Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Pediatr Cardiol ; 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38951145

RESUMO

After the Fontan procedure, patients require lifelong follow-up due to significant late morbidity and mortality. Thrombocytopenia is seen frequently post-Fontan, likely due to secondary hypersplenism from elevated Fontan pressure. We investigated platelet counts in patients with a Fontan circulation and assessed associations with catheterization data and clinical outcomes. This retrospective study included 92 patients (33% female) post-Fontan who had a complete blood count performed between January 2011 and July 2023. The age at evaluation was 24.0 ± 8.9 years. Outcomes measured included elevated Fontan pressure (≥ 15 mmHg), Fontan-associated liver disease (FALD), unscheduled admissions, transplant, and death. Participants with thrombocytopenia (≤ 150,000/µL) had significantly higher rates of elevated Fontan pressure (OR 8.1, 95% CI 1.3-52.7, p = 0.03), FALD (OR 4.1, 95% CI 1.6-10.6, p = 0.004), and unscheduled admissions (362 ± 577 versus 115 ± 185 admissions per 1000 patient-years, p = 0.02). Thrombocytopenia post-Fontan is associated with elevated Fontan pressure, FALD, and increased morbidity. Platelet count could serve as a non-invasive factor in identifying patients at risk of decompensation.

2.
Pediatr Cardiol ; 44(4): 795-805, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36806971

RESUMO

Data on the frequency and outcome of surgical interventions as a result of adverse events (AE) encountered in the pediatric and congenital cardiac catheterization laboratory are limited. This study analyzes the outcomes of specific types of AE that are most likely to require immediate surgical intervention. Data from the C3PO registry were analyzed to identify specific types of significant vascular/cardiac trauma or technical adverse events (stent/device/coil embolization/migration). The relationship between these AE and an "adverse outcome" (defined as either surgery, ECMO, or death) were analyzed. Between 01/2014 and 12/2017, 25,731 cases were entered into the C3PO registry. Vascular or cardiac trauma were observed in 92 cases (0.36% cases in C3PO), and technical adverse events were observed in 176 cases (0.68% cases in C3PO). The two highest procedure type risk categories (PREDIC3T) accounted for 61% of the cases in the cardiac/vascular trauma cohort, and 34% in the technical AE cohort. For vascular/cardiac trauma, 24 (26%) had an adverse outcome, with ECMO in 8 (9%), surgery in 19 (20%), and death in 9 (10%). For technical AE 25 (14%) had an adverse outcome, with ECMO in 3 (2%), surgery in 23 (13%), and death in 3 (2%). Survival after cardiac surgery secondary to an AE was 68% for cardiac/vascular trauma, and 96% for technical adverse events. RF perforation of the pulmonary valve was the procedure most likely to result in cardiac/vascular trauma (10%), with 57% of those having an adverse outcome. Atrial septal interventions accounted for 29% of all adverse outcomes in the cardiac/vascular trauma cohort. Non-elective or emergent cases were associated with a significantly higher incidence of an adverse outcome for both, cardiac/vascular trauma (OR 7.1) and technical adverse events (OR 2.7). Surgery within the last 30 days was associated with a significantly higher incidence of an adverse outcome for cardiac/vascular trauma only (OR 4.2). Significant cardiac/vascular trauma or stent/device/coil embolization/migration are rare, but high consequence AE. With appropriate surgical and ECMO backup, a high survival can be achieved. The potential need for and impact of immediate surgical backup seems to be higher for cardiac/vascular trauma (in particular after specific case types), than for device/coil migration/embolization, and as such case specific backup arrangements are required.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cardiopatias Congênitas , Valva Pulmonar , Cirurgia Torácica , Criança , Humanos , Cateterismo Cardíaco/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Resultado do Tratamento , Fatores de Risco
3.
Pediatr Cardiol ; 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36454265

RESUMO

There is currently no clear consensus on screening techniques to evaluate the presence or severity of Fontan-associated liver disease (FALD). Cardiac MRI (CMR) is used routinely for post-Fontan surveillance, but CMR-derived measures that relate to the severity of FALD are not yet defined. This was a cross-sectional single-center study of post-Fontan patients who underwent a CMR. CMR exams were re-analyzed by a single pediatric cardiologist. Surrogates of FALD included Gamma-Glutamyl Transferase (GGT), Fibrosis-4 laboratory score (FIB-4), and imaging findings. Findings consistent with cirrhosis on liver ultrasound included increased liver echogenicity and/or nodularity. Statistical analyses were performed to investigate potential relationships between CMR parameters and markers of FALD. Sixty-one patients were included. A larger inferior vena cava cross-sectional area (IVC-CSA) indexed to height was significantly associated with a higher FIB-4 score (Spearman's ρ = 0.28, p = 0.04), a higher GGT level (Spearman's ρ = 0.40, p = 0.02), and findings consistent with cirrhosis on liver ultrasound (OR 1.17, 95% CI: (1.01, 1.35), p = 0.04). None of the other CMR parameters were associated with markers of FALD. A larger indexed IVC-CSA was associated with higher systemic ventricle end-diastolic pressure (EDP) on cardiac catheterization (Spearman's ρ = 0.39, p = 0.018) as well as older age (Spearman's ρ = 0.46, p = < 0.001). Indexed IVC-CSA was the only CMR parameter that was associated with markers of FALD. This measure has the potential to serve as an additional non-invasive tool to improve screening strategies for FALD. Visual abstract summarizing the primary findings of this paper.

4.
Pediatr Cardiol ; 43(3): 596-604, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34743224

RESUMO

The objective of this study was to evaluate the impact of the regular introduction of new technologies into interventional cardiac catheterization procedures, in this case new atrial septal defect (ASD) closure devices, while conducting a multi-center collaborative initiative to reduce radiation usage during all procedures. Data were collected prospectively by 8 C3PO institutions between January 1, 2014 and December 31, 2017 for ASD device closure procedures in the cardiac catheterization lab during a quality improvement (QI) initiative aimed at reducing patient radiation exposure. Radiation exposure was measured in dose area product per body weight (µGy*m2/kg). Use of proposed practice change strategies at the beginning and end of the QI intervention period was assessed. Radiation exposure was summarized by institution and by initial type of device used for closure. This study included 602 ASD device closures. Without changes in patient characteristics, total fluoroscopy duration, or number of digital acquisitions, median radiation exposure decreased from 37 DAP/kg to 14 DAP/kg from 2014 to 2017. While all individual centers decreased overall median DAP/kg, the use of novel devices for ASD closure correlated with a temporary period of worsening institutional radiation exposure and increased fluoroscopy time. The introduction of new ASD closure devices resulted in increased radiation exposure during a QI project designed to reduce radiation exposure. Therefore, outcome assessment must be contextualized in QI projects, hospital evaluation, and public reporting, to acknowledge the expected variation during innovation and introduction of novel therapies.


Assuntos
Comunicação Interatrial , Exposição à Radiação , Dispositivo para Oclusão Septal , Cateterismo Cardíaco/métodos , Fluoroscopia/métodos , Comunicação Interatrial/cirurgia , Humanos , Melhoria de Qualidade , Doses de Radiação , Exposição à Radiação/prevenção & controle , Estudos Retrospectivos , Resultado do Tratamento
5.
Cardiol Young ; 32(12): 1952-1956, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35152927

RESUMO

BACKGROUND: Recurrent laryngeal nerve injury leading to vocal cord paralysis is a known complication of cardiothoracic surgery. Its occurrence during interventional catheterisation procedures has been documented in case reports, but there have been no studies to determine an incidence. OBJECTIVE: To establish the incidence of left recurrent laryngeal nerve injury leading to vocal cord paralysis after left pulmonary artery stenting, patent ductus arteriosus device closure and the combination of the procedures either consecutively or simultaneously. METHODS: Members of the Congenital Cardiovascular Interventional Study Consortium were asked to perform a retrospective analysis to identify cases of recurrent laryngeal nerve injury after the aforementioned procedures. Twelve institutions participated in the analysis. They also contributed the total number of each procedure performed at their respective institutions for statistical purposes. RESULTS: Of the 1337 patients who underwent left pulmonary artery stent placement, six patients (0.45%) had confirmed vocal cord paralysis. 4001 patients underwent patent ductus arteriosus device closure, and two patients (0.05%) developed left vocal cord paralysis. Patients who underwent both left pulmonary artery stent placement and patent ductus arteriosus device closure had the highest incidence of vocal cord paralysis which occurred in 4 of the 26 patients (15.4%). Overall, 92% of affected patients in our study population had resolution of symptoms. CONCLUSION: Recurrent laryngeal nerve injury is a rare complication of left pulmonary artery stent placement or patent ductus arteriosus device closure. However, the incidence is highest in patients undergoing both procedures either consecutively or simultaneously. Additional research is necessary to determine contributing factors that might reduce the risk of recurrent laryngeal nerve injury.


Assuntos
Permeabilidade do Canal Arterial , Traumatismos do Nervo Laríngeo Recorrente , Paralisia das Pregas Vocais , Humanos , Traumatismos do Nervo Laríngeo Recorrente/etiologia , Traumatismos do Nervo Laríngeo Recorrente/complicações , Paralisia das Pregas Vocais/epidemiologia , Paralisia das Pregas Vocais/etiologia , Permeabilidade do Canal Arterial/epidemiologia , Permeabilidade do Canal Arterial/cirurgia , Permeabilidade do Canal Arterial/complicações , Incidência , Estudos Retrospectivos , Cateterismo/efeitos adversos
6.
Pediatr Crit Care Med ; 20(8): 728-736, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30985609

RESUMO

OBJECTIVES: To assess the variation in timing of left atrial decompression and its association with clinical outcomes in pediatric patients supported with venoarterial extracorporeal membrane oxygenation across a multicenter cohort. DESIGN: Multicenter retrospective study. SETTING: Eleven pediatric hospitals within the United States. PATIENTS: Patients less than 18 years on venoarterial extracorporeal membrane oxygenation who underwent left atrial decompression from 2004 to 2016. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: A total of 137 patients (median age, 4.7 yr) were included. Cardiomyopathy was the most common diagnosis (47%). Cardiac arrest (39%) and low cardiac output (50%) were the most common extracorporeal membrane oxygenation indications. Median time to left atrial decompression was 6.2 hours (interquartile range, 3.8-17.2 hr) with the optimal cut-point of greater than or equal to 18 hours for late decompression determined by receiver operating characteristic curve. In univariate analysis, late decompression was associated with longer extracorporeal membrane oxygenation duration (median 8.5 vs 5 d; p = 0.02). In multivariable analysis taking into account clinical confounder and center effects, late decompression remained significantly associated with prolonged extracorporeal membrane oxygenation duration (adjusted odds ratio, 4.4; p = 0.002). Late decompression was also associated with longer duration of mechanical ventilation (adjusted odds ratio, 4.8; p = 0.002). Timing of decompression was not associated with in-hospital survival (p = 0.36) or overall survival (p = 0.42) with median follow-up of 3.2 years. CONCLUSIONS: In this multicenter study of pediatric patients receiving venoarterial extracorporeal membrane oxygenation, late left atrial decompression (≥ 18 hr) was associated with longer duration of extracorporeal membrane oxygenation support and mechanical ventilation. Although no survival benefit was demonstrated, the known morbidities associated with prolonged extracorporeal membrane oxygenation use may justify a recommendation for early left atrial decompression.


Assuntos
Descompressão Cirúrgica/métodos , Oxigenação por Membrana Extracorpórea/métodos , Átrios do Coração/cirurgia , Criança , Pré-Escolar , Descompressão Cirúrgica/mortalidade , Oxigenação por Membrana Extracorpórea/mortalidade , Feminino , Humanos , Lactente , Unidades de Terapia Intensiva Pediátrica/estatística & dados numéricos , Tempo de Internação/estatística & dados numéricos , Masculino , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo
7.
Pediatr Cardiol ; 40(2): 445-453, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30506273

RESUMO

To stratify diverse procedure types into categories with similar radiation exposure in cardiac catheterization for congenital heart disease. Radiation exposures for a comprehensive list of specific procedure types and stratification of outcomes based on radiation risk are not currently available. Data between January 2014 and December 2015 were collected on all cases performed at sites participating in C3PO-QI (Congenital Cardiac Catheterization Outcomes Project-Quality Improvement Initiative) and 9 centers were included. Using expert consensus, 40 unique procedure types were defined by diagnostic characteristics or the intervention(s) performed, and dose area product (DAP) per kilogram of body weight (µGy × m2/kg) was summarized. Using empiric and consensus methods, three radiation risk categories were created. A total of 11,735 cases were included for analysis. Thirteen (n = 7918) procedure types with median DAP/kg < 100 were categorized in the low radiation exposure category (median DAP/kg 39). The medium exposure category (n = 1807) consisted of 16 procedure types with median DAP/kg values ranging 100 to < 200 (overall median DAP/kg 131). Finally, the high radiation exposure category (n = 1073) consisted of 11 procedure types with median DAP/kg ≥ 200 (overall median DAP/kg of 231). The radiation exposure risk categories created in this multi-center dataset are a critical step towards the development of a robust risk adjustment methodology for radiation exposure in catheterization for congenital heart disease.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Fluoroscopia/efeitos adversos , Cardiopatias Congênitas/cirurgia , Exposição à Radiação , Radiografia Intervencionista/efeitos adversos , Adolescente , Criança , Pré-Escolar , Consenso , Humanos , Lactente , Estudos Prospectivos , Melhoria de Qualidade , Doses de Radiação , Medição de Risco/métodos , Fatores de Risco , Adulto Jovem
8.
Catheter Cardiovasc Interv ; 90(2): 281-289, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-28805027

RESUMO

OBJECTIVES: To describe acute and mid-term results of hybrid perventricular device closure of muscular ventricular septal defects (mVSDs). BACKGROUND: Perventricular device closure of mVSDs can mitigate technical limitations of percutaneous closure and need for cardiopulmonary bypass or ventriculotomy with a surgical approach. METHODS: This is a multicenter retrospective cohort study of patients undergoing hybrid perventricular mVSD device closure from 1/2004 to 1/2014. Procedural details, adverse events, outcomes, and follow-up data were collected. Patients were divided into two groups: (1) simple (mVSD closure alone) and (2) complex (mVSD closure with concomitant cardiac surgery). RESULTS: Forty-seven patients (60% female) underwent perventricular mVSD device closure at a median age of 5.2 months (IQR 1.8-8.9) and weight of 5.1 kg (IQR 4.0-6.9). Procedural success was 91% [100% (n = 22) simple and 84% (n = 21/25) complex]. Adverse events occurred in 19% (9/47) [9% (2/22) simple and 28% (7/25) complex]. Hospital length of stay (LOS) was shorter in the simple vs. complex group (4 vs. 14 days, P < 0.01). At mid-term follow-up of 19.2 months (IQR 2.3-43) 90% of pts had complete mVSD closure; none developed late heart block, increased atrioventricular (AV) valve insufficiency or ventricular dysfunction. CONCLUSIONS: Perventricular device closure of simple mVSD was associated with a high rate of procedural success, few adverse events, and short hospital LOS. Procedural adverse events were associated with the presence of concomitant complex surgery. Residual mVSD, AV valve insufficiency, or ventricular dysfunction were uncommon at mid-term follow-up. © 2017 Wiley Periodicals, Inc.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Comunicação Interventricular/terapia , Intervenção Coronária Percutânea/instrumentação , Dispositivo para Oclusão Septal , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Criança , Pré-Escolar , Ecocardiografia Transesofagiana , Feminino , Comunicação Interventricular/diagnóstico por imagem , Humanos , Lactente , Tempo de Internação , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
9.
Catheter Cardiovasc Interv ; 90(2): 269-280, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-28198573

RESUMO

OBJECTIVES: This study sought to update benchmark values to use a quality measure prospectively. BACKGROUND: Congenital Cardiac Catheterization Outcomes Project - Quality Improvement (C3PO-QI), a multi-center registry, defined initial radiation dose benchmarks retrospectively across common interventional procedures. These data facilitated a dose metric endorsed by the American College of Cardiology in 2014. METHODS: Data was collected prospectively by 9 C3PO-QI institutions with complete case capture between 1/1/2014 and 6/30/2015. Radiation was measured in total air kerma (mGy), dose area product (DAP) (µGy*M2 ), DAP per body weight, and fluoroscopy time (min), and reported by age group as median, 75th and 95th %ile for the following six interventional procedures: (1) atrial septal defect closure; (2) aortic valvuloplasty; (3) treatment of coarctation of the aorta; (4) patent ductus arteriosus closure; (5) pulmonary valvuloplasty; and (6) transcatheter pulmonary valve implantation. RESULTS: The study was comprised of 1,680 unique cases meeting inclusion criteria. Radiation doses were lowest for pulmonary valvuloplasty (age <1 yrs, median mGy: 59, DAP: 249) and highest in transcatheter pulmonary valve implantation (age >15 yrs, median mGy: 1835, DAP: 17990). DAP/kg standardized outcome measures across weights within an age group and procedure type significantly more than DAP alone. Radiation doses decreased for all procedures compared to those reported previously by both median and median weight-based percentile curves. These differences in radiation exposure were observed without changes in median fluoroscopy time. CONCLUSIONS: This study updates previously established benchmarks to reflect QI efforts over time. These thresholds can be applied for quality measurement and comparison. © 2017 Wiley Periodicals, Inc.


Assuntos
Benchmarking/normas , Cateterismo Cardíaco/normas , Cardiopatias Congênitas/terapia , Pediatria/normas , Doses de Radiação , Exposição à Radiação/normas , Radiografia Intervencionista/normas , Adolescente , Fatores Etários , Cateterismo Cardíaco/efeitos adversos , Criança , Pré-Escolar , Feminino , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Lactente , Masculino , Segurança do Paciente/normas , Estudos Prospectivos , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista/efeitos adversos , Sistema de Registros , Medição de Risco , Fatores de Risco , Estados Unidos
11.
BMC Health Serv Res ; 17(1): 96, 2017 01 31.
Artigo em Inglês | MEDLINE | ID: mdl-28143468

RESUMO

BACKGROUND: Prior literature identified the use of Performance Measurement Systems (PMS) as crucial in addressing improved processes of care. Moreover, a strategic use of PMS has been found to enhance quality, compared to non-strategic use, although a clear understanding of this linkage is still to be achieved. This paper deals with the test of direct and indirect models related to the link between the strategic use of PMS and the level of improved processes in health care organizations. Indirect models were mediated by the degree of perceived managerial discretion. METHODS: A PLS analysis on a survey of 97 Italian managers working for health care organizations in the Lombardy region was conducted. The response rate was 77.6%. RESULTS: The strategic use of PMS in health care organizations directly and significantly (p < 0.001) enhances performance in terms of improved processes. Perceived managerial discretion is positively and significantly (p < 0.001) affected by the strategic use of PMS, whereas the mediation effect is non-significant. CONCLUSIONS: This study contributes to the literature investigating the design and implementation of a non-financial measurement tool, such as the non-financial information included into a balanced scorecard (BSC), in health care organizations. Managers in health care organizations can benefit from the strategic use of PMS to effectively allocate their time to strategic opportunities and threats, which might arise and affect organizational, output-related performance, such as improving processes.


Assuntos
Pessoal Administrativo/psicologia , Conhecimentos, Atitudes e Prática em Saúde , Indicadores de Qualidade em Assistência à Saúde , Feminino , Humanos , Itália , Masculino , Inquéritos e Questionários
12.
Catheter Cardiovasc Interv ; 86(5): 808-20, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26032565

RESUMO

OBJECTIVE: To describe contemporary outcomes of balloon aortic valvuloplasty (BAVP) performed in 22 US centers. BACKGROUND: BAVP constitutes first-line therapy for congenital aortic stenosis (cAS) in many centers. METHODS: We used prospectively-collected data from two active, multi-institutional, pediatric cardiac catheterization registries. Acute procedural success was defined, for purposes of this review, as a residual peak systolic gradient≤35 mm Hg and no more than mild aortic regurgitation (AR) for patients with isolated cAS. For patients with mixed aortic valve disease, a residual peak systolic gradient≤35 mm Hg without worsening of AR was considered successful outcome. RESULTS: In 373 patients with a median age of 8 months (1 day to 40 years of age) peak systolic gradient had a median of 59 [50, 71] mm Hg pre-BAVP and 22 [15, 30] mm Hg post-BAVP (P<0.001). Procedural success was achieved in 160 patients (71%). The factors independently associated with procedural success were: first time intervention (OR=2.0 (1.0, 4.0) P=0.04), not-prostaglandin dependent, (OR=3.5 (1.5, 8.1); P=0.003), and isolated cAS (absence of AR) (OR=2.1 (1.1-3.9); P=0.03). Twenty percent of patients experienced adverse events, half of which were of high severity. There was no procedural mortality. Neonatal status was the only factor associated with increased risk of high severity adverse events (OR 3.7; 95% CI 1.5-9.0). CONCLUSION: In the current era, BAVP results in procedural success (gradient reduction with minimal increase in AR) in 71% of patients treated at US centers where BAVP is considered first-line therapy relative to surgery.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica , Valvuloplastia com Balão , Adolescente , Adulto , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/congênito , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Distribuição de Qui-Quadrado , Criança , Pré-Escolar , Feminino , Hemodinâmica , Humanos , Lactente , Recém-Nascido , Modelos Logísticos , Masculino , Razão de Chances , Estudos Prospectivos , Recuperação de Função Fisiológica , Sistema de Registros , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Adulto Jovem
13.
Catheter Cardiovasc Interv ; 85(2): 227-33, 2015 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-25257700

RESUMO

BACKGROUND: Secundum atrial septal defect (ASD) closure devices were granted approval based on industry-sponsored, prospective, nonrandomized, single device studies, demonstrating acceptable efficacy and safety in selected patients. We sought to report community practice and outcomes. METHODS AND RESULTS: Procedure specific data was collected on cases considered for ASD closure in the congenital cardiac catheterization project on outcomes (C3PO) between February 1, 2007 and June 31, 2010. Eight centers contributed data during this time period. All adverse events (AE) were independently reviewed and classified by a five level severity scale. In 40 months (2/07-6/10), 653 of 688 ASDs were occluded with a single device using an AMPLATZER(®) Septal Occluder (ASO) in 566 (87%), GORE(®) HELEX(®) Septal Occluder (HSO) in 33 (5%), and a CardioSEAL(®) or STARFlex™ device (CSD) in 54 (8%). Most patients had an isolated ASD (93%). 85% were >2 years of age. The ASD median diameter was 12 mm [8,16] for ASO, with smaller diameters in HSO 8 mm [7,10] and CSD 8 mm [5,10] (P < 0.001). AE (n = 82) were recorded in 76 cases, 11.5% (95% CI 9.2%, 14.1%) and classified as high severity in 4.7% (95% CI 3.2%, 6.5%), with no mortality. A new conduction abnormality was detected during 15 cases and did not resolve in one. Transcatheter device retrieval was possible in 7 of 10 device embolizations. Device erosion occurred in 3 of 566, 0.5% (95% CI 0.1%, 1.5%), ASO implants. CONCLUSION: Although device closure of ASDs is associated with low morbidity and rare mortality, ongoing assessment of device safety profiles are warranted, and registries offer opportunities to facilitate the required surveillance.


Assuntos
Cateterismo Cardíaco/instrumentação , Comunicação Interatrial/terapia , Dispositivo para Oclusão Septal , Adolescente , Cateterismo Cardíaco/efeitos adversos , Criança , Pré-Escolar , Remoção de Dispositivo , Feminino , Migração de Corpo Estranho/etiologia , Migração de Corpo Estranho/terapia , Comunicação Interatrial/diagnóstico , Humanos , Lactente , Masculino , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Adulto Jovem
14.
Pediatr Cardiol ; 36(3): 625-32, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25381624

RESUMO

The aim of the study is to explore the indications for cardiac catheterization while on extracorporeal membrane oxygenation (ECMO) and the various catheter interventions performed as well as assess the safety profile and determine the short- and intermediate-term survival. ECMO is a lifesaving intervention for pediatric patients with respiratory and/or cardiovascular failure. There is limited recent literature discussing the survival and outcomes of patients undergoing cardiac catheterization while on ECMO. A retrospective review of consecutive patients undergoing catheterization while on ECMO from 2004 to 2013 was performed. Thirty-six patients who underwent 40 cardiac catheterizations were identified. Indications for catheterization included hemodynamic/anatomic assessment of postoperative (16) and non-operative patients (7), planned catheter interventions (CI) (12), and cardiomyopathy assessment (5). CI were performed during 18 (45 %) catheterizations, including stenting of vessels/surgical shunts (9), balloon atrial septostomy (4), device closure of septal defects/vessels (3), thrombolysis of vessels (2), endomyocardial biopsy (2), and temporary pacer wire placement (1). Unexpected diagnostic information was found in 21 (52 %), and 13 patients were referred for surgical intervention. Successful decannulation was achieved in 86 % of patients. Survival to discharge was 72 % and intermediate survival was 69 % (median = 29 months). Survival was 88 % (15/17) among patients who underwent CI. There were six procedural complications (15 %); five vascular and one non-vascular. There were no complications related to patient transport. Cardiac catheterization and interventions while on ECMO are safe, with a survival to discharge of 72 %. Diagnostic information obtained from catheterization leads to management decisions which may impact survival.


Assuntos
Cateterismo Cardíaco/métodos , Oxigenação por Membrana Extracorpórea/métodos , Hemodinâmica , Alta do Paciente/estatística & dados numéricos , Complicações Pós-Operatórias/prevenção & controle , Taxa de Sobrevida , Cateterismo Cardíaco/mortalidade , Pré-Escolar , Oxigenação por Membrana Extracorpórea/mortalidade , Feminino , Humanos , Lactente , Masculino , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/mortalidade , Estudos Retrospectivos , Resultado do Tratamento
15.
Ann Thorac Surg ; 116(1): 86-93, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36481325

RESUMO

BACKGROUND: Early postoperative catheterizations (EPOCs) within 6 weeks after a congenital heart surgical procedure can treat residual lesions and provide important clinical information. However, EPOCs are often assumed to impose additional risk on a vulnerable patient population. This study aimed to describe the EPOC population, evaluate procedural safety, compare EPOC patients with procedure-matched non-EPOC patients, and determine risk factors for poor outcomes using data from the Congenital Cardiac Catheterization Project on Outcomes registry. METHODS: In a retrospective cohort, demographic, clinical, and procedural characteristics were analyzed for diagnostic and interventional catheterizations performed in 13 participating institutions from January 2014 to December 2017, excluding patients after heart transplant. The primary outcome was a high-severity adverse event (AE). Three distinct analyses included (1) describing the full cohort and EPOC patients, (2) comparing EPOC patients with and without a high-severity AE, and (3) comparing EPOC patients with controls matched on case type. RESULTS: This study included 17,776 catheterizations, with 1399 EPOCs. The high-severity AE rate was 6.4% overall, 8.9% in the EPOC cohort, and 8.4% in matched controls (P = .74). The association between EPOC status and high-severity AE was not significant in a multivariable model (P = .17). In EPOCs with a high-severity AE, median procedure duration was 30 minutes longer (P < .001), and median time from surgical procedure to catheterization was 3 days longer (P = .05). CONCLUSIONS: EPOC was not associated with additional risk. Individual patient characteristics of size and hemodynamic vulnerability may serve as informative predictors. Timely catheterization may preempt further clinical deterioration, and intraprocedure duration optimization may correlate with improved outcomes.


Assuntos
Cardiopatias Congênitas , Humanos , Estudos Retrospectivos , Cardiopatias Congênitas/diagnóstico , Fatores de Risco , Cateterismo Cardíaco/efeitos adversos , Hemodinâmica
16.
Catheter Cardiovasc Interv ; 80(4): 663-72, 2012 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-22422728

RESUMO

BACKGROUND: Balloon pulmonary valvuloplasty (BPV) is the treatment of choice for patients with pulmonary valve stenosis (PS); however, safety and efficacy outcomes are lacking in the current era. METHODS: Demographic, procedural, and adverse event (AE) data were prospectively collected using a multicenter registry (C3PO) and cases performed between 02/07 and 06/10 at eight institutions. The registry was queried for cases of isolated BPV. Multivariable models were built to determine risk factors for procedure failure and adverse outcomes. RESULTS: 211 cases were included (45%, <1 month). Procedural success was achieved in 91% procedures, being defined as one or more of the following: post-BPV peak systolic valvar gradient to < 25 mm Hg (88%), decrease in gradient by 50% (79%), or reduction of RV/systemic pressure ratio by 50% (45%). Procedural success was more common in neonates, when compared to older patients (96% vs. 87%, P = 0.03). Risk factors for procedural failure included moderate or severe pulmonary valve thickening (OR 2.9, CI 1-8.3), and presence of supravalve PS (OR 9.6, CI 2.7-33.8). Low severity AEs (levels 1-2) occurred in 9% of patients and higher severity AEs (levels 3-5) occurred in 3% of patient; there were no deaths. Risk factors for any AE (levels 1-5) were age below 1 month (OR 3.5, CI 1.3-8.9), as well as operator experience of less than 10 years (OR 3.8, CI 1.5-9.9). CONCLUSIONS: Procedural success is common and AEs, especially higher severity AEs, are rare for BPV in patients with isolated PS. Results have improved considerably when compared to historical data.


Assuntos
Valvuloplastia com Balão , Estenose da Valva Pulmonar/terapia , Fatores Etários , Valvuloplastia com Balão/efeitos adversos , Competência Clínica , Hemodinâmica , Humanos , Lactente , Recém-Nascido , Análise Multivariada , Razão de Chances , Segurança do Paciente , Estudos Prospectivos , Estenose da Valva Pulmonar/diagnóstico , Estenose da Valva Pulmonar/fisiopatologia , Sistema de Registros , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento , Estados Unidos , Função Ventricular Direita
17.
J Am Heart Assoc ; 11(1): e022832, 2022 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-34935425

RESUMO

Background Advancements in the field, including novel procedures and multiple interventions, require an updated approach to accurately assess patient risk. This study aims to modernize patient hemodynamic and procedural risk classification through the creation of risk assessment tools to be used in congenital cardiac catheterization. Methods and Results Data were collected for all cases performed at sites participating in the C3PO (Congenital Cardiac Catheterization Project on Outcomes) multicenter registry. Between January 2014 and December 2017, 23 119 cases were recorded in 13 participating institutions, of which 88% of patients were <18 years of age and 25% <1 year of age; a high-severity adverse event occurred in 1193 (5.2%). Case types were defined by procedure(s) performed and grouped on the basis of association with the outcome, high-severity adverse event. Thirty-four unique case types were determined and stratified into 6 risk categories. Six hemodynamic indicator variables were empirically assessed, and a novel hemodynamic vulnerability score was determined by the frequency of high-severity adverse events. In a multivariable model, case-type risk category (odds ratios for category: 0=0.46, 1=1.00, 2=1.40, 3=2.68, 4=3.64, and 5=5.25; all P≤0.005) and hemodynamic vulnerability score (odds ratio for score: 0=1.00, 1=1.27, 2=1.89, and ≥3=2.03; all P≤0.006) remained independent predictors of patient risk. Conclusions These case-type risk categories and the weighted hemodynamic vulnerability score both serve as independent predictors of patient risk for high-severity adverse events. This contemporary procedure-type risk metric and weighted hemodynamic vulnerability score will improve our understanding of patient and procedural outcomes.


Assuntos
Cardiopatias Congênitas , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/etiologia , Cardiopatias Congênitas/terapia , Hemodinâmica , Humanos , Lactente , Razão de Chances , Sistema de Registros , Medição de Risco , Fatores de Risco
18.
JACC Adv ; 1(5): 100143, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36471862

RESUMO

Background: The COVID-19 pandemic has posed tremendous stress on the health care system. Its effects on pediatric/congenital catheterization program practice and performance have not been described. Objectives: The purpose of this study was to evaluate how case volumes, risk-profile, and outcomes of pediatric/congenital catheterization procedures changed in response to the first wave of COVID-19 and after that wave. Methods: A multicenter retrospective observational study was performed using Congenital Cardiac Catheterization Project on Outcomes Registry (C3PO) data to study changes in volume, case mix, and outcomes (high-severity adverse events [HSAEs]) during the first wave of COVID (March 1, 2020, to May 31, 2020) in comparison to the period prior to (January 1, 2019, to February 28, 2020) and after (June 1, 2020, to December 31, 2020) the first wave. Multivariable analyses adjusting for case type, hemodynamic vulnerability, and age group were performed. Hospital responses to the first wave were captured with an electronic study instrument. Results: During the study period, 12,557 cases were performed at 14 C3PO hospitals (with 8% performed during the first wave of COVID and 32% in the postperiod). Center case volumes decreased from a median 32.1 cases/month (IQR: 20.7-49.0 cases/month) before COVID to 22 cases/month (IQR: 13-31 cases/month) during the first wave (P = 0.001). The proportion of cases with risk factors for HSAE increased during the first wave, specifically proportions of infants and neonates (P < 0.001) and subjects with renal insufficiency (P = 0.02), recent cardiac surgery (P < 0.001), and a higher hemodynamic vulnerability score (P = 0.02). The observed HSAE risk did not change significantly (P = 0.13). In multivariable analyses, odds of HSAE during the first wave of COVID (odds ratio: 0.75) appeared to be lower than that before COVID, but the difference was not significant (P = 0.09). Conclusions: Despite increased case-mix complexity, C3PO programs maintained, if not improved, their performance in terms of HSAE. Exploratory analyses of practice changes may inform future harm-reduction efforts.

19.
Cardiol Young ; 21(2): 153-60, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21138614

RESUMO

OBJECTIVES: In developing countries, congenital heart disease is often unrecognised, leading to serious morbidity and mortality. Guatemala is one of the few developing countries where expert paediatric cardiac treatment is available and affordable, and therefore early detection could significantly improve outcome. We assessed regional congenital heart disease detection rates in Guatemala, and determined whether they correlated with the regional human development index. METHODS: We retrospectively reviewed all new cardiac referrals made in 2006 to the Unidad de Cirugia Cardiovascular Pediatrica, the only paediatric cardiac centre in Guatemala. We calculated regional detection rates by comparing the number of congenital heart disease referrals with the expected incidence using the National Ministry of Health birth data. We then compared the regional detection rates with the human development index data published in the United Nations 2006 Development Program Report using Spearman's rank correlation. RESULTS: An estimated 3935 infants with cardiac defects were born in Guatemala in 2006, an expected 1380 (35%) of whom had severe forms. Overall, only 533 children (14%) with cardiac defects were referred. Of these, 62% had simple shunt lesions, 13% had cyanotic lesions, and 10% had left-sided obstructive lesions. Only 11.5% of referred patients were neonates. Regional detection rates, ranged 3.2-34%, correlated with the regional human development index (r = 0.75, p < 0.0001). CONCLUSIONS: Current detection of congenital heart disease in Guatemala is low and correlates with the regional human development index. Those detected are older and have less severe forms, suggesting a high mortality rate among Guatemalan neonates with complex cardiac defects.


Assuntos
Técnicas de Diagnóstico Cardiovascular/estatística & dados numéricos , Cardiopatias Congênitas/epidemiologia , Pré-Escolar , Guatemala/epidemiologia , Cardiopatias Congênitas/diagnóstico , Humanos , Incidência , Lactente , Recém-Nascido , Prevalência , Estudos Retrospectivos
20.
Circ Cardiovasc Interv ; 13(5): e008172, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32408819

RESUMO

BACKGROUND: The C3PO-QI (Congenital Cardiac Catheterization Project on Outcomes - Quality Improvement), a multicenter registry launched in 2015, instituted quality improvement (QI) initiatives to reduce patient radiation exposure. Through regular collaboration, this initiative would allow for harmony among active participants, maximizing efforts and efficiency at achieving radiation best practices. This study sought to report these efforts with a detailed methodology for which institutions can target initiatives, reducing radiation exposure, and increasing patient safety. METHODS: Data were collected prospectively by 8 C3PO-QI institutions between January 1, 2015 and December 31, 2017. Radiation exposure was measured in dose area product per body weight (dose area product/kg; µGy*m2/kg) and reported by expected radiation exposure categories (REC) and institution for 40 published unique procedure types. Targeted interventions addressing selected strategic domains for radiation reduction were implemented in the pediatric catheterization labs of the C3PO-QI institutions. RESULTS: The study consisted of 15 257 unique cases. Median exposure (dose area product/kg) was decreased by 30% for all procedures. Dose area product/kg was reduced in all 3 REC, with the greatest improvement observed in REC I (REC I, -37%; REC II, -23%; REC III, -27%). Although the baseline radiation exposures and exact percent decrease varied across all C3PO-QI sites, each institution demonstrated improvements in radiation dose over time. These improvements occurred with the implementation of institution-specific QI interventions accelerated by participation in the C3PO-QI multicenter collaborative. CONCLUSIONS: Substantial radiation dose reductions can be achieved using targeted QI methodology and interventions. Participation in a multicenter QI collaborative may accelerate improvement across all centers due to enhanced engagement and shared learning between sites.


Assuntos
Cateterismo Cardíaco , Angiografia Coronária , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/terapia , Doses de Radiação , Exposição à Radiação/prevenção & controle , Lesões por Radiação/prevenção & controle , Proteção Radiológica , Adolescente , Adulto , Cateterismo Cardíaco/efeitos adversos , Criança , Pré-Escolar , Angiografia Coronária/efeitos adversos , Bases de Dados Factuais , Feminino , Disparidades em Assistência à Saúde , Humanos , Lactente , Masculino , Segurança do Paciente , Estudos Prospectivos , Melhoria de Qualidade , Indicadores de Qualidade em Assistência à Saúde , Exposição à Radiação/efeitos adversos , Lesões por Radiação/etiologia , Medição de Risco , Fatores de Risco , Fatores de Tempo , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA