surg ; 36(2): E59-E69, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36191093

RESUMO

STUDY DESIGN: Prospective randomized Food and Drug Administration investigational device exemption clinical trial. OBJECTIVE: The purpose of the present study is to report the 1-year clinical and radiographic outcomes and safety profile of patients who underwent lumbar facet arthroplasty through implantation of the Total Posterior Spine System (TOPS) device. SUMMARY OF BACKGROUND DATA: Lumbar facet arthroplasty is one proposed method of dynamic stabilization to treat grade-1 spondylolisthesis with stenosis; however, there are currently no Food and Drug Administration-approved devices for facet arthroplasty. METHODS: Standard demographic information was collected for each patient. Radiographic parameters and patient-reported outcome measures were assessed preoperatively and at regular postoperative intervals. Complication and reoperation data were also collected for each patient. RESULTS: At the time of this study, 153 patients had undergone implantation of the TOPS device. The mean surgical time was 187.8 minutes and the mean estimated blood loss was 205.7cc. The mean length of hospital stay was 3.0 days. Mean Oswestry Disability Index, Visual Analog Score leg and back, and Zurich Claudication Questionnaire scores improved significantly at all postoperative time points ( P >0.001). There were no clinically significant changes in radiographic parameters, and all operative segments remained mobile at 1-year follow-up. Postoperative complications occurred in 11 patients out of the 153 patients (7.2%) who underwent implantation of the TOPS device. Nine patients (5.9%) underwent a total of 13 reoperations, 1 (0.6%) of which was for device-related failure owing to bilateral L5 pedicle screw loosening. CONCLUSIONS: Lumbar facet arthroplasty with the TOPS device demonstrated a statistically significant improvement in all patient-reported outcome measures and the ability to maintain motion at the index level while limiting sagittal translation with a low complication rate.


Assuntos
Fusão Vertebral , Estenose Espinal , Espondilolistese , Humanos , Artroplastia , Constrição Patológica/cirurgia , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Estudos Prospectivos , Fusão Vertebral/métodos , Estenose Espinal/diagnóstico por imagem , Estenose Espinal/cirurgia , Estenose Espinal/etiologia , Espondilolistese/diagnóstico por imagem , Espondilolistese/cirurgia , Resultado do Tratamento
2.
Neurosurgery ; 88(3): 497-505, 2021 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-33372218

RESUMO

BACKGROUND: Short- and mid-term studies have shown the effectiveness of cervical disc arthroplasty (CDA) to treat cervical disc degeneration. OBJECTIVE: To report the 10-yr outcomes of a multicenter experience with cervical arthroplasty for 1- and 2-level pathology. METHODS: This was a prospective study of patients treated with CDA at 1 or 2 contiguous levels using the Mobi-C® Cervical Disc (Zimmer Biomet). Following completion of the 7-yr Food and Drug Administration postapproval study, follow-up continued to 10 yr for consenting patients at 9 high-enrolling centers. Clinical and radiographic endpoints were collected out to 10 yr. RESULTS: At 10 yr, patients continued to have significant improvement over baseline Neck Disability Index (NDI), neck and arm pain, neurologic function, and segmental range of motion (ROM). NDI and pain outcomes at 10 yr were significantly improved from 7 yr. Segmental and global ROM and sagittal alignment also were maintained from 7 to 10 yr. Clinically relevant adjacent segment pathology was not significantly different between 7 and 10 yr. The incidence of motion restricting heterotopic ossification at 10 yr was not significantly different from 7 yr for 1-level (30.7% vs 29.6%) or 2-level (41.7% vs 39.2%) patients. Only 2 subsequent surgeries were reported after 7 yr. CONCLUSION: Our results through 10 yr were comparable to 7-yr outcomes, demonstrating that CDA with Mobi-C continues to be a safe and effective surgical treatment for patients with 1- or 2-level cervical degenerative disc disease.


Assuntos
Artroplastia/tendências , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Degeneração do Disco Intervertebral/diagnóstico por imagem , Degeneração do Disco Intervertebral/cirurgia , Adulto , Artroplastia/métodos , Feminino , Seguimentos , Humanos , Disco Intervertebral/diagnóstico por imagem , Disco Intervertebral/cirurgia , Masculino , Pessoa de Meia-Idade , Cervicalgia/diagnóstico por imagem , Cervicalgia/cirurgia , Estudos Prospectivos , Amplitude de Movimento Articular/fisiologia , Fatores de Tempo , Substituição Total de Disco/métodos , Substituição Total de Disco/tendências , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA