Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Assunto principal
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Paediatr Anaesth ; 22(4): 365-70, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22295870

RESUMO

BACKGROUND: In recent years, numerous scientific publications have endorsed the superiority of the ProSeal™ laryngeal mask airway (PLMA) over the Classic™ laryngeal mask airway (cLMA) in adults, children, and infants. The PLMA forms a better seal for both the respiratory and gastrointestinal tracts, provides easier access to the gastrointestinal tract, and exerts lower mucosal pressures for a given seal pressure. This study aims to determine whether this superiority can also be observed for the size 1 PLMA used in anesthetized neonates and infants with positive pressure ventilation. METHODS: Sixty consecutive neonates and infants undergoing elective surgical procedures were randomized to airway management with the size 1 PLMA or cLMA. For all patients, we recorded ease of insertion, effective airway time, number of placement attempts, oropharyngeal leak pressure, fiberoptic position, audible leaks, mask displacement, number of reinsertions during maintenance, gastric insufflation, and frequency of blood stain. RESULTS: Ease of insertion, successful insertion in <3 attempts, fiberoptic position of the airway tube, and frequency of blood stain were similar in both groups. Effective airway time was lower for the PLMA group (30.5 vs 35.6 s). Oropharyngeal leak pressure was higher with the PLMA (32.9 vs 22.2 cm H(2)O, P < 0.001) and gastric insufflation less common (0% vs 6%, P = 0.492). There were fewer mask displacements during maintenance of anesthesia with the PLMA (0% vs 26.7%, P < 0.001). Mask reinsertion was not necessary during maintenance of anesthesia with the PLMA, although it was necessary in 14 cases in the cLMA group (0% vs 46%, P < 0.001). Audible leaks were less common with the PLMA (0% vs 46%, P < 0.001). CONCLUSIONS: We conclude that the size 1 PLMA is a stable, safe, and efficacious airway control device during neonatal and infant anesthesia, allowing higher peak airway pressure during positive pressure ventilation, with fewer mask displacements and gastric insufflations than the cLMA.


Assuntos
Máscaras Laríngeas , Manuseio das Vias Aéreas , Anestesia por Inalação , Anestésicos Inalatórios , Feminino , Tecnologia de Fibra Óptica , Humanos , Lactente , Recém-Nascido , Insuflação , Intubação Gastrointestinal , Intubação Intratraqueal/métodos , Máscaras Laríngeas/efeitos adversos , Masculino , Éteres Metílicos , Respiração Artificial , Tamanho da Amostra , Sevoflurano , Vômito/etiologia
2.
Front Pediatr ; 7: 264, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31312623

RESUMO

Background: Congenital heart disease (CHD) is one of the main causes of morbidity and mortality in children. Microcirculatory changes in CHD patients have previously been investigated using a variety of techniques. Handheld videomicroscopy enables non-invasive direct visualization of the microcirculatory bed. The aim of our study was to determine if there are microcirculatory differences among CHD patients based on age and the presence of cyanosis. Methods: A prospective observational study was carried out. Patients with CHD undergoing corrective surgery were evaluated after anesthetic induction prior to surgery. Microcirculation was evaluated using sidestream dark field (SDF) imaging. Hemodynamics and respiratory, biochemical, and tissue perfusion parameters were analyzed. Results: A total of 30 patients were included, of whom 14 were classified as cyanotic and 16 as non-cyanotic. Cyanotic patients had a higher total vessel density (TVD) (p = 0.016), small vessel density (p = 0.004), and perfused small vessel density (p = 0.013), while their microvascular flow index (MFI) was lower (p = 0.013). After adjustment for age and PaO2, cyanotic patients showed increased TVD (p = 0.023), and small vessel density (p = 0.025) compared to non-cyanotic patients but there were no differences on the MFI. Age was directly correlated with total MFI (spearman's rho = 0.499, p = 0.005) and small vessel MFI (spearman's rho = 0.420, p = 0.021). After adjustment for the type of CHD (cyanotic vs. non-cyanotic) patients with MFI and small MFI vessels <3 were younger than those with values ≥3 (p = 0.033 and p = 0.037). Conclusions: SDF-based evaluation of microcirculation in CHD patients showed that patients with cyanotic defects had higher vascular density, as compared to patients with non-cyanotic defects. Younger patients were more likely to have a low MFI regardless of their type of CHD.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA