Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Indian J Med Res ; 155(5&6): 565-569, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36124504

RESUMO

Background & objectives: The pandemic caused by the SARS-CoV-2 has been a threat to humankind due to the rapid spread of infection and appearance of multiple new variants. In the present study, we report the dynamics and persistence of immunoglobulin G (IgG) and immunoglobulin M (IgM) antibodies in asymptomatic and symptomatic COVID-19 patients by chemiluminescent assay. Methods: A total of 463 serum samples from 218 SARS-CoV-2 PCR-positive patients were collected over a period of 124 days post-onset of disease (POD). Antibody levels were measured by chemiluminescence bioanalyzer. Neutralizing antibody titres were assessed by plaque reduction neutralization test (PRNT) for SARS-CoV-2. Results: Both IgM and IgG started appearing from day five post-infection in symptomatic and asymptomatic patients. IgM antibody response peaked around day 35 POD and rapidly diminished thereafter, with the last IgM-positive sample observed at 90 days POD. IgG antibody response peaked around 45 days POD and persisted till 124 days. The chemiluminescence immunoassay (CLIA) results showed a moderate correlation (R=0.5846, P<0.001) compared with PRNT. Additional analysis indicated a neutralizing titre of 250 corresponded to 12.948 AU/ml of YHLO iFlash SARS-CoV-2 IgG units. Interpretation & conclusions: Both symptomatic and asymptomatic COVID-19 patients seem to initiate production of antibody responses from day five of onset of disease. Although the CLIA gives high sensitivity and specificity and also its binding IgG antibody titres may correlate moderately with protective immunity, our results indicate that the values of binding antibody alone may not be a perfect guide to represent virus neutralization titre during donor selection for plasma therapy. However, IgM and IgG antibody detection may help in monitoring the status of disease progression and burden in the community.


Assuntos
COVID-19 , Humanos , SARS-CoV-2 , Anticorpos Antivirais , Imunoglobulina M , Imunoglobulina G , Sensibilidade e Especificidade
2.
J Med Virol ; 93(12): 6696-6702, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34331713

RESUMO

The pandemic of COVID-19 has caused enormous fatalities worldwide. Serological assays are important for detection of asymptomatic or mild cases of COVID-19, and sero-prevalence and vaccine efficacy studies. Here, we evaluated and compared the performance of seven commercially available enzyme-linked immunosorbent assay (ELISA)s for detection of anti-severe acute respiratory syndrome corona virus 2 (SARS-CoV-2) immunoglobulin G (IgG). The ELISAs were evaluated with a characterized panel of 100 serum samples from qRT-PCR confirmed COVID-19 patients, collected 14 days post onset disease, 100 SARS-CoV-2 negative samples and compared the results with that of neutralization assay. Results were analysed by creating the receiver operating characteristic curve of all the assays in reference to the neutralization assay. All kits, were found to be suitable for detection of IgG against SARS-CoV-2 with high accuracy. The DiaPro COVID-19 IgG ELISA showed the highest sensitivity (98%) among the kits. The assays demonstrated high sensitivity and specificity in detecting the IgG antibodies against SARS-CoV-2. However, the presence of IgG antibodies does not always correspond to neutralizing antibodies. Due to their good accuracy indices, these assays can also aid in tracing mild infections, in cohort studies and in pre-vaccine evaluations.


Assuntos
Anticorpos Antivirais/sangue , Teste para COVID-19/métodos , Ensaio de Imunoadsorção Enzimática , Imunoglobulina G/sangue , SARS-CoV-2/imunologia , Anticorpos Antivirais/imunologia , COVID-19/diagnóstico , COVID-19/imunologia , Ensaio de Imunoadsorção Enzimática/métodos , Ensaio de Imunoadsorção Enzimática/normas , Humanos , Imunoglobulina G/imunologia , Testes de Neutralização , Kit de Reagentes para Diagnóstico , Reprodutibilidade dos Testes , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Sensibilidade e Especificidade
3.
Arch Virol ; 166(12): 3301-3310, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34554303

RESUMO

Currently, the world is witnessing the pandemic of COVID-19, a disease caused by the novel coronavirus SARS-CoV-2. Reported differences in clinical manifestations and outcomes in SARS-CoV-2 infection could be attributed to factors such as virus replication, infiltration of inflammatory cells, and altered cytokine production. Virus-induced aberrant and excessive cytokine production has been linked to the morbidity and mortality of several viral infections. Using a Luminex platform, we investigated plasma cytokine and chemokine levels of 27 analytes from hospitalized asymptomatic (n = 39) and mildly symptomatic (n = 35) SARS-CoV-2-infected patients (in the early phase of infection), recovered individuals (45-60 days postinfection) (n = 40), and uninfected controls (n = 36) from the city of Pune located in the state of Maharashtra in India. Levels of the pro-inflammatory cytokines IL-1ß, IL-6, and TNF-α and the chemokine CXCL-10 were significantly higher, while those of the antiviral cytokines IFN-γ and IL-12 p70 were significantly lower in both asymptomatic and mildly symptomatic patients than in controls. Comparison among the patient categories revealed no difference in the levels of the cytokines/chemokines except for CXCL-10 being significantly higher and IL-17, IL-4, and VEGF being significantly lower in the mildly symptomatic patients. Interestingly, levels of all key analytes were significantly lower in recovered individuals than in those in both patient categories. Nevertheless, the level of CXCL10 was significantly higher in the recovered patients than in the controls, indicating that the immune system of SARS-CoV-2 patients may take a longer time to normalize. Our data suggest that IL-6, IL-1ß, TNF-α, CXCL-10, and reduced antiviral cytokines could be used as biomarkers of SARS-CoV-2 infection.


Assuntos
COVID-19 , Quimiocinas/imunologia , Citocinas/imunologia , Biomarcadores/sangue , COVID-19/diagnóstico , COVID-19/imunologia , Quimiocina CXCL10 , Humanos , Índia/epidemiologia , Interleucina-1beta , Interleucina-6 , Fator de Necrose Tumoral alfa
4.
Indian J Med Res ; 152(1 & 2): 82-87, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32859866

RESUMO

BACKGROUND & OBJECTIVES: The global pandemic caused by SARS-CoV-2 virus has challenged public health system worldwide due to the unavailability of approved preventive and therapeutic options. Identification of neutralizing antibodies (NAb) and understanding their role is important. However, the data on kinetics of NAb response among COVID-19 patients are unclear. To understand the NAb response in COVID-19 patients, we compared the findings of microneutralization test (MNT) and plaque reduction neutralization test (PRNT) for the SARS-CoV-2. Further, the kinetics of NAb response among COVID-19 patients was assessed. METHODS: A total of 343 blood samples (89 positive, 58 negative for SARS-CoV-2 and 17 cross-reactive and 179 serum from healthy individuals) were collected and tested by MNT and PRNT. SARS-CoV-2 virus was prepared by propagating the virus in Vero CCL-81 cells. The intra-class correlation was calculated to assess the correlation between MNT and PRNT. The neutralizing endpoint as the reduction in the number of plaque count by 90 per cent (PRNT90) was also calculated. RESULTS: The analysis of MNT and PRNT quantitative results indicated that the intra-class correlation was 0.520. Of the 89 confirmed COVID-19 patients, 64 (71.9%) showed NAb response. INTERPRETATION & CONCLUSIONS: The results of MNT and PRNT were specific with no cross-reactivity. In the early stages of infection, the NAb response was observed with variable antibody kinetics. The neutralization assays can be used for titration of NAb in recovered/vaccinated or infected COVID-19 patients.


Assuntos
Anticorpos Neutralizantes/isolamento & purificação , Infecções por Coronavirus/sangue , Testes de Neutralização , Pandemias , Pneumonia Viral/sangue , Adolescente , Adulto , Animais , Anticorpos Neutralizantes/imunologia , Anticorpos Antivirais/sangue , Betacoronavirus/imunologia , Betacoronavirus/patogenicidade , COVID-19 , Criança , Chlorocebus aethiops/imunologia , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/imunologia , Infecções por Coronavirus/virologia , Feminino , Humanos , Imunoglobulina G/sangue , Masculino , Pessoa de Meia-Idade , Pneumonia Viral/epidemiologia , Pneumonia Viral/imunologia , Pneumonia Viral/virologia , SARS-CoV-2 , Células Vero/imunologia , Adulto Jovem
5.
Indian J Med Res ; 151(5): 444-449, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32611915

RESUMO

BACKGROUND & OBJECTIVES: Since the beginning of the year 2020, the pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) impacted humankind adversely in almost all spheres of life. The virus belongs to the genus Betacoronavirus of the family Coronaviridae. SARS-CoV-2 causes the disease known as coronavirus disease 2019 (COVID-19) with mild-to-severe respiratory illness. The currently available diagnostic tools for the diagnosis of COVID-19 are mainly based on molecular assays. Real-time reverse transcription-polymerase chain reaction is the only diagnostic method currently recommended by the World Health Organization for COVID-19. With the rapid spread of SARS-CoV-2, it is necessary to utilize other tests, which would determine the burden of the disease as well as the spread of the outbreak. Considering the need for the development of such a screening test, an attempt was made to develop and evaluate an IgG-based ELISA for COVID-19. METHODS: A total of 513 blood samples (131 positive, 382 negative for SARS-CoV-2) were collected and tested by microneutralization test (MNT). Antigen stock of SARS-CoV-2 was prepared by propagating the virus in Vero CCL-81 cells. An IgG capture ELISA was developed for serological detection of anti-SARS-CoV-2 IgG in serum samples. The end point cut-off values were determined by using receiver operating characteristic (ROC) curve. Inter-assay variability was determined. RESULTS: The developed ELISA was found to be 92.37 per cent sensitive, 97.9 per cent specific, robust and reproducible. The positive and negative predictive values were 94.44 and 98.14 per cent, respectively. INTERPRETATION & CONCLUSIONS: This indigenously developed IgG ELISA was found to be sensitive and specific for the detection of anti-SARS-CoV-2 IgG in human serum samples. This assay may be used for determining seroprevalence of SARS-CoV-2 in a population exposed to the virus.


Assuntos
Anticorpos Antivirais/sangue , Betacoronavirus/imunologia , Infecções por Coronavirus/sangue , Infecções por Coronavirus/epidemiologia , Imunoglobulina G/sangue , Pneumonia Viral/sangue , Pneumonia Viral/epidemiologia , COVID-19 , Teste para COVID-19 , Técnicas de Laboratório Clínico/métodos , Infecções por Coronavirus/diagnóstico , Ensaio de Imunoadsorção Enzimática , Humanos , Índia/epidemiologia , Pandemias , Pneumonia Viral/diagnóstico , Valor Preditivo dos Testes , Prevalência , Curva ROC , Reprodutibilidade dos Testes , SARS-CoV-2 , Estudos Soroepidemiológicos
8.
IJID Reg ; 6: 113-119, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36846076

RESUMO

Introduction: Dengue, chikungunya and Japanese encephalitis are the most common arthropod-borne viral diseases in India. Due to overlapping clinical symptoms, accurate, high-quality and timely laboratory-based differential diagnosis is essential for control and containment of outbreaks. This is most commonly done by detection of IgM antibodies in serum using enzyme-linked immunosorbent assays. The Resource Centre for Virus Research and Diagnostic Laboratories (VRDLs) in Pune, India organized an external quality assurance (EQA) study to check the accuracy of serological diagnostics in the VRDL network. Methods: Three panels, one each for anti-dengue virus, anti-chikungunya virus and anti-Japanese encephalitis virus IgM antibodies, comprising six human serum samples (two positive and four negative) were distributed to test the sensitivity, specificity and reproducibility of serological testing in 124 VRDLs across India in 2018-19 and 2019-20. Results: Among the 124 VRDLs, the average concordance for both 2018-19 and 2019-20 was 98%. In 2018-19, 78.33%, 13.33% and 6.66% of VRDLs reported 100% concordance, 91-99% concordance and 81-90% concordance with the reference results, respectively, and 1.66% of VRDLs had concordance <80%. In 2019-20, 79.68%, 14.06% and 4.68% of VRDLs reported 100% concordance, 91-99% concordance and 81-90% concordance with the reference results, respectively, and 1.56% of VRDLs had concordance <80%. Conclusion: The EQA programme was beneficial for assessing and understanding the performance of the VRDLs. The study data indicate good proficiency in serological diagnosis of dengue, chikungunya and Japanese encephalitis in the VRDL network laboratories. Further expansion of the EQA programme to cover other viruses of public health importance will increase confidence among the VRDL network, and generate evidence of high-quality testing.

9.
Lancet Glob Health ; 10(11): e1655-e1664, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36240831

RESUMO

BACKGROUND: India did phased measles-rubella supplementary immunisation activities (MR-SIAs; ie, mass-immunisation campaigns) targeting children aged 9 months to less than 15 years. We estimated measles-rubella seroprevalence before and after the MR-SIAs to quantify the effect on population immunity and identify remaining immunity gaps. METHODS: Between March 9, 2018 and March 19, 2020 we did community-based, cross-sectional serosurveys in four districts in India before and after MR-SIAs. 30 villages or wards were selected within each district, and one census enumeration block from each was selected as the survey cluster. Households were enumerated and 13 children in the younger age group (9 months to <5 years) and 13 children in the older ager group (5 to <15 years) were randomly selected by use of computer-generated random numbers. Serum samples were tested for IgG antibodies to measles and rubella viruses by enzyme immunoassay. FINDINGS: Specimens were collected from 2570 children before the MR-SIA and from 2619 children afterwards. The weighted MR-SIA coverage ranged from 73·7% to 90·5% in younger children and from 73·6% to 93·6% in older children. Before the MR-SIA, district-level measles seroprevalence was between 80·7% and 88·5% among younger children in all districts, and between 63·4% and 84·5% among older children. After the MR-SIA, measles seroprevalence among younger children increased to more than 90% (range 91·5 to 96·0) in all districts except Kanpur Nagar, in which it remained unchanged 80·4%. Among older children, measles seroprevalence increased to more than 90·0% (range 93·7% to 96·5%) in all districts except Hoshiarpur (88·7%). A significant increase in rubella seroprevalence was observed in all districts in both age groups, with the largest effect in Dibrugarh, where rubella seroprevalence increased from 10·6% to 96·5% among younger children. INTERPRETATION: Measles-rubella seroprevalence increased substantially after the MR-SIAs but the serosurvey also identified remaining gaps in population immunity. FUNDING: The Bill & Melinda Gates Foundation and Indian Council of Medical Research.


Assuntos
Sarampo , Rubéola (Sarampo Alemão) , Adolescente , Criança , Humanos , Estudos Transversais , Imunoglobulina G , Índia/epidemiologia , Vacinação em Massa , Sarampo/epidemiologia , Sarampo/prevenção & controle , Rubéola (Sarampo Alemão)/epidemiologia , Rubéola (Sarampo Alemão)/prevenção & controle , Estudos Soroepidemiológicos , Vacinação , Lactente , Pré-Escolar
10.
mSphere ; 6(4): e0049021, 2021 08 25.
Artigo em Inglês | MEDLINE | ID: mdl-34259563

RESUMO

Blood collection using dried blood spots (DBS) provides an easier alternative to venipuncture for sample collection, transport, and storage but requires additional processing that can cause variability in results. Whole-blood samples spotted on four DBS devices and respective paired serum samples were tested for antimeasles and antirubella IgG antibody concentrations by enzyme immunoassay. Elution protocols for DBS devices were optimized for comparability relative to serum samples using 12 adult volunteers. Stability of DBS collected on HemaSpot HF was assessed under various temperature conditions (+4, 22 to 25, and 45°C) at six time points (0, 7, 15, 30, 60, and 90 days) in a controlled laboratory setting using six adult volunteers. Devices were shipped and stored for 30 days at four settings with variable temperature and humidity conditions to assess the impact on antibody concentrations. Three DBS devices demonstrated comparable antibody concentrations with paired sera following optimization. Antibodies recovered from DBS were stable for at least 90 days at 4°C and for 30 days at ambient temperature (22 to 25°C) using the HemaSpot HF device. A drastic decline in antibody concentrations was observed at 45°C, resulting in quantitative and qualitative discrepancies by day 7. HemaSpot HF devices shipped to field sites and stored at ambient temperature and humidity resulted in quantitative, but not qualitative, variability. Measurement of antimeasles and antirubella IgG antibodies with DBS devices is an accurate alternative to testing serum, provided elution protocols are optimized. Stability of HemaSpot HF devices at ambient temperature enables broader use in surveys when serum processing and cold storage are not feasible. IMPORTANCE Dried blood spot (DBS) collection offers various advantages over conventional methods of blood collection, especially when collecting and transporting samples for a serosurvey. Yet use of DBS requires additional processing steps in the laboratory that can add to variability in results. We optimized a protocol to elute IgG antibodies against measles and rubella viruses in four DBS devices, demonstrating high concordance with paired venous sera for most devices. Extensive stability studies with various temperature and storage conditions in the laboratory and in the field were conducted using HemaSpot HF DBS devices prior to its use in one of the largest community-based measles and rubella serological surveys in the world.


Assuntos
Anticorpos Antivirais/sangue , Teste em Amostras de Sangue Seco/instrumentação , Teste em Amostras de Sangue Seco/normas , Imunoglobulina G/sangue , Sarampo/diagnóstico , Kit de Reagentes para Diagnóstico/normas , Adulto , Teste em Amostras de Sangue Seco/métodos , Humanos , Sarampo/sangue , Sarampo/imunologia , Rubéola (Sarampo Alemão)/sangue , Rubéola (Sarampo Alemão)/diagnóstico , Rubéola (Sarampo Alemão)/imunologia , Sensibilidade e Especificidade
11.
Int J Infect Dis ; 112: 103-110, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34543771

RESUMO

OBJECTIVES: Monitoring the antibody responses to SARS-CoV-2 infection and its correlation to clinical spectrum of disease is critical in understanding the disease progression and protection against re-infection. We assessed the nucleocapsid (N) and receptor-binding-domain of spike (SRBD) protein specific IgG and neutralizing antibody (NAb) responses in COVID-19 patients up to 8 months and its correlation with diverse disease spectrum. METHODS: During the first wave of the SARS-CoV-2 pandemic, from 284 COVID-19 patients, 608 samples were collected up to 8 months post infection. The patients were categorized as asymptomatic, symptomatic and severe. The N and SRBD IgG and NAb titers were evaluated and correlated with clinical data. RESULTS: A steep increase in antigen specific antibody titers was observed till 40 days post onset of the disease (POD), followed by a partial decline till 240 days. Severe disease was associated with a stronger SRBD IgG response and higher NAb titers. The persistence of antibody response was observed in 76% against N, 80% against SRBD and 80% for NAbs of cases up to 8 months POD. CONCLUSION: RBD and N protein specific IgG persisted till 240 days POD which correlated with NAb response, irrespective of individual`s symptomatic status indicating overall robust protection against re-infection.


Assuntos
Anticorpos Neutralizantes/imunologia , Anticorpos Antivirais/imunologia , COVID-19 , Nucleocapsídeo/imunologia , Glicoproteína da Espícula de Coronavírus/imunologia , COVID-19/imunologia , Humanos , SARS-CoV-2
14.
J Occup Environ Med ; 45(11): 1167-70, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-14610398

RESUMO

Considering feco-oral transmission of hepatitis E virus (HEV), the risk of the infection was assessed among sewage workers. On the basis of the close contact with sewage, the participants (n = 147) were divided into sewage workers (n = 92) and others (n = 55); none used personal protective equipment (eg, coveralls, boots, gloves) Age-matched individuals from lower socioeconomic status and without any exposure to sewage were used as controls. IgG-anti-HEV positivity in enzyme-linked immunosorbent assay was significantly higher (P < 0.01) among staff members (83/147, 56.5%) than the controls (19%). A significant rise in anti-HEV positivity (P < 0.05) was recorded in sewage workers working for >5 years. Multivariate regression analysis identified contact with sewage as the independent variable associated with anti-HEV positivity. Strict adherence to good working practices must take top priority for protection of these workers from sewage pathogens.


Assuntos
Anticorpos Anti-Hepatite/sangue , Vírus da Hepatite E/imunologia , Hepatite E/etiologia , Exposição Ocupacional/efeitos adversos , Esgotos/efeitos adversos , Adulto , Estudos de Casos e Controles , Ensaio de Imunoadsorção Enzimática , Feminino , Hepatite E/imunologia , Humanos , Índia , Masculino , Fatores de Risco , Classe Social
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA