Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Medicina (Kaunas) ; 60(2)2024 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-38399623

RESUMO

Background and Objectives: The nature of multilevel lead-related venous stenosis/occlusion (MLVSO) and its influence on transvenous lead extraction (TLE) as well as long-term survival remains poorly understood. Materials and Methods: A total of 3002 venograms obtained before a TLE were analyzed to identify the risk factors for MLVSO, as well as the procedure effectiveness and long-term survival. Results: An older patient age at the first system implantation (OR = 1.015; p < 0.001), the number of leads in the heart (OR = 1.556; p < 0.001), the placement of the coronary sinus (CS) lead (OR = 1.270; p = 0.027), leads on both sides of the chest (OR = 7.203; p < 0.001), and a previous device upgrade or downgrade with lead abandonment (OR = 2.298; p < 0.001) were the strongest predictors of MLVSO. Conclusions: The presence of MLVSO predisposes patients with cardiac implantable electronic devices (CIED) to the development of infectious complications. Patients with multiple narrowed veins are likely to undergo longer and more complex procedures with complications, and the rates of clinical and procedural success are lower in this group. Long-term survival after a TLE is similar in patients with MLVSO and those without venous obstruction. MLVSO probably better depicts the severity of global venous obstruction than the degree of vein narrowing at only one point.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Doenças Vasculares , Humanos , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Coração , Fatores de Risco , Constrição Patológica , Resultado do Tratamento , Estudos Retrospectivos
2.
Circ J ; 87(7): 990-999, 2023 06 23.
Artigo em Inglês | MEDLINE | ID: mdl-36517020

RESUMO

BACKGROUND: Cardiac implantable electronic devices (CIED) are very rare in the pediatric population. In children with CIED, transvenous lead extraction (TLE) is often necessary. The course and effects of TLE in children are different than in adults. Thus, this study determined the differences and specific characteristics of TLE in children vs. adults.Methods and Results: A post hoc analysis of TLE data in 63 children (age ≤18 years) and 2,659 adults (age ≥40 years) was performed. The 2 groups were compared with respect to risk factors, procedure complexity, and effectiveness. In children, the predominant pacing mode was a single chamber ventricular system and lead dysfunction was the main indication for lead extraction. The mean implant duration before TLE was longer in children (P=0.03), but the dwell time of the oldest extracted lead did not differ significantly between adults and children. The duration (P=0.006) and mean extraction time per lead (P<0.001) were longer in children, with more technical difficulties during TLE in the pediatric group (P<0.001). Major complications were more common, albeit not significantly, in children. Complete radiographic and procedural success were significantly lower in children (P<0.001). CONCLUSIONS: TLE in children is frequently more complex, time consuming, and arduous, and procedural success is more often lower. This is related to the formation of strong fibrous tissue surrounding the leads in pediatric patients.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Adulto , Criança , Adolescente , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Remoção de Dispositivo/métodos , Fatores de Risco , Coração , Resultado do Tratamento , Estudos Retrospectivos
3.
Pediatr Cardiol ; 2023 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-37898588

RESUMO

The best strategy for lead management in children is a matter of debate, and our experiences are limited. This is a retrospective single-center study comparing difficulties and outcomes of transvenous lead extraction (TLE) implanted ich childhood and at age < 19 years (childhood-implanted-childhood-extracted, CICE) and at age < 19 (childhood-implanted-adulthood-extracted, CIAE). CICE patients-71 children (mean age 15.1 years) as compared to CIAE patients (114 adults (mean age 28.61 years) were more likely to have VVI than DDD pacemakers. Differences in implant duration (7.96 vs 14.08 years) appeared to be most important, but procedure complexity and outcomes also differed between the groups. Young adults with cardiac implantable electronic device implanted in childhood had more risk factors for major complications and underwent more complex procedures compared to children. Implant duration was significantly longer in CIAE patients than in children, being the most important factor that had an impact on patient safety and procedure complexity. CIAE patients were more likely to have prolonged operative duration and more complex procedures due to technical problems, and they were 2-3 times more likely to require second-line or advanced tools compared to children, but the rates of clinical and procedural success were comparable in both groups. The difference between the incidence of major complications between CICE and CIAE patients is very clear (MC 2.9 vs 7.0%, hemopericardium 1.4 vs 5.3% etc.), although statistically insignificant. Delay of lead extraction to adulthood seems to be a riskier option than planned TLE in children before growing up.

4.
J Cardiovasc Electrophysiol ; 33(12): 2625-2639, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36054327

RESUMO

INTRODUCTION: Cardiac tamponade (CT) is one of the most common and dangerous complications of transvenous lead extraction (TLE). So far, however, there has been little discussion about the problem. METHODS: We analyzed the occurrence of CT in a group of 1226 patients undergoing TLE at a single reference center between June, 2015 and February, 2021. Using standard mechanical devices as first-line tools, a total of 2092 leads had been extracted. RESULTS: CT occurred in 18 patients (1.47%): due to injury to the wall of the right atrium in 14 patients (1.14%) and other cardiac walls in four patients (0.33%). Younger patient age at first implantation, female gender, high left ventricular ejection fraction (LVEF), lower New York Heart Association class, low Charlson comorbidity index, longer implant duration, and the number of previous procedures related to cardiac implantable electronic devices (CIED) are important patient-related risk factors for CT. Significant procedure-related risk factors include the number of extracted leads, extraction of atrial leads and longer dwell time of extracted leads. Intraoperative transoesophageal echocardiography (TEE) provides a lot of information about pulling on various cardiac structures and is able to detect a very early phase of bleeding to the pericardial sac. As a result of implementing best practices guidance in performing extraction procedures and close collaboration with cardiac surgeons that allowed immediate rescue intervention in our series of 18 CT cases, there were no procedure-related deaths (mortality 0%). CONCLUSIONS: The need for rescue surgery due to CT has no influence on clinical and procedural success. Early diagnosed (TEE monitoring) and properly managed CT does not generate any additional risk in short- and long-term follow-up after TLE.


Assuntos
Tamponamento Cardíaco , Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Feminino , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Falha de Equipamento , Tamponamento Cardíaco/diagnóstico por imagem , Tamponamento Cardíaco/etiologia , Tamponamento Cardíaco/terapia , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Estudos Retrospectivos , Marca-Passo Artificial/efeitos adversos
5.
J Cardiovasc Electrophysiol ; 33(7): 1357-1365, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35474258

RESUMO

INTRODUCTION: The professional society guidelines recommend that transvenous lead extraction (TLE) operating teams collaborate closely with cardiac surgeons in the management of life-threatening complications. METHODS: We assessed the role of cardiac surgeons participating in 3462 TLE procedures at a high-volume center between 2006 and 2021. The roles for cardiac surgery in TLE can be categorized into five areas: emergency surgical interventions for the management of cardiac laceration and severe bleeding (1.184%), cardiac surgery complementing partially successful TLE or vegetation removal (0.693%), delayed surgical treatment of TLE-related tricuspid valve dysfunction (0.751%), epicardial pacemaker implantation through sternotomy during emergency, complementing or delayed surgical interventions (0.607%), and delayed epicardial lead implantation (0.491%). RESULTS: Isolated damage to the wall of the right atrium was the most common cause of cardiac tamponade (53.66% of emergency surgeries) followed by injury to the right ventricle and vena cava (both 7.317%). CONCLUSIONS: Emergency cardiac surgery for the management of severe hemorrhagic complications is still the most common treatment option. The remaining areas include surgery complementing partially successful TLE: repair of tricuspid valve or epicardial ventricular lead placement to achieve permanent cardiac resynchronization. The experience at a single high-volume TLE center indicates the necessity of close collaboration with the cardiac surgeons whose roles appear broader than the mere surgical standby. Mortality in patients who survived cardiac surgery during TLE does not differ from the survival of other patients after TLE without complications requiring surgical intervention.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Cirurgiões , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Humanos , Estudos Retrospectivos , Resultado do Tratamento
6.
Echocardiography ; 37(4): 601-611, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32154950

RESUMO

AIMS: The usefulness of transesophageal echocardiographic (TEE) monitoring for transvenous lead extraction (TLE) procedures is still controversial. The purpose of the current study was to present new TEE values in detecting invisible events in fluoroscopy and preventing the development of dangerous complications. METHODS: From 2015 to 2019, a total of 1026 procedures were performed in single TLE center. In total, 1108 leads had been extracted with a mean lead dwell time of 115.8 ± 77.6 months. Continuous TEE was used in 936 patients with a mean age of 67.1 ± 14.4 years. RESULTS: Preprocedure examination revealed looped leads in 181 (19.3%) patients, dry cardiac perforation in 151 (16.1%), lead-to-lead adhesion in 172 (18.4%), lead adhesion to the myocardium in 317 (33.9%), and vegetations in 119 (12.7%) patients. Intra-procedural TEE demonstrated pulling on the atrial wall, ventricular wall, or tricuspid valve in 380 (40.5%), 235 (25.1%), and 78 (8.3%) patients, respectively. Acute tamponade requiring sternotomy occurred in 11 (1.1%) patients. Migration of vegetation or connective tissue fragments were seen in 69 (7.3%) and 111 (11.8%) patients, respectively. After procedure, TEE was helpful in navigating an implantation, a new lead in 97 (10.3%) patients, and removing the remnants of lead/silicone insulation in 50 (5.3%) patients. CONCLUSION: Real time transesophageal echocardiography for the guidance of transvenous lead extraction informs the operator about the danger of manipulations close to delicate cardiac structures and whether immediate modification to the plan of lead removal is necessary in order to prevent the occurrence of unwanted events.


Assuntos
Desfibriladores Implantáveis , Ecocardiografia Transesofagiana , Idoso , Idoso de 80 Anos ou mais , Remoção de Dispositivo , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Valva Tricúspide
8.
J Clin Med ; 13(8)2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38673622

RESUMO

Background: Currently, there are no reports describing lead break (LB) during transvenous lead extraction (TLE). Methods: This study conducted a retrospective analysis of 3825 consecutive TLEs using mechanical sheaths. Results: Fracture of the lead, defined as LB, with a long lead fragment (LF) occurred in 2.48%, LB with a short LF in 1.20%, LB with the tip of the lead in 1.78%, and LB with loss of a free-floating LF in 0.57% of cases. In total, extractions with LB occurred in 6.04% of the cases studied. In cases in which the lead remnant comprises more than the tip only, there was a 50.31% chance of removing the lead fragment in its entirety and an 18.41% chance of significantly reducing its length (to less than 4 cm). Risk factors for LB are similar to those for major complications and increased procedure complexity, including long lead dwell time [OR = 1.018], a higher LV ejection fraction, multiple previous CIED-related procedures, and the extraction of passive fixation leads. The LECOM and LED scores also exhibit a high predictive value. All forms of LB were associated with increased procedure complexity and major complications (9.96 vs. 1.53%). There was no incidence of procedure-related death among such patients, and LB did not affect the survival statistics after TLE. Conclusions: LB during TLE occurs in 6.04% of procedures, and this predictable difficulty increases procedure complexity and the risk of major complications. Thus, the possibility of LB should be taken into account when planning the lead extraction strategy and its associated training.

9.
J Clin Med ; 13(9)2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38731132

RESUMO

Background: The study aimed to describe the phenomenon of leads migrated (MPLE) into the cardiovascular system (CVS). Methods: Retrospective analysis of 3847 transvenous lead extractions (TLE). Results: Over a 17-year period, 72 (1.87%) MPLEs (median dwell time 137.5 months) were extracted, which included mainly ventricular leads (56.94%). Overall, 68.06% of MPLEs had their cut proximal ends in the venous system. Most of them were pacing (95.83%) and passive fixation (98.61%) leads. Independent risk factors for MPLE included abandoned leads (OR = 8.473; p < 0.001) and leads located on both sides of the chest (2.981; p = 0.045). The higher NYHA class lowered the probability of MPLE (OR = 0.380; p < 0.001). Procedure complexity was higher in the MPLE group (procedure duration, unexpected procedure difficulties, use of additional (advanced) tools and alternative venous approach). There were no more major complications in the MPLE group, but the rate of procedural success was lower due to more frequent retention of non-removable lead fragments. Extraction of MPLEs did not influence long-term survival. Conclusions: 1. Extraction of leads with MPLE is rare among other TLE procedures (1.9%), 2. risk factors include abandoned leads and presence of leads on both sides of the chest but a higher NYHA class lowers the probability of MPLE, 3. complexity of MPLE extraction is higher regarding procedure duration, unexpected procedure difficulties, use of advanced tools and techniques but rates of major complications are comparable, and 4. extraction of MPLEs did not influence long-term survival.

10.
Clin Physiol Funct Imaging ; 43(1): 47-57, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36251514

RESUMO

Patients requiring temporal or permanent catheter or arterio-venous fistula (AVF) for haemodialysis may be in challenging situation, if they are cardiovascular implantable electronic devices (CIED) carriers. MATERIALS AND METHODS: The authors analysed preoperative venogrphies of 3100 patients referred for transvenous lead extraction for a possible chance of safe haemodialysis catheter (HC) implantation or proper AVF function. RESULTS: A chance of safe catheter implantation parallel to existing leads reaches 68.8% ipsilaterally to CIED. Contraindications for implantation have been found in less than 2% of cases contralaterally. Ipsilaterally proper AVF function chance has been found in 50.3% of the cases and almost 98% contralaterally. A bilateral chest electrodes location require the special attention. Abandoned lead, lead burden, bilateral leads, additional lead implantation or abandonment, and implant duration may have a significant influence on HC insertion or proper function of arteriovenous fistula. CONCLUSION: (1) Obstruction of prominent thoracic veins is a frequent finding in CIED carriers and may impede or disable implantation haemodialysis accesses. (2) Implantation of temporary or permanent HC may be questionable ipsilaterally to the CIED in 31.2% and contralaterally in 2.0% of patients. Proper function of AVF is uncertain in 49.7% ipsilaterally and 2.1% contralaterally to CIED. (3) Pacing history and leads dwell time influence chances of success haemodialysis access even on the free-from CIED chest side. (4) Proper venous flow evaluation seems to be valuable in CIED carriers before an attempt of haemodialysis access formation, even contralaterally.

11.
Cardiovasc Diagn Ther ; 13(6): 1068-1079, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-38162103

RESUMO

Background: Lead-dependent venous occlusion may impede the insertion of a central venous access device (CVAD). The aim of this retrospective, cohort study was to assess the chance of implantation of CVAD in patients with cardiac implantable electronic devices (CIEDs). Methods: We reviewed and analyzed 3,075 venograms of patients with CIEDs undergoing transvenous lead extraction (TLE) between June 2008 and July 2021. Relationship between venous patency and the chance of CVAD placement was estimated. Results: In 2,318 (75.38%) patients, venography showed no potential obstacles to venous port implantation on the ipsilateral side. In patients with leads on the left side, significant narrowing more often affected the subclavian vein than the brachiocephalic vein [1,595 (55.29%) vs. 830 (28.63%), respectively] or the superior vena cava (SVC) [21 (0.73%) cases]. Furthermore, the subclavian and brachiocephalic veins on the opposite side were also narrowed [35 (2.35%) and 27 (1.24%), respectively]. The chances of port insertion were assessed as easy on CIED side or opposite side in 2,318 (75.38%) and 2,291 (97.91%) patients, respectively), as difficult insertion/questionable performance in 246 (8.00%) and 22 (0.94% patients) and doubtful or impossible insertion/questionable performance in 511 (16.62%)/27 (1.15%) patients with CIED. Conclusions: (I) Varying degrees of lead-dependent venous obstruction (LDVO) is a frequent finding in patients with CIEDs; (II) the major thoracic veins on the opposite side of the chest may also be significantly narrowed; (III) venography should be considered before attempted CVAD insertion in patients with long lead dwell times or in patients after CIED removal, including planned contralateral port placement.

12.
Sci Rep ; 12(1): 9601, 2022 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-35689031

RESUMO

Adults with cardiac implantable electronic devices (CIEDs) implanted at an early age constitute a specific group of patients undergoing transvenous lead extraction (TLE). The aim of this study is to assess safety and effectiveness of TLE in young adults. A comparative analysis of two groups of patients undergoing transvenous lead extraction was performed: 126 adults who were 19-29 years old at their first CIED implantation (early adulthood) and 2659 adults who were > 40 years of age at first CIED implantation and < 80 years of age at the time of TLE (middle-age/older adulthood). CIED-dependent risk factors were more common in young adults, especially longer implant duration (169.7 vs. 94.0 months). Moreover younger age of patients at first implantation, regardless of the dwell lead time, is a factor contributing to the greater development of connective tissue proliferation on the leads (OR 2.587; p < 0.001) and adhesions of the leads with the heart structures (OR 3.322; p < 0.001), which translates into worse TLE results in this group of patients. The complexity of procedures and major complications were more common in younger group (7.1 vs. 2.0%; p < 0.001), including hemopericardium (4.8 vs 1.3; p = 0.006) and TLE-induced tricuspid valve damage (3.2 vs.0.3%; p < 0.001). Among middle-aged/older adults, there were 7 periprocedural deaths: 6 related to the TLE procedure and one associated with indications for lead removal. No fatal complications of TLE were reported in young adults despite the above-mentioned differences (periprocedural mortality rate was comparable in study groups 0.3% vs 0.0%; p = 0.739). Predictors of TLE-associated major complications and procedure complexity were more likely in young adults compared with patients aged > 40 to < 80 years. In younger aged patients prolonged extraction duration and higher procedure complexity were combined with a greater need for second line tools. Both major and minor complications were more frequent in young adults, with hemopericardium and tricuspid valve damage being predominant.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Derrame Pericárdico , Adulto , Idoso , Idoso de 80 Anos ou mais , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Humanos , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Derrame Pericárdico/etiologia , Estudos Retrospectivos , Resultado do Tratamento , Valva Tricúspide , Adulto Jovem
13.
Artigo em Inglês | MEDLINE | ID: mdl-36497674

RESUMO

BACKGROUND: Data regarding repeat transvenous lead extraction (TLE) are scarce. The aim of study was to explore the frequency of repeat TLE, its safety, predisposing factors, as well as effectiveness of repeat procedures. METHODS: Retrospective analysis of a large single-center database of 3654 TLEs. RESULTS: Repeat TLE was a rare occurrence (193, i.e., 5,28% among 3654 TLEs). Subsequent re-extractions occurred in 12.21% of the patients. Lead failure was the most common cause of re-extraction (51.16%). Cox regression analysis showed that patients who were older at first implantation [HR = 0.987; p = 0.003], had infection-related TLE [HR = 0.392; p < 0.001] and complete procedural success [HR = 0.544; p = 0.034] were less likely to undergo repeat TLE. Functional leads left in place for continuous use [HR = 1.405; p = 0.012] or superfluous leads left in place (abandoned) [HR = 2.370; p = 0.011] were associated with an increased risk of undergoing a repeat procedure. Overall mortality in patients with repeat TLE and subsequent re-extraction in the entire FU period was similar to that in patients without a history of re-extraction [HR = 0.949; p = 0.480]. CONCLUSIONS: Repeat TLE was a rare occurrence (5.28%) among TLEs. Left of both active and nonactive leads during TLE increased the risk of re-extraction. Re-extraction has no effect on the long-term mortality.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Remoção de Dispositivo/efeitos adversos , Falha de Equipamento , Estudos Retrospectivos , Prognóstico , Chumbo , Resultado do Tratamento
14.
Artigo em Inglês | MEDLINE | ID: mdl-36231841

RESUMO

"Ghosts" are fibrinous remnants that become visible during transvenous lead extraction (TLE). METHODS: Data from transoesophageal echocardiography-guided TLE procedures performed in 1103 patients were analysed to identify predisposing risk factors for the development of so-called disappearing ghosts-flying ghosts (FG), or attached to the cardiovascular wall-stable ghosts (SG), and to find out whether the presence of ghosts affected patient prognosis after TLE. RESULTS: Ghosts were detected in 44.67% of patients (FG 15.5%, SG 29.2%). The occurrence of ghosts was associated with patient age at first system implantation [FG (OR = 0.984; p = 0.019), SG (OR = 0.989; p = 0.030)], scar tissue around the lead (s) [FG (OR = 7.106; p < 0.001, OR = 1.372; p = 0.011), SG (OR = 1.940; p < 0.001)], adherence of the lead to the cardiovascular wall [FG (OR = 0.517; p = 0.034)] and the number of leads [SG (OR = 1.450; p < 0.002). The presence of ghosts had no impact on long-term survival after TLE in the whole study group [FG HR = 0.927, 95% CI (0.742-1.159); p = 0.505; SG HR = 0.845, 95% CI (0.638-1.132); p = 0.265]. CONCLUSIONS: The degree of growth and maturation of scar tissue surrounding the lead was the strongest factor leading to the development of both types of ghosts. The presence of either form of ghost did not affect long-term survival even after TLE indicated for infection.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Cicatriz/etiologia , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/efeitos adversos , Ecocardiografia Transesofagiana , Humanos , Chumbo , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
15.
Kardiochir Torakochirurgia Pol ; 19(3): 122-129, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36268484

RESUMO

Introduction: The guidelines stress the importance of cardiac surgery in the management of life-threatening complications arising from lead removal. Aim: To delineate the roles of the cardiac surgeon during transvenous lead extraction (TLE). Material and methods: 3207 patients (38.7% F), average age 65.7 years, underwent the extraction of PM/ICD leads using standard non-powered mechanical systems within the last 14 years. Results: Procedural success 96.1%, clinical success 97.8%, procedure-related death 0.18%, major complications 1.9% (cardiac tamponade 1.2%, hemothorax 0.2%, tricuspid valve damage 0.3%, stroke and pulmonary embolism < 1%). The roles for cardiac surgery in TLE have been categorized into five areas: 1. Emergency cardiac surgery (1.18% of all patients), 2. Late surgical intervention (TLE-related tricuspid valve dysfunction) (0.44%), 3. Cardiac surgery complementing partially successful TLE (0.68%: removal of lead fragments), 4. Epicardial pacemaker implantation through sternotomy for the above-mentioned reasons (0.65%), 5. Delayed surgical intervention after TLE to place epicardial LV leads (0.53%). Additionally, surgical experience can help in prevention and treatment of wound infection after TLE. Conclusions: Emergency cardiac surgery (mainly due to severe bleeding) is still the most frequent reason for intervention (33.63% (38/113) of all surgical procedures). The other areas of surgical interventions in lead management are: cardiac surgery complementing partially successful TLE, repair or replacement of the malfunctioning tricuspid valve secondary to lead extraction and implantation of permanent epicardial pacing leads after sternotomy or epicardial left ventricle lead to optimize cardiac resynchronization. Experience of a single high-volume lead extraction center confirms the need for close collaboration between the cardiologist and the cardiac surgeon, whose role goes far beyond mere surgical standby.

16.
Vasc Health Risk Manag ; 18: 629-642, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36003848

RESUMO

Background: Lead-related venous stenosis/obstruction (LRVSO) may be a major challenge in patients with cardiac implantable electronic devices (CIED) when device upgrade, insertion of central lines, or creation of an arteriovenous fistula for hemodialysis is indicated. The aim of this study was to evaluate the extent and severity of LRVSO. Methods: We performed a retrospective analysis of 3002 venograms from patients awaiting transvenous lead extraction (TLE) to assess the occurrence, severity, and extent of LRVSO. Results: Mild LRVSO occurred in 19.9%, moderate in 20.7%, severe in 19.9% and total venous occlusion in 22.5% of the patients. Moderate/severe stenosis or total occlusion of the subclavian and brachiocephalic veins was found in 38.2% and 22.5% of the patients, respectively. LRSVO was not detected in 16.9% of the patients. Moderate and severe superior vena cava (SVC) obstruction and total SVC occlusion were rare (0.4%, 0.3%, and 0.3%, respectively). Lead insertion on the left side of the chest contributed to an increased risk of LRVSO compared to right-sided implantation. Major thoracic veins on the opposite side may be narrowed in varying degrees. Conclusion: A total of 60% of the patients with pacemaker or high-voltage leads have an advanced form of LRVSO. Any attempt to insert new pacing leads, central lines, venous ports, or catheters for hemodialysis, or to create dialysis fistula on the same side as the existing lead should be preceded by venography. Furthermore, venography may provide useful information, if it is planned to implant the lead or the catheter on the opposite side of the chest.


Assuntos
Doenças Vasculares , Veia Cava Superior , Veias Braquiocefálicas/diagnóstico por imagem , Constrição Patológica/etiologia , Humanos , Estudos Retrospectivos , Doenças Vasculares/diagnóstico por imagem , Doenças Vasculares/epidemiologia , Doenças Vasculares/etiologia , Veia Cava Superior/diagnóstico por imagem
17.
Artigo em Inglês | MEDLINE | ID: mdl-35627340

RESUMO

Background: Transvenous lead extraction (TLE) in patients with implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy (CRT) devices is considered as more risky. The aim of this study was to assess the safety and effectiveness of TLE in patients with infected CRT systems. Methods: Data of 3468 patients undergoing TLE in a single high-volume center in years 2006−2021 were analyzed. The clinical and procedural parameters as well as the efficacy and safety of TLE were compared between patients with infected CRT and pacemakers (PM) and ICD systems. Results: Infectious indications for TLE occurred in 1138 patients, including 150 infected CRT (112 CRT-D and 38 CRT-P). The general health condition of CRT patients was worse with higher Charlson's comorbidity index. The number of extracted leads was higher in the CRT group, but implant duration was significantly longer in the PM than in the ICD and CRT groups (98.93 vs. 55.26 vs. 55.43 months p < 0.01). The procedure was longer in duration, more difficult, and more complex in patients with pacemakers than in those in the CRT group. The occurrence of major complications and clinical and procedural success as well as procedure-related death did not show any relationship to the type of CIED device. Mortality at more than one-year follow-up after TLE was significantly higher among patients with CRT devices (22.7% vs. 8.7%) than among those in the PM group. Conclusion: Despite the greater burden of lead and comorbidities, the complexity and efficiency of removing infected CRT systems is no more dangerous than removing other infected systems. The duration of the implant seems to play a dominant role.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Comorbidade , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/métodos , Humanos , Chumbo
18.
BMJ Open ; 12(12): e062952, 2022 12 29.
Artigo em Inglês | MEDLINE | ID: mdl-36581437

RESUMO

OBJECTIVES: To estimate the impact of the organisational model of transvenous lead extraction (TLE) on effectiveness and safety of procedures. DESIGN: Post hoc analysis of patient data entered prospectively into a computer database. SETTING: Data of all patients undergoing TLE in three centres in Poland between 2006 and 2021 were analysed. PARTICIPANTS: 3462 patients including: 985 patients undergoing TLE in a hybrid room (HR), with cardiac surgeon (CS) as co-operator, under general anaesthesia (GA), with arterial line (AL) and with transoesophageal echocardiography (TEE) monitoring (group 1), 68 patients-TLE in HR with CS, under GA, without TEE (group 2), 406 patients-TLE in operating theatre (OT) using 'arm-C' X-ray machine with CS under GA and with TEE (group 3), 154 patients-TLE in OT with CS under GA, without TEE (group 4), 113 patients-TLE in OT with anaesthesia team, using the 'arm-C' X-ray machine, without CS (group 5), 122 patients-TLE in electrophysiology lab (EPL), with CS under intravenous analgesia without TEE and AL (group 6), 1614 patients-TLE in EPL, without CS, under intravenous analgesia without TEE and AL (group 7). KEY OUTCOME MEASURE: Effectiveness and safety of TLE depending on organisational model. RESULTS: The rate of major complications (MC) was higher in OT/HR than in EPL (2.66% vs 1.38%), but all MCs were treated successfully and there was no MC-related death. The use of TEE during TLE increased probability of complete procedural succemss achieving about 1.5 times (OR=1.482; p<0.034) and were connected with reduction of minor complications occurrence (OR=0.751; p=0.046). CONCLUSIONS: The most important condition to avoid death due to MC is close co-operation with cardiac surgery team, which permits for urgent rescue cardiac surgery. Continuous TEE monitoring plays predominant role in immediate decision on rescue sternotomy and improves the effectiveness of procedure.


Assuntos
Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Modelos Organizacionais , Resultado do Tratamento , Polônia , Remoção de Dispositivo/métodos , Estudos Retrospectivos
19.
Clin Physiol Funct Imaging ; 41(1): 25-41, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32949059

RESUMO

BACKGROUND: The constant interaction between intracardiac leads and the heart and veins results in excessive accumulation of fibrous connective tissue around the leads. The extent of this pathological phenomenon, which is visible on transesophageal echocardiography (TEE), and predisposing factors are not well defined. METHODS: We examined 936 transesophageal echocardiograms prior to transvenous lead extraction (TLE) performed at a high-volume centre between 2015 and 2019. RESULTS: The most important echocardiographic findings were fibrous binding sites between leads and cardiovascular structures, lead-to-lead adhesions, excessive lead loops, lead-dependent tricuspid dysfunction (LDTD), asymptomatic masses on endocardial leads (AMEL) and vegetations. Fibrotic reaction within the walls of the heart and veins correlated with the presence of lead loops (OR = 1.771; p < .01) and lead dwell time (OR = 1.111; p < .001). Women were more likely to have excessive lead loops (OR = 1.639; p < .01), and the occurrence of loops increase with the number of implanted leads (OR = 2.557; p < .001). Heart failure (OR = 4.016; p < .001), lead looping (OR = 2.603; p < .01) and longer cumulative lead dwell time (OR = 1.017; p < .05) increased the likelihood of LDTD. A variety of AMEL were identified in this study, most commonly in patients with older leads (OR = 1.043; p < .001). CONCLUSIONS: Lead dwell time is the main factor predisposing to the occurrence of most lead-associated phenomena visualized by TEE in patients with cardiac implantable electronic devices (CIED). Excessive looping of the lead is an important cause of fibrous binding sites and LDTD. AMEL are frequently detected in CIED patients, and their various forms concurrent with vegetations could represent an evolutionary stage of lead-associated masses.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Ecocardiografia Transesofagiana/métodos , Marca-Passo Artificial/efeitos adversos , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Idoso , Eletrodos Implantados/efeitos adversos , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
20.
Clin Cardiol ; 44(9): 1233-1242, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34302377

RESUMO

BACKGROUND: Transesophageal echocardiography (TEE) is a useful tool in preoperative evaluation of patients undergoing transvenous lead extraction (TLE). HYPOTHESIS: Echocardiographic phenomena may determine the difficulty and safety of the procedure. METHODS: Data from 936 transesophageal examinations (TEE) performed at a high volume center in patients awaiting TLE from 2015 to 2019 were assessed. RESULTS: TEE revealed a total of 1156 phenomena associated with the implanted leads in 697 (64.85%) patients, including: asymptomatic masses on endocardial leads (AMEL) (58.65%), vegetations (12,73%), fibrous tissue binding the lead to the vein or heart wall (33.76%), lead-to-lead binding sites (18.38%), excess lead loops (19.34%), intramural penetration of the lead tip (16.13%) and lead-dependent tricuspid dysfunction (LDTD) (6.41%). Risk factors for technical difficulties during TLE in multivariate analysis were: fibrous tissue binding the lead to atrial wall (OR = 1.738; p < 0.05), to right ventricular wall (OR = 2.167; p < 0.001), lead-to-lead binding sites (OR = 1.628; p < 0.01) and excess lead loops (OR = 1.488; p < 0.05). Lead-to-lead binding sites increased probability of major complications (OR = 3.034; p < 0.05). Presence of fibrous tissue binding the lead to the superior vena cava (OR = 0.296; p < 0.05), right atrial wall (OR = 323; p < 0.05) and right ventricular wall (OR = 0.297; p < 0.05) reduced the probability of complete procedural success, whereas fibrous tissue binding the lead to the tricuspid apparatus decreased the probability of clinical success (OR = 0.307; p < 0.05). CONCLUSIONS: Careful preoperative TEE evaluation of the consequences of extended lead implant duration (enhanced fibrotic response) increases the probability of predicting the level of difficulty of TLE procedures, their efficacy and risk of major complications.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Remoção de Dispositivo , Ecocardiografia Transesofagiana , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Veia Cava Superior
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA