Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
BMC Geriatr ; 24(1): 703, 2024 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-39182024

RESUMO

BACKGROUND: Monitoring the recovery trajectory during and after hospitalization can be a valuable method to observe whether additional care is needed to optimize recovery. Hand grip strength tests are commonly used to measure an individual's physical condition. Eforto® is a system to monitor hand grip strength and grip work as measures of recovery. We examined the feasibility of daily repeated hand grip tests measured with Eforto® in geriatric inpatients, during hospitalization and at home after discharge. METHODS: Geriatric inpatients (n = 191) were evaluated for grip strength and grip work with Eforto®, twice daily during their admission. We calculated attempt and success rates. Participants were divided into complete, high, moderate, and low attempt/success rate groups to study differences in patient characteristics. Reasons for non-attempt and unsuccessful tests were categorized and analyzed. Nine participants were interviewed about acceptability and user experience within the hospital setting. Four out of twenty participants accepted the invitation to continue the measurements after discharge at home for 4 weeks and were interviewed about acceptability and user experience. RESULTS: Across the 191 participants, the attempt rate was 85% and 86% of the attempted tests was successful. The main reasons for non-attempt were that the patient felt physically unwell (41%), and that the patient was otherwise engaged, for example receiving care or undergoing medical tests (40%). Measurements were unsuccessful mostly because of the patient not having enough strength to reach the 80% threshold needed for the grip work test (60%). Participants in the complete and high attempt/success rate groups had a shorter length of stay (p<0.05) and a lower mortality (p<0.05) than participants in the moderate/low groups. The interview data showed good acceptability and user experience during hospitalization. The acceptability was strengthened by experienced usefulness. Self-monitoring at home resulted in low inclusion rate (20%) and low success rate (25%), with the uncertain time after discharge from the hospital as the main barrier. CONCLUSIONS: For most patients, the tests were feasible in the supervised hospital setting. At-home testing with Eforto® is challenging, primarily because of the uncertain time after discharge from the hospital.


Assuntos
Estudos de Viabilidade , Avaliação Geriátrica , Força da Mão , Hospitalização , Humanos , Masculino , Força da Mão/fisiologia , Feminino , Idoso , Idoso de 80 Anos ou mais , Avaliação Geriátrica/métodos , Alta do Paciente
2.
Aging Clin Exp Res ; 35(4): 835-845, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36897558

RESUMO

INTRODUCTION: We developed Eforto®, an innovative system for (self-)monitoring of grip strength (GS) and muscle fatigability (Fatigue Resistance (FR = time until GS decreased to 50% of maximum during sustained contraction) and grip work (GW = area under the strength-time curve)). The Eforto® system consists of a rubber bulb that is wirelessly connected to a smartphone-based application, and a telemonitoring platform. The aim was to evaluate the validity and reliability of Eforto® to measure muscle fatigability. METHODS: Community-dwelling older persons (n = 61), geriatric inpatients (n = 26) and hip fracture patients (n = 25) were evaluated for GS and muscle fatigability. In community dwellers fatigability was tested twice in the clinic (once with Eforto®, once with Martin Vigorimeter (MV), standard analog handgrip system) and for six consecutive days as a self-assessment at home with Eforto®. In hospitalized participants, fatigability was tested twice using Eforto®, once by a researcher and once by a health professional. RESULTS: Criterion validity was supported by good to excellent correlations between Eforto® and MV for GS (r = 0.95) and muscle fatigability (FR r = 0.81 and GW r = 0.73), and no significant differences in measurements between both systems. Inter-rater and intra-rater reliability for GW were moderate to excellent (intra-class correlation: 0.59-0.94). The standard error of measurement for GW was small for geriatric inpatients and hip fracture patients (224.5 and 386.5 kPa*s) and higher for community-dwellers (661.5 kPa*s). DISCUSSION/CONCLUSION: We established the criterion validity and reliability of Eforto® in older community-dwelling persons and hospitalized patients, supporting the implementation of Eforto® for (self-)monitoring of muscle fatigability.


Assuntos
Força da Mão , Vida Independente , Humanos , Idoso , Idoso de 80 Anos ou mais , Força da Mão/fisiologia , Reprodutibilidade dos Testes , Músculos , Força Muscular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA