Resultados 1 - 20 de 23
Filtrar
1.
AJR Am J Roentgenol ; 220(3): 358-370, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36043610

RESUMO

BACKGROUND. Targeted axillary lymph node dissection after neoadjuvant systemic therapy (NST) for breast cancer depends on identifying marked metastatic lymph nodes. However, ultrasound visualization of biopsy markers is challenging. OBJECTIVE. The purpose of our study was to identify biopsy markers that show actionable twinkling in cadaveric breast and to assess the association of actionable twinkling with markers' surface roughness. METHODS. Commercial breast biopsy markers were evaluated for twinkling artifact in various experimental conditions relating to scanning medium (solid gel phantom, ultrasound coupling gel, cadaveric breast), transducer (ML6-15, 9L, C1-6), and embedding material (present vs absent). Markers were assigned twinkling scores from 0 (confident in no twinkling) to 4 (confident in exuberant twinkling); a score of 3 or greater represented actionable twinkling (sufficient confidence to rely solely on twinkling for target localization). Markers were hierarchically advanced to evaluation with increasingly complex media if showing at least minimal twinkling for a given medium. A 3D coherence optical profiler measured marker surface roughness. Mixed-effects proportional odds regression models assessed associations between twinkling scores and transducer and embedding material; Wilcoxon rank sum test evaluated associations between actionable twinkling and surface roughness. RESULTS. Thirty-five markers (21 with embedding material) were evaluated. Ten markers without embedding material advanced to evaluation in cadaveric breast. Higher twinkling scores were associated with presence of embedding material (odds ratio [OR] = 5.05 in solid gel phantom, 9.84 in coupling gel) and transducer (using the C1-6 transducer as reference; 9L transducer: OR = 0.36, 0.83, and 0.04 in solid gel phantom, ultrasound coupling gel, and cadaveric breast; ML6-15 transducer: OR = 0.07, 0.18, and 0.00 respectively; post hoc p between 9L and ML6-15: p < .001, p = .02, and p = .04). In cadaveric breast, three markers (Cork, Professional Q, MRI [Flex]) exhibited actionable twinkling for two or more transducers; surface roughness was significantly higher for markers with than without actionable twinkling for C1-6 (median values: 0.97 vs 0.35, p = .02) and 9L (1.75 vs 0.36; p = .002) transducers. CONCLUSION. Certain breast biopsy markers exhibited actionable twinkling in cadaveric breast. Twinkling was observed with greater confidence for the C1-6 and 9L transducers than the ML6-15 transducer. Actionable twinkling was associated with higher marker surface roughness. CLINICAL IMPACT. Use of twinkling for marker detection could impact preoperative or intraoperative localization after NST.


Assuntos
Neoplasias da Mama , Ultrassonografia Doppler em Cores , Humanos , Feminino , Ultrassonografia Doppler em Cores/métodos , Ultrassonografia , Imagens de Fantasmas , Artefatos , Cadáver , Biópsia
2.
J Biomech Eng ; 141(6): 61004-6100412, 2019 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-30874717

RESUMO

Commercially available heart valves have many limitations, such as a lack of remodeling, risk of calcification, and thromboembolic problems. Many state-of-the-art tissue-engineered heart valves (TEHV) rely on recellularization to allow remodeling and transition to mechanical behavior of native tissues. Current in vitro testing is insufficient in characterizing a soon-to-be living valve due to this change in mechanical response; thus, it is imperative to understand the performance of an in situ valve. However, due to the complex in vivo environment, this is difficult to accomplish. Finite element (FE) analysis has become a standard tool for modeling mechanical behavior of heart valves; yet, research to date has mostly focused on commercial valves. The purpose of this study has been to evaluate the mechanical behavior of a TEHV material before and after 6 months of implantation in a rat subdermis model. This model allows the recellularization and remodeling potential of the material to be assessed via a simple and inexpensive means prior to more complex ovine orthotropic studies. Biaxial testing was utilized to evaluate the mechanical properties, and subsequently, constitutive model parameters were fit to the data to allow mechanical performance to be evaluated via FE analysis of a full cardiac cycle. Maximum principal stresses and strains from the leaflets and commissures were then analyzed. The results of this study demonstrate that the explanted tissues had reduced mechanical strength compared to the implants but were similar to the native tissues. For the FE models, this trend was continued with similar mechanical behavior in explant and native tissue groups and less compliant behavior in implant tissues. Histology demonstrated recellularization and remodeling although remodeled collagen had no clear directionality. In conclusion, we observed successful recellularization and remodeling of the tissue giving confidence to our TEHV material; however, the mechanical response indicates the additional remodeling would likely occur in the aortic/pulmonary position.

3.
J Magn Magn Mater ; 427: 100-104, 2017 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-28286359

RESUMO

Emerging nanotechnologies have enabled the use of magnetic forces to guide the movement of magnetically-labeled cells, drugs, and other therapeutic agents. Endothelial cells labeled with superparamagnetic iron oxide nanoparticles (SPION) have previously been captured on the surface of magnetizable 2205 duplex stainless steel stents in a porcine coronary implantation model. Recently, we have coated these stents with electrospun polyurethane nanofibers to fabricate prototype stent-grafts. Facilitated endothelialization may help improve the healing of arteries treated with stent-grafts, reduce the risk of thrombosis and restenosis, and enable small-caliber applications. When placed in a SPION-labeled endothelial cell suspension in the presence of an external magnetic field, magnetized stent-grafts successfully captured cells to the surface regions adjacent to the stent struts. Implantation within the coronary circulation of pigs (n=13) followed immediately by SPION-labeled autologous endothelial cell delivery resulted in widely patent devices with a thin, uniform neointima and no signs of thrombosis or inflammation at 7 days. Furthermore, the magnetized stent-grafts successfully captured and retained SPION-labeled endothelial cells to select regions adjacent to stent struts and between stent struts, whereas the non-magnetized control stent-grafts did not. Early results with these prototype devices are encouraging and further refinements will be necessary in order to achieve more uniform cell capture and complete endothelialization. Once optimized, this approach may lead to more rapid and complete healing of vascular stent-grafts with a concomitant improvement in long-term device performance.

4.
Tissue Eng Part A ; 29(15-16): 413-423, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37130041

RESUMO

Recruitment of endothelial cells to cardiovascular device surfaces could solve issues of thrombosis, neointimal hyperplasia, and restenosis. Since current targeting strategies are often nonspecific, new technologies to allow for site-specific cell localization and capture in vivo are needed. The development of cytocompatible superparamagnetic iron oxide nanoparticles has allowed for the use of magnetism for cell targeting. In this study, a magnetic polyurethane (PU)-2205 stainless steel (2205-SS) nanofibrous composite biomaterial was developed through analysis of composite sheets and application to stent-grafts. The PU nanofibers provide strength and elasticity while the 2205-SS microparticles provide ferromagnetic properties. Sheets were electrospun at mass ratios of 0-4:1 (2205-SS:PU) and stent-grafts with magnetic or nonmagnetic stents were coated at the optimal ratio of 2:1. These composite materials were characterized by microscopy, mechanical testing, a sessile drop test, magnetic field measurement, magnetic cell capture assays, and cytocompatibility after 14 days of culturing with endothelial cells. Results of this study show that an optimal ratio of 2:1 2205-SS:PU results in a hydrophobic material that balanced mechanical and magnetic properties and was cytocompatible up to 14 days. Significant cell capture required a thicker material of 0.5 mm thickness. Stent-grafts fabricated from a magnetic coating and a magnetic stent demonstrated uniform cell capture throughout the device surface. This novel biomaterial exhibits a combination of mechanical and magnetic properties that enables magnetic capture of cells and other therapeutic agents for vascular and other tissue engineering applications.


Assuntos
Materiais Biocompatíveis , Nanofibras , Materiais Biocompatíveis/farmacologia , Materiais Biocompatíveis/química , Engenharia Tecidual , Nanofibras/química , Poliuretanos/farmacologia , Células Endoteliais , Fenômenos Magnéticos , Materiais Revestidos Biocompatíveis/química
5.
Brachytherapy ; 22(6): 761-768, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37652777

RESUMO

PURPOSE: Suboptimal ultrasound conspicuity of the brachytherapy applicator can lead to inaccurate image reconstructions of the applicator resulting in decreased tumor control or increased normal tissue dose. This feasibility study aims to improve ultrasound conspicuity of high-dose rate (HDR) brachytherapy needles by modifying the surface of the needles to produce a color Doppler twinkling signature. MATERIALS AND METHODS: Surface modifications of standard 17-gauge titanium HDR brachytherapy needles included laser-scribing, application of polymethyl methacrylate (PMMA), and coating with a commercially available echogenic coating. Laser-scribing was performed with variable widths (0.1-1 mm) and depths (10-100 µm). The echogenic coating was applied with 3 different thicknesses (27, 40, and 64 µm). Unmodified and modified needles were imaged under B-mode and color Doppler ultrasound in phantom and cadaver, and the signal strength was recorded. RESULTS: Laser-scribed, PMMA-coated, and echogenic-coated brachytherapy needles produced a twinkling signature along the needle shaft on color Doppler ultrasound. Twinkling was observed with laser-scribe depths >20 µm and widths >0.1 mm and from echogenic coatings 40 µm and 64 µm thick. Twinkling was not observed with unmodified needles. The twinkling signature had a spectral composition with a uniform magnitude between the velocities of 2 to 16 cm/s. CONCLUSIONS: Color Doppler ultrasound of surface-modified brachytherapy applicators may improve applicator conspicuity aiding applicator placement and digitization. HDR brachytherapy needles may be modified to produce the twinkling signature via laser-scribing, PMMA rings, or applying an echogenic coating.


Assuntos
Braquiterapia , Masculino , Humanos , Braquiterapia/métodos , Polimetil Metacrilato , Próstata , Ultrassonografia , Agulhas
6.
J Neural Eng ; 20(1)2023 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-36538815

RESUMO

Objective. To modify off-the-shelf components to build a device for collecting electroencephalography (EEG) from macroelectrodes surrounded by large fluid access ports sampled by an integrated microperfusion system in order to establish a method for sampling brain interstitial fluid (ISF) at the site of stimulation or seizure activity with no bias for molecular size.Approach. Twenty-four 560µm diameter holes were ablated through the sheath surrounding one platinum-iridium macroelectrode of a standard Spencer depth electrode using a femtosecond UV laser. A syringe pump was converted to push-pull configuration and connected to the fluidics catheter of a commercially available microdialysis system. The fluidics were inserted into the lumen of the modified Spencer electrode with the microdialysis membrane removed, converting the system to open flow microperfusion. Electrical performance and analyte recovery were measured and parameters were systematically altered to improve performance. An optimized device was tested in the pig brain and unbiased quantitative mass spectrometry was used to characterize the perfusate collected from the peri-electrode brain in response to stimulation.Main results. Optimized parameters resulted in >70% recovery of 70 kDa dextran from a tissue analog. The optimized device was implanted in the cortex of a pig and perfusate was collected during four 60 min epochs. Following a baseline epoch, the macroelectrode surrounded by microperfusion ports was stimulated at 2 Hz (0.7 mA, 200µs pulse width). Following a post-stimulation epoch, the cortex near the electrode was stimulated with benzylpenicillin to induce epileptiform activity. Proteomic analysis of the perfusates revealed a unique inflammatory signature induced by electrical stimulation. This signature was not detected in bulk tissue ISF.Significance. A modified dual-sensing electrode that permits coincident detection of EEG and ISF at the site of epileptiform neural activity may reveal novel pathogenic mechanisms and therapeutic targets that are otherwise undetectable at the bulk tissue level.


Assuntos
Líquido Extracelular , Proteômica , Animais , Suínos , Líquido Extracelular/química , Encéfalo , Eletrodos , Eletroencefalografia
7.
J Vis Exp ; (179)2022 01 06.
Artigo em Inglês | MEDLINE | ID: mdl-35068481

RESUMO

The endothelium is a dynamic integrated structure that plays an important role in many physiological functions such as angiogenesis, hemostasis, inflammation, and homeostasis. The endothelium also plays an important role in pathophysiologies such as atherosclerosis, hypertension, and diabetes. Endothelial cells form the inner lining of blood and lymphatic vessels and display heterogeneity in structure and function. Various groups have evaluated the functionality of endothelial cells derived from human peripheral blood with a focus on endothelial progenitor cells derived from hematopoietic stem cells or mature blood outgrowth endothelial cells (or endothelial colony-forming cells). These cells provide an autologous resource for therapeutics and disease modeling. Xenogeneic cells may provide an alternative source of therapeutics due to their availability and homogeneity achieved by using genetically similar animals raised in similar conditions. Hence, a robust protocol for the isolation and expansion of highly proliferative blood outgrowth endothelial cells from porcine peripheral blood has been presented. These cells can be used for numerous applications such as cardiovascular tissue engineering, cell therapy, disease modeling, drug screening, studying endothelial cell biology, and in vitro co-cultures to investigate inflammatory and coagulation responses in xenotransplantation.


Assuntos
Aterosclerose , Células Progenitoras Endoteliais , Animais , Coagulação Sanguínea , Terapia Baseada em Transplante de Células e Tecidos , Suínos , Engenharia Tecidual/métodos
8.
Eur Radiol Exp ; 6(1): 26, 2022 06 17.
Artigo em Inglês | MEDLINE | ID: mdl-35711010

RESUMO

Since its first description 25 years ago, color Doppler twinkling has been a compelling ultrasound feature in diagnosing urinary stones. While the fundamental cause of twinkling remains elusive, the distinctive twinkling signature is diagnostically valuable in clinical practice. It can be inferred that if an entity twinkles, it empirically has certain physical features. This work investigates a manipulable polymeric material, polymethyl methacrylate (PMMA), which twinkles and has measurable surface roughness and porosity that likely contribute to twinkling. Comparative investigation of these structural properties and of the twinkling signatures of breast biopsy markers made from PMMA and selected commercially available markers showed how twinkling can improve ultrasound detection of devices intentionally designed to twinkle. While this specific application of detecting breast biopsy markers by twinkling may provide a way to approach an unmet need in the care of patients with breast cancer, this work ultimately provides a platform from which the keys to unlocking the fundamental physics of twinkling can be rigorously explored.


Assuntos
Artefatos , Cálculos Renais , Biópsia , Humanos , Cálculos Renais/patologia , Polimetil Metacrilato , Ultrassonografia Doppler em Cores
9.
Ultrasound Med Biol ; 47(11): 3122-3134, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34412903

RESUMO

In breast radiology, ultrasound detection of biopsy markers or clips for localization purposes is often challenging, especially in the axilla. The purpose of this research was to test the hypothesis that the surface roughness of biopsy clips would elicit a twinkling signature on color Doppler, making them more readily identifiable by ultrasound. Ultrasound color Doppler imaging of 12 biopsy markers was performed and consensus scoring of the degree of twinkling (0 [no twinkling] to 4 [exuberant twinkling]) was obtained for each of the markers. The surface roughness characteristics of the markers were measured using 3-D coherence scanning interferometry. The 3 markers scoring at least 3 for twinkling in vitro were cork, Q and Vision. Of these 3 markers, only the cork marker scored a 4 ex vivo and in cadaveric tissue. Surface roughness metrics demonstrated a positive estimated correlation with the twinkling scores (rho = 0.33, 95% CI = [-0.48 to 0.84]). Of the 12 markers tested, the markers that twinkled corresponded to surface roughness measured with non-contact 3-D optical imaging. Qualitatively, lower color scales and color frequencies optimized twinkling, but the most specific qualitative predictor of confidence in twinkling was insensitivity to changes in color scale and color frequency values.


Assuntos
Artefatos , Ultrassonografia Doppler em Cores , Axila , Biópsia , Humanos , Ultrassonografia
10.
Brain Sci ; 11(4)2021 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-33921861

RESUMO

Computational fluid dynamics (CFD) has grown as a tool to help understand the hemodynamic properties related to the rupture of cerebral aneurysms. Few of these studies deal specifically with aneurysm growth and most only use a single time instance within the aneurysm growth history. The present retrospective study investigated four patient-specific aneurysms, once at initial diagnosis and then at follow-up, to analyze hemodynamic and morphological changes. Aneurysm geometries were segmented via the medical image processing software Mimics. The geometries were meshed and a computational fluid dynamics (CFD) analysis was performed using ANSYS. Results showed that major geometry bulk growth occurred in areas of low wall shear stress (WSS). Wall shape remodeling near neck impingement regions occurred in areas with large gradients of WSS and oscillatory shear index. This study found that growth occurred in areas where low WSS was accompanied by high velocity gradients between the aneurysm wall and large swirling flow structures. A new finding was that all cases showed an increase in kinetic energy from the first time point to the second, and this change in kinetic energy seems correlated to the change in aneurysm volume.

11.
J Mech Behav Biomed Mater ; 100: 103399, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31479817

RESUMO

The purpose of the work presented here was to establish an experimental testing configuration that would generate a bending compression fracture in a laboratory setting. To this end, we designed and fabricated a fixture to accommodate a three level spine segment and to be able to perform mechanical testing by applying an off-centric compressive loading to create a flexion-type motion. Forces and moments occurring during testing were measured with a six-channel load cell. The initial testing configuration (Fixture A) included plates connected to the superior potted vertebral body and to the ball-socket joint of the testing system ram. Surprisingly, while all cadaveric specimens underwent a similar off-centric compressive loading, most of the specimens showed extension outcomes as opposed to the intended pure-flexion motion. The extension was due to fixture size and weight; by applying an off-centric load directly on the top plate, unintended large shear forces were generated. To resolve the issue, several modifications were made to the original fixture configuration. These modifications included the removal of the superior plates and the implementation of wedges at the superior surface of the fixture (Fixture B). A synthetic sample was used during this modification phase to minimize the number of cadaveric specimens while optimizing the process. The best outcomes were consistently observed when a 15°-wedge was used to provide flexion-type loading. Cadaveric specimens were then experimentally tested to fracture using the modified testing configuration (Fixture B). A comparison between both fixtures, A and B, revealed that almost all biomechanical parameters, including force, moment, and displacement data, were affected by the testing setup. These results suggest that fixture design and implementation for testing is of extreme importance, and can influence the fracture properties and affect the intended motion.


Assuntos
Consolidação da Fratura , Fraturas da Coluna Vertebral/fisiopatologia , Idoso , Fenômenos Biomecânicos , Placas Ósseas , Cadáver , Força Compressiva , Feminino , Humanos , Masculino , Teste de Materiais , Fenômenos Mecânicos , Pessoa de Meia-Idade , Movimento (Física) , Amplitude de Movimento Articular , Rotação , Resistência ao Cisalhamento , Estresse Mecânico , Resultado do Tratamento
12.
Tissue Eng Part A ; 24(13-14): 1157-1166, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29431053

RESUMO

Incomplete endothelialization of intracoronary stents has been associated with stent thrombosis and recurrent symptoms, whereas prolonged use of dual antiplatelet therapy increases bleeding-related adverse events. Facilitated endothelialization has the potential to improve clinical outcomes in patients who are unable to tolerate dual antiplatelet therapy. The objective of this study was to demonstrate the feasibility of magnetic cell capture to rapidly endothelialize intracoronary stents in a large animal model. A novel stent was developed from a magnetizable duplex stainless steel (2205 SS). Polylactic-co-glycolic acid and magnetite (Fe3O4) were used to synthesize biodegradable superparamagnetic iron oxide nanoparticles, and these were used to label autologous blood outgrowth endothelial cells. Magnetic 2205 SS and nonmagnetic 316L SS control stents were implanted in the coronary arteries of pigs (n = 11), followed by intracoronary delivery of magnetically labeled cells to 2205 SS stents. In this study, we show extensive endothelialization of magnetic 2205 SS stents (median 98.4% cell coverage) within 3 days, whereas the control 316L SS stents exhibited significantly less coverage (median 48.9% cell coverage, p < 0.0001). This demonstrates the ability of intracoronary delivery of magnetic nanoparticle labeled autologous endothelial cells to improve endothelialization of magnetized coronary stents within 3 days of implantation.


Assuntos
Células Endoteliais/citologia , Metais/química , Nanopartículas/química , Stents , Animais , Células Endoteliais/efeitos dos fármacos , Células Endoteliais/ultraestrutura , Feminino , Nanopartículas/ultraestrutura , Fenótipo , Aço Inoxidável/farmacologia , Suínos
13.
J Vis Exp ; (126)2017 08 17.
Artigo em Inglês | MEDLINE | ID: mdl-28872111

RESUMO

Mechanical testing of femora brings valuable insights into understanding the contribution of clinically-measureable variables such as bone mineral density distribution and geometry on the femoral mechanical properties. Currently, there is no standard protocol for mechanical testing of such geometrically complex bones to measure strength, and stiffness. To address this gap we have developed a protocol to test cadaveric femora to fracture and to measure their biomechanical parameters. This protocol describes a set of adaptable fixtures to accommodate the various load magnitudes and directions accounting for possible bone orientations in a fall on the hip configuration, test speed, bone size, and left leg-right leg variations. The femora were prepared for testing by cleaning, cutting, scanning, and potting the distal end and greater trochanter contact surfaces in poly(methyl methacrylate) (PMMA) as presented in a different protocol. The prepared specimens were placed in the testing fixture in a position mimicking a sideways fall on the hip and loaded to fracture. During testing, two load cells measured vertical forces applied to the femoral head and greater trochanter, a six-axis load cell measured forces and moments at the distal femoral shaft, and a displacement sensor measured differential displacement between the femoral head and trochanter contact supports. High speed video cameras were used to synchronously record the sequence of fracture events during testing. The reduction of this data allowed us to characterize the strength, stiffness, and fracture energy for nearly 200 osteoporotic, osteopenic, and normal cadaveric femora for further development of engineering-based diagnostic tools for osteoporosis research.


Assuntos
Acidentes por Quedas/prevenção & controle , Fenômenos Biomecânicos/fisiologia , Fraturas do Fêmur/cirurgia , Idoso , Feminino , Fraturas do Fêmur/patologia , Humanos , Masculino
14.
J Vis Exp ; (127)2017 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-28994795

RESUMO

This protocol describes the method using digital image correlation to estimate cortical strain from high speed video images of the cadaveric femoral surface obtained from mechanical testing. This optical method requires a texture of many contrasting fiduciary marks on a solid white background for accurate tracking of surface deformation as loading is applied to the specimen. Immediately prior to testing, the surface of interest in the camera view is painted with a water-based white primer and allowed to dry for several minutes. Then, a black paint is speckled carefully over the white background with special consideration for the even size and shape of the droplets. Illumination is carefully designed and set such that there is optimal contrast of these marks while minimizing reflections through the use of filters. Images were obtained through high speed video capture at up to 12,000 frames/s. The key images prior to and including the fracture event are extracted and deformations are estimated between successive frames in carefully sized interrogation windows over a specified region of interest. These deformations are then used to compute surface strain temporally during the fracture test. The strain data is very useful for identifying fracture initiation within the femur, and for eventual validation of proximal femur fracture strength models derived from Quantitative Computed Tomography-based Finite Element Analysis (QCT/FEA).


Assuntos
Fraturas do Fêmur/diagnóstico por imagem , Fêmur/diagnóstico por imagem , Fraturas do Fêmur/patologia , Fêmur/patologia , Humanos , Tomografia Computadorizada por Raios X/métodos
15.
J Vis Exp ; (121)2017 03 11.
Artigo em Inglês | MEDLINE | ID: mdl-28362373

RESUMO

Cadaveric fracture testing is routinely used to understand factors that affect proximal femur strength. Because ex vivo biological tissues are prone to lose their mechanical properties over time, specimen preparation for experimental testing must be performed carefully to obtain reliable results that represent in vivo conditions. For that reason, we designed a protocol and a set of fixtures to prepare the femoral specimens such that their mechanical properties experienced minimal changes. The femora were kept in a frozen state except during preparation steps and mechanical testing. The relevant clinical measures of total hip and femoral neck bone mineral density (BMD) were obtained with a clinical dual X-ray absorptiometry (DXA) bone densitometer, and the 3D geometry and distribution of bone mineral were obtained using CT with a calibration phantom for quantitative estimations based on the greyscale values. Any possible bone disease, fracture, or the presence of implants or artifacts affecting the bone structure, was ruled out with X-ray scans. For preparation, all bones were carefully cleaned of excess soft tissue, and were cut and potted at the internal rotation angle of interest. A cutting fixture allowed the distal end of the bone to be cut off leaving the proximal femur at a desired length. To allow positioning of the femoral neck at prescribed angles during later CT scanning and mechanical testing, the proximal femoral shafts were potted in polymethylmethacrylate (PMMA) using a fixture designed specifically for desired orientations. The data collected from our experiments were then used for validation of quantitative computed tomography (QCT)-based finite element analysis (FEA), as described in a different protocol. In this manuscript, we present the protocol for the precise bone preparation for mechanical testing and subsequent QCT/FEA modeling. The current protocol was successfully applied to prepare about 200 cadaveric femora over a 6-year time period.


Assuntos
Absorciometria de Fóton/métodos , Fêmur , Análise de Elementos Finitos , Fraturas Ósseas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Absorciometria de Fóton/instrumentação , Densidade Óssea , Cadáver , Fêmur/diagnóstico por imagem , Colo do Fêmur , Humanos
16.
J Vis Exp ; (116)2016 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-27805589

RESUMO

Stent-grafts are widely used for the treatment of various conditions such as aortic lesions, aneurysms, emboli due to coronary intervention procedures and perforations in vasculature. Such stent-grafts are manufactured by covering a stent with a polymer membrane. An ideal stent-graft should have a biocompatible stent covered by a porous, thromboresistant, and biocompatible polymer membrane which mimics the extracellular matrix thereby promoting injury site healing. The goal of this protocol is to manufacture a small caliber stent-graft by encapsulating a balloon expandable stent within two layers of electrospun polyurethane nanofibers. Electrospinning of polyurethane has been shown to assist in healing by mimicking native extracellular matrix, thereby promoting endothelialization. Electrospinning polyurethane nanofibers on a slowly rotating mandrel enabled us to precisely control the thickness of the nanofibrous membrane, which is essential to achieve a small caliber balloon expandable stent-graft. Mechanical validation by crimping and expansion of the stent-graft has shown that the nanofibrous polyurethane membrane is sufficiently flexible to crimp and expand while staying patent without showing any signs of tearing or delamination. Furthermore, stent-grafts fabricated using the methods described here are capable of being implanted using a coronary intervention procedure using standard size guide catheters.


Assuntos
Desenho de Prótese , Stents , Aorta , Desenho de Equipamento , Humanos , Metais , Nanofibras , Poliuretanos , Transplantes
17.
J Biomech ; 48(1): 153-61, 2015 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-25442008

RESUMO

The aim of the present study was to compare proximal femur strength and stiffness obtained experimentally with estimations from Finite Element Analysis (FEA) models derived from Quantitative Computed Tomography (QCT) scans acquired at two different scanner settings. QCT/FEA models could potentially aid in diagnosis and treatment of osteoporosis but several drawbacks still limit their predictive ability. One potential reason is that the models are still sensitive to scanner settings which could lead to changes in assigned material properties, thus limiting their results accuracy and clinical effectiveness. To find the mechanical properties we fracture tested 44 proximal femora in a sideways fall-on-the-hip configuration. Before testing, we CT scanned all femora twice, first at high resolution scanner settings, and second at low resolution scanner settings and built 88 QCT/FEA models of femoral strength and stiffness. The femoral set neck bone mineral density, as measured by DXA, uniformly covered the range from osteoporotic to normal. This study showed that the femoral strength and stiffness values predicted from high and low resolution scans were significantly different (p<0.0001). Strength estimated from high resolution QCT scans was larger for osteoporotic, but smaller for normal and osteopenic femora when compared to low resolution scans. In addition, stiffness estimated from high resolution scans was consistently larger than stiffness obtained from low resolution scans over the entire femoral dataset. While QCT/FEA techniques hold promise for use in clinical settings we provided evidence that further improvements are required to increase robustness in their predictive power under different scanner settings and modeling assumptions.


Assuntos
Fêmur/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Feminino , Fêmur/fisiologia , Análise de Elementos Finitos , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade
18.
J Vis Exp ; (105): e53099, 2015 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-26554870

RESUMO

Targeted delivery of cells and therapeutic agents would benefit a wide range of biomedical applications by concentrating the therapeutic effect at the target site while minimizing deleterious effects to off-target sites. Magnetic cell targeting is an efficient, safe, and straightforward delivery technique. Superparamagnetic iron oxide nanoparticles (SPION) are biodegradable, biocompatible, and can be endocytosed into cells to render them responsive to magnetic fields. The synthesis process involves creating magnetite (Fe3O4) nanoparticles followed by high-speed emulsification to form a poly(lactic-co-glycolic acid) (PLGA) coating. The PLGA-magnetite SPIONs are approximately 120 nm in diameter including the approximately 10 nm diameter magnetite core. When placed in culture medium, SPIONs are naturally endocytosed by cells and stored as small clusters within cytoplasmic endosomes. These particles impart sufficient magnetic mass to the cells to allow for targeting within magnetic fields. Numerous cell sorting and targeting applications are enabled by rendering various cell types responsive to magnetic fields. SPIONs have a variety of other biomedical applications as well including use as a medical imaging contrast agent, targeted drug or gene delivery, diagnostic assays, and generation of local hyperthermia for tumor therapy or tissue soldering.


Assuntos
Sistemas de Liberação de Medicamentos/métodos , Nanopartículas de Magnetita/química , Animais , Meios de Contraste , Humanos , Ácido Láctico/química , Ácido Poliglicólico/química , Copolímero de Ácido Poliláctico e Ácido Poliglicólico
19.
J Vis Exp ; (103)2015 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-26436434

RESUMO

Rapid endothelialization of cardiovascular stents is needed to reduce stent thrombosis and to avoid anti-platelet therapy which can reduce bleeding risk. The feasibility of using magnetic forces to capture and retain endothelial outgrowth cells (EOC) labeled with super paramagnetic iron oxide nanoparticles (SPION) has been shown previously. But this technique requires the development of a mechanically functional stent from a magnetic and biocompatible material followed by in-vitro and in-vivo testing to prove rapid endothelialization. We developed a weakly ferromagnetic stent from 2205 duplex stainless steel using computer aided design (CAD) and its design was further refined using finite element analysis (FEA). The final design of the stent exhibited a principal strain below the fracture limit of the material during mechanical crimping and expansion. One hundred stents were manufactured and a subset of them was used for mechanical testing, retained magnetic field measurements, in-vitro cell capture studies, and in-vivo implantation studies. Ten stents were tested for deployment to verify if they sustained crimping and expansion cycle without failure. Another 10 stents were magnetized using a strong neodymium magnet and their retained magnetic field was measured. The stents showed that the retained magnetism was sufficient to capture SPION-labeled EOC in our in-vitro studies. SPION-labeled EOC capture and retention was verified in large animal models by implanting 1 magnetized stent and 1 non-magnetized control stent in each of 4 pigs. The stented arteries were explanted after 7 days and analyzed histologically. The weakly magnetic stents developed in this study were capable of attracting and retaining SPION-labeled endothelial cells which can promote rapid healing.


Assuntos
Técnicas Citológicas/instrumentação , Células Endoteliais/citologia , Nanopartículas de Magnetita , Imãs , Stents , Animais , Desenho Assistido por Computador , Técnicas Citológicas/métodos , Desenho de Equipamento , Análise de Elementos Finitos , Magnetismo/instrumentação , Magnetismo/métodos , Suínos
20.
J Neurointerv Surg ; 6(2): e14, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23493342

RESUMO

We present a computational fluid dynamics (CFD) analysis of the hemodynamic environment of an anterior communicating artery that spontaneously ruptured immediately following three-dimensional rotational angiography. Subsequent digital subtraction angiography allowed for the localization of the point of rupture within the aneurysm dome. CFD analysis demonstrated a concentrated jet that impinged directly at the site of rupture. Peak systolic pressure and wall shear stress were both maximal near the rupture location.


Assuntos
Angiografia Cerebral/efeitos adversos , Simulação por Computador , Hidrodinâmica , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/etiologia , Humanos