Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Invasive Cardiol ; 28(11): E132-E133, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27801661

RESUMO

OBJECTIVES: We aimed to illustrate one of the mechanisms of rotational atherectomy burr entrapment in a coronary stent where the burr was rolled up in the stent's struts. METHODS: We report a case where the treatment of a mid right coronary artery (RCA) lesion using a rotational atherectomy device was attempted. During the procedure, the burr suddenly got stuck in a freshly implanted stent in the distal RCA. Despite several attempts and maneuvers, we were unable to pull back the burr. RESULTS: The patient was transferred for emergency surgery. The length of the RCA from its proximal third to the crux, including the stuck burr and the freshly implanted stent, had to be extracted. CONCLUSIONS: Physicians performing rotational atherectomy should be aware of this complication and know the principal endovascular maneuvers to extract the stuck burr. Operators should also be aware of roll-up burr entrapment, like this case, where most maneuvers to retrieve the burr will fail and should be managed, to our point of view, with surgery.


Assuntos
Angioplastia Coronária com Balão , Aterectomia Coronária , Estenose Coronária , Vasos Coronários , Procedimentos Endovasculares , Idoso , Angioplastia Coronária com Balão/instrumentação , Angioplastia Coronária com Balão/métodos , Aterectomia Coronária/efeitos adversos , Aterectomia Coronária/instrumentação , Aterectomia Coronária/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/complicações , Estenose Coronária/diagnóstico , Estenose Coronária/etiologia , Estenose Coronária/fisiopatologia , Estenose Coronária/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Humanos , Complicações Intraoperatórias/diagnóstico , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/cirurgia , Masculino , Transferência de Pacientes , Ajuste de Prótese/métodos , Stents/efeitos adversos , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/métodos
2.
Eur J Cardiothorac Surg ; 34(3): 635-40, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18635371

RESUMO

OBJECTIVE: Assess the performance of self-expanding venous cannulas for routine use in open-heart surgery. METHODS: Prospective study in 100 unselected consecutive patients undergoing open-heart surgery with either remote or central smart venous cannulation. RESULTS: The study focuses on the 76 consecutive adult patients (mean age 59.2+/-17.3 years; 60 males, 16 females) undergoing surgical procedures with total cardiopulmonary bypass for either valve procedures (42/76 patients=55.3%), ascending aorta and arch repair (20/76 patients=26.3%), coronary artery revascularization (13/76 patients=17.1%) or other procedures (11/76 patients=14.5%) with 14/76 patients (18.4%) undergoing redo surgery and 6/76 patients (7.9%) undergoing small access surgery. The mean pump flow achieved by gravity drainage alone accounted for 5.0+/-0.6l/min (=114% of target) in the entire study population (n=76) as compared to the calculated, theoretical pump flow of 4.4+/-0.5l/min (p<0.0001). For the femoral cannulation sub-group (n=35) pump flow achieved by gravity drainage alone accounted for 4.9+/-0.6l/min (=114% of target) as compared to the calculated theoretical pump flow of 4.3+/-0.4l/min (p<0.0001). The corresponding numbers for trans-subclavian cannulation (n=7) are 5.2+/-0.5l/min (111%) for the pump flow achieved by gravity drainage as compared to the theoretical target flow of 4.7+/-0.4l/min. For the central cannulation sub-group (n=34) mean flow achieved by gravity drainage with a self-expanding venous cannula accounted for 5.1+/-0.7l/min (=116% of target) as compared to the calculated theoretical flow of 4.4+/-0.6l/min (p<0.0001). CONCLUSION: Full or more than target flow was achieved in 97% of the patients studied undergoing CPB with self-expanding venous cannulas and gravity drainage. Remote venous cannulation with self-expanding cannulas provides similar flows as central cannulation. Augmentation of venous return is no longer necessary.


Assuntos
Ponte Cardiopulmonar/instrumentação , Cateterismo Venoso Central/instrumentação , Cateterismo Periférico/instrumentação , Adulto , Idoso , Procedimentos Cirúrgicos Cardíacos/instrumentação , Desenho de Equipamento , Feminino , Veia Femoral , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reoperação , Veia Subclávia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA