Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Horm Metab Res ; 43(10): 728-30, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21932179

RESUMO

The aim of the present study is 1) to compare our established manual thyroglobulin (Tg) and Tg autoantibody (TgAb) immunoassays to the automated KRYPTOR® platform from the same manufacturer, in a large group of DTC patients and 2) to evaluate whether a change in assay methods could be made without disrupting the serial monitoring pattern. Sera from 160 patients with histologically proven DTC were obtained and Tg and TgAb measured by manual immunoassays and a fully automated platform. We found an excellent agreement between the 2 methods for Tg measurement (R=0.9888, p<0.00001) with a 90% overall concordance rate. At the same time, a weak relationship was found between the two methods for TgAb measurement (R=0.4438, p<0.03). However, 151 patients had concordant results with a 94% overall concordance rate. In conclusion, the excellent correlation we found between the Tg assays make the fully automated KRYPTOR® Tg assay interchangeable with the established Dyno-test® Tg-plus in patients with DTC. A very high qualitative concordance rate was found between Dyno-test® TgAbn and KRYPTOR® TgAb assays, making these methods interchangeable to screen sera for the presence of TgAb. However, since quantitative discordances still occurred in some patients a re-baseline of TgAb positive patients is strongly supported before changing the TgAb assay method.


Assuntos
Autoanticorpos/sangue , Automação , Diferenciação Celular , Imunoensaio/métodos , Tireoglobulina/sangue , Tireoglobulina/imunologia , Neoplasias da Glândula Tireoide/sangue , Neoplasias da Glândula Tireoide/imunologia , Adolescente , Adulto , Idoso , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Neoplasias da Glândula Tireoide/patologia , Adulto Jovem
2.
Am J Clin Pathol ; 97(3): 345-52, 1992 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-1543157

RESUMO

The authors evaluated the performance of four modern, commercially available hematology analyzers for imprecision and inaccuracy in determining the leukocyte differential count. The evaluation was performed according to International Committee for Standardization in Haematology protocols and the National Committee for Clinical Laboratory Standards H20-T standard, using the same group of patients simultaneously. Imprecision was very low among all the analyzers for neutrophils and lymphocytes (coefficient of variation maximum = 4.12%), whereas for the other leukocyte populations it tended to increase as their presence percentage decreased. The imprecision of the analyzers was still lower than that of the microscopic method. The correlation with the manual 800 cell count (inaccuracy) was good for neutrophils, lymphocytes, and eosinophils (r = 0.974 to 0.888), less so for monocytes (r = 0.757 to 0.490), whereas it was poor for basophils (r = 0.532 to 0.078).


Assuntos
Contagem de Células Sanguíneas/instrumentação , Adolescente , Adulto , Idoso , Estudos de Avaliação como Assunto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Regressão
3.
Eur J Clin Chem Clin Biochem ; 31(4): 251-8, 1993 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-8318574

RESUMO

The diagnostic performance of the haematology analysers, Technicon H1, Sysmex NE 8000, Coulter STKS and Sequoia Cell Dyn 3000 was determined by comparing their results for automated differential counting with the result obtained for 400 cells by the manual microscopic method. These comparative studies were performed on a group of adults, containing both normal individuals (n = 150) and those affected by various pathologies (n = 113). The number of morphologically false negatives is low for all the systems (from 1.8% for the Cell Dyn 3000 to 6.2% for the NE 8000), while the number of distributionally false negatives was slightly higher (from 4.4% for the Cell Dyn 3000 to 7% for the H1 and NE 8000). The morphological flags, though useful for improving the diagnostic performance of the instruments, show a rather modest sensitivity when taken individually: immature granulocytes/bands from 71% for the STKS to 43% for the NE 8000; blasts from 66.6% for the H1 to 53.3% for the STKS, atypical lymphocytes from 59% for the H1 to 13.6% for the NE 8000; erythroblasts from 42.8% for the STKS to 7% for the NE 8000.


Assuntos
Contagem de Leucócitos/instrumentação , Adulto , Idoso , Autoanálise , Coleta de Amostras Sanguíneas , Estudos de Avaliação como Assunto , Reações Falso-Negativas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA