Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Breast Cancer Res ; 26(1): 85, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38807211

RESUMO

BACKGROUND: Abbreviated breast MRI (FAST MRI) is being introduced into clinical practice to screen women with mammographically dense breasts or with a personal history of breast cancer. This study aimed to optimise diagnostic accuracy through the adaptation of interpretation-training. METHODS: A FAST MRI interpretation-training programme (short presentations and guided hands-on workstation teaching) was adapted to provide additional training during the assessment task (interpretation of an enriched dataset of 125 FAST MRI scans) by giving readers feedback about the true outcome of each scan immediately after each scan was interpreted (formative assessment). Reader interaction with the FAST MRI scans used developed software (RiViewer) that recorded reader opinions and reading times for each scan. The training programme was additionally adapted for remote e-learning delivery. STUDY DESIGN: Prospective, blinded interpretation of an enriched dataset by multiple readers. RESULTS: 43 mammogram readers completed the training, 22 who interpreted breast MRI in their clinical role (Group 1) and 21 who did not (Group 2). Overall sensitivity was 83% (95%CI 81-84%; 1994/2408), specificity 94% (95%CI 93-94%; 7806/8338), readers' agreement with the true outcome kappa = 0.75 (95%CI 0.74-0.77) and diagnostic odds ratio = 70.67 (95%CI 61.59-81.09). Group 1 readers showed similar sensitivity (84%) to Group 2 (82% p = 0.14), but slightly higher specificity (94% v. 93%, p = 0.001). Concordance with the ground truth increased significantly with the number of FAST MRI scans read through the formative assessment task (p = 0.002) but by differing amounts depending on whether or not a reader had previously attended FAST MRI training (interaction p = 0.02). Concordance with the ground truth was significantly associated with reading batch size (p = 0.02), tending to worsen when more than 50 scans were read per batch. Group 1 took a median of 56 seconds (range 8-47,466) to interpret each FAST MRI scan compared with 78 (14-22,830, p < 0.0001) for Group 2. CONCLUSIONS: Provision of immediate feedback to mammogram readers during the assessment test set reading task increased specificity for FAST MRI interpretation and achieved high diagnostic accuracy. Optimal reading-batch size for FAST MRI was 50 reads per batch. Trial registration (25/09/2019): ISRCTN16624917.


Assuntos
Neoplasias da Mama , Curva de Aprendizado , Imageamento por Ressonância Magnética , Mamografia , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico , Imageamento por Ressonância Magnética/métodos , Mamografia/métodos , Pessoa de Meia-Idade , Detecção Precoce de Câncer/métodos , Estudos Prospectivos , Idoso , Sensibilidade e Especificidade , Interpretação de Imagem Assistida por Computador/métodos , Mama/diagnóstico por imagem , Mama/patologia
2.
Soc Sci Med ; 355: 117112, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39029443

RESUMO

Risk communication is a key legal and ethical component of shared decision-making. Decisions about total knee replacement, a common surgery, must contend with the fact that a minority of cases result in unintended outcomes, some of which have devastating effects. To understand how risks are communicated during decision-making, we audio-recorded and analysed 62 consultations between surgeons and patients. Various communication methods were evident, including listing risks without elaboration, discussing them in a conversational manner, abrogating discussion of risk, or using decision-tools. Discussion of risks was often brief in nature, and risk communication was sometimes curtailed or deferred by both patients and surgeons. Risks could also be observed to play a part in reinforcing policy norms of the doctor-patient relationship that highlighted patient responsibility. Nevertheless, patients and surgeons in the observed consultations appeared more interested in developing trusting relationships than in discussing risks. Because patients had sometimes experienced considerable deterioration in their knee function before their consultation, were in pain and struggled with mobility, the realities of clinical practice clashed with the policy norms of choice and patient responsibility. Rather, decisions could appear coerced by the disease process rather than being clear-cut examples of self-determination. While policy norms putatively use risk disclosure to frame communication between patients and clinicians as a transaction between customer and technician, the lack of conformity to these norms in the consultations may indicate resistance to this framing. A greater emphasis on determining positive roles for trust and care would help policy to present a nuanced understanding of decision-making. Risk communication could be seen as a factor in the formation of trusting relationships, improving its role in decision-making processes while recognising its inherent tensions with practice.


Assuntos
Artroplastia do Joelho , Relações Médico-Paciente , Confiança , Humanos , Artroplastia do Joelho/psicologia , Confiança/psicologia , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Tomada de Decisões , Comunicação , Tomada de Decisão Compartilhada , Idoso de 80 Anos ou mais
3.
Continence (Amst) ; 8: None, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38107022

RESUMO

Purpose: Evaluation of a catheter design which protects its tip with the retaining balloon when inflated, and has eyeholes at the base of the balloon to improve drainage. Materials and methods: Preclinical tests included assessment of retaining balloon performance, and microbiological blockage. Clinical testing evaluated short-term use and safety in hospital (stage 1) or the patient's usual residence (stage 2). Results: The retaining balloon supported static loads of 0.7kg, with reduced trauma when modelling forced evulsion. In vitro time to blockage with P. Mirabilis was significantly slower for FLUME compared with latex Foley catheters, but not the silicone Foley. Stage 1 testing (10 patients) confirmed balloon inflation, drainage, retention and removal, with no serious adverse events caused by catheterisation; one balloon failed to inflate, one patient could not be catheterised. Of five patients at stage 2, one had the catheter for 28 days without complication, one experienced spontaneous balloon deflation (14th day) and three needed early removal (blood clot, bypassing, difficulty connecting the drainage bag). Bacterial profiles of two FLUME catheters retained at least 2 weeks matched the Foley catheters. Acquired catheter colouration (two FLUME, one Foley) was not associated with biochemical change in the material. Conclusion: FLUME catheter performed well in preclinical blockage and balloon tests. Tests in 15 patients confirmed basic function and additional training was not needed for staff familiar with Foley catheterisation. Clinical issues commonly seen with catheters included failed catheterisation, clot blockage and bypassing. In addition, an unintended balloon deflation and a failure of bag connection occurred. Plain language summary: This article describes a new catheter design which aims to improve patient comfort and safety, and maximise bladder drainage, by protecting the bladder from the exposed catheter tip and by locating the drainage holes better. Various tests were done to check the catheter retaining balloon was safe and how well the catheter did when exposed to bacteria that could block it. The catheter was also used in people for the first time, to check it could be put in safely and functioned as intended. The results showed the FLUME catheter did well in the balloon and blockage tests. Tests in 15 patients confirmed basic function and showed placement was easy for staff familiar with conventional catheters. There were some clinical issues typical of urinary catheters and some possible improvements were identified.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA