Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Circ J ; 85(11): 1959-1968, 2021 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-34234051

RESUMO

BACKGROUND: Stent edge-related restenosis (SER) remains a potential limitation of drug-eluting stent (DES). Hinge motion at the stent edge could lead to mechanical stress and contribute to incidents of SER. We investigated the effect of hinge motion on SER after implantation of current-generation DES in the right coronary artery (RCA), where excessive vessel movement is commonly observed.Methods and Results:Of 647 consecutive lesions in the RCA treated with second-generation or later DESs, 426 with follow-up angiography were included in this study. Intravascular imaging analysis was performed for 584 stent edges and reference segments. Binary restenosis occurred in 42 lesions (9.9%), and 55% were SERs. The hinge angle was significantly larger in the SER group than in the other restenosis or the no-restenosis group (17.9° vs. 11.6° and 10.6°, respectively; P<0.001). Lesions with an excessive hinge angle (>11.5°) had an increased rate of target lesion revascularization (19.1% vs. 7.2%; P<0.001) during the median follow-up period of 1,578 days. In per-edge analysis, hinge angle and residual plaque burden were independent predictors of SER. The coexistence of excessive hinge motion and residual plaque burden had a synergistic effect on stenotic progression in quantitative angiographic analysis (Pinteraction<0.001) at follow-up angiography. CONCLUSIONS: Substantial stress determined by angulation at a stent edge and its interaction with residual plaque can be considered as one plausible mechanism for SER.


Assuntos
Reestenose Coronária , Stents Farmacológicos , Intervenção Coronária Percutânea , Placa Aterosclerótica , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos/efeitos adversos , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento
2.
Artigo em Japonês | MEDLINE | ID: mdl-32074530

RESUMO

Japanese Diagnostic Reference Levels (DRLs) were released as "Japan DRLs 2015" from Japan Network for Research and Information on Medical Exposure (J-RIME) in June 2015. In "Japan DRLs 2015", DRLs in angiography and interventional procedures are set at a fluoroscopic dose rate of 20 mGy/min at the interventional reference point using a phantom. In order to achieve optimization with DRLs, then it need to be revised regularly. Therefore, we (research group to examine the effect of Japan DRLs 2015 and the necessity of additional items in angiography and vascular interventions) examined the effects of "Japan DRLs 2015" on angiography and interventional procedures. And we also investigated for DRLs revision in the future. As a result, it turned out that it is important to create DRLs in medical procedures that can be effectively used in clinical settings.


Assuntos
Angiografia , Imagens de Fantasmas , Humanos , Japão , Doses de Radiação , Valores de Referência
3.
Artigo em Japonês | MEDLINE | ID: mdl-32963140

RESUMO

It is important to optimize the exposure dose when conducting interventional radiology, but optimization is difficult for medical centers to achieve independently. In 2005, we administered a questionnaire on the measurement of dose rates and awareness of exposure reduction when performing percutaneous coronary intervention. Ten years later, we conducted a follow-up survey of the same 31 centers to determine the current situation and identify trends. The results of the survey showed that the mean fluoroscopy dose rate decreased to 55% of the 2005 value, from 28.2 to 15.6 mGy/min, and the mean radiography dose rate decreased to 71% of the 2005 value, from 4.2 to 3.0 mGy/s. Dose rates for both fluoroscopy and radiography decreased by 84% of facilities. The results also indicated greater cooperation by physicians compared to 10 years ago. In particular, there was a considerable increase in the exchange of ideas with physicians regarding exposure, suggesting a stronger level of interest in exposure. The overall score for questionnaire items was 33% higher than that in the previous survey. These results show that in the past 10 years, awareness of exposure reduction has improved, and dose optimization has been a major factor in the downward trend in dose rates in radiography and fluoroscopy.


Assuntos
Intervenção Coronária Percutânea , Radiografia Intervencionista , Angiografia Coronária , Fluoroscopia , Seguimentos , Doses de Radiação , Inquéritos e Questionários , Raios X
4.
Artigo em Japonês | MEDLINE | ID: mdl-32684564

RESUMO

We conducted a nationwide survey of multiple institutions and collected data of various interventional procedures in the field of cardiology. Included in the analysis were 126 institutions, 381 X-ray systems, and 805 protocols. The dose values were compared with the Japanese diagnostic reference levels (DRLs) 2015. Fluoroscopy time, air kerma at the patient entrance reference point (Ka, r), and air kerma-area product (PKA ) were analyzed for various interventional procedures in 5,734 cardiology patients. The fluoroscopic dose rate (FDR) for pulmonary vein isolation (PVI) was less than half that of the 75th percentile of the Japanese DRLs 2015. The 75th percentiles of fluoroscopy time, Ka, r, and PKA for the respective interventional procedures were as follows: 11.0 min, 735 mGy, and 64 Gyï½¥cm2 for diagnostic coronary angiography (CA); 13.2 min, 839 mGy, and 75 Gyï½¥cm2 for CA + left ventriculography; 34.4 min, 1,810 mGy, and 148 Gyï½¥cm2 for percutaneous coronary intervention (PCI) excluding chronic total occlusion; 80.1 min, 4,338 mGy, and 312 Gyï½¥cm2 for PCI for chronic total occlusion; 74.4 min, 833 mGy, and 90 Gyï½¥cm2 for PVI; and 34.0 min, 795 mGy, and 94 Gyï½¥cm2 for transcatheter aortic valve implantation, respectively. In assessing dose values in interventional radiology, the difficulty of the technique needs to be considered, and the DRL values for FDR, fluoroscopic time, Ka, r, and PKA for each interventional procedure are considered necessary when reassessing or updating DRLs.


Assuntos
Intervenção Coronária Percutânea , Angiografia Coronária , Fluoroscopia , Humanos , Doses de Radiação , Radiografia Intervencionista , Inquéritos e Questionários
5.
Artigo em Japonês | MEDLINE | ID: mdl-31956188

RESUMO

PURPOSE: It is very important to manage the radiation dose of cardiovascular interventional (CVI) procedures. Overseas, the diagnostic reference levels for cardiac interventional procedures were established with the air kerma at the patient entrance reference point (Ka,r) and the air kerma-area product (PKA). Although the Japan DRLs 2015 was established by the Japan Network for Research and Information on Medical Exposure (J-RIME), the Japan DRL for CVIs were established by fluoroscopic dose rates of 20 mGy/min at the patient entrance reference point with 20 cm thickness polymethyl methacrylate (PMMA) phantom. In the present our study, we performed a questionnaire survey of indicated values of angiographic parameters in CVI procedures. METHODS: A nationwide questionnaire was sent by post to 765 facilities. Question focused on angiographic technology, exposure parameters and radiation doses as the displayed dosimetric parameters on the angiographic machine. RESULTS: The recovery rate was 22.8% at 175 out of 765 facilities. In total 1728 cases of the coronary angiography (CAG), 1703 cases of the percutaneous coronary intervention (PCI), 962 cases of the radiofrequency catheter ablation (RFCA) and 377 cases of pediatric CVI. The 75th percentile value of Ka,r, PKA, fluoroscopy time (FT) and number of cine images (CI) for CAG, PCI, RFCA and pediatric CVI were 702, 2042, 644, and 159 mGy, respectively, 59.3, 152, 81.3, and 14.9 Gy・cm2, respectively, 10.2, 35.6, 61.1, and 35.6 min, respectively and 1503, 2672, 722, and 2378 images, respectively. Our investigation showed that the angiographic parameters were different in several CVI procedures. CONCLUSIONS: The displayed dosimetric parameters on the angiographic machine in CVI procedures showed different values. We should classify the dosimetric parameters for each procedure.


Assuntos
Intervenção Coronária Percutânea , Doses de Radiação , Exposição à Radiação , Criança , Fluoroscopia , Humanos , Japão , Radiografia Intervencionista , Inquéritos e Questionários
6.
Artigo em Japonês | MEDLINE | ID: mdl-31327775

RESUMO

PURPOSE: We conducted a multicenter study to investigate the current status of difference between the actual values at the patient entrance reference point (PERP) and display air kerma. METHODS: We exposure dose and fluoroscopy dose were measured by 32 apparatuses at 32 member institutions of the Japanese Society of Circulation Imaging Technology (CITEC) under unified conditions, and the actual measured values and display air kerma were compared. We entrance doses during fluoroscopy and imaging were measured at the PERP, with focus detector distance (FDD) 110 cm, a copper plate of 3.5 mm in thickness adhered to the front face of flat panel detector (FPD) as absorber, field-of-view (FOV) 18 cm, and the frame rate of 15 f/s, excluding the bed. Display air kerma were recorded at the same time. JIS (Z 4751-2-43: 2012) specify "The reference air kerma rate and the cumulative reference air kerma shall not deviate from their respective display air kerma by more than ±35% over the range of 6 mGy/min and 100 mGy to the maximum value." The number of apparatuses display air kerma deviated from this condition and its percentage were obtained. RESULTS: The mean difference percentage between actual measured values and display air kerma in 32 apparatuses was approximately 15.6%, with some apparatuses showing substantially different display air kerma. CONCLUSION: In order to estimate patients' skin exposure dose from display air kerma more accurately, it is necessary to perform calibration of the apparatus by regular dose measurement or convert values.


Assuntos
Raios X , Calibragem , Fluoroscopia , Humanos , Doses de Radiação , Radiografia , Inquéritos e Questionários
7.
Artigo em Japonês | MEDLINE | ID: mdl-28111398

RESUMO

During percutaneous coronary intervention (PCI) for chronic total occlusion (CTO), longer fluoroscopic time as compared with PCI for non-CTO lesions may cause skin injury by increased radiation. We have performed a multi-center observational study comparing the exposed dose during the PCI of CTO (CTO group) and during the PCI of non-CTO lesions (non-CTO group). Exposure doses were assessed in 313 patients with CTO and 3,310 patients with non-CTO lesions. Total fluoroscopy time (59.0 ±35.5 vs 26.8 ±18.8 min, p<0.0001) and the total air kerma (2.76±2.11 vs 1.27±0.94 Gy, p<0.0001) were significantly greater in the CTO group than in the non-CTO group. The maximum air kerma of the CTO group was 13.62 Gy. Informed consent about the risk of transient depilation and the transient erythema is required for the case with radiation dose over 3 Gy. The frequency of the patient who received radiation >3 Gy was significantly higher in the CTO group as compared with the non-CTO group (34.1% vs 4.9%). Therefore, informed consent before an operation and postoperative follow-up are indispensable for the performed PCI of CTO. Moreover, comprehensive understanding of the exposure dose during operation and to record the final exposure dose may be extremely important for the radiological technologists.


Assuntos
Estenose Coronária/diagnóstico por imagem , Intervenção Coronária Percutânea/métodos , Doença Crônica , Humanos , Doses de Radiação
8.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 72(1): 73-81, 2016 Jan.
Artigo em Japonês | MEDLINE | ID: mdl-26796936

RESUMO

Deterministic effects have been reported in cardiac interventional procedures. To prevent radiation skin injuries in percutaneous coronary intervention (PCI), it is necessary to measure accurate patient entrance skin dose (ESD) and maximum skin absorbed dose (MSD). We measured the MSD on 62 patients in four facilities by using the Chest-RADIREC(Ⓡ) system. The correlation between MSD and fluoroscopic time, dose area product (DAP), and cumulative air kerma (AK) showed good results, with the correlation between MSD and AK being the strongest. The regression lines using MSD as an outcome value (y) and AK as predictor variables (x) was y=1.18x (R(2)=0.787). From the linear regression equation, MSD is estimated to be about 1.18 times that of AK in real time. The Japan diagnostic reference levels (DRLs) 2015 for IVR was established by the use of dose rates using acrylic plates (20- cm thick) at the interventional reference point. Preliminary reference levels proposed by International Atomic Energy Agency (IAEA) were provided using DAP. In this study, AK showed good correlation most of all. Hence we think that Japanese DRLs for IVR should reconsider by clinical patients' exposure dose such as AK.


Assuntos
Intervenção Coronária Percutânea , Doses de Radiação , Radiometria/métodos , Pele/efeitos da radiação , Humanos
9.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 71(4): 348-55, 2015 Apr.
Artigo em Japonês | MEDLINE | ID: mdl-25892422

RESUMO

This is the eighth investigation which has been carried out every 5 years since 1974 for the purpose of grasping the trend of X-ray devices and the radiographic condition. We gathered it up mainly on a radiographic condition, in this report. As for the chest radiography and double contrast gastrography, introduction of the flat panel detector (FPD) advanced in comparison with the last survey. Ratio of the imaging system at chest radiography was 65% for computed radiography (CR), 33% for FPD, 1% for screen/film (S/F), and 1% for others. The radiographic condition of FPD was current time product less than CR. Ratio of the imaging system at gastrography was 3% for CR, 48% for FPD, 34% for image intensifier-digital radiography (I.I.-DR), and 15% for S/F. The tube voltage and the exposure time were similar to the last survey time, but the tube current became lower. Through this survey, the change of the radiographic condition was seen in the radiography part where introduction of the FPD advanced. We think the continuous survey is necessary in future.


Assuntos
Intensificação de Imagem Radiográfica/instrumentação , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Inquéritos e Questionários
10.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 71(12): 1241-7, 2015 Dec.
Artigo em Japonês | MEDLINE | ID: mdl-26685837

RESUMO

Although measurement and management of angiographic entrance skin dose (ESD) are deemed extremely important, accurate determination of maximum ESD and its location is generally difficult because of the dependence on therapeutic technique and position. Following our development of body-mounted gear bearing radiophotoluminescence glass dosimeter (RPLD) arrays for direct measurement of ESD in cranial and cardiovascular angiography and interventional radiology (IVR), our focus next turned to the limited number of facilities equipped to read RPLD outputs and the need for methods to effectively provide feedback to clinical facilities. As described here, we first constructed an RPLD reading facility capable of sending and receiving RPLDs by post, offering the potential to enable utilization of the developed gear at all hospitals in Japan that perform angiography and IVR. We next developed specialized web-based system to generate dose maps from RPLD dose data, thereby enabling any facility to perform trial system analysis, evaluation, and implementation; and investigated the results and related problems.


Assuntos
Doses de Radiação , Radiografia Intervencionista , Angiografia , Retroalimentação , Humanos , Japão , Serviço Hospitalar de Radiologia , Radiometria , Pesquisa
11.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 70(8): 814-20, 2014 Aug.
Artigo em Japonês | MEDLINE | ID: mdl-25142393

RESUMO

In recent years, dose justification and optimization have been attempted in percutaneous coronary intervention (PCI); however, deterministic effects have been reported. To prevent radiation skin injuries in PCI, it is necessary to measure the patient entrance skin dose (ESD), but an accurate dose measurement method has not yet been established. In this study, we developed a dosimetry gown that can measure the ESD during PCI using multiple radiophotoluminescence dosimeters (RPLDs). The RPLDs were placed into 84 pockets that were sewn into a dosimetry gown. Patients wear the original dosimetry gown during the procedures, after which we obtain accurate ESD measurements. We believe that this method using RPLDs and a newly-designed dosimetry gown provides accurate ESD measurements during PCI. We expect this system to become a standard method for measuring ESD during PCI.


Assuntos
Intervenção Coronária Percutânea , Doses de Radiação , Radiometria/instrumentação , Desenho de Equipamento , Vidro , Humanos , Medições Luminescentes/instrumentação , Imagens de Fantasmas , Lesões por Radiação/prevenção & controle , Radiometria/métodos , Pele
12.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 69(4): 371-9, 2013 Apr.
Artigo em Japonês | MEDLINE | ID: mdl-23609858

RESUMO

We report here the results of a dose evaluation based on information obtained in a 2011 questionnaire as compared with an investigation made in 2007. Briefly, in general radiography, the dose used in most examinations in 2011 was lower than in 2007. However, since the entrance surface dose for chest X-rays showed an increase, there is a need to standardize the taking of digital images to be able to decrease the dose. Although computed tomography dose index volume (CTDIvol) in CT examinations was higher than that revealed in the 2007 investigation, there is potential for dose reduction.


Assuntos
Doses de Radiação , Radiografia , Adulto , Criança , Humanos , Inquéritos e Questionários , Tomografia Computadorizada por Raios X
13.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 69(12): 1353-62, 2013 Dec.
Artigo em Japonês | MEDLINE | ID: mdl-24366555

RESUMO

In order to promote consensus building on decommissioning operation rules for medical linear accelerators in Japan, we carried out a risk communication (RC) approach mainly providing knowledge for maintenance staff regarding induced radioactivity. In February 2012, we created a booklet (26 pages) to present an overview of the amended law, the mechanism and the distribution of induced radioactivity showing the actual radiation dose rate around a linear accelerator and actual exposure doses to staff. In addition, we co-sponsored a seminar for workers in this field organized by the Japan Medical Imaging and Radiological Systems Industries Association to explain the contents of this booklet, and answer questions regarding induced radioactivity of linear accelerators as an RC program. As a result, the understanding of staff regarding the regulations on maximum X-ray energy on linear accelerators (P<0.05), and the outline of clearance systems (P<0.01), were facilitated by RC. In addition, we found that about 70% of maintenance staff considered that the cooling time for decommissioning operation depended on the situation. Our RC approach suggests that consensus building should be used to make rules on decommissioning operations for linear medical accelerators.


Assuntos
Comunicação , Aceleradores de Partículas , Recursos Humanos em Hospital , Proteção Radiológica/métodos , Gestão de Riscos/métodos , Humanos , Exposição Ocupacional , Folhetos , Doses de Radiação , Serviço Hospitalar de Radiologia
14.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 69(3): 278-83, 2013 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-23514856

RESUMO

Decay-in-storage for radioactive waste including that of nuclear medicine has not been implemented in Japan. Therefore, all medical radioactive waste is collected and stored at the Japan Radioisotope Association Takizawa laboratory, even if the radioactivity has already decayed out. To clarify the current situation between Takizawa village and Takizawa laboratory, we investigated the radiation management status and risk communication activities at the laboratory via a questionnaire and site visiting survey in June 2010. Takizawa laboratory continues to maintain an interactive relationship with local residents. As a result, Takizawa village permitted the acceptance of new medical radioactive waste containing Sr-89 and Y-90. However, the village did not accept any non-medical radioactive waste such as waste from research laboratories. To implement decay-in-storage in Japan, it is important to obtain agreement with all stakeholders. We must continue to exert sincere efforts to acquire the trust of all stakeholders.


Assuntos
Comunicação , Eliminação de Resíduos de Serviços de Saúde , Resíduos Radioativos , Japão , Eliminação de Resíduos de Serviços de Saúde/métodos , Inquéritos e Questionários
15.
Radiat Prot Dosimetry ; 199(10): 1082-1089, 2023 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-37092251

RESUMO

To propose reference values for air-kerma at the reference point (Ka,r), air-kerma area product (PKA), fluoroscopy time (FT) and number of cine images (CI) for four age groups in Japan, a nationwide questionnaire was posted to 132 pediatric catheterisation of certified facility in Japan, using the conventional post system, to which 43 facilities responded. For diagnostic cardiac angiography, reference values were as follows: Ka,r: 86, 102, 165 and 264 mGy; PKA: 9.3, 9.5, 16 and 34 Gy.cm2; FT: 33, 29, 26 and 30 min and CI: 1904, 1966, 2405 and 1871 images. For therapeutic cardiac angiography, reference values were as follows: Ka,r: 107, 163, 103 and 202 mGy; PKA: 7.5, 18, 7 and 24 Gy.cm2; FT: 56, 52, 42 and 30 min and CI: 3886, 3232, 2212 and 4316 images for less than 1, 1-5, 6-10 and 11-15 y, respectively. To optimal patient exposure from diagnostic and therapeutic cardiac catheterisation, it is therefore necessary to establish reference values for pediatric cardiac catheterisation examinations for four age groups.


Assuntos
Cateterismo Cardíaco , Radiografia Intervencionista , Humanos , Criança , Doses de Radiação , Japão , Inquéritos e Questionários , Fluoroscopia
18.
Artigo em Japonês | MEDLINE | ID: mdl-23001274

RESUMO

We carried out a questionnaire survey to research on radiographic conditions in 3000 institutes. We discussed on radiographic conditions to estimate patient exposures. The collection rate was 24.7%. Most of the institutes shifted to the use of high-voltage generator, digital devices, and filmless equipment. We did not see a shift in this survey of radiographic conditions compared with the 2007 survey.


Assuntos
Doses de Radiação , Radiografia , Humanos , Japão , Radiografia/instrumentação , Inquéritos e Questionários
19.
Radiat Prot Dosimetry ; 198(1-2): 16-22, 2022 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-35021232

RESUMO

To propose typical values for the arrhythmia region between pulmonary vein isolation (PVI) and nonpulmonary vein isolation (non-PVI) in Japan. A nationwide questionnaire was posted to 343 facilities, to which 125 facilities (36.4%) responded. Results is the median for PVI and non-PVI were in terms of Ka,r (317 and 196 mGy), PKA (40.8 and 26.3 Gy.cm2), FT (43.0 and 27.3 min), and CI (326 and 102 images). When comparing PVI and non-PVI procedures, there were significant differences in Ka, r, PKA, FT, and CI (p < 0.05). In other words, by classifying into two types, PVI and non-PVI, we contributed to the establishment of typical values in Japan's RFCA.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Exposição à Radiação , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Humanos , Japão , Veias Pulmonares/cirurgia , Inquéritos e Questionários , Resultado do Tratamento
20.
J Neuroendovasc Ther ; 16(7): 354-360, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-37502341

RESUMO

Objective: To meet the new standard of the annual dose limit for the eye lens recommended by the International Commission on Radiation Protection, radiation doses of neuroendovascular procedures in Japanese institutions were investigated. Methods: Radiation doses to operators involved in 304 neuroendovascular procedures at 30 Japanese institutions were prospectively surveyed. The institutions recruited at an annual meeting of the Japanese Society for Neuroendovascular Therapy participated voluntarily. A maximum of 10 wireless dosimeters were attached to the radiation protection (RP) goggles, the ceiling-mounted RP shielding screen, and the operators' forehead and neck over the protective clothing. Doses recorded inside the goggles were defined as eye lens doses for operators who wore RP goggles, while doses to the forehead were defined as eye lens doses for those who did not. The shielding effect rates of the protection devices were calculated, and statistical analysis was performed for the comparison of radiation doses. Results: From 296 analyzed cases, mean eye lens radiation doses per procedure were 0.088 mGy for the left eye and 0.041 mGy for the right eye. For the left eye, that dose without RP equipment was 0.176 mGy and that with RP goggles plus an RP shielding screen was 0.034 mGy. Four parameters, including left eye dose, air kerma at the patient entrance reference point, fluoroscopic time, and the total number of frames, were assessed for five types of neurovascular procedures. Of them, transarterial embolization for dural arteriovenous fistula was associated with the highest eye lens dose at 0.138 mGy. The shielding effect rates of protection goggles were 60% for the left and 55% for the right RP goggle. The mean doses to the inner and outer surfaces of the RP shielding screen were 0.831 mGy and 0.040 mGy, respectively, amounting to a shielding effect rate of 95%. Conclusion: To meet the new standard, both RP goggles and RP shielding screens are strongly recommended to be used effectively. Without proper use of radiological protection devices, the number of neuroendovascular procedures that one operator performs per year will be limited under the new guideline.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA