Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Pacing Clin Electrophysiol ; 47(5): 614-625, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38558218

RESUMO

INTRODUCTION: The use of esophageal temperature monitoring (ETM) for the prevention of esophageal injury during atrial fibrillation (AF) ablation is often advocated. However, evidence supporting its use is scarce and controversial. We therefore aimed to review the evidence assessing the efficacy of ETM for the prevention of esophageal injury. METHODS: We performed a meta-analysis and systematic review of the available literature from inception to December 31, 2022. All studies comparing the use of ETM, versus no ETM, during radiofrequency (RF) AF ablation and which reported the incidence of endoscopically detected esophageal lesions (EDELs) were included. RESULTS: Eleven studies with a total of 1112 patients undergoing RF AF ablation were identified. Of those patients, 627 were assigned to ETM (56%). The overall incidence of EDELs was 9.8%. The use of ETM during AF ablation was associated with a non significant increase in the incidence of EDELs (12.3% with ETM, vs. 6.6 % without ETM, odds ratio, 1.44, 95%CI, 0.49, 4.22, p = .51, I2 = 72%). The use of ETM was associated with a significant increase in the energy delivered specifically on the posterior wall compared to patients without ETM (mean power difference: 5.13 Watts, 95% CI, 1.52, 8.74, p = .005). CONCLUSIONS: The use of ETM does not reduce the incidence of EDELs during RF AF ablation. The higher energy delivered on the posterior wall is likely attributable to a false sense of safety that may explain the lack of benefit of ETM. Further randomized controlled trials are needed to provide conclusive results.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Esôfago , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/prevenção & controle , Esôfago/lesões , Temperatura Corporal , Monitorização Intraoperatória/métodos , Complicações Intraoperatórias/prevenção & controle
2.
Rev Med Suisse ; 20(856-7): 19-24, 2024 Jan 17.
Artigo em Francês | MEDLINE | ID: mdl-38231094

RESUMO

The year 2023 has been extremely rich in new publications in the various subfields of cardiology. Furthermore, the European Society of Cardiology (ESC) has issued revised guidelines focused on the management of acute coronary syndrome (ACS) and endocarditis, as well as an update on the recommendations for the management of heart failure and cardiovascular prevention. The most significant updates according to the Cardiology Department of CHUV are summarized in this review article.


L'année 2023 a été extrêmement riche en nouvelles publications dans les différents sous-domaines de la cardiologie. De plus, la Société européenne de cardiologie (ESC) a formulé des directives révisées axées sur le management du syndrome coronarien aigu (SCA) et de l'endocardite ainsi qu'une mise à jour des recommandations sur la prise en charge de l'insuffisance cardiaque et la prévention cardiovasculaire. Les nouveautés les plus importantes selon l'équipe du Service de cardiologie du CHUV sont résumées dans cet article de synthèse.


Assuntos
Síndrome Coronariana Aguda , Cardiologia , Endocardite , Insuficiência Cardíaca , Humanos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/terapia
3.
Artigo em Inglês | MEDLINE | ID: mdl-38934970

RESUMO

BACKGROUND: Ventricular tachycardia (VT), which can lead to sudden cardiac death, occurs frequently in patients after myocardial infarction. Radiofrequency catheter ablation (RFA) is a modestly effective treatment of VT, but it has limitations and risks. Cardiac magnetic resonance (CMR)-based heart digital twins have emerged as a useful tool for identifying VT circuits for RFA treatment planning. However, the CMR resolution used to reconstruct these digital twins may impact VT circuit predictions, leading to incorrect RFA treatment planning. OBJECTIVES: This study sought to predict RFA targets in the arrhythmogenic substrate using heart digital twins reconstructed from both clinical and high-resolution 2-dimensional CMR datasets and compare the predictions. METHODS: High-resolution (1.35 × 1.35 × 3 mm), or oversampled resolution (Ov-Res), short-axis late gadolinium-enhanced CMR was acquired by combining 2 subsequent clinical resolution (Clin-Res) (1.35 × 1.35 × 6 mm) short-axis late gadolinium-enhanced CMR scans from 6 post-myocardial infarction patients undergoing VT ablation and used to reconstruct a total of 3 digital twins (1 Ov-Res, 2 Clin-Res) for each patient. Rapid pacing was used to assess VT circuits and identify the optimal ablation targets in each digital twin. VT circuits predicted by the digital twins were compared with intraprocedural electroanatomic mapping data and used to identify emergent VT. RESULTS: The Ov-Res digital twins reduced partial volume effects and better predicted unique VT circuits compared with the Clin-Res digital twins (66.6% vs 54.5%; P < 0.01). Only the Ov-Res digital twin successfully identified emergent VT after a failed initial ablation. CONCLUSIONS: Digital twin infarct geometry and VT circuit predictions depend on the magnetic resonance resolution. Ov-Res digital twins better predict VT circuits and emergent VT, which may improve RFA outcomes.

4.
Physiol Meas ; 45(2)2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38266291

RESUMO

Objective.Cardiac arrhythmias are a leading cause of mortality worldwide. Wearable devices based on photoplethysmography give the opportunity to screen large populations, hence allowing for an earlier detection of pathological rhythms that might reduce the risks of complications and medical costs. While most of beat detection algorithms have been evaluated on normal sinus rhythm or atrial fibrillation recordings, the performance of these algorithms in patients with other cardiac arrhythmias, such as ventricular tachycardia or bigeminy, remain unknown to date.Approach. ThePPG-beatsopen-source framework, developed by Charlton and colleagues, evaluates the performance of the beat detectors namedQPPG,MSPTDandABDamong others. We applied thePPG-beatsframework on two newly acquired datasets, one containing seven different types of cardiac arrhythmia in hospital settings, and another dataset including two cardiac arrhythmias in ambulatory settings.Main Results. In a clinical setting, theQPPGbeat detector performed best on atrial fibrillation (with a medianF1score of 94.4%), atrial flutter (95.2%), atrial tachycardia (87.0%), sinus rhythm (97.7%), ventricular tachycardia (83.9%) and was ranked 2nd for bigeminy (75.7%) behindABDdetector (76.1%). In an ambulatory setting, theMSPTDbeat detector performed best on normal sinus rhythm (94.6%), and theQPPGdetector on atrial fibrillation (91.6%) and bigeminy (80.0%).Significance. Overall, the PPG beat detectorsQPPG,MSPTDandABDconsistently achieved higher performances than other detectors. However, the detection of beats from wrist-PPG signals is compromised in presence of bigeminy or ventricular tachycardia.


Assuntos
Fibrilação Atrial , Taquicardia Ventricular , Humanos , Frequência Cardíaca , Fibrilação Atrial/diagnóstico , Fotopletismografia/métodos , Benchmarking , Taquicardia Ventricular/diagnóstico , Algoritmos , Eletrocardiografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA