RESUMO
BACKGROUND: Although fetal blood sampling for pH is well established the use of lactate has not been widely adopted. This study validated the performance and utility of a handheld point-of-care (POC) lactate device in comparison with the lactate and pH values obtained by the ABL 800 blood gas analyzer. METHODS: The clinical performance and influences on accuracy and decision-making criteria were assessed with freshly taken fetal blood scalp samples (n=57) and umbilical cord samples (n=310). Bland-Altman plot was used for data plotting and analyzing the agreement between the two measurement devices and correlation coefficients (R²) were determined using Passing-Bablok regression analysis. RESULTS: Sample processing errors were much lower in the testing device (22.8% vs. 0.5%). Following a preclinical assessment and calibration offset alignment (0.5 mmol/L) the test POC device showed good correlation with the reference method for lactate FBS (R²=0.977, p<0.0001, 95% CI 0.9 59-0.988), arterial cord blood (R²=0.976, p<0.0001, 95% CI 0.967-0.983) and venous cord blood (R²=0.977, p<0.0001, 95% CI 0.968-0.984). CONCLUSIONS: A POC device which allows for a calibration adjustment to be made following preclinical testing can provide results that will correlate closely to an incumbent lactate method such as a blood gas analyzer. The use of a POC lactate device can address the impracticality and reality of pH sample collection and testing failures experienced in day to day clinical practice. For the StatStrip Lactate meter we suggest using a lactate cut-off of 5.1 mmol/L for predicting fetal acidosis (pH<7.20).
Assuntos
Análise Química do Sangue/instrumentação , Parto Obstétrico , Monitorização Fetal/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito , Couro Cabeludo , Feminino , Sangue Fetal/química , Humanos , Concentração de Íons de Hidrogênio , Ácido Láctico/sangue , GravidezRESUMO
OBJECTIVE: We sought to test the hypothesis that an extraperitoneal cesarean section (ECS) technique reduces postoperative pain without increasing intraoperative and postoperative complications. STUDY DESIGN: In a single-center, single-blinded prospective trial we randomized 54 patients with an indication for primary or first repeat cesarean section at term pregnancy to an ECS (n = 27) or transperitoneal cesarean section (TCS) (n = 27) procedure. Patients with suspected abnormal placentation, a history of >1 cesarean section, or major abdominal surgery were excluded. The primary endpoint of the study was maximum abdominal pain measured by numeric rating scale ranging from 0-10. RESULTS: Patients after ECS had significantly less maximum surgical site pain than patients after TCS. Median peak pain scores on postoperative day 1 were 4.00 (interquartile range, 3.00-5.00) for ECS and 5.00 (interquartile range, 4.00-7.00) for TCS, respectively (P = .031). Analgesic requirements, intraoperative nausea, and postoperative shoulder pain were significantly less after ECS. Overall operative time was significantly shorter in ECS, with no difference in delivery time. No bladder injury occurred in either group. There were no differences in estimated blood loss and neonatal outcome. Urogenital distress, urinary tract infection, and bowel dysfunction did not differ at discharge from hospital and 6 weeks after. CONCLUSION: An extraperitoneal approach to cesarean section appears to reduce postoperative pain, usage of analgesics, and intraoperative nausea without an increase in significant complications.
Assuntos
Cesárea/métodos , Dor Pós-Operatória/etiologia , Peritônio/cirurgia , Adulto , Analgésicos/uso terapêutico , Cesárea/efeitos adversos , Feminino , Humanos , Duração da Cirurgia , Medição da Dor , Dor Pós-Operatória/tratamento farmacológico , Gravidez , Resultado do Tratamento , Adulto JovemAssuntos
Monitorização Fetal , Trabalho de Parto , Lactatos/sangue , Sistemas Automatizados de Assistência Junto ao Leito , Couro Cabeludo/irrigação sanguínea , Feminino , Monitorização Fetal/instrumentação , Humanos , Concentração de Íons de Hidrogênio , Gravidez , Sensibilidade e Especificidade , Fatores de TempoRESUMO
OBJECTIVE: To evaluate the efficacy of misoprostol in the treatment of missed or incomplete abortion in relation to uterine position. METHODS: In a retrospective cohort study, misoprostol was evaluated as first-line treatment for missed and incomplete abortion before 13 gestational weeks. Between 2009 and 2011, women received 600 µg of sublingual misoprostol for missed abortion or 400 µg for incomplete abortion. Follow-up examinations were performed 7-10 days later, with the option of a second administration of misoprostol. Success was defined by the absence of vaginal bleeding or sonographic signs of incomplete abortion, and falling levels of ß-human chorionic gonadotropin. RESULTS: In total, 111 women were included in the study. A single-dose regimen was effective for 73 (65.8%) women. The overall success rate, including repeat doses, was 73.0% (81/111). There were no significant differences in treatment success between women with missed abortion and those with incomplete abortion (56/89 [62.9%] vs 18/22 [81.8%]; P=0.152). Anteverted uterine position was associated with significantly higher success rates compared with diverging position (62/86 [72.1%] vs 4/18 [22.2%]; P=0.001). CONCLUSION: Misoprostol is an effective treatment for early pregnancy failure. Uterine position might impact the success of medical treatment for missed abortion.