Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Bioconjug Chem ; 27(1): 217-25, 2016 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-26689321

RESUMO

The diversity of nucleic acid sequences enables genomics studies in a highly multiplexed format. Since multiplex protein detection is still a challenge, it would be useful to use genomics tools for this purpose. This can be accomplished by conjugating specific oligonucleotides to antibodies. Upon binding of the oligonucleotide-conjugated antibodies to their targets, the protein levels can be converted to oligonucleotide levels. In this report we describe a simple method for preparing oligonucleotide-conjugated antibodies and discuss this method's application in oligonucleotide extension reaction (OER) for multiplex protein detection. Conjugation is based on strain-promoted alkyne-azide cycloaddition (the Cu-free click reaction), in which the antibody is activated with a dibenzocyclooctyne (DBCO) moiety and subsequently linked covalently with an azide-modified oligonucleotide. In the functional test, the reaction conditions and purification processes were optimized to achieve maximum yield and best performance. The OER assay employs a pair of antibody binders (two antibodies, each conjugated with its own oligonucleotide) developed for each protein target. The two oligonucleotides contain unique six-base complementary regions at their 3' prime ends to allow annealing and extension by DNA synthesis enzymes to form a DNA template. Following preamplification, the DNA template is detected by qPCR. Distinct oligonucleotide sequences are assigned to different antibody binders to enable multiplex protein detection. When tested using recombinant proteins, some antibody binders, such as those specific to CSTB, MET, EpCAM, and CASP3, had dynamic ranges of 5-6 logs. The antibody binders were also used in a multiplexed format in OER assays, and the binders successfully detected their protein targets in cell lysates, and in single cells in combination with the C1 system. This click reaction-based antibody conjugation procedure is cost-effective, needs minimal hands-on time, and is well-suited for the development of affordable multiplex protein assays, which provides the potential to accelerate proteomics research.


Assuntos
Anticorpos/química , Oligonucleotídeos/química , Proteínas/análise , Análise de Célula Única/métodos , Linhagem Celular , Química Click , Reação de Cicloadição , Humanos , Limite de Detecção , Oligonucleotídeos/metabolismo , Reação em Cadeia da Polimerase/métodos , Proteínas/genética , Proteínas Recombinantes/análise , Proteínas Recombinantes/metabolismo
2.
Aging Cell ; 16(5): 1043-1050, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28699239

RESUMO

Senescent cells play important roles in both physiological and pathological processes, including cancer and aging. In all cases, however, senescent cells comprise only a small fraction of tissues. Senescent phenotypes have been studied largely in relatively homogeneous populations of cultured cells. In vivo, senescent cells are generally identified by a small number of markers, but whether and how these markers vary among individual cells is unknown. We therefore utilized a combination of single-cell isolation and a nanofluidic PCR platform to determine the contributions of individual cells to the overall gene expression profile of senescent human fibroblast populations. Individual senescent cells were surprisingly heterogeneous in their gene expression signatures. This cell-to-cell variability resulted in a loss of correlation among the expression of several senescence-associated genes. Many genes encoding senescence-associated secretory phenotype (SASP) factors, a major contributor to the effects of senescent cells in vivo, showed marked variability with a subset of highly induced genes accounting for the increases observed at the population level. Inflammatory genes in clustered genomic loci showed a greater correlation with senescence compared to nonclustered loci, suggesting that these genes are coregulated by genomic location. Together, these data offer new insights into how genes are regulated in senescent cells and suggest that single markers are inadequate to identify senescent cells in vivo.


Assuntos
Senescência Celular/genética , Fibroblastos/metabolismo , Variação Genética , Análise de Célula Única/métodos , Transcriptoma , Bleomicina/farmacologia , Proteínas de Ciclo Celular/genética , Proteínas de Ciclo Celular/metabolismo , Linhagem Celular , Senescência Celular/efeitos dos fármacos , Citocinas/genética , Citocinas/metabolismo , Feto , Fibroblastos/citologia , Fibroblastos/efeitos dos fármacos , Perfilação da Expressão Gênica , Regulação da Expressão Gênica , Humanos , Pulmão/citologia , Pulmão/efeitos dos fármacos , Pulmão/metabolismo , Microfluídica/instrumentação , Microfluídica/métodos , Nanotecnologia/instrumentação , Nanotecnologia/métodos , Reação em Cadeia da Polimerase/instrumentação , Reação em Cadeia da Polimerase/métodos , Mapeamento de Interação de Proteínas , Transdução de Sinais , Análise de Célula Única/instrumentação , beta-Galactosidase/genética , beta-Galactosidase/metabolismo
4.
Artigo em Inglês | MEDLINE | ID: mdl-27709111

RESUMO

The study of single cells has evolved over the past several years to include expression and genomic analysis of an increasing number of single cells. Several studies have demonstrated wide spread variation and heterogeneity within cell populations of similar phenotype. While the characterization of these populations will likely set the foundation for our understanding of genomic- and expression-based diversity, it will not be able to link the functional differences of a single cell to its underlying genomic structure and activity. Currently, it is difficult to perturb single cells in a controlled environment, monitor and measure the response due to perturbation, and link these response measurements to downstream genomic and transcriptomic analysis. In order to address this challenge, we developed a platform to integrate and miniaturize many of the experimental steps required to study single-cell function. The heart of this platform is an elastomer-based integrated fluidic circuit that uses fluidic logic to select and sequester specific single cells based on a phenotypic trait for downstream experimentation. Experiments with sequestered cells that have been performed include on-chip culture, exposure to various stimulants, and post-exposure image-based response analysis, followed by preparation of the mRNA transcriptome for massively parallel sequencing analysis. The flexible system embodies experimental design and execution that enable routine functional studies of single cells.

5.
PLoS One ; 10(8): e0135007, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26302375

RESUMO

Somatic mosaicism occurs throughout normal development and contributes to numerous disease etiologies, including tumorigenesis and neurological disorders. Intratumor genetic heterogeneity is inherent to many cancers, creating challenges for effective treatments. Unfortunately, analysis of bulk DNA masks subclonal phylogenetic architectures created by the acquisition and distribution of somatic mutations amongst cells. As a result, single-cell genetic analysis is becoming recognized as vital for accurately characterizing cancers. Despite this, methods for single-cell genetics are lacking. Here we present an automated microfluidic workflow enabling efficient cell capture, lysis, and whole genome amplification (WGA). We find that ~90% of the genome is accessible in single cells with improved uniformity relative to current single-cell WGA methods. Allelic dropout (ADO) rates were limited to 13.75% and variant false discovery rates (SNV FDR) were 4.11x10(-6), on average. Application to ER-/PR-/HER2+ breast cancer cells and matched normal controls identified novel mutations that arose in a subpopulation of cells and effectively resolved the segregation of known cancer-related mutations with single-cell resolution. Finally, we demonstrate effective cell classification using mutation profiles with 10X average exome coverage depth per cell. Our data demonstrate an efficient automated microfluidic platform for single-cell WGA that enables the resolution of somatic mutation patterns in single cells.


Assuntos
Neoplasias da Mama/genética , Microfluídica/métodos , Mosaicismo , Análise de Célula Única , Neoplasias da Mama/patologia , Linhagem Celular Tumoral , Variações do Número de Cópias de DNA/genética , Exoma , Feminino , Heterogeneidade Genética , Genoma Humano , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Mutação
6.
Biotechniques ; 34(3): 505-10, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12661156

RESUMO

We report the use of polyelectrolyte multilayers in a stable robust surface chemistry for specific anchoring of DNA to glass. The nonspecific binding of fluorescently tagged nucleotides is suppressed down to the single-molecule level, and DNA polymerase is active on the anchored DNA template. This surface-chemistry platform can be used for single-molecule studies of DNA and DNA polymerase and may be more broadly applicable for other situations in which it is important to have specific biomolecular surface chemistry with extremely low nonspecific binding.


Assuntos
Materiais Revestidos Biocompatíveis/síntese química , DNA Polimerase Dirigida por DNA/química , DNA/química , Eletrólitos/química , Microscopia de Fluorescência/métodos , Biotinilação/métodos , Materiais Revestidos Biocompatíveis/química , Enzimas Imobilizadas , Vidro , Ligação Proteica , Especificidade por Substrato , Propriedades de Superfície
7.
Nat Biotechnol ; 32(10): 1053-8, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25086649

RESUMO

Large-scale surveys of single-cell gene expression have the potential to reveal rare cell populations and lineage relationships but require efficient methods for cell capture and mRNA sequencing. Although cellular barcoding strategies allow parallel sequencing of single cells at ultra-low depths, the limitations of shallow sequencing have not been investigated directly. By capturing 301 single cells from 11 populations using microfluidics and analyzing single-cell transcriptomes across downsampled sequencing depths, we demonstrate that shallow single-cell mRNA sequencing (~50,000 reads per cell) is sufficient for unbiased cell-type classification and biomarker identification. In the developing cortex, we identify diverse cell types, including multiple progenitor and neuronal subtypes, and we identify EGR1 and FOS as previously unreported candidate targets of Notch signaling in human but not mouse radial glia. Our strategy establishes an efficient method for unbiased analysis and comparison of cell populations from heterogeneous tissue by microfluidic single-cell capture and low-coverage sequencing of many cells.


Assuntos
Córtex Cerebral/crescimento & desenvolvimento , Biologia Computacional/métodos , Perfilação da Expressão Gênica/métodos , RNA Mensageiro/análise , Análise de Sequência de RNA/métodos , Transdução de Sinais/genética , Animais , Córtex Cerebral/metabolismo , Desenho de Equipamento , Humanos , Camundongos , Técnicas Analíticas Microfluídicas , RNA Mensageiro/genética , RNA Mensageiro/metabolismo , Transdução de Sinais/fisiologia
8.
PLoS One ; 8(7): e64084, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23894273

RESUMO

Library preparation for next-generation DNA sequencing (NGS) remains a key bottleneck in the sequencing process which can be relieved through improved automation and miniaturization. We describe a microfluidic device for automating laboratory protocols that require one or more column chromatography steps and demonstrate its utility for preparing Next Generation sequencing libraries for the Illumina and Ion Torrent platforms. Sixteen different libraries can be generated simultaneously with significantly reduced reagent cost and hands-on time compared to manual library preparation. Using an appropriate column matrix and buffers, size selection can be performed on-chip following end-repair, dA tailing, and linker ligation, so that the libraries eluted from the chip are ready for sequencing. The core architecture of the device ensures uniform, reproducible column packing without user supervision and accommodates multiple routine protocol steps in any sequence, such as reagent mixing and incubation; column packing, loading, washing, elution, and regeneration; capture of eluted material for use as a substrate in a later step of the protocol; and removal of one column matrix so that two or more column matrices with different functional properties can be used in the same protocol. The microfluidic device is mounted on a plastic carrier so that reagents and products can be aliquoted and recovered using standard pipettors and liquid handling robots. The carrier-mounted device is operated using a benchtop controller that seals and operates the device with programmable temperature control, eliminating any requirement for the user to manually attach tubing or connectors. In addition to NGS library preparation, the device and controller are suitable for automating other time-consuming and error-prone laboratory protocols requiring column chromatography steps, such as chromatin immunoprecipitation.


Assuntos
Cromatografia/métodos , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Técnicas Analíticas Microfluídicas/métodos
9.
Lab Chip ; 12(22): 4809-15, 2012 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-23000861

RESUMO

Advances in microfluidics now allow an unprecedented level of parallelization and integration of biochemical reactions. However, one challenge still faced by the field has been the complexity and cost of the control hardware: one external pressure signal has been required for each independently actuated set of valves on chip. Using a simple post-modification to the multilayer soft lithography fabrication process, we present a new implementation of digital fluidic logic fully analogous to electronic logic with significant performance advances over the previous implementations. We demonstrate a novel normally closed static gain valve capable of modulating pressure signals in a fashion analogous to an electronic transistor. We utilize these valves to build complex fluidic logic circuits capable of arbitrary control of flows by processing binary input signals (pressure (1) and atmosphere (0)). We demonstrate logic gates and devices including NOT, NAND and NOR gates, bi-stable flip-flops, gated flip-flops (latches), oscillators, self-driven peristaltic pumps, delay flip-flops, and a 12-bit shift register built using static gain valves. This fluidic logic shows cascade-ability, feedback, programmability, bi-stability, and autonomous control capability. This implementation of fluidic logic yields significantly smaller devices, higher clock rates, simple designs, easy fabrication, and integration into MSL microfluidics.


Assuntos
Dimetilpolisiloxanos/química , Lógica , Técnicas Analíticas Microfluídicas/instrumentação , Pressão , Impressão/instrumentação , Desenho de Equipamento
10.
Lab Chip ; 11(11): 1962-7, 2011 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-21503367

RESUMO

The compatibility of microfluidic devices with solvents and other chemicals is extremely important for many applications such as organic synthesis in microreactors and drug screening. We report the successful fabrication of microfluidic devices from a novel perfluoropolyether based polymer utilizing the Multilayer Soft Lithography™ (MSL) technique with simple, straightforward processing. The perfluorinated polymer SIFEL X-71 8115 is a highly chemically resistant elastomeric material. We demonstrate fabrication of a microfluidic device using an off-ratio bonding technique to bond multiple SIFEL layers, each patterned lithographically. The mechanical properties of the SIFEL MSL valves (including actuation pressures) are similar to PDMS MSL valves of the same geometry. Chemical compatibility tests highlight SIFEL's remarkable resistance to organic solvents, acids and alkalis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA