Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Int Heart J ; 65(2): 359-362, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38479849

RESUMO

Spontaneous remission is often observed in extracardiac cases of sarcoidosis, such as skin sarcoidosis. However, for cardiac sarcoidosis (CS), the prognosis is unfavorable. Although corticosteroids are the first-line treatment for CS, data regarding the natural history of isolated CS are limited. We describe a rare case of isolated CS with severe left ventricular systolic dysfunction that improved without steroid therapy.


Assuntos
Cardiomiopatias , Miocardite , Sarcoidose , Disfunção Ventricular Esquerda , Humanos , Cardiomiopatias/complicações , Cardiomiopatias/tratamento farmacológico , Remissão Espontânea , Fluordesoxiglucose F18 , Estudos Retrospectivos , Sarcoidose/complicações , Sarcoidose/diagnóstico , Sarcoidose/tratamento farmacológico , Disfunção Ventricular Esquerda/tratamento farmacológico , Disfunção Ventricular Esquerda/etiologia , Esteroides , Tomografia por Emissão de Pósitrons
2.
Ther Adv Cardiovasc Dis ; 18: 17539447241233168, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38396350

RESUMO

BACKGROUND: Although guidelines recommend intracoronary acetylcholine (ACh) and ergonovine (ER) provocation testing for diagnosis of vasospastic angina, the feasibility and safety of sequential (combined) use of both pharmacological agents during the same catheterization session remain unclear. OBJECTIVES: In this study, we investigated the feasibility and safety of sequential intracoronary ACh and ER administration for coronary spasm provocation testing. METHODS: The study included 235 patients who showed positive results on ACh and ER provocation testing. Initial intracoronary ACh administration was followed by ER administration for left coronary artery (LCA) spasm provocation testing. Subsequently, the right coronary artery (RCA) was subjected to sequential ACh and ER administration for provocation testing. The primary outcome of the study was the safety of sequential intracoronary ACh and ER provocation testing, which was assessed based on a composite of all-cause death, sustained ventricular tachycardia and fibrillation, and cardiogenic shock. RESULTS: Even in patients with negative results on sequential intracoronary ACh and ER provocation testing in the LCA and only ACh administration into the RCA, additional administration of ER into the RCA showed a positive provocation test result in 33 of 235 (14.0%) patients; three (1.3%) patients developed adverse effects (cardiogenic shock occurred in all cases) during LCA provocation testing. We observed no deaths attributable to spasm provocation testing. CONCLUSION: Sequential administration of intracoronary ACh and ER was associated with a relatively low major complication rate and may be safe and potentially useful for diagnosis of vasospastic angina.


Safety and potential usefulness of novel coronary spasm provocation testing protocolCoronary spasm represents a subtype of ischemic heart disease, potentially leading to heart attack. Although guidelines recommend intracoronary administration of different pharmacological agents, acetylcholine (ACh) and ergonovine (ER), for coronary spasm provocation testing, the feasibility and safety of sequential (combined) use of both drugs are unclear. In the present study, we showed that sequential administration of intracoronary ACh and ER was associated with a relatively low major complication rate and may be safe and potentially useful for diagnosis of coronary vasospasm.


Assuntos
Angina Pectoris Variante , Vasoespasmo Coronário , Humanos , Acetilcolina/efeitos adversos , Ergonovina/efeitos adversos , Vasoespasmo Coronário/induzido quimicamente , Vasoespasmo Coronário/diagnóstico , Choque Cardiogênico/induzido quimicamente , Angiografia Coronária , Vasos Coronários , Angina Pectoris Variante/induzido quimicamente , Espasmo/induzido quimicamente
3.
Int J Cardiol ; 371: 49-53, 2023 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-36257475

RESUMO

BACKGROUND: Type A acute aortic dissection (AAD) complicated by coronary malperfusion is a life-threatening disease. In the present study, we compared the clinical characteristics and prognostic impact of treatment strategies including surgical treatment and percutaneous coronary intervention (PCI) in type A AAD patients with RCA and LCA involvement. METHODS: This multicenter registry included 220 patients with type A AAD and either RCA or LCA involvement. Treatment strategies were left to treating physicians. The primary endpoint was in-hospital death. RESULTS: Of 220 patients, 115 (52.3%) and 105 (47.7%) had RCA and LCA involvement. Patients with LCA involvement were more1 likely to present with Killip class IV on admission than those with RCA involvement. Coronary angiography was performed in 52 of 220 (23.6%) patients, among whom 39 (75.0%) underwent subsequent PCI. During the hospitalization, 93 (42.3%) patients died. Patients with LCA involvement had an increased risk of in-hospital mortality compared to those with RCA involvement (54.3% vs. 31.3%, p < 0.001). In patients with RCA involvement, multivariable analysis identified Killip class IV and no surgical treatment as predictors of in-hospital death, while PCI and surgical treatment were indicated as factors associated with lower in-hospital mortality in patients with LCA involvement. CONCLUSIONS: The rates of RCA and LCA involvement were similar in type A AAD. Immediate PCI as a bridge to subsequent surgical treatment might improve survival in patients with type A AAD complicated by coronary malperfusion, especially in those with LCA involvement.


Assuntos
Dissecção Aórtica , Intervenção Coronária Percutânea , Humanos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Intervenção Coronária Percutânea/efeitos adversos , Mortalidade Hospitalar , Dissecção Aórtica/complicações , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Angiografia Coronária , Resultado do Tratamento
5.
JACC Case Rep ; 3(2): 250-254, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34317512

RESUMO

We report a case of spontaneous coronary artery dissection located next to a myocardial bridge in a patient with concomitant takotsubo cardiomyopathy. A fusion image with multidetector-row computed tomography and single-photon emission computed tomography played an important role in the diagnosis of these lesions. (Level of Difficulty: Advanced.).

6.
Intern Med ; 58(8): 1057-1065, 2019 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-30568126

RESUMO

Objective Persistent renal damage (RD) three months after exposure to contrast media is associated with contrast-induced acute kidney injury (CI-AKI) and poor clinical outcomes. Little is known about the role of preprocedural hydration on persistent RD in patients with chronic kidney disease [CKD; estimated glomerular filtration rate (eGFR) <60 mL/min/1.73 m2] undergoing percutaneous coronary intervention (PCI). We therefore examined the use of preprocedural hydration to decrease the incidence of persistent RD. Methods Between 2012 and 2015, 1,230 consecutive patients undergoing PCI, except for patients with an eGFR ≥60 mL/min/1.73 m2, on dialysis, having acute myocardial infarction, or recently having started renin-angiotensin inhibitors, were screened (n=333). Before their index PCI, the 12-h saline group (n=103) received 1 mL/kg/h 0.9% sodium chloride for 12 hours, and the 1-h bicarbonate group (n=63) received 3 mL/kg 154 mEq/L sodium bicarbonate for 1 hour. The control group (n=167) received no pre-procedural hydration. The study outcome of kidney function decline was investigated using the percent-change (%-change) of the calculated creatinine clearance between the baseline value and the lowest value recorded three to six months after index PCI. Results There was less renal function deterioration in the saline group than in the control group, and the bicarbonate group showed deterioration similar to the other groups (%-change; 12-h saline 2.0±11.3% vs. control -5.6±12.6%, p<0.001; vs. 1-h bicarbonate -1.8±14.1%, p=0.18; 1-h bicarbonate vs. control, p=0.14 ANOVA). A multiple regression analysis adjusted for risk factors for persistent RD showed that saline hydration correlated independently with a higher %-change (r=0.262, p<0.001). Conclusion Preprocedural 12-h saline may be better than no preprocedural hydration in preventing mid-term renal insufficiency in CKD patients undergoing PCI.


Assuntos
Injúria Renal Aguda/tratamento farmacológico , Injúria Renal Aguda/etiologia , Hidratação/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Insuficiência Renal Crônica/terapia , Solução Salina/uso terapêutico , Bicarbonato de Sódio/uso terapêutico , Idoso , Idoso de 80 Anos ou mais , Feminino , Hidratação/métodos , Humanos , Masculino , Intervenção Coronária Percutânea/métodos , Estudos Retrospectivos , Fatores de Risco
8.
JACC Cardiovasc Interv ; 11(8): 757-767, 2018 04 23.
Artigo em Inglês | MEDLINE | ID: mdl-29673507

RESUMO

OBJECTIVES: The authors sought to evaluate the accuracy of instantaneous wave-Free Ratio (iFR) pullback measurements to predict post-percutaneous coronary intervention (PCI) physiological outcomes, and to quantify how often iFR pullback alters PCI strategy in real-world clinical settings. BACKGROUND: In tandem and diffuse disease, offline analysis of continuous iFR pullback measurement has previously been demonstrated to accurately predict the physiological outcome of revascularization. However, the accuracy of the online analysis approach (iFR pullback) remains untested. METHODS: Angiographically intermediate tandem and/or diffuse lesions were entered into the international, multicenter iFR GRADIENT (Single instantaneous wave-Free Ratio Pullback Pre-Angioplasty Predicts Hemodynamic Outcome Without Wedge Pressure in Human Coronary Artery Disease) registry. Operators were asked to submit their procedural strategy after angiography alone and then after iFR-pullback measurement incorporating virtual PCI and post-PCI iFR prediction. PCI was performed according to standard clinical practice. Following PCI, repeat iFR assessment was performed and the actual versus predicted post-PCI iFR values compared. RESULTS: Mean age was 67 ± 12 years (81% male). Paired pre- and post-PCI iFR were measured in 128 patients (134 vessels). The predicted post-PCI iFR calculated online was 0.93 ± 0.05; observed actual iFR was 0.92 ± 0.06. iFR pullback predicted the post-PCI iFR outcome with 1.4 ± 0.5% error. In comparison to angiography-based decision making, after iFR pullback, decision making was changed in 52 (31%) of vessels; with a reduction in lesion number (-0.18 ± 0.05 lesion/vessel; p = 0.0001) and length (-4.4 ± 1.0 mm/vessel; p < 0.0001). CONCLUSIONS: In tandem and diffuse coronary disease, iFR pullback predicted the physiological outcome of PCI with a high degree of accuracy. Compared with angiography alone, availability of iFR pullback altered revascularization procedural planning in nearly one-third of patients.


Assuntos
Cateterismo Cardíaco/métodos , Doença da Artéria Coronariana/diagnóstico , Circulação Coronária , Vasos Coronários/fisiopatologia , Hemodinâmica , Idoso , Tomada de Decisão Clínica , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Hiperemia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Valor Preditivo dos Testes , Estudos Prospectivos , Sistema de Registros , Reprodutibilidade dos Testes , Resultado do Tratamento
9.
Int J Cardiol ; 245: 77-82, 2017 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-28789842

RESUMO

BACKGROUND: The impact of successful chronic total occlusion (S-CTO) percutaneous coronary intervention (PCI) on cardiac mortality may differ depending on target CTO vessel; however, to date this has not yet been adequately evaluated. The aim of this study was to investigate the impact of target vessel on cardiac mortality after S-CTO PCI. METHODS: From January 2004 to December 2011, 1517 CTO PCIs were performed in 4 Japanese centers and enrolled in a multicenter registry. Cases were retrospectively analyzed and divided per target vessel treated. The primary endpoint was cardiac mortality during the follow-up period. RESULTS: During the study period, 1424 CTOs with 1 main vessel CTO per patient were analyzed (left anterior descending artery [LAD]: 487, right coronary artery [RCA]: 599, left circumflex [LCx]: 338). 92.3% (n=1314) of cases were S-CTO PCIs. The median follow-up period was 1677 (interquartile range; 811-2463) days. In LAD and RCA CTOs, S-CTO PCI was associated with a lower cardiac mortality rate at 5-year follow-up when compared with unsuccessful CTO (U-CTO) (2.6% vs 9.7%, p=0.01, 2.6% vs 27.3%, p<0.01, respectively). This finding was not present with LCx CTO PCI (2.2% vs 0.0%, p=0.53). Cox regression analysis demonstrated that LAD and RCA S-CTO PCI were independent predictors of a lower cardiac mortality rate (LAD; HR: 0.18, 95% CI: 0.06-0.56; p<0.01; RCA; HR: 0.24, 95% CI: 0.09-0.65; p<0.01). CONCLUSIONS: S-CTO LAD and RCA PCI were associated with a lower long-term cardiac mortality after CTO PCI. This finding was not observed with LCx CTO PCI.


Assuntos
Oclusão Coronária/mortalidade , Oclusão Coronária/cirurgia , Vasos Coronários/cirurgia , Intervenção Coronária Percutânea/mortalidade , Intervenção Coronária Percutânea/métodos , Sistema de Registros , Idoso , Estudos de Coortes , Oclusão Coronária/diagnóstico , Feminino , Seguimentos , Humanos , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Mortalidade/tendências , Estudos Retrospectivos , Fatores de Tempo
10.
J Am Coll Cardiol ; 46(4): 599-605, 2005 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-16098422

RESUMO

OBJECTIVES: We report intravascular ultrasound (IVUS) findings after crush-stenting of bifurcation lesions. BACKGROUND: Preliminary results with the crush-stent technique are encouraging; however, isolated reports suggest that restenosis at the side branch (SB) ostium continues to be a problem. METHODS: Forty patients with bifurcation lesions underwent crush-stenting with the sirolimus-eluting stent. Postintervention IVUS was performed in both branches in 25 lesions and only the main vessel (MV) in 15 lesions; IVUS analysis included five distinct locations: MV proximal stent, crush area, distal stent, SB ostium, and SB distal stent. RESULTS: Overall, the MV minimum stent area was larger than the SB (6.7 +/- 1.7 mm2 vs. 4.4 +/- 1.4 mm2, p < 0.0001, respectively). When only the MV was considered, the minimum stent area was found in the crush area (rather than the proximal or MV distal stent) in 56%. When both the MV and the SB were considered, the minimum stent area was found at the SB ostium in 68%. The MV minimum stent area measured <4 mm2 in 8% of lesions and <5 mm2 in 20%. For the SB, a minimum stent area <4 mm2 was found in 44%, and a minimum stent area <5 mm2 in 76%, typically at the ostium. "Incomplete crushing"--incomplete apposition of SB or MV stent struts against the MV wall proximal to the carina--was seen in >60% of non-left main lesions. CONCLUSIONS: In the majority of bifurcation lesions treated with the crush technique, the smallest minimum stent area appeared at the SB ostium. This may contribute to a higher restenosis rate at this location.


Assuntos
Angioplastia Coronária com Balão/métodos , Implante de Prótese Vascular/métodos , Doença da Artéria Coronariana/terapia , Estenose Coronária/terapia , Stents , Ultrassonografia de Intervenção , Angioplastia Coronária com Balão/instrumentação , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Sistemas de Liberação de Medicamentos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Sirolimo/administração & dosagem , Sirolimo/uso terapêutico
11.
Am J Cardiol ; 98(12): 1559-62, 2006 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-17145209

RESUMO

The neointimal hyperplasia (IH) distribution pattern of in-stent restenotic lesions after sirolimus-eluting stent (SES) implantation has not been well described. We identified 48 in-stent restenotic lesions (41 patients) after SES implantation and performed volumetric intravascular ultrasound analyses. Lumen area, stent area, and IH area at the minimal lumen area site were 2.7 +/- 1.0, 5.4 +/- 1.9, and 2.7 +/- 1.4 mm(2), respectively. IH area at the minimal lumen site was larger in the group with a stent area > or =5.0 mm(2) than the group with a stent area <5.0 mm(2) (3.7 +/- 1.3 vs 1.9 +/- 0.8 mm(2), p <0.001). There were fewer visualized stent struts in lesions with a minimum stent area > or =5.0 mm(2) at the minimum lumen site compared with those with a stent area <5.0 mm(2) (0.69 +/- 0.25 vs 0.83 +/- 0.16, p = 0.04). When we compared lesions in patients with diabetes mellitus with patients without diabetes, minimum lumen areas, percent IH at minimal lumen area, percent IH, and neointima-free stent length were identical. In conclusion, (1) lesions without SES underexpansion at the minimum lumen site had more IH and greater nonuniform stent strut distribution compared with restenotic SESs that were underexpanded, and (2) the IH response did not appear to be more aggressive in patients with diabetes mellitus than in those without diabetes mellitus.


Assuntos
Reestenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Sirolimo/administração & dosagem , Stents , Túnica Íntima/diagnóstico por imagem , Ultrassonografia de Intervenção , Idoso , Reestenose Coronária/complicações , Complicações do Diabetes/diagnóstico por imagem , Feminino , Humanos , Hiperplasia , Masculino
12.
Am J Cardiol ; 98(4): 436-42, 2006 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-16893693

RESUMO

We investigated the fate of postprocedural incomplete stent apposition (ISA) after sirolimus-eluting stent (SES) implantation by evaluating long-term intravascular ultrasound findings in 168 consecutive patients (182 de novo lesions). Postprocedural ISA was defined as > or = 1 stent strut that was clearly separated from the vessel wall with evidence of blood speckle behind the strut without overlapping a side branch. After SES implantation, there were 61 ISA sites in 46 stents in 31 patients (23 at the proximal edge, 7 at the distal edge, and 31 within the stent body). There were no clinical, procedural, or intravascular ultrasound measurement differences between patients and lesions with versus without ISA. At follow-up, 15 acute ISA sites (25%) in 11 patients completely resolved and 40 sites (75%) in 20 patients persisted, although 32 of 46 persisting ISA sites (70%) decreased. There was a greater decrease in effective lumen area and a greater increase in peristent plaque area in the complete-resolution group than in the persistent-ISA group. No lesion developed stent thrombosis or in-stent restenosis (angiographic diameter stenosis > 50%). Six acute ISA sites were also associated with new, late acquired ISA, only 1 of which resulted in aneurysm formation. Although most ISAs after SES implantation do not resolve completely, the incidence of restenosis or thrombosis is not affected.


Assuntos
Implante de Prótese Vascular/efeitos adversos , Materiais Revestidos Biocompatíveis , Estenose Coronária/diagnóstico por imagem , Imunossupressores/uso terapêutico , Sirolimo/uso terapêutico , Stents , Ultrassonografia de Intervenção/métodos , Doença Aguda , Implante de Prótese Vascular/instrumentação , Estenose Coronária/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Falha de Prótese
13.
Circulation ; 108(20): 2473-8, 2003 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-14610010

RESUMO

BACKGROUND: It is not clear why some plaque ruptures lead to acute coronary syndromes (ACS) but others do not. METHODS AND RESULTS: We analyzed 80 plaque ruptures in 74 patients and compared culprit lesions of ACS patients with nonculprit lesions of ACS patients and lesions of non-ACS patients; both culprit and nonculprit plaque ruptures were studied in 6 of 54 ACS patients. Intravascular ultrasound findings suggesting thrombus were observed more frequently in culprit lesions of ACS patients (n=35) compared with nonculprit lesions of ACS patients (n=19) and lesions of non-ACS patients (n=26): 60% versus 32% versus 8% (P<0.001). At the minimal lumen site, smaller lumen areas (3.3+/-1.5 versus 5.4+/-2.6 versus 6.1+/-2.0 mm2, P<0.001) and greater area stenosis (61+/-15% versus 50+/-14% versus 46+/-18%, P=0.002) and plaque burden (80+/-8% versus 71+/-8% versus 69+/-10%, P<0.001) were observed in culprit lesions of ACS patients compared with nonculprit lesions of ACS patients and lesions of non-ACS patients. Lesions were longer (18.7+/-6.4 versus 154.9+/-6.1 versus 12.0+/-4.9 mm, P<0.001) and rupture site remodeling indices were greater (1.26+/-0.21 versus 1.24+/-0.21 versus 1.09+/-0.05, P=0.002). Independent predictors of culprit plaque ruptures in ACS patients were smaller minimum lumen areas (P=0.02) and presence of thrombus (P=0.01). CONCLUSIONS: Ruptured plaques in culprit lesions of ACS patients have smaller lumens; greater plaque burdens, area stenosis, and remodeling indices; and more thrombus. Plaque rupture itself does not lead to symptoms. The association of plaque rupture with a smaller lumen area and/or thrombus formation causes lumen compromise and leads to symptoms.


Assuntos
Arteriosclerose/diagnóstico por imagem , Doença das Coronárias/diagnóstico por imagem , Trombose/diagnóstico por imagem , Ultrassonografia de Intervenção , Grau de Desobstrução Vascular , Doença Aguda , Arteriosclerose/classificação , Arteriosclerose/complicações , Doença das Coronárias/etiologia , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Ruptura Espontânea/complicações , Ruptura Espontânea/diagnóstico por imagem , Trombose/complicações
14.
Circulation ; 109(9): 1085-8, 2004 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-14993129

RESUMO

BACKGROUND: We used intravascular ultrasound (IVUS) to evaluate recurrence after sirolimus-eluting stent (SES) implantation treatment of in-stent restenosis (ISR). METHODS AND RESULTS: Forty-eight ISR lesions (41 patients with objective evidence of ischemia) were treated with SES. Recurrent ISR was identified in 11 lesions (all focal); repeat revascularization was performed in 10. These were compared with 16 patients (19 lesions) without recurrence as documented by angiography. Nine of 11 recurrent lesions had a minimum stent area (MSA) <5.0 mm2 versus 5 of 19 nonrecurrent lesions (P=0.003); 7 of 11 recurrent lesions had an MSA <4.0 mm2 versus 4 of 19 nonrecurrent lesions (P=0.02); and 4 of 11 recurrent lesions had an MSA <3.0 mm2 versus 1 of 19 nonrecurrent lesions (P=0.03). A gap between SESs was identified in 3 of 11 recurrences versus 1 of 19 nonrecurrent lesions. CONCLUSIONS: Stent underexpansion is a significant cause of failure after SES implantation treatment of ISR.


Assuntos
Reestenose Coronária/terapia , Sistemas de Liberação de Medicamentos , Sirolimo/administração & dosagem , Stents , Terapia Combinada , Angiografia Coronária , Reestenose Coronária/diagnóstico , Reestenose Coronária/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sirolimo/uso terapêutico , Falha de Tratamento , Ultrassonografia
15.
Circulation ; 110(22): 3430-4, 2004 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-15557367

RESUMO

BACKGROUND: Little is known about causes of intimal hyperplasia (IH) after sirolimus-eluting stent (SES) implantation. METHODS AND RESULTS: Intravascular ultrasound was performed in 24 lesions with intra-SES restenosis and a comparison group of 25 nonrestenotic SESs. To assess stent strut distribution, the maximum interstrut angle was measured with a protractor centered on the stent, and the visible struts were counted and normalized for the number of stent cells. In SES restenosis patients, minimum lumen site was compared with image slices 2.5, 5.0, 7.5, and 10.0 mm proximal and distal to this site. The minimum lumen site had a smaller IVUS lumen area at follow-up (2.7+/-0.9 versus 6.2+/-1.9 mm2; P<0.01), larger maximum interstrut angle (135+/-39 degrees versus 72+/-23 degrees; P<0.01), larger IH area (3.4+/-1.5 versus 0.6+/-1.1 mm2; P<0.01) and thickness (0.7+/-0.3 versus 0.1+/-0.2 mm; P<0.01) at maximum interstrut angle, and fewer stent struts (4.9+/-1.0 versus 6.0+/-0.5; P<0.01) even when normalized for the number of stent cells (0.78+/-0.15 versus 0.97+/-0.07; P<0.01). Compared with nonrestenotic SES, the restenosis lesions also had a smaller minimal lumen area, larger IH area, thicker IH at maximum interstrut angle, fewer stent struts, and larger maximum interstrut angle. Multivariate analysis identified the number of visualized stent struts normalized for the number of stent cells and maximum interstrut angle as the only independent IVUS predictor of IH cross-sectional area (P<0.01 and P<0.01), minimum lumen area (P<0.01 and P<0.01), and IH thickness (P<0.01 and P<0.01). CONCLUSIONS: The number and distribution of stent struts affect the amount of neointima after SES implantation.


Assuntos
Reestenose Coronária/diagnóstico por imagem , Sirolimo/uso terapêutico , Stents , Túnica Íntima/diagnóstico por imagem , Idoso , Angioplastia Coronária com Balão , Angiografia Coronária , Reestenose Coronária/patologia , Reestenose Coronária/prevenção & controle , Estenose Coronária/terapia , Implantes de Medicamento , Desenho de Equipamento , Falha de Equipamento , Feminino , Humanos , Hiperplasia , Masculino , Pessoa de Meia-Idade , Método Simples-Cego , Sirolimo/administração & dosagem , Túnica Íntima/patologia , Ultrassonografia de Intervenção
16.
Am J Cardiol ; 95(3): 355-9, 2005 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-15670544

RESUMO

Patients with acute coronary syndrome are at increased risk of acute and long-term events after stent implantation. We compared the impact of intravascular ultrasound detected plaque rupture on creatine kinase-MB (CK-MB) isoenzyme release and clinical outcomes by comparing 62 patients with ruptured plaques with 62 matched control patients who underwent stent implantation. Two thirds of the patients in each group presented with an acute coronary syndrome. There were no differences in procedural complications between groups, although patients with ruptured plaque had higher CK-MB elevation rates than those without ruptured plaque (1 to 3 times the upper limit of normal CK-MB, 35% vs 10%, p <0.001; >3 times the upper limit, 15% vs 2%, p = 0.02). Independent predictors of CK-MB elevation were presence of ruptured plaque (p = 0.03) and unstable angina (p = 0.04). Patients with ruptured plaque had higher composite rates of late events (target lesion revascularizations/myocardial infarctions/cardiac deaths) than controls (25% vs 9%, p = 0.03). These results were similar when only patients with acute coronary syndrome were studied. Plaque rupture morphology is associated with higher periprocedural CK-MB release and worse 1-year clinical outcome in patients treated with coronary stenting.


Assuntos
Doença da Artéria Coronariana/enzimologia , Doença da Artéria Coronariana/terapia , Creatina Quinase/sangue , Isoenzimas/sangue , Stents , Análise de Variância , Estudos de Casos e Controles , Distribuição de Qui-Quadrado , Cineangiografia , Angiografia Coronária , Creatina Quinase Forma MB , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Ruptura , Estatísticas não Paramétricas , Ultrassonografia de Intervenção
17.
Am J Cardiol ; 95(4): 498-502, 2005 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-15695138

RESUMO

Intravascular ultrasound (IVUS) evaluation was performed in 33 lesions with sirolimus-eluting stent (SES) failure: 4 thromboses, 26 in-stent restenoses (including 6 edge stenoses), 4 new stenoses >5 mm proximal to the stent, and 1 patient with no evidence of the implanted SES (presumably because of embolization). A minimum stent area <5.0 mm(2) (stent underexpansion) was observed in 67% of all SES failures (in particular, 67% of intrastent restenosis); negative remodeling was observed in 4 of 6 stent edge restenoses, and new lesions were secondary to an increase in plaque area.


Assuntos
Reestenose Coronária/diagnóstico por imagem , Trombose Coronária/diagnóstico por imagem , Inibidores da Agregação Plaquetária/administração & dosagem , Sirolimo/administração & dosagem , Stents/efeitos adversos , Ultrassonografia de Intervenção , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Falha de Tratamento
18.
Am J Cardiol ; 96(3): 352-7, 2005 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-16054456

RESUMO

Coronary calcium is intimately associated with coronary atherosclerotic plaque development, although it is controversial as to whether coronary calcium is associated with plaque instability. We analyzed 101 IVUS-detected ruptured plaques and compared them with 101 computer-matched control plaques without evidence of plaque rupture. The arc of calcium was measured every 0.5 mm within 10-mm-long segments that spanned the minimum lumen cross-sectional area, and the number and length of calcium deposits were assessed. Ruptured plaques had a significantly larger number of individual calcium deposits than control plaques (3.5 +/- 1.7 vs 1.8 +/- 1.1, p <0.001). However, the arc of the largest calcium deposit was smaller and the length of the largest calcium deposit in each plaque was shorter in ruptured plaques compared with control plaques (67.3 degrees +/- 41.4 degrees vs 114.9 degrees +/- 77.4 degrees , p <0.001, and 1.6 +/- 1.3 vs 4.0 +/- 2.7 mm, p <0.001, respectively). There was no difference in the number of superficial calcium deposits between the 2 groups, although ruptured plaques had significantly smaller arcs of superficial calcium compared with control plaques (56.2 degrees +/- 35.5 degrees vs 95.8 degrees +/- 65.2 degrees , p <0.001). Conversely, the number of deep calcium deposits was significantly larger in ruptured plaques than in control plaques (1.8 +/- 1.4 vs 0.3 +/- 0.6, p <0.001), although the arc of deep calcium was similar in the 2 groups. Ruptured plaques had quantitatively less calcium, especially superficial calcium, but a larger number of small calcium deposits, especially deep calcium deposits. In conclusion, ruptured plaques are associated with a larger number of calcium deposits within an arc of <90 degrees , a larger number of deep calcium deposits, and a remodeling index.


Assuntos
Calcinose/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Ultrassonografia de Intervenção , Idoso , Distribuição de Qui-Quadrado , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Ruptura , Estatísticas não Paramétricas
20.
Int J Cardiol ; 174(2): 313-7, 2014 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-24768390

RESUMO

BACKGROUND: Although combined supine and prone acquisitions improve the detection of inferolateral obstructive coronary artery disease (CAD), the predictors of inaccurate detection of inferolateral ischemia have not been reported by using cadmium zinc telluride (CZT) myocardial perfusion imaging (MPI). METHODS AND RESULTS: Vasodilator stress (99m)Tc tetrofosmin MPI using CZT camera and coronary angiography was performed in 322 patients within an interval of 2 months. Prone MPI was performed immediately after supine MPI. Narrowing of the luminal diameter ≥ 75% was considered significant. The presence of an abnormality on both supine and prone images was considered significant. Combined supine and prone imaging, compared with supine-only quantification, was more specific (93% vs. 72%, respectively, p<0.0001) and accurate (88% vs. 74%, p<0.0001) without compromising sensitivity (82% vs. 68%, p=0.10). The area under the curve for detecting inferolateral ischemia was 0.769 (95% CI 0.705-0.833) for supine imaging and 0.802 (95% CI 0.730-0.875) for combined supine and prone imaging (p<0.05). Multivariable analysis revealed that previous inferolateral myocardial infarction was an independent predictor of a false diagnosis (odds ratio=3.45, 95% confidence interval [CI] 1.62-7.37, p<0.001). CONCLUSIONS: Combined supine and prone quantitative CZT MPI enhances the detection of inferolateral CAD without adversely affecting its sensitivity. However, we recommend inferolateral ischemia be monitored in patients with a history of previous inferolateral MI because previous inferolateral MI is a predictor of inaccurate diagnosis.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Posicionamento do Paciente , Idoso , Cádmio , Feminino , Câmaras gama , Humanos , Masculino , Decúbito Ventral , Reprodutibilidade dos Testes , Estudos Retrospectivos , Decúbito Dorsal , Telúrio , Tomografia Computadorizada de Emissão de Fóton Único , Zinco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA