Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
J Adv Nurs ; 80(7): 2801-2812, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38243619

RESUMO

AIM(S): To assess the effectiveness of sub-epidermal moisture (SEM) assessment technology in the detection of early-stage pressure damage in a critical care unit (CCU) and dark skin tone patients and its impact on hospital-acquired pressure injury (HAPI) incidence. DESIGN: Quality improvement study employing Kurt Lewin's change model emphasizing planning, implementation, evaluation and sustainable change. METHODS: The study evaluated 140 adult patients admitted to the CCU over a 24-week period, from July to December 2022. Retrospective analysis of standard PI care pathways was performed in 90 patients admitted during a 12-week pre-implementation period. Fifty patients were admitted through the subsequent 12-week implementation period. SEM assessments were performed daily at the sacrum and heels and interventions were applied based on SEM assessments; SEM delta ≥0.6 indicating localized oedema or persistent focal oedema. Statistical analyses were performed on anonymized data. RESULTS: Pre-implementation HAPI incidence was 8.9% (N = 8/90). All eight patients were African American with varying skin tones. A 100% reduction in HAPI incidence was achieved in the implementation period which included 35 African American patients. The relative risk of HAPI incidence was 1.6 times higher in the pre-implementation group. CONCLUSION: Implementing SEM assessment technology enabled equitable PI care for all population types and resulted in a 100% reduction of PIs in our CCU. Objective SEM assessments detected early-stage PIs, regardless of skin tone and enabled providing interventions to specific anatomies developing tissue damage as opposed to universal preventive interventions. IMPLICATIONS: PI care pathways relying on visual and tactile skin assessments are inherently biased in providing equitable care for dark skin tone patients. Implementing SEM assessments empowers healthcare practitioners in driving objective clinical interventions, eliminates bias and enables positive PI health outcomes. IMPACT: Implementing SEM assessment technology had three main effects: it detected early tissue damage regardless of skin tone (detection effect), enabled anatomy-specific interventions (treatment effect) and prevented PIs across all population types (prevention effect). The authors have adhered to the Standards for Quality Improvement Reporting Excellence (SQUIRE) 2.0 guidelines. PATIENT OR PUBLIC CONTRIBUTION: No patient or public contribution. What does this paper contribute to the wider global clinical community? Addressing health inequities in pressure injury prevention; Demonstrated effectiveness across patient populations; Resource optimization and enhanced patient safety.


Assuntos
Úlcera por Pressão , Humanos , Úlcera por Pressão/prevenção & controle , Úlcera por Pressão/enfermagem , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Adulto , Idoso , Melhoria de Qualidade , Pigmentação da Pele , Idoso de 80 Anos ou mais , Incidência
2.
J Clin Nurs ; 33(7): 2578-2592, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38716789

RESUMO

AIM: To investigate the feasibility and acceptability of the training process, procedures, measures and recruitment strategies necessary for a future investigation to test the reliability and validity of using positivity resonance measures in health care encounters. BACKGROUND: Although the measurement of positivity resonance is promising, and non-participant observation is considered effective, their approaches to studying nurse-patient relationships have not been fully explored. DESIGN: A mixed-methods observational study. METHODS: Video recordings of 30 nurse-patient dyads completing telehealth video visit encounters were edited and coded using behavioural indicators of positivity resonance. A post-visit survey gathered data on the participants' perceptions of positivity resonance and the study procedures. The research team completed memos and procedural logs to provide narrative data on the study's training, coding, recruitment and operational procedures. The study included 33 persons with cancer and 13 oncology nurses engaging in telehealth video visit encounters at an academic oncology ambulatory care center located in the southeastern United States. RESULTS: Study procedures were found to be feasible and acceptable to participants. An adequate sample of participants (N = 46) were enrolled and retained in the study. Interrater reliability, as evidenced by Cohen's weighted kappa, ranged from .575 to .752 and interclass correlation coefficients >.8 were attainable within a reasonable amount of time and with adequate training. Behavioural indicators of positivity resonance were observed in all telehealth visits and reported by the participants in the perceived positivity resonance survey. The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) checklist guided reporting. CONCLUSIONS: Designing research around the concept of positivity resonance is an innovative and feasible approach to exploring how rapport is cultivated within nurse-patient relationships. RELEVANCE TO PROFESSIONAL PRACTICE: Measuring positivity resonance may hold promise for exploring patient and nurse outcomes including trust, responsiveness, health-related behaviours, well-being, resilience and satisfaction. REPORTING METHOD: The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) checklist guided the reporting of results to ensure that adequate details of the study were provided to ensure an accurate and complete report. PATIENT OR PUBLIC CONTRIBUTION: Planning of the research design and study procedures was done in consultation with nurse clinicians with experience with telehealth and managers responsible within the practice setting where the study was conducted. This ensured the study procedures were ethical, safe, secure and did not create unnecessary burden to the study participants. The study included collecting data from nurse and patient participants about the acceptability of the study procedures.


Assuntos
Estudos de Viabilidade , Relações Enfermeiro-Paciente , Telemedicina , Comunicação por Videoconferência , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Idoso , Neoplasias/enfermagem , Reprodutibilidade dos Testes , Sudeste dos Estados Unidos
3.
J Perianesth Nurs ; 38(3): 382-393, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36609132

RESUMO

PURPOSE: This quality improvement project implemented job-related education for registered nurses (RNs) completing preoperative anesthesia interviews (PAIs) to increase their knowledge and confidence, improve completeness of documented preoperative interviews, and decrease day of surgery (DOS) cancellations. DESIGN: Pre/post implementation design and retrospective chart review. METHODS: An educational module on PAIs was created and RNs working in the pre-admission testing (PAT) clinic were asked to complete the module. Pre and post implementation data was collected on RN knowledge and confidence, assessment completeness, and DOS cancellations. FINDINGS: Knowledge and confidence increases were not statistically significant, although several interview components within PAI documentation improved with statistical significance. Overall DOS cancellations, although not statistically significant, were found to decrease, 1.3% to 1.2%. CONCLUSIONS: Registered nurses' knowledge, confidence and PAI completeness improved after completing the educational module with anesthetic considerations. Patients seen at the PAT clinic for PAIs before the DOS allowed for patient optimization and education leading to decreased preventable DOS cancellations.


Assuntos
Anestesia , Enfermeiras e Enfermeiros , Humanos , Melhoria de Qualidade , Competência Clínica , Estudos Retrospectivos
4.
J Perianesth Nurs ; 38(4): 564-571, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36658031

RESUMO

PURPOSE: This quality improvement (QI) project developed and implemented a hybrid training program, that included online modules and hands-on training for experienced certified registered nurse anesthetists (CRNAs) to increase confidence, knowledge, and competency with ultrasound-guided vascular access (USGVA). DESIGN: This QI project used a pre-post design. Seventeen volunteer CRNAs participated in USGVA training and education, and a 90-day follow-up assessment was performed. METHODS: The Revised Standards for Quality Improvement Reporting Excellence (SQUIRE 2.0) guidelines were used as a framework to assess confidence, knowledge, and hands-on competency of 17 CRNAs who regularly place vascular access devices using USGVA in patients with difficult vascular access at a single facility. These assessments were measured at: (1) baseline, (2) immediately after attending a hybrid training educational program, and (3) 90 days after implementation into clinical practice. Additionally, the number of vascular access attempts required for successful placement of peripheral intravenous (PIV) catheters, arterial catheters, and central venous catheters (CVC) with ultrasound assistance over a 90-day period was reviewed. FINDINGS: Certified registered nurse anesthetists' median confidence score increased significantly from pre- to posteducation (P = .009). The confidence reported from post- to 90 days posteducation improved, however it did not reach statistical significance (P = .812). The knowledge scores from pre- to posteducation indicated significant improvement (P <. 001), as well as from pre- to 90 days posteducation (P = .03). However, knowledge scores from post- to 90 days posteducation revealed a statistically significant decline (P = .004). The overall median score for hands-on USGVA competency declined from post- to 90 days posteducation (P = .109). The number of successful USGVA placements increased from 50% to 80% within a 90-day period. CONCLUSIONS: The implementation of a USGVA hybrid training and education program improved overall provider confidence, knowledge, and competency. While confidence remained high in the 90-day follow-up, knowledge retention declined. Despite a decline in knowledge retention over time, results showed a significant improvement when compared to baseline scores. Although a decline in hands-on USGVA competency was seen at 90 days posteducation, it was not statistically significant. The percentage of overall successful USGVA placements in clinical practice increased following implementation.


Assuntos
Cateterismo Periférico , Enfermeiros Anestesistas , Humanos , Melhoria de Qualidade , Ultrassonografia de Intervenção/métodos , Cateterismo Periférico/métodos
5.
J Perianesth Nurs ; 38(6): 851-859.e2, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37589633

RESUMO

PURPOSE: The purpose of this quality improvement (QI) project was to reintroduce and assess the feasibility of a standardized, electronic health record (EHR) handoff tool and to evaluate the sustainability of a structured, team-based approach in a pediatric postanesthesia care unit (PACU). DESIGN: This QI project used an observational pre-post design using two separate convenience samples of handoffs and perianesthesia providers. METHODS: A standardized EHR handoff tool was reintroduced for operating room to pediatric PACU handoff communication. Handoffs between anesthesia providers, surgery team members, and PACU nurses were observed pre- and postreintroduction of the EHR handoff tool. Anesthesia providers and PACU RNs received training for giving and receiving handoffs and were provided directions on locating the EHR handoff tool. A bedside audit of items communicated for the six handoff phases (introductions, situation, background, assessment, recommendations, and questions), handoff duration, team member participation, and handoff tool utilization were performed for 149 handoffs pre- and 146 handoffs postimplementation. To evaluate sustainability, the audits were compared to postimplementation data from the 2014 pilot handoff project. FINDINGS: Following reintroduction, EHR handoff tool use increased from 4% to 19%. There was a statistically significant increase in items communicated for three of the six handoff phases when using the EHR tool (P < .05). There was no statistically significant increase in handoff duration (mean = 3.66 minutes, SD = 1.57 minutes) with the EHR handoff tool. Surgical team member presence for the team-based handoff increased from 90.7% pre to 95.9% post. Provider compliance with the team-based handoff approach, which includes a PACU RN, surgical team member, and anesthesia team member present for handoff, was sustained and increased 6 years postimplementation. Feedback from anesthesia providers and PACU RNs indicated mixed reports of satisfaction with the EHR tool, perceived handoff efficiency, and consistency in both giving and receiving handoff. Adherence to five of the six structured handoff phases, except introductions, was sustained and even improved 6 years following implementation. CONCLUSIONS: Evidence-based practice for handoff communication supports the use of a team approach and standardized EHR handoff tools. The reintroduction of a standardized EHR handoff tool improved the completeness of information transfer, yet did not lead to widespread adoption nor improved user satisfaction. There is an ongoing need to identify adoptable and sustainable perioperative handoff methods.


Assuntos
Anestesia , Anestesiologia , Transferência da Responsabilidade pelo Paciente , Humanos , Criança , Salas Cirúrgicas , Melhoria de Qualidade , Comunicação
6.
J Perianesth Nurs ; 38(6): 845-850, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37589630

RESUMO

PURPOSE: The use of lung protective ventilation (LPV) during general anesthesia is an effective strategy among certified registered nurse anesthetists (CRNAs) to reduce and prevent the incidence of postoperative pulmonary complications. The purpose of this project was to implement a LPV protocol, assess CRNA provider adherence, and investigate differences in ventilation parameters and postoperative oxygen requirements. DESIGN: This quality improvement project was conducted using a pre- and postimplementation design. METHODS: Sixty patients undergoing robotic laparoscopic abdominal surgery and 35 CRNAs at a community hospital participated. An evidence-based intraoperative LPV protocol was developed, CRNA education was provided, and the protocol was implemented. Pre- and postimplementation, CRNA knowledge, and confidence were assessed. Ventilation data were collected at 1-minute intervals intraoperatively and oxygen requirements were recorded in the postanesthesia care unit (PACU). FINDINGS: Use of intraoperative LPV strategies increased 2.4%. Overall CRNA knowledge (P = .588), confidence (P = .031), and practice (P < .001) improved from pre- to postimplementation. Driving pressures decreased from pre- to postimplementation (P < .001). Supplemental oxygen use on admission to the PACU decreased from 93.3% to 70.0%. CONCLUSIONS: Educational interventions and implementation of a standardized protocol can improve the use of intraoperative LPV strategies and patient outcomes.


Assuntos
Enfermeiros Anestesistas , Respiração Artificial , Humanos , RNA Complementar , Pulmão , Complicações Pós-Operatórias/prevenção & controle , Oxigênio
7.
Crit Care Nurs Q ; 45(1): 42-53, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34818297

RESUMO

Sepsis affects 1.7 million Americans annually and often requires an intensive care unit (ICU) stay. Survivors of ICU can experience long-term negative effects. This quality improvement initiative was designed to increase compliance with ABCDEF bundle elements and improve clinical outcomes. A significant improvement was seen in the completion of spontaneous awakening and breathing trials (P = .002), delirium assessment (P = .041), and early mobility (P = .000), which was associated with a reduction in mortality and 30-day readmission rates. Findings were consistent with other research that demonstrated an improvement in care delivery and some clinical outcomes.


Assuntos
Pacotes de Assistência ao Paciente , Sepse , Cuidados Críticos , Humanos , Unidades de Terapia Intensiva , Melhoria de Qualidade , Sepse/terapia
8.
J Perianesth Nurs ; 36(1): 8-13, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33153878

RESUMO

PURPOSE: This quality improvement project implemented an evidence-based multimodal analgesia protocol among patients undergoing outpatient spine surgery in an attempt to decrease postoperative opioid requirements, postoperative pain scores, and facility and postanesthesia care unit length of stay (LOS). DESIGN: Two independent samples were compared with a preimplementation and postimplementation design. There were 37 patients in the preimplementation group and 36 patients in the postimplementation group. METHODS: Data were collected by a retrospective chart review of neurosurgical patients undergoing spine surgery and included postoperative opioid requirements, postoperative pain scores, facility and postanesthesia care unit LOS, and the number of protocol components implemented on each patient. FINDINGS: Intraoperative and postoperative by mouth opioid requirements were significantly decreased postimplementation. Postoperative opioid requirements decreased, and postimplementation pain scores were reduced across all time points. LOS did not significantly change. CONCLUSIONS: This multimodal analgesia protocol significantly decreased opioid consumption among neurosurgical patients at this surgery center.


Assuntos
Assistência Ambulatorial , Analgesia , Coluna Vertebral , Assistência Ambulatorial/organização & administração , Analgesia/métodos , Analgesia/enfermagem , Analgésicos Opioides/uso terapêutico , Humanos , Dor Pós-Operatória/enfermagem , Melhoria de Qualidade , Estudos Retrospectivos , Coluna Vertebral/cirurgia
9.
Clin Diabetes ; 37(3): 242-249, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31371855

RESUMO

IN BRIEF A1C point-of-care testing (POCT) paired with face-to-face education potentially improves glycemic control in under-resourced populations. In this study, A1C POCT was implemented with same-day face-to-face medication management and education for adults with type 2 diabetes in a public health department in southeastern North Carolina. The combination of POCT, medication management, and education provided together improved glycemic control and decreased clinical inertia in a setting in which access to health care is limited.

10.
J Perianesth Nurs ; 34(3): 622-632, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30528308

RESUMO

PURPOSE: Anesthesia to postanesthesia care unit (PACU) handoffs are often incomplete, imprecise, and highly variable with respect to information transfer, and therefore can jeopardize patient safety. A standardized anesthesia to PACU electronic medical record (EMR)-based patient handoff checklist was implemented and evaluated for its effect on the information transfer. DESIGN: An observational preimplementation and postimplementation design was used. METHODS: Assessment of the completeness and accuracy of information transfer during the PACU handoff was performed for a convenience samples of 100 patients preimplementation, 3 weeks postimplementation, and 3 months postimplementation. FINDINGS: The mean percentage of total handoff checklist items addressed significantly increased 3 weeks and 3 months postimplementation compared with baseline. CONCLUSIONS: The use of a standardized anesthesia to PACU EMR-based handoff checklist significantly increased the percent of accurate information transferred without considerably affecting the duration of the PACU handoff process.


Assuntos
Transferência da Responsabilidade pelo Paciente/normas , Segurança do Paciente , Melhoria de Qualidade , Sala de Recuperação/normas , Anestesiologia/organização & administração , Lista de Checagem , Registros Eletrônicos de Saúde , Humanos , Fatores de Tempo
11.
J Emerg Nurs ; 44(5): 459-465, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29370946

RESUMO

INTRODUCTION: There is a growing number of mental health illnesses (MHIs) in the nation and no standardization of the medical screening examination (MSE) in the emergency department. Many health care organizations are at the tipping point of discarding a battery of laboratory workups. A triage tool-specific to psychiatric chief complaints and cost effective-is needed for the emergency department. METHODS: A nonexperimental, retrospective overlay of the Triage Algorithm for Psychiatric Screening (TAPS) onto previous psychiatric patients' records was performed to determine the sensitivity and specificity of the TAPS in ruling out acute medical illness. The laboratory test results, length of stay (LOS), and cost of treatment for all psychiatric patients were examined to determine if there was a correlation with their TAPS scores or if the use of the TAPS would have resulted in efficient care and cost savings. RESULTS: This study shows the TAPS tool can be used reliably to rule out acute medical illness in patients with psychiatric chief complaints in a community hospital setting with an on-site inpatient psychiatric unit. The TAPS tool appropriately identified low-acuity patients without significant medical illness (TAPS of 0). As such, the TAPS tool could be used in selected settings to expedite psychiatric care and reduce unnecessary laboratory testing. IMPLICATIONS FOR PRACTICE: The results of this project represent a valuable step forward in improving the triage of adult patients who present to the emergency department with psychiatric chief complaints. A reproducible study of the TAPS method was the next practice step in determining feasibility. Use of the TAPS tool can be a method to decease costs and ED crowding. For research and quality improvement projects in the future, addiction chief complaints should be treated as a separate category from psychiatric or medical complaints, as they meet the criteria of both.


Assuntos
Algoritmos , Serviço Hospitalar de Emergência/organização & administração , Programas de Rastreamento/métodos , Transtornos Mentais/diagnóstico , Triagem/métodos , Adulto , Idoso , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Procedimentos Desnecessários
12.
Arch Psychiatr Nurs ; 30(6): 722-728, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27888966

RESUMO

This mixed-methods hospital quality improvement (QI) study primarily aimed to reduce the use of mechanical restraints in a short-stay inpatient psychiatric setting by facilitating change in care delivery through recovery-oriented nursing practice. The implementation of an evidence-based education for psychiatric-mental health registered nurses (PMH-RNs) intended to improve their knowledge of, and attitudes toward, recovery-focused mental health treatment principles. Findings suggest that recovery-oriented training programs for PMH-RNs can be a potentially useful hospital strategy for restraint reduction. In this article, the authors report their findings using the SQUIRE 2.0 framework for publication of QI studies (Ogrinc et al., 2015).


Assuntos
Pacientes Internados/psicologia , Capacitação em Serviço/métodos , Enfermagem Psiquiátrica/educação , Melhoria de Qualidade , Adulto , Atitude do Pessoal de Saúde , Feminino , Grupos Focais , Hospitais , Humanos , Masculino , Transtornos Mentais/enfermagem , Transtornos Mentais/reabilitação , Restrição Física/métodos , Inquéritos e Questionários
13.
J Appl Biomech ; 32(5): 487-503, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27341083

RESUMO

Sit-to-stand transfer is a common task that is challenging for older adults and others with musculoskeletal impairments. Associated joint torques and muscle activations have been analyzed two-dimensionally, neglecting possible three-dimensional (3D) compensatory movements in those who struggle with sit-to-stand transfer. Furthermore, how muscles accelerate an individual up and off the chair remains unclear; such knowledge could inform rehabilitation strategies. We examined muscle forces, muscleinduced accelerations, and interlimb muscle force differences during sit-to-stand transfer in young, healthy adults. Dynamic simulations were created using a custom 3D musculoskeletal model; static optimization and induced acceleration analysis were used to determine muscle forces and their induced accelerations, respectively. The gluteus maximus generated the largest force (2009.07 ± 277.31 N) and was a main contributor to forward acceleration of the center of mass (COM) (0.62 ± 0.18 m/s(2)), while the quadriceps opposed it. The soleus was a main contributor to upward (2.56 ± 0.74 m/s(2)) and forward acceleration of the COM (0.62 ± 0.33 m/s(2)). Interlimb muscle force differences were observed, demonstrating lower limb symmetry cannot be assumed during this task, even in healthy adults. These findings establish a baseline from which deficits and compensatory strategies in relevant populations (eg, elderly, osteoarthritis) can be identified.


Assuntos
Extremidade Inferior/fisiologia , Movimento/fisiologia , Músculo Esquelético/fisiologia , Aceleração , Fenômenos Biomecânicos , Feminino , Voluntários Saudáveis , Humanos , Masculino , Torque , Adulto Jovem
14.
Clin J Oncol Nurs ; 28(4): 397-405, 2024 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-39041688

RESUMO

BACKGROUND: Literature on advanced practice providers (APPs) prescribing chemotherapy independently, without physician cosignature, is limited. OBJECTIVES: This project assessed safety and provider satisfaction for an existing independent APP chemotherapy prescribing privilege at a National Cancer Institute-designated comprehensive cancer center. METHODS: Rate of Reporting to Improve Safety and Quality events associated with APPs with independent chemotherapy prescribing privileges was compared to that of physicians during a three-year period. Satisfaction of APPs with independent chemotherapy prescribing privileges was evaluated. FINDINGS: The odds of a reported event were higher for physicians than for APPs. APP survey responses were positive for readiness, confidence, and satisfaction with independent chemotherapy prescribing privilege.


Assuntos
Antineoplásicos , Segurança do Paciente , Humanos , Segurança do Paciente/normas , Feminino , Antineoplásicos/uso terapêutico , Antineoplásicos/efeitos adversos , Masculino , Pessoa de Meia-Idade , Adulto , Prescrições de Medicamentos/normas , Prescrições de Medicamentos/estatística & dados numéricos , Neoplasias/tratamento farmacológico , Inquéritos e Questionários , Prática Avançada de Enfermagem/normas , Estados Unidos
15.
Dimens Crit Care Nurs ; 43(5): 231-238, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39074225

RESUMO

BACKGROUND: Nursing interventions in the care of pediatric patients with severe traumatic brain injury (TBI) can have a direct effect on intracranial pressure (ICP), yet they have been largely underexplored. Early evidence is therefore needed to describe these relationships and to determine intervention that promotes neuroprotection and recovery. OBJECTIVES: The aim of this study was to examine nursing interventions within the first 72 hours of pediatric severe TBI and their effects on ICP. METHOD: This is a retrospective review of pediatric patients admitted for severe TBI using a quasi-experimental approach to assess nursing interventions and their association with the patients' ICP values prior to and after each intervention. RESULTS: Of the 56 patients who met the inclusion criteria, 3392 intervention events (range, 31-138 events per patient) were reported. Paired t tests conducted for each intervention type found a statistically significant relationship with suctioning and percent change in ICP values (P = .045). All other interventions showed no significant differences. DISCUSSION: Standard nursing interventions, specifically suctioning, in pediatric severe TBI may affect ICP and therefore neuroprotection. Further work is needed to better understand the role and timing of nursing interventions and their influence on cerebral hemodynamics so that future TBI guidelines consider nursing care and their impact on brain injury recovery.


Assuntos
Lesões Encefálicas Traumáticas , Pressão Intracraniana , Humanos , Lesões Encefálicas Traumáticas/enfermagem , Estudos Retrospectivos , Criança , Masculino , Feminino , Adolescente , Pré-Escolar , Enfermagem de Cuidados Críticos
16.
Health Equity ; 8(1): 461-468, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39011072

RESUMO

Introduction: Provider bias against patients of higher weights can contribute to poor health outcomes and decreased quality of care and patient experience. Addressing weight stigma in sexual and reproductive health settings is important, as these encounters can often be patients' only health care touchpoint. Health care providers must be educated about the harms of weight stigma, ways to recognize and confront their biases, and how to advocate for patients of all sizes. Methods: In this quality improvement project, Planned Parenthood health center providers participated in a three-part virtual workshop to improve provider weight bias awareness and understanding using the Health at Every Size framework. Providers completed a pre- and post-survey, as well as a 3-month follow-up survey to assess changes in bias awareness and confidence in applying weight-neutral principles in care interactions. Results: Analysis of pre- and post-survey results showed significant improvements in provider awareness of bias as well as changes in implicit bias scores and confidence providing weight-neutral care. Conclusion: Educating providers about weight contributes to equity of care for patients of higher weights. Formal education such as workshops have the potential to reduce the harms of weight stigma in health care as changing attitudes and confidence are a precursor to behavior change. Research is needed to assess ideal education modalities and whether receiving care from weight bias-prepared providers affects patient outcomes and experiences.

17.
AANA J ; 92(4): 257-268, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39056495

RESUMO

Operating rooms (ORs) use energy-intensive equipment such as anesthesia gas machines, patient monitors, and lights. They are major contributors to an institution's carbon footprint; yet ORs are unoccupied 40% of the time. Implementing an initiative to power down electrical devices can reduce energy consumption, equipment failure, and financial outlay. This quality improvement project developed and implemented a power down initiative for anesthesia staff to use in ORs. The initiative included turning off anesthesia gas machines, patient monitors, auxiliary oxygen delivery, and room lights at the end of scheduled cases in ORs that were not used for emergencies. Convenience audits were conducted. Pre- and postimplementation compliance outcomes showed that there was an increase in powering down the anesthesia gas machine, patient monitor, auxiliary oxygen, and room lights. Powering down unnecessary equipment at this facility has the potential to save approximately $50,000 and prevent the emission of over 80 metric tons of CO2 per year. Other facilities can implement a similar quality improvement project aimed at fiscal and ecological conservation.


Assuntos
Enfermeiros Anestesistas , Salas Cirúrgicas , Salas Cirúrgicas/normas , Humanos , Melhoria de Qualidade , Fontes de Energia Elétrica
18.
Nurse Educ Today ; 142: 106351, 2024 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-39163691

RESUMO

BACKGROUND: Availability of high-level pediatric training for nurses in Malawi is limited. To address this gap, a novel pediatric critical care nurse preceptor program was developed and implemented by pediatric nurse specialists. AIM: Evaluate the effectiveness of a pediatric critical care nurse preceptor program, via change in nurses' knowledge, skills, confidence, and precepting competence. DESIGN: A 12-month pediatric critical care nurse preceptor program with assessments at baseline, end of intensive (3 months), and end of program (6 months). SETTING: Blantyre, Malawi. PARTICIPANTS: Nurses with two or more years of pediatric nursing experience (N = 20) nominated by unit managers. METHODS: Quantitative data were collected throughout program implementation. Assessments included: (1) multiple choice knowledge test, (2) Objective Structured Clinical Examinations in two areas (vital signs and airway, breathing, circulation, disability, exposure assessments; and blood gas and electrolyte analysis), (3) group simulations (cardiopulmonary resuscitation or respiratory distress), (4) Likert-scale clinical confidence survey, and (5) Likert-scale precepting competence survey. Data were analyzed using repeated measures ANOVA with pairwise comparisons. For Likert-scale surveys, median confidence scores were compared using a Friedman test with post hoc pairwise comparisons using Wilcoxon signed-rank tests. RESULTS: Participants demonstrated significant improvement in clinical knowledge (p < .001), vital signs and airway, breathing, circulation, disability, exposure assessment (p = .001), blood gas and electrolyte analysis (p = .001), CPR (p < .001) and respiratory distress (p < .001) simulations, clinical confidence (p = .002), and precepting competence (p = .041). CONCLUSION: This pediatric critical care nurse preceptor program was effective in improving participants' confidence and competence (knowledge and skills) in pediatric critical care nursing and precepting. Results suggest the program's potential to address the shortage of highly trained pediatric critical care nurses in Malawi. This lays groundwork for refining and expanding preceptorship, ultimately improving pediatric critical care nursing education in resource-limited settings.

19.
J Infus Nurs ; 46(6): 313-319, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37920105

RESUMO

Placement of peripheral intravenous catheters (PIVCs) is a frequent occurrence. Yet, PIVCs consistently require multiple attempts for successful cannulation, leading to an increased use of resources and risk of complications. Even though hospitals have established vascular access teams to improve outcomes and increase longevity of PIVCs, not every facility has one, and some struggle to meet demand. In these cases, PIVC placement depends on the confidence and skills of bedside nurses. Difficult access risk identification tools, as well as vein visualization technologies, like near infrared (nIR), have been developed to assist nurses with cannulation. This study sought to explore how hospitals are using vein visualization technology in nurse-driven protocols and to evaluate whether the technology is being meaningfully integrated into venous assessment and PIVC access protocols. In a survey sent to facilities utilizing nIR technology, 48% of respondents incorporated nIR in nurse-driven protocols. Of these respondents, 88% reported improvement in patient satisfaction, 92% saw a reduction in escalations, and 79% reported a reduction in hospital-acquired infections associated with PIVC placement. Integrating vein visualization technology into nurse-driven PIVC placement protocols has the potential to make a positive impact but requires future research to reproduce these findings in clinical studies.


Assuntos
Cateterismo Periférico , Hospitais , Humanos , Administração Intravenosa , Injeções Intravenosas , Cateterismo Periférico/métodos , Inquéritos e Questionários
20.
Crit Care Nurse ; 43(1): 52-58, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36720278

RESUMO

BACKGROUND: Cardiothoracic surgery patients have an increased risk for aspiration and may require enteral access for nutrition. LOCAL PROBLEM: In a cardiothoracic intensive care unit, feeding start times were delayed because of scheduling conflicts with support services. An electromagnetic device (Cortrak 2 Enteral Access System, Avanos Medical) was introduced to allow advanced practice providers (nurse practitioners and physician assistants) to independently establish postpyloric access and reduce dependence on ancillary services. METHODS: A quality improvement study was performed. Pre- and postimplementation data included order time, service arrival, tube placement time, tube positioning, and feeding start times for 207 placements. Pre- and postimplementation surveys were conducted to evaluate advanced practice provider satisfaction with enteral tube placement practices. RESULTS: Feeding start time for initial placement decreased by 35.5% (15.6 hours to 10 hours); for subsequent placement, by 55.2% (15.5 hours to 7.0 hours). Assistance by support services decreased by 80.4% (before implementation, 100 of 100 placements [100%]; after implementation, 21 of 107 placements [19.6%]; P < .001; ϕ = 0.815). Overall, advanced practice provider satisfaction increased. Most participants said that using the electromagnetic device was faster, nutrition was delivered sooner, and implementation was a valuable practice change. CONCLUSIONS: Using an electromagnetic device decreased feeding start times, reduced the need for support services, and increased advanced practice provider satisfaction with small-bowel feeding tube placement practices.


Assuntos
Nutrição Enteral , Intubação Gastrointestinal , Humanos , Nutrição Enteral/efeitos adversos , Intubação Gastrointestinal/efeitos adversos , Intestino Delgado , Unidades de Terapia Intensiva , Fenômenos Eletromagnéticos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA