Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
J Sep Sci ; 46(24): e2300617, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37880902

RESUMO

We characterized thermally polymerized organo-silica hybrid monolithic capillaries to test their applicability in the gradient elution of peptides. We have used a single-pot approach utilizing 3-(methacryloyloxy)propyltrimethoxysilane (MPTMS), ethylene dimethacrylate (EDMA), and n-octadecyl methacrylate (ODM) as functional monomers. The organo-silica monolith containing MPTMS and EDMA was compared with the stationary phase prepared by adding ODM to the original polymerization mixture. Column prepared using a three-monomer system provided a lower accessible volume of flow-through pores, a higher proportion of mesopores, and higher efficiency. We utilized isocratic and gradient elution data to predict peak widths in gradient elution. Both protocols provided comparable results and can be used for peptide peak width prediction. However, applying gradient elution data for peak width prediction seems simpler. Finally, we tested the effect of gradient time on achievable peak capacity in the gradient elution of peptides with a column prepared with a three-monomer system providing a higher peak capacity. However, the performance of hybrid organo-silica monolithic stationary phases in gradient elution of peptides must be improved compared to other monolithic stationary phases. The limiting factor is column efficiency in highly aqueous mobile phases, which needs to be focused on.


Assuntos
Peptídeos , Dióxido de Silício , Dióxido de Silício/química , Peptídeos/química , Metacrilatos/química , Água
2.
J Sep Sci ; 46(15): e2300174, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37269197

RESUMO

In this article, we review stationary phase-assisted sample prefractionation in proteomic analysis in 2019-2022 period. Applications are grouped according to the mode of retention used in the prefractionation step prior to the final analysis by low-pH reversed-phase liquid chromatography-tandem mass spectrometry. Online or offline instrumental configurations are also commented on, with a highlight on novel online platforms. From the articles reviewed in this period, the order of popularity of chromatographic modes for sample fractionation is affinity chromatography > size exclusion chromatography > hydrophilic interaction chromatography > high-pH reversed-phase liquid chromatography > ion exchange chromatography.


Assuntos
Cromatografia de Fase Reversa , Proteômica , Proteômica/métodos , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia por Troca Iônica/métodos , Cromatografia de Fase Reversa/métodos , Espectrometria de Massas em Tandem/métodos , Interações Hidrofóbicas e Hidrofílicas
3.
J Appl Biomed ; 21(1): 1-6, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-37016774

RESUMO

BACKGROUND: Femoral posterior hip dislocation with associated femoral head fractures (Pipkin fractures) are rare high-energy injuries. Published treatment modalities involve conservative treatment, head fragment resection, open reduction and internal fixation, and total hip replacement. The experience with mini-invasive screw osteosynthesis of these fractures is the main focus of our study. METHODS: Seven Pipkin fractures (five Pipkin II and two Pipkin I) in six patients were treated by closed reduction of hip dislocation, followed by minimal invasive lag screw osteosynthesis. Cancellous screw(s) were inserted from the incision on the lateral hip through the femoral neck to the reduced fracture fragment. In all patients, postoperative CT was performed to check the quality of surgery. Active physiotherapy with immediate toe-touch weight bearing was the routine postoperative protocol. In all patients, radiological and clinical results were evaluated with the Thompson Epstein, Merle d'Aubigne and Postel score, and Harris hip score. RESULTS: All fractures united, and all femoral heads survived. Infectious complications were not observed, and no secondary surgery was needed. After an average follow-up of 18.4 months, the average Merle d'Aubigne and Postel score was 17.7 points, while the mean Harris hip score reached 98.1 points. The majority of patients achieved an excellent Thompson-Epstein clinical and radiological outcome. All patients returned to their original occupation. CONCLUSIONS: Mini-invasive screw osteosynthesis can be used for the treatment of Pipkin type I-II femoral head fractures. Successful reduction of hip dislocation and head fracture is necessary for using this technique. Long-term follow-up is necessary to confirm this technique.


Assuntos
Fraturas do Fêmur , Luxação do Quadril , Fraturas do Quadril , Humanos , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/cirurgia , Fraturas do Quadril/complicações , Cabeça do Fêmur/diagnóstico por imagem , Cabeça do Fêmur/cirurgia , Cabeça do Fêmur/lesões , Luxação do Quadril/complicações , Luxação do Quadril/cirurgia , Fraturas do Fêmur/complicações , Fraturas do Fêmur/cirurgia , Parafusos Ósseos/efeitos adversos
4.
J Proteome Res ; 21(12): 2846-2892, 2022 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-36355445

RESUMO

The performance of the current bottom-up liquid chromatography hyphenated with mass spectrometry (LC-MS) analyses has undoubtedly been fueled by spectacular progress in mass spectrometry. It is thus not surprising that the MS instrument attracts the most attention during LC-MS method development, whereas optimizing conditions for peptide separation using reversed-phase liquid chromatography (RPLC) remains somewhat in its shadow. Consequently, the wisdom of the fundaments of chromatography is slowly vanishing from some laboratories. However, the full potential of advanced MS instruments cannot be achieved without highly efficient RPLC. This is impossible to attain without understanding fundamental processes in the chromatographic system and the properties of peptides important for their chromatographic behavior. We wrote this tutorial intending to give practitioners an overview of critical aspects of peptide separation using RPLC to facilitate setting the LC parameters so that they can leverage the full capabilities of their MS instruments. After briefly introducing the gradient separation of peptides, we discuss their properties that affect the quality of LC-MS chromatograms the most. Next, we address the in-column and extra-column broadening. The last section is devoted to key parameters of LC-MS methods. We also extracted trends in practice from recent bottom-up proteomics studies and correlated them with the current knowledge on peptide RPLC separation.


Assuntos
Cromatografia de Fase Reversa , Proteômica , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia de Fase Reversa/métodos , Espectrometria de Massas/métodos , Peptídeos/análise , Proteômica/métodos
5.
J Sep Sci ; 45(17): 3214-3231, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35932491

RESUMO

Pavel Jandera was a world-leading analytical chemist who devoted his entire professional life to research in the field of high-performance liquid chromatography. During his scientific career, he worked at the Department of Analytical Chemistry at the University of Pardubice, Czech Republic. His greatest contribution to the field of liquid chromatography was the introduction of a comprehensive theory of liquid chromatography with programmed elution conditions. He was also involved in the research of gradient elution techniques in preparative chromatography, modeling of retention and selectivity in various phase systems, preparation of organic monolithic microcolumns, and, last but not least, in the development of theory and practical applications of two-dimensional liquid chromatography, mainly in the comprehensive form. In this review article, we have tried to capture the highlights of his scientific career and provide the readers with a detailed overview of Pavel Jandera's contribution to the evolution of separation sciences.


Assuntos
Cromatografia Líquida , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida/métodos , Humanos , Masculino
6.
J Sep Sci ; 45(17): 3319-3327, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35855653

RESUMO

Retention prediction of monoamine neurotransmitters has been compared for the generally applied linear solvent-strength model and quadratic polynomial three-parameter model. The design of experiments protocol has been applied to plan linear gradients within the experimental space with altered gradient time, mobile phase flow rate, and column temperature. Relative prediction errors increased at elevated temperature, which is more significant for the linear solvent-strength model when compared to the polynomial model. On the other hand, the predefined design of experiments space controls the retention time errors, as predictions for LC conditions that are outside of the plan are much less accurate and should be avoided. The final part of the work deals with the effect of extracolumn band dispersion on the peak capacity of linear gradients at various gradient times, mobile phase flow rates, and column temperature. The peak capacity determined for corrected experimental data were consistent with the published results dealing with the optimization of peak capacity in gradient elution.


Assuntos
Neurotransmissores , Cromatografia Líquida/métodos , Indicadores e Reagentes , Modelos Lineares , Solventes/química
7.
J Sep Sci ; 43(9-10): 1628-1633, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31981291

RESUMO

Thirty years after their introduction, monolithic stationary phases are an important member of chromatographic phases. When compared to conventional particulate materials, the continuous internal structure of both inorganic silica and organic polymer monoliths allows some hydrodynamic and analytical possibilities that are not provided by conventional particulate stationary phases. Polymer-based monolithic stationary phases offer simple preparation and straightforward surface modification, which makes them very versatile materials that are applicable, for example, as chromatographic stationary phases, sample enrichment units, enzymatic reactors, and external trigger-responding materials. On the other hand, current polymer monoliths cannot compete with efficiency provided by superficially porous and sub 2 µm particles. In this highlight article, I take advantage of the 30th anniversary of their introduction to discuss several concerns related to polymer-based monolithic stationary phases. Particularly, I focus on preparation repeatability, porous properties, swelling of the polymers in organic solvents, column efficiency for small molecules, and heterogeneity of dominant flow-through pores. In the end, I offer three possible approaches on how to overcome drawbacks related to stationary phases heterogeneity to further increase the applicability of polymer-based monolithic stationary phases.

8.
J Sep Sci ; 42(5): 952-961, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30576067

RESUMO

In this work, we aimed to prepare a monolithic capillary column that allowed an isocratic separation of ten dopamine precursors and metabolites in a single run. Segments of five zwitterion sulfobetaine polymer monoliths have been modified by zwitterion phoshorylcholine by using an ultraviolet-initiated two-step photografting. Columns with 0, 33, 50, 66, and 100% of modified length were prepared. Effect of length of the modified segment and mobile phase composition has been tested. All columns provided dual-retention mechanism with reversed-phase retention in highly aqueous mobile phase and hydrophilic interaction mechanism in highly organic mobile phase. The retention mechanism was controlled by the composition of the mobile phase and has been described by a three-parameter model. We have used regression parameters to characterize the retention of analyzed compounds and to study individual pathways of dopamine metabolism. Comprehensive optimization of mobile phase composition allowed to find an optimal composition of the mobile phase and stationary phase surface chemistry arrangement to achieve desired separation. Optimized columns provided an isocratic separation of all tested compounds in less than nine min.

9.
J Sep Sci ; 40(8): 1703-1709, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28225173

RESUMO

The duration of the hypercrosslinking reaction has been used to control the extent of small pores formation in polymer-based monolithic stationary phases. Segments of five columns hypercrosslinked for 30-360 min were coupled via zero-volume unions to prepare columns with segmented porosity gradients. The steepness of the porosity gradient affected column efficiency, mass transfer resistance, and separation of both small-molecule alkylbenzenes and high-molar-mass polystyrene standards. In addition, the segmented column with the steepest porosity gradient was prepared as a single column with a continuous porosity gradient. The steepness of porosity gradient in this type column was tuned. Compared to a completely hypercrosslinked column, the column with the shallower gradient produced comparable size-exclusion separation of polystyrene standards but allowed higher column permeability. The completely hypercrosslinked column and the column with porosity gradient were successfully coupled in online two-dimensional liquid chromatography of polymers.

10.
J Sep Sci ; 45(17): 3213, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36068178
11.
J Sep Sci ; 40(7): 1434-1448, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28133899

RESUMO

The amount of water adsorbed on polar columns plays important role in hydrophilic interaction liquid chromatography. It may strongly differ for the individual types of polar columns used in this separation mode. We measured adsorption isotherms of water on an amide and three diol-bonded stationary phases that differ in the chemistry of the bonded ligands and properties of the silica gel support. We studied the effects of the adsorbed water on the retention of aromatic carboxylic acids, flavonoids, benzoic acid derivatives, nucleic bases, and nucleosides in aqueous-acetonitrile mobile phases over the full composition range. The graphs of the retention factors versus the volume fraction of water in mobile phase show "U-profile" characteristic of a dual hydrophilic interaction-reversed phase retention mechanism. The minimum on the graph that marks the changing retention mechanism depends on the amount of adsorbed water. The linear solvation energy relationship model suggests that the retention in the hydrophilic interaction liquid chromatography mode is controlled mainly by proton-donor interactions in the stationary phase, depending on the column type. Finally, the accuracy of hydrophilic interaction liquid chromatography gradient prediction improves for columns that show a high water adsorption.

12.
J Sep Sci ; 39(1): 51-68, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26420171

RESUMO

Since their introduction, the main application area of porous polymer monoliths has been in the fast gradient separation of synthetic and natural polymers. On the other hand, it has proven to be difficult to prepare polymer monoliths providing column efficiency comparable with particulate and monolithic silica-based stationary phases. During this decade, several experimental approaches were performed that aimed to improve this property of polymer monoliths. These protocols include variation in a polymerization time and preparation of monolithic stationary phases at limited conversion of the polymerization reaction, application of novel, highly ordered, nanomaterials, and/or hypercross-linking surface modification controlling the cross-link density of prepared monoliths. By using some of these approaches, monolithic stationary phases with column efficiency reaching 200,000 plates/m for low-molecular-weight compounds have been prepared. This review deals with preparation of polymer monoliths for the separation of small molecules and summarizes recent development in this field. At first, it focuses on monolithic columns morphology and repeatability of their preparation. Then, recent results in individual experimental protocols are discussed. Finally, possible future steps leading to the preparation of more efficient monolithic stationary phases are outlined.

13.
J Sep Sci ; 39(21): 4107-4115, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27592705

RESUMO

Porous polymer monoliths have been used to develop an online solid-phase extraction with liquid chromatography method for determination of dopamine in urine as well as for a continuous monitoring of dopamine in flowing system. A polymerization mixture containing 4-vinylphenylboronic acid monomer has been used to prepare a trapping column based on specific ring formation reaction with dopamine cis-diol functionality. Additionally, a monolithic stationary phase with zwitterion functionality has been used to prepare capillary column for the separation of dopamine. Experimental conditions including molarity, pH, and flow rate of the loading buffer together with a valve switching time have been optimized to provide the highest recovery for dopamine. Experimental setup has been used to determine dopamine in a urine. By using both calibration curve and standard addition method, the dopamine level was determined to be 1.19 and 1.28 mg/L, respectively. Further, we have used experimental design to optimize coupling of two extraction monolithic loops to separation capillary column with monolithic phase for a comprehensive monitoring of dopamine. After multivariate analysis, sample loading flow-rate and a flow-rate of flushing buffer were selected as the most significant variables. Optimized experimental setup was applied to continuously monitor dopamine degradation.


Assuntos
Cromatografia Líquida de Alta Pressão , Dopamina/urina , Extração em Fase Sólida , Humanos , Polimerização , Polímeros
14.
J Sep Sci ; 44(17): 3172-3173, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34486799
15.
J Sep Sci ; 37(21): 3082-9, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25113521

RESUMO

Three dihalogenic solvents differing in the length of alkyl chain (1,2-dichloroethane, 1,4-dichlorobutane, and 1,6-dichlorohexane) with three Friedel-Crafts alkylation catalysts varying in reactivity (AlCl3 , FeCl3 , and SnCl4 ) have been used to prepare hypercrosslinked poly(styrene-co-vinylbenzyl chloride-co-divinylbenzene) columns. Hydrodynamic characteristics as well as column efficiency and mass transfer resistance were tuned by the combination of swelling solvent and alkylation reaction catalyst in the modification mixture. The column swelled in 1,6-dichlorohexane and hypercrosslinked in the presence of AlCl3 provided the highest column efficiency and enabled fast isocratic separations of small molecules in a RP mode. To uncover factors controlling the efficiency of hypercrosslinked monolithic columns, we have studied pore volume distribution of prepared columns. We found that column efficiency increases with the higher pore volume of pores smaller than 2 nm.

16.
Anal Bioanal Chem ; 405(7): 2123-31, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22995998

RESUMO

Owing to their favorable porous structure with pore size distribution shifted towards large flow-through pores, organic polymer monoliths have been mainly employed for the separation of macromolecules in gradient elution liquid chromatography. The absence of significant amounts of small pores with a stagnant mobile phase and the resulting low surface area were considered as the main reason for their poor behavior in the isocratic separation of small molecules. Several recent efforts have improved the separation power of organic polymer monoliths for small molecules offering column efficiency up to tens of thousands of plates per meter. These attempts include optimization of the composition of polymerization mixture, including the variation of functional monomer, the cross-linking monomer, and the porogen solvents mixture, adjustment of polymerization temperature, and time. Additionally, post-polymerization modifications including hypercross-linking and the use of carbon nanostructures showed significant improvement in the column properties. This review describes recent developments in the preparation of organic polymer monoliths suitable for the separation of small molecules in the isocratic mode as well as the main factors affecting the column efficiency.

17.
J Sep Sci ; 36(17): 2806-12, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23868530

RESUMO

A two-step surface modification of poly(styrene-co-vinylbenzyl chloride-co-divinylbenzene) monolithic stationary phases, including hypercrosslinking and thermally initiated surface grafting of [2-(methacryloyloxy)ethyl]dimethyl(3-sulfopropyl)ammonium hydroxide, has been used to prepare capillary columns for the isocratic separation of small polar compounds in hydrophilic interaction chromatography (HILIC). The prepared monolithic columns provided a dual retention mechanism, combining RP and hydrophilic interaction chromatography, controlled by the composition of the mobile phase. By the optimization of the surface grafting reaction using response surface methodology, we have found that the grafting time is the main synergistic effect controlling the retention of polar compounds in HILIC. The prepared monolithic columns achieved long column lifetimes and did not lose their separation power following >10,000 injections. Finally, hypercrosslinked columns have been used in the 1- and 2D LC of phenolic compounds.

18.
J Chromatogr A ; 1691: 463811, 2023 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-36731333

RESUMO

The separation in liquid chromatography is defined either by the space domain where it proceeds until the least retained analyte reaches the outlet of the column or by the time when individual analytes elute out of the column. These two approaches lead to the four possible combinations of two-dimensional liquid chromatography with online space x time coupling being the least experimentally feasible. Here, we show the development of a novel two-dimensional liquid chromatography method combining separation defined by space and the conventional elution-based separation. First-dimension column consisted of four capillary segments coupled serially via two-position six-port valves allowing an online and comprehensive transfer of analytes from the first to the second dimension. After initial experiments using homemade monolithic capillary columns, we tested commercially available columns in both dimensions. We ended with the combination of packed capillary columns in the first dimension and monolithic capillary column in the second dimension. We used a reversed-phase retention mechanism in the first spatial dimension, while HILIC was in the second, time-based dimension. We also developed a theoretical model to describe the proposed two-dimensional separation that was further confirmed by utilizing both an isocratic and gradient elution in the second dimension. Finally, we applied our experimental setup to separate neurotransmitters contained in human urine.


Assuntos
Cromatografia de Fase Reversa , Humanos , Estudo de Prova de Conceito , Cromatografia Líquida/métodos , Cromatografia de Fase Reversa/métodos
19.
Materials (Basel) ; 16(14)2023 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-37512230

RESUMO

The paper deals with research focused on the use of fillers in the field of polymeric materials produced by additive technology SLA (stereolithography). The aim of the research is to evaluate 3D printing parameters, the mechanical properties (tensile strength, hardness), and the interaction of individual phases (polymer matrix and filler) in composite materials using SEM analysis. The tested fillers were cotton flakes and ground carbon fibres in different proportions. For the photosensitive resins, the use of cotton flakes as filler was found to have a positive effect on the mechanical properties not only under static but also under cyclic loading, which is a common cause of material failure in practice. The cyclic stress reference value was set at an amplitude of 5-50% of the maximum force required to break the pure resin in a static tensile test. A positive effect of fillers on the cyclic stress life of materials was demonstrated. The service life of pure resin was only 168 ± 29 cycles. The service life of materials with fillers increased to approximately 400 to 540 cycles for carbon fibre-based fillers and nearly 1000 cycles for cotton flake-based fillers, respectively. In this paper, new composite materials suitable for the use of SLA additive manufacturing techniques are presented. Research demonstrated the possibilities of adding cotton-based fillers in low-cost, commercially available resins. Furthermore, the importance of material research under cyclic loading was demonstrated.

20.
Biotechnol Bioeng ; 109(2): 371-80, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21915852

RESUMO

An enzymatic reactor with lipase immobilized on a monolithic polymer support has been prepared and used to catalyze the transesterification of triacylglycerides into the fatty acid methyl esters commonly used for biodiesel. A design of experiments procedure was used to optimize the monolithic reactor with variables including control of the surface polarity of the monolith via variations in the length of the hydrocarbon chain in alkyl methacrylate monomer, time of grafting of 1-vinyl-4,4-dimethylazlactone used to activate the monolith, and time used for the immobilization of porcine lipase. Optimal conditions involved the use of a poly(stearyl methacrylate-co-ethylene dimethacrylate) monolith, grafted first with vinylazlactone, then treated with lipase for 2 h to carry out the immobilization of the enzyme. Best conditions for the transesterification of glyceryl tributyrate included a temperature of 37°C and a 10 min residence time of the substrate in the bioreactor. The reactor did not lose its activity even after pumping through it a solution of substrate equaling 1,000 reactor volumes. This enzymatic reactor was also used for the transesterification of triacylglycerides from soybean oil to fatty acid methyl esters thus demonstrating the ability of the reactor to produce biodiesel.


Assuntos
Biocombustíveis , Reatores Biológicos , Enzimas Imobilizadas/metabolismo , Lipase/metabolismo , Animais , Enzimas Imobilizadas/química , Esterificação , Ácidos Graxos/metabolismo , Cinética , Lipase/química , Análise de Regressão , Óleo de Soja , Suínos , Triglicerídeos/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA