Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
World J Surg ; 42(12): 3911-3917, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30097706

RESUMO

BACKGROUND: The effect of thoracic epidural analgesia (TEA) on splanchnic blood flow during abdominal surgery remains unclear. The purpose of this study was to examine whether the hemodynamic effects of TEA resulted in microcirculatory alterations to the intestinal serosa, which was visualized using incident dark-field (IDF) videomicroscopy. METHODS: An observational cohort study was performed. In 18 patients, the microcirculation of the intestinal serosa was visualized with IDF. Microcirculatory and hemodynamic measurements were performed prior to (T1) and after administering a bolus of levobupivacaine (T2). If correction of blood pressure was indicated, a third measurement was performed (T3). The following microcirculatory parameters were calculated: microvascular flow index, proportion of perfused vessels, perfused vessel density and total vessel density. Data are presented as median [IQR]. RESULTS: Mean arterial pressure decreased from 73 mmHg (68-83) at T1 to 63 mmHg (±11) at T2 (p = 0.001) with a systolic blood pressure of 114 mmHg (98-128) and 87 (81-97), respectively (p = 0.001). The microcirculatory parameters of the bowel serosa, however, were unaltered. In seven patients, blood pressure was corrected to baseline values from a MAP of 56 mmHg (55-57), while microcirculatory parameters remained constant. CONCLUSION: We examined the effects of TEA on the intestinal serosal microcirculation during abdominal surgery using IDF imaging for the first time in patients. Regardless of a marked decrease in hemodynamics, microcirculatory parameters of the bowel serosa were not significantly affected. TRIAL REGISTRY NUMBER: ClinicalTrials.gov identifier NCT02688946.


Assuntos
Anestesia Epidural , Anestésicos Locais , Intestino Delgado/fisiopatologia , Levobupivacaína , Microcirculação , Membrana Serosa/fisiopatologia , Idoso , Anestésicos Locais/farmacologia , Pressão Arterial/efeitos dos fármacos , Estudos de Coortes , Feminino , Humanos , Intestino Delgado/irrigação sanguínea , Intestino Delgado/diagnóstico por imagem , Levobupivacaína/farmacologia , Masculino , Microcirculação/efeitos dos fármacos , Microscopia de Vídeo , Pessoa de Meia-Idade , Membrana Serosa/irrigação sanguínea , Membrana Serosa/diagnóstico por imagem , Vértebras Torácicas
2.
Tech Coloproctol ; 22(10): 793-800, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30413998

RESUMO

BACKGROUND: Recognition of a non-viable bowel during colorectal surgery is a challenging task for surgeons. Identifying the turning point in serosal microcirculatory deterioration leading up to a non-viable bowel is crucial. The aim of the present study was to determine whether sidestream darkfield (SDF) imaging can detect subtle changes in serosal microcirculation of the sigmoid after vascular transection during colorectal surgery. METHODS: A prospective observational clinical study was performed at a single medical centre. All eligible participants underwent laparoscopic sigmoid resection and measurements were taken during the extra-abdominal phase. Microcirculation was measured at the transected bowel and 20 cm proximal to this point. Microcirculatory parameters such as Microvascular Flow Index (MFI), proportion of perfused vessels (PPV), perfused vessel density (PVD), total vessel density (TVD) and the Heterogeneity Index were determined. Data are presented as median (interquartile range) or mean ± standard deviation. RESULTS: A total of 60 SDF images were acquired for 10 patients. Perfusion parameters and perfused vessel density were significantly lower at the transected bowel compared with the non-transected measurements [MFI 2.29 (1.96-2.63) vs 2.96 (2.73-3.00), p = 0.007; PPV 74% (55-83) vs 94% (86-97), p = 0.007; and PVD 7.61 ± 2.99 mm/mm2 versus 10.67 ± 1.48 mm/mm2, p = 0.009]. Total vessel density was similar between the measurement locations. CONCLUSIONS: SDF imaging can identify changes of the bowel serosal microcirculation. Significantly lower serosal microcirculatory parameters of the vascular transected bowel was seen compared with the non-transected bowel. The ability of SDF imaging to detect subtle differences holds promise for future research on microvascular cut-off values leading to a non-viable bowel.


Assuntos
Colo Sigmoide/cirurgia , Técnicas de Diagnóstico Cardiovascular , Cuidados Intraoperatórios/métodos , Membrana Serosa/irrigação sanguínea , Membrana Serosa/diagnóstico por imagem , Idoso , Colo Sigmoide/irrigação sanguínea , Estudos de Viabilidade , Feminino , Humanos , Masculino , Microcirculação/fisiologia , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA