Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Strength Cond Res ; 35(Suppl 1): S158-S165, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-30747900

RESUMO

ABSTRACT: Zourdos, MC, Goldsmith, JA, Helms, ER, Trepeck, C, Halle, JL, Mendez, KM, Cooke, DM, Haischer, MH, Sousa, CA, Klemp, A, and Byrnes, RK. Proximity to failure and total repetitions performed in a set influences accuracy of intraset repetitions in reserve-based rating of perceived exertion. J Strength Cond Res 35(2S): S158-S165, 2021-The aim of this study was to assess the accuracy of predicting repetitions in reserve (RIR) intraset using the RIR-based rating of perceived exertion (RPE) scale. Twenty-five men (age: 25.3 ± 3.3 years, body mass: 89.0 ± 14.7 kg, height: 174.69 ± 6.7 cm, and training age: 4.7 ± 3.2 years) reported to the laboratory. Subjects performed a 1 repetition maximum (1RM) squat followed by one set to failure at 70% of 1RM. During the 70% set, subjects verbally indicated when they believed they were at a 5RPE (5RIR), 7RPE (3RIR), or 9RPE (1RIR), and then continued to failure. The difference between actual repetitions performed and participant-predicted repetitions was calculated as the RIR difference (RIRDIFF). The average load used for the 70% set was 123.10 ± 24.25 kg and the average repetitions performed were 16 ± 4. The RIRDIFF was lower (RPEs were more accurate) closer to failure (RIRDIFF at 9RPE = 2.05 ± 1.73; RIRDIFF at 7RPE = 3.65 ± 2.46; and RIRDIFF at 5RPE = 5.15 ± 2.92 repetitions). There were significant relationships between total repetitions performed and RIRDIFF at 5RPE (r = 0.65, p = 0.001) and 7RPE (r = 0.56, p = 0.004), but not at 9RPE (r = 0.01, p = 0.97). Thus, being farther from failure and performing more repetitions in a set were associated with more inaccurate predictions. Furthermore, a multiple linear regression revealed that more repetitions performed per set was a significant predictor of RIR prediction inaccuracy at the called 5 (p = 0.003) and 7 (p = 0.011) RPEs, while training age (p > 0.05) was not predictive of rating accuracy. These data indicate RIR predictions are improved during low to moderate repetition sets and when there is close proximity to failure.


Assuntos
Esforço Físico , Treinamento Resistido , Adulto , Criança , Pré-Escolar , Humanos , Lactente , Masculino , Percepção , Postura , Levantamento de Peso , Adulto Jovem
2.
Int J Sports Physiol Perform ; 14(4): 540-543, 2019 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-30300064

RESUMO

PURPOSE: To examine the validity of 2 linear position transducers, the Tendo Weightlifting Analyzer System (TWAS) and Open Barbell System (OBS), compared with a criterion device, the Optotrak Certus 3-dimensional motion-capture system (OC3D). METHODS: A total of 25 men (age, 25 [3] y; height, 174.0 [6.7] cm; body mass, 89.0 [14.7] kg; squat 1-repetition maximum [1RM], 175.8 [34.7] kg) with ≥2 y of resistance-training experience completed a back 1RM and 1 set to failure at 70% of 1RM. Average concentric velocity (ACV) and peak concentric velocity (PCV) were recorded by all 3 devices during the final warm-up set, all 1RM attempts, and every repetition during the 70% set. RESULTS: In total, 575 samples were obtained. Bland-Altman plots, mountain plots, a 1-way analysis of variance, SEM, and intraclass correlation coefficients were used to analyze validity. The analysis of variance showed no difference (P = .089) between devices for ACV. However, for PCV, TWAS was significantly different (ie, inaccurate) from OC3D (P < .001) and OBS (P = .001), but OBS was similar (P = .412) to OC3D. For ACV, intraclass correlation coefficients were higher for OBS than for TWAS. Bland-Altman plots showed agreement for ACV for both devices against OC3D but large limits of agreement for PCV for both devices. Mountain plots showed valid ACV for both devices, however, but slightly greater ACV and PCV accuracy with OBS than TWAS. CONCLUSIONS: Both devices may provide valid ACV measurements, but some metrics suggest more accurate ACV with OBS vs TWAS. For PCV, neither device is particularly accurate; however, OBS seems to be more accurate than TWAS.


Assuntos
Treinamento Resistido/instrumentação , Estudos de Tempo e Movimento , Levantamento de Peso , Adulto , Análise de Variância , Interpretação Estatística de Dados , Humanos , Masculino , Movimento , Fotografação , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA